Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empiric...Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empirical correlations for gas holdup and liquid velocity are proposed to ease the reactor design and scale-up.Different bubble circulation regimes were displayed in the first(lower) and second(upper) stages.Increasing superficial gas velocity and solid loading can promote regime transition of the second stage,and the gas holdup of the second stage is higher than that of the lower stage.In addition,the effects of solid loading on bubble behaviour are experimentally investigated for each stage.It is found that bubble size in the downcomer decreases with the presence of solid particles,and bubble size distribution widens under higher superficial gas velocity and lower solid loading.展开更多
The external loop airlift reactor(ELALR)is widely used for gasliquid reactions.It’s advantage of good heat and mass transfer rates compared to conventional bubble column reactors.In the case of fermentation applicati...The external loop airlift reactor(ELALR)is widely used for gasliquid reactions.It’s advantage of good heat and mass transfer rates compared to conventional bubble column reactors.In the case of fermentation application where a medium is highly viscous and coalescing in nature,internal in riser helps in the improvement of the interfacial area as well as in the reduction of liquidphase back mixing.The computational fluid dynamic(CFD)as a tool is used to design and scaleup of sectionalized external loop airlift reactor.The present work deals with computational fluid dynamics(CFD)techniques and experimental measurement of a gas holdup,liquid circulation velocity,liquid axial velocity,Sauter mean bubble diameter over a broad range of superficial gas velocity 0.0024≤UG≤0.0168 m s 1.The correlation has been made for bubble size distribution with specific power consumption for different plate configurations.The effects of an internal on different mass transfer models have been completed to assess their suitability.The predicted local mass transfer coefficient has been found higher in the sectionalized external loop airlift reactor than the conventional ELALR.展开更多
In this paper, a 2-D airlift reactor was developed. The streamline and hydrodynamic parameters were measured in a 2-D airlift loop reactor(ALR)with different draft baffles. Three regimes were observed under different ...In this paper, a 2-D airlift reactor was developed. The streamline and hydrodynamic parameters were measured in a 2-D airlift loop reactor(ALR)with different draft baffles. Three regimes were observed under different conditions. Particle image velocimetry(PIV)measurement showed that the liquid velocity distribution in horizontal direction presented different profiles in the three regimes. The length, the height and the spacing of draft baffles were applied in the experiments to optimize the ALR structure. It was found that the draft tube structure is of great importance in determining the hydrodynamics of ALRs. Additionally, the experimental results may serve as a step to the further optimization and design of ALR.展开更多
Oilfield produced water is large quantities of salty water trapped in underground formations and subsisted under high temperatures and pressures that are brought to the surface along with oil during production. Produc...Oilfield produced water is large quantities of salty water trapped in underground formations and subsisted under high temperatures and pressures that are brought to the surface along with oil during production. Produced water(PW) contains a lot of pollutants such as hydrocarbons and metals, this water must be treated before disposal. Therefore, different techniques are being used to treat produced water. Electrocoagulation is an efficient treatment technique involving the dissolution of anodes and formation of electro-coagulants, while the simultaneous generation of H_2 bubbles at the cathode leads to the pollutant removal by flotation. Electrocoagulation(EC)method is one of the most promising and widely used processes to treat oilfield produced water. In the present work, a conventional internal-loop(draught tube) airlift reactor was utilized as electrocoagulation/flotation cell for PW treatment by inserting two aluminum electrodes in the riser section of the airlift reactor. The EC airlift reactor was operated in a batch mode for the liquid phase. Different experimental parameters were studied on the oil and turbidity removal efficiencies such as current density, initial pH, electrocoagulation time, and air injection.The experimental results showed that mixing of the oil droplets in the PW was accomplished using only the liquid recirculation resulted by H_2 microbubbles generated by EC process which enhanced the oil removal. The experimental results further showed that the EC time required achieving ≥ 90% oil removal efficiency decreases from 46 to 15 min when operating current density increases from 6.8 to 45.5 mA·cm^(-2). This reactor type was found to be highly efficient and less energy consuming compared to conventional existing electrochemical cells which used mechanical agitation.展开更多
This paper studied the efficiency of electrocoagulation/electroflotation in removing colour from real textile wastewater by using aluminum and iron electrodes in an innovative pilot external-loop airlift reactor of 15...This paper studied the efficiency of electrocoagulation/electroflotation in removing colour from real textile wastewater by using aluminum and iron electrodes in an innovative pilot external-loop airlift reactor of 150 L. The reactor was designed to operate in batch and continuous modes. The real effluent contained 90% of disperse dye and 10% of reactive dye. A complete flotation of pollutants with acceptable mixing was achieved in this reactor using only the overall liquid recirculation induced by H2 microbubbles. The treatment of these discharges was easier using electrodes of iron rather than aluminum. The optimal initial pH was 10 for both aluminum and iron electrodes. By using iron electrodes, the maximum decolourisation efficiency and COD reduction efficiency reached respectively 96% and 65% for 90 minutes of treatment. Similarly, by using aluminum electrodes, the maximum decolourisation efficiency reached 90%, COD reduction reached 51% for 120 minutes of treatment. In the case of an initial pH slightly different to 10, the required time to reach 90% ranged from double to triple.展开更多
In this work, the overall gas hold-up in the riser and down-comer of three internal airlift reactors with a working volume of 10.5, 32 and 200 l at the range of temperatures 18℃ - 21℃, under atmospheric pressure was...In this work, the overall gas hold-up in the riser and down-comer of three internal airlift reactors with a working volume of 10.5, 32 and 200 l at the range of temperatures 18℃ - 21℃, under atmospheric pressure was simulated using Com-putational Fluid Dynamics (CFD). The range of superficial gas velocity was 0.5 - 3 cm/s. The three reactors geometrically were similar to each other. CFD simulation and experimental data showed that the gas hold-up in the riser and down-comer increased by increasing the reactor scale. It was concluded that the simulated data were in good agreement with the experimental ones obtained from the literature.展开更多
In an internal loop airlift reactor of 55L working volume,the gas-liquid volumetric oxygenmass transfer coefficient k_Lα,gas holdup ε_G and liquid circulation time t_c were measured with the sol-ution of carboxymeth...In an internal loop airlift reactor of 55L working volume,the gas-liquid volumetric oxygenmass transfer coefficient k_Lα,gas holdup ε_G and liquid circulation time t_c were measured with the sol-ution of carboxymethyl cellulose(CMC)to simulate the performance of a reactor with highly viscousbroth.Electric conductivity and oxygen probes were used to measure the local gas holdup,liquidcirculation time and oxygen mass transfer coefficient in the individual sections of the reactor(riser,downcomer and the gas-liquid separating section at the top of the reactor)and the total reactor,respectively.The values of k_Lα for the riser,downcomer and separation sections of the reactor were alsoestimated and compared with that for the total reactor.The results show that,both k_Lα and ε_G in-crease but t_c decreases with increasing gas velocity.Correlations and comparisons with works reportedin the literature are also presented.Data show that the methods developed for k_Lα measurements inthe individual section展开更多
Airlift reactors are used in a wide range of industries,such as hydrometallurgy,biochemical processes,chemical process industry and wastewater treatment.Despite the simple structure of airlift reactors,the flow field ...Airlift reactors are used in a wide range of industries,such as hydrometallurgy,biochemical processes,chemical process industry and wastewater treatment.Despite the simple structure of airlift reactors,the flow field becomes complex with increasing gas velocity,and gas bubbles in the circulating regime can be observed in practice.In this paper,a numerical modelling method based on computational fluid dynamics(CFD)is presented for gas-liquid flow in airlift reactors under different bubble recirculation regimes.Gas-liquid flow was modelled using the Eulerian two-fluid equations,and extra user defined subroutines were incorporated to consider the complex physics,such as bubble-induced turbulence and turbulent dispersion force.Some alternative correlations for drag coefficient were tested to compare their ability to capture the bubble distributions in the riser and downcomer of the airlift reactors,with consideration of the interaction between bubbles.A model including multiple bubble sizes was applied to obtain more accurate simulation results of gas holdup and water velocity.Also,the use of the inhomogeneous multiple-size-group(MUSIG)model was explored as a way to better predict the complex flow regimes.The modelling method was applied to a laboratory internal loop airlift reactor,and the simulation results were compared with the published experimental measurements for gas holdup and water velocity.Reasonable agreement was obtained over a range of operating conditions,and an improvement was demonstrated using the proposed method.The simulations have shown that the inhomogeneous MUSIG model is a suitable tool to describe the complex gas-liquid interaction in the airlift reactor at a high gas superficial velocity.展开更多
The flow behavior and mass transfer in a three-phase external-loop airlift reactor can be improved by adding large particles. The mass transfer and liquid dispersion behavior for a three-phase external-loop reactor wi...The flow behavior and mass transfer in a three-phase external-loop airlift reactor can be improved by adding large particles. The mass transfer and liquid dispersion behavior for a three-phase external-loop reactor with large particles are studied in terms of the effect of the diameter and loading of the large particles on the liquid dispersion coefficient and mass transfer coefficient, The results showed that increasing the diameter or loading of the large particles tend to decrease dispersion and intensify mass transfer, and that an increase in the diameter of the large particles remarkably decreases the particle loop rate, while the effect of fine particles is much less notable.展开更多
In terms of gas holdup,liquid velocity,and volumetric mass transfer coefficient for oxygen(KLa),the hydrodynamic behavior of four configurations of an airlift reactor(ALR)with a net draft tube(NDT)of different net mes...In terms of gas holdup,liquid velocity,and volumetric mass transfer coefficient for oxygen(KLa),the hydrodynamic behavior of four configurations of an airlift reactor(ALR)with a net draft tube(NDT)of different net mesh sizes(ALR-NDT-3,6,12,and ALR)have been numerically simulated for a range of inlet air flow rates.The effect of various levels of ratio of height(H)to inner tube diameter(D)of the net draft tube(H/D:9.3,10.7,17.5,and 20)and ratio of inner cross-sectional area of the riser(Ar)to the inner cross sectional area of the downcomer(Ad)(Ad/Ar:1.3 and 7)for different air flow rates is also evaluated for each reactor configuration operating with an air-water system.The two-fluid formulation coupled with the k-εturbulence model is used for computational fluid dynamics(CFD)analysis of flow with Eulerian descriptions for the gas and liquid phases.Interactions between air bubbles and liquid are taken into account using momentum exchange and drag coefficient based on two different correlations.Trends in the predicted dynamical behavior are similar to those found experimentally.A good agreement was achieved suggesting that geometric effects are properly accounted for by the CFD model.After a comparison with experimental data,numerical simulations show significant enhanced gas holdup,liquid velocity,and Kta for the ALR-NDTs compared with the conventional ALR.Higher gas holdup values are achieved for ALR-NDT-3 than that for the other ALRs because it acts like a bubble column reactor as the holes present in the NDT are large.Maximum liquid velocities are seen in ALR-NDT-12,which operates like a conventional ALR.Moreover,the interaction between the NDT and upward gas flow leads to cross flow through the net,small bubbles,and high interfacial area as well as good mass transfer.This was significant in ALR-NDT-6 with maximum Kta value of 0.031 s-1.The applied methodology provides an insightful understanding of the complex dynamic behavior of ALR-NDTs and may be helpful in optimizing the design and scale-up of reactors.展开更多
Local hydrodynamics in the riser of an external loop airlift reactor (EL-ALR) are identified and the performances of three drag models are evaluated in computational fluid dynamics simulation. The simulation results...Local hydrodynamics in the riser of an external loop airlift reactor (EL-ALR) are identified and the performances of three drag models are evaluated in computational fluid dynamics simulation. The simulation results show that the Schiller-Naumann drag model underestimated the local gas holdup at lower superficial gas velocity whereas the Tomiyama drag model overestimated that at higher superficial gas velocity. By contrast, the dual-bubble-size (DBS)-local drag model gave more reasonable radial and axial distri-butions of gas holdup in all cases. The reason is that the DBS-local drag model gave correct values of the lumped parameter, i,e., the ratio of the drag coefficient to bubble diameter, for varying operating conditions and radial positions. This ratio is reasonably expected to decrease with increasing superficial gas velocity and be smaller in the center and larger near the wall. Only the DBS-local drag model correctly reproduced these trends. The radial profiles of the axial velocity of the liquid and gas predicted by the DBS-local model also agreed well with experimental data.展开更多
A new developed external loop airlift slurry reactor, which was integrated with gas–liquid–solid three-phase mixing, mass transfer, and liquid–solid separation simultaneously, was deemed to be a promising slurry re...A new developed external loop airlift slurry reactor, which was integrated with gas–liquid–solid three-phase mixing, mass transfer, and liquid–solid separation simultaneously, was deemed to be a promising slurry reactor due to its prominent advantages such as achieving continuous separation of clear liquid from slurry and cyclic utilization of solid particles without any extra energy, energy-saving, and intrinsic safety design. The principal operating parameters, including gas separator volume, handling capacity, and superficial gas velocity, are systematically investigated here to promote the capabilities of mixing, mass transfer, and yield in the pilot external loop airlift slurry reactor. The influences of top clearance and throughput of the clear liquid on flow regime and gas holdup in the riser, liquid circulating velocity, and volumetric mass transfer coefficient with a typical high solid holdup and free of particles are examined experimentally. It was found that increasing the gas separator volume could promote the liquid circulating velocity by about 14.0% at most. Increasing the handling capacity of the clear liquid from 0.9 m3·h-1 to 3.0 m3·h-1 not only could increase the output without any adverse consequences, but also could enhance the liquid circulating velocity as much as 97.3%. Typical operating conditions investigated here can provide some necessary data and guidelines for this new external loop airlift slurry reactor to upgrade its performances.展开更多
A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mas...A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mass transfer properties. Based on the analysis of geometrical construction and fluid properties of gas and slurry, MIALR was divided into six flow regions. In these flow regions, the local hydrodynamic characteristics were investigated over a wide range of operating variables. Furthermore, a new method was developed to measure the dissolved oxygen concentration. The volumetric mass-transfer coefficient in six flow regions was also calculated for comparison.展开更多
Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 ...Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 flow rate, ultrasonic intensity and initial concentration of dimethoate on degradation rate were investigated. UALR imposed a synergistic effect combining sonochemical merit with high O3 transfer rate. The results showed that UALR not only increased degradation rate, but also was better than the simole sum of degradation by O3 and ultrasound separately. Under the operation conditions of O3 flow of 0.34 m^3·h^-1, ultrasonic intensity 3.71 W.cm^-2, and initial concentration of dimethoate at 20 mg·L^- 1, the degradation rate of dimethoate increased to 80%. UALR seems an advisable choice for treating organic wastewater and this process may have wide application prospect in industry.展开更多
Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-ge...Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-gen gas flow rate on the conversion of cyclohexene and selectivity of cyclohexene oxide were investigated and dis-cussed, and the optimal operation condition was found, under which 95.2% conversion of cyclohexene and 90.7% selectivity of cyclohexene oxide were achieved. The ultrasonic airlift loop reactor utilizes the synergistic effect of sonochemsitry and higher oxygen transfer rate. Possible reaction mechanisms were outlined and the reason of ul-trasound promotion of epoxidation reactionwas analyzed.展开更多
Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in ...Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in multiphase systems. According to the model of macro-scale mass transfer in airlift loop reactors, it was proved that the airlift loop reactor can be regarded as a continuous stirred tank reactor for measuring mass transfer coefficient. The calculated mass transfer coefficient on such a basis is different from the volumetric mass transfer coefficient in the macro-scale model and the difference is discussed. To describe the time delay of the probe response to the change of oxygen concentration in the liquid phase, a model taking into account the time constant of response is es-tablished. Sensitivity analysis shows that this model can be used to measure the volumetric mass transfer coefficient. Applying this model to the measurement of volumetric mass transfer coefficient in the loop reactor, results that co-incide with the turbulence theory in the literate were obtained.展开更多
Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemi...Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemical method was adapted to measure local gas holdup andliquid velocity.A two-dimensional two-fluid model based on the first principles was established andimplemented to model the flow in airlift loop reactors.A corrected turbulent model was incorporatedin the simulation.The shear rate,shear stress and energy dissipation are evaluated from the flowfield.The numerically predicted results and experimental data obtained from this work as well as thesereported in literature are analyzed and compared.展开更多
A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp...A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp, Qg and dD/dR were optimized. The average molar yield and purity of 2-chloro-5-chloromethylpyridine obtained were 79% and 98.5% respectively under the optimum operating conditions. Finally, the efficiency for the preparation of 2-chloro-5-chloromethylpyridine with ALR and stirred tank reactor (STR) respectively was compared.展开更多
New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reacto...New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reactor. The pores blocking models were created based on the standard blocking law and the intermediate blocking law, and then the cake layer models were developed based on the hydrodynamic theory in which the calculation method of porosity of cake layer was newly corrected. The Air-Water-FCC equilibrium catalysts cold model experiment was used to verify the relevant models.Results showed that the calculated values fitted well with experimental data with a relative error of less than 10%.展开更多
Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared thr...Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared through several flow mixing models. The modeling results of two-parameter model indicated that there were higher ratio of full mixing zones and lower ratio of bypass flow in AL than in BC. Then a completely mixed-plug flow parallel combined (four-parameter) model was established. Modeling results show that it is more precise and more obvious than two-parameter model.展开更多
基金Supported by the State Key Laboratory of Chemical Engineering(SKL-ChE-16B01)China Postdoctoral Science Foundation(2016M601263)
文摘Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empirical correlations for gas holdup and liquid velocity are proposed to ease the reactor design and scale-up.Different bubble circulation regimes were displayed in the first(lower) and second(upper) stages.Increasing superficial gas velocity and solid loading can promote regime transition of the second stage,and the gas holdup of the second stage is higher than that of the lower stage.In addition,the effects of solid loading on bubble behaviour are experimentally investigated for each stage.It is found that bubble size in the downcomer decreases with the presence of solid particles,and bubble size distribution widens under higher superficial gas velocity and lower solid loading.
文摘The external loop airlift reactor(ELALR)is widely used for gasliquid reactions.It’s advantage of good heat and mass transfer rates compared to conventional bubble column reactors.In the case of fermentation application where a medium is highly viscous and coalescing in nature,internal in riser helps in the improvement of the interfacial area as well as in the reduction of liquidphase back mixing.The computational fluid dynamic(CFD)as a tool is used to design and scaleup of sectionalized external loop airlift reactor.The present work deals with computational fluid dynamics(CFD)techniques and experimental measurement of a gas holdup,liquid circulation velocity,liquid axial velocity,Sauter mean bubble diameter over a broad range of superficial gas velocity 0.0024≤UG≤0.0168 m s 1.The correlation has been made for bubble size distribution with specific power consumption for different plate configurations.The effects of an internal on different mass transfer models have been completed to assess their suitability.The predicted local mass transfer coefficient has been found higher in the sectionalized external loop airlift reactor than the conventional ELALR.
基金Supported by the National Natural Science Foundation of China(No.21406157)
文摘In this paper, a 2-D airlift reactor was developed. The streamline and hydrodynamic parameters were measured in a 2-D airlift loop reactor(ALR)with different draft baffles. Three regimes were observed under different conditions. Particle image velocimetry(PIV)measurement showed that the liquid velocity distribution in horizontal direction presented different profiles in the three regimes. The length, the height and the spacing of draft baffles were applied in the experiments to optimize the ALR structure. It was found that the draft tube structure is of great importance in determining the hydrodynamics of ALRs. Additionally, the experimental results may serve as a step to the further optimization and design of ALR.
文摘Oilfield produced water is large quantities of salty water trapped in underground formations and subsisted under high temperatures and pressures that are brought to the surface along with oil during production. Produced water(PW) contains a lot of pollutants such as hydrocarbons and metals, this water must be treated before disposal. Therefore, different techniques are being used to treat produced water. Electrocoagulation is an efficient treatment technique involving the dissolution of anodes and formation of electro-coagulants, while the simultaneous generation of H_2 bubbles at the cathode leads to the pollutant removal by flotation. Electrocoagulation(EC)method is one of the most promising and widely used processes to treat oilfield produced water. In the present work, a conventional internal-loop(draught tube) airlift reactor was utilized as electrocoagulation/flotation cell for PW treatment by inserting two aluminum electrodes in the riser section of the airlift reactor. The EC airlift reactor was operated in a batch mode for the liquid phase. Different experimental parameters were studied on the oil and turbidity removal efficiencies such as current density, initial pH, electrocoagulation time, and air injection.The experimental results showed that mixing of the oil droplets in the PW was accomplished using only the liquid recirculation resulted by H_2 microbubbles generated by EC process which enhanced the oil removal. The experimental results further showed that the EC time required achieving ≥ 90% oil removal efficiency decreases from 46 to 15 min when operating current density increases from 6.8 to 45.5 mA·cm^(-2). This reactor type was found to be highly efficient and less energy consuming compared to conventional existing electrochemical cells which used mechanical agitation.
文摘This paper studied the efficiency of electrocoagulation/electroflotation in removing colour from real textile wastewater by using aluminum and iron electrodes in an innovative pilot external-loop airlift reactor of 150 L. The reactor was designed to operate in batch and continuous modes. The real effluent contained 90% of disperse dye and 10% of reactive dye. A complete flotation of pollutants with acceptable mixing was achieved in this reactor using only the overall liquid recirculation induced by H2 microbubbles. The treatment of these discharges was easier using electrodes of iron rather than aluminum. The optimal initial pH was 10 for both aluminum and iron electrodes. By using iron electrodes, the maximum decolourisation efficiency and COD reduction efficiency reached respectively 96% and 65% for 90 minutes of treatment. Similarly, by using aluminum electrodes, the maximum decolourisation efficiency reached 90%, COD reduction reached 51% for 120 minutes of treatment. In the case of an initial pH slightly different to 10, the required time to reach 90% ranged from double to triple.
文摘In this work, the overall gas hold-up in the riser and down-comer of three internal airlift reactors with a working volume of 10.5, 32 and 200 l at the range of temperatures 18℃ - 21℃, under atmospheric pressure was simulated using Com-putational Fluid Dynamics (CFD). The range of superficial gas velocity was 0.5 - 3 cm/s. The three reactors geometrically were similar to each other. CFD simulation and experimental data showed that the gas hold-up in the riser and down-comer increased by increasing the reactor scale. It was concluded that the simulated data were in good agreement with the experimental ones obtained from the literature.
基金Supported by the National Natural Science Foundation of China
文摘In an internal loop airlift reactor of 55L working volume,the gas-liquid volumetric oxygenmass transfer coefficient k_Lα,gas holdup ε_G and liquid circulation time t_c were measured with the sol-ution of carboxymethyl cellulose(CMC)to simulate the performance of a reactor with highly viscousbroth.Electric conductivity and oxygen probes were used to measure the local gas holdup,liquidcirculation time and oxygen mass transfer coefficient in the individual sections of the reactor(riser,downcomer and the gas-liquid separating section at the top of the reactor)and the total reactor,respectively.The values of k_Lα for the riser,downcomer and separation sections of the reactor were alsoestimated and compared with that for the total reactor.The results show that,both k_Lα and ε_G in-crease but t_c decreases with increasing gas velocity.Correlations and comparisons with works reportedin the literature are also presented.Data show that the methods developed for k_Lα measurements inthe individual section
基金support from National Key R&D Program of China(No.2021YFC2902700)pilot project of BGRIMM Technology Group(No.02-2407)special fund of National Key Laboratory of Ni&Co Associated Minerals Resources Development and Comprehensive Utilization(No.GZSYS-KY-2022-014).
文摘Airlift reactors are used in a wide range of industries,such as hydrometallurgy,biochemical processes,chemical process industry and wastewater treatment.Despite the simple structure of airlift reactors,the flow field becomes complex with increasing gas velocity,and gas bubbles in the circulating regime can be observed in practice.In this paper,a numerical modelling method based on computational fluid dynamics(CFD)is presented for gas-liquid flow in airlift reactors under different bubble recirculation regimes.Gas-liquid flow was modelled using the Eulerian two-fluid equations,and extra user defined subroutines were incorporated to consider the complex physics,such as bubble-induced turbulence and turbulent dispersion force.Some alternative correlations for drag coefficient were tested to compare their ability to capture the bubble distributions in the riser and downcomer of the airlift reactors,with consideration of the interaction between bubbles.A model including multiple bubble sizes was applied to obtain more accurate simulation results of gas holdup and water velocity.Also,the use of the inhomogeneous multiple-size-group(MUSIG)model was explored as a way to better predict the complex flow regimes.The modelling method was applied to a laboratory internal loop airlift reactor,and the simulation results were compared with the published experimental measurements for gas holdup and water velocity.Reasonable agreement was obtained over a range of operating conditions,and an improvement was demonstrated using the proposed method.The simulations have shown that the inhomogeneous MUSIG model is a suitable tool to describe the complex gas-liquid interaction in the airlift reactor at a high gas superficial velocity.
文摘The flow behavior and mass transfer in a three-phase external-loop airlift reactor can be improved by adding large particles. The mass transfer and liquid dispersion behavior for a three-phase external-loop reactor with large particles are studied in terms of the effect of the diameter and loading of the large particles on the liquid dispersion coefficient and mass transfer coefficient, The results showed that increasing the diameter or loading of the large particles tend to decrease dispersion and intensify mass transfer, and that an increase in the diameter of the large particles remarkably decreases the particle loop rate, while the effect of fine particles is much less notable.
文摘In terms of gas holdup,liquid velocity,and volumetric mass transfer coefficient for oxygen(KLa),the hydrodynamic behavior of four configurations of an airlift reactor(ALR)with a net draft tube(NDT)of different net mesh sizes(ALR-NDT-3,6,12,and ALR)have been numerically simulated for a range of inlet air flow rates.The effect of various levels of ratio of height(H)to inner tube diameter(D)of the net draft tube(H/D:9.3,10.7,17.5,and 20)and ratio of inner cross-sectional area of the riser(Ar)to the inner cross sectional area of the downcomer(Ad)(Ad/Ar:1.3 and 7)for different air flow rates is also evaluated for each reactor configuration operating with an air-water system.The two-fluid formulation coupled with the k-εturbulence model is used for computational fluid dynamics(CFD)analysis of flow with Eulerian descriptions for the gas and liquid phases.Interactions between air bubbles and liquid are taken into account using momentum exchange and drag coefficient based on two different correlations.Trends in the predicted dynamical behavior are similar to those found experimentally.A good agreement was achieved suggesting that geometric effects are properly accounted for by the CFD model.After a comparison with experimental data,numerical simulations show significant enhanced gas holdup,liquid velocity,and Kta for the ALR-NDTs compared with the conventional ALR.Higher gas holdup values are achieved for ALR-NDT-3 than that for the other ALRs because it acts like a bubble column reactor as the holes present in the NDT are large.Maximum liquid velocities are seen in ALR-NDT-12,which operates like a conventional ALR.Moreover,the interaction between the NDT and upward gas flow leads to cross flow through the net,small bubbles,and high interfacial area as well as good mass transfer.This was significant in ALR-NDT-6 with maximum Kta value of 0.031 s-1.The applied methodology provides an insightful understanding of the complex dynamic behavior of ALR-NDTs and may be helpful in optimizing the design and scale-up of reactors.
文摘Local hydrodynamics in the riser of an external loop airlift reactor (EL-ALR) are identified and the performances of three drag models are evaluated in computational fluid dynamics simulation. The simulation results show that the Schiller-Naumann drag model underestimated the local gas holdup at lower superficial gas velocity whereas the Tomiyama drag model overestimated that at higher superficial gas velocity. By contrast, the dual-bubble-size (DBS)-local drag model gave more reasonable radial and axial distri-butions of gas holdup in all cases. The reason is that the DBS-local drag model gave correct values of the lumped parameter, i,e., the ratio of the drag coefficient to bubble diameter, for varying operating conditions and radial positions. This ratio is reasonably expected to decrease with increasing superficial gas velocity and be smaller in the center and larger near the wall. Only the DBS-local drag model correctly reproduced these trends. The radial profiles of the axial velocity of the liquid and gas predicted by the DBS-local model also agreed well with experimental data.
基金supported by the National Natural Science Foundation of China (Nos. 21808234,21878318)the DNL Cooperation Fund,CAS(DNL201902)+3 种基金“Transformational Technologies for Clean Energy and Demonstration”, Strategic Priority Research Program of the CAS(XDA21060400)QIBEBT and Dalian National Laboratory for Clean Energy of the CAS(QIBEBT ZZBS201803,QIBEBT I201907)CAS Key Technology Talent ProgramProject of CNPC-DICP Joint Research Center。
文摘A new developed external loop airlift slurry reactor, which was integrated with gas–liquid–solid three-phase mixing, mass transfer, and liquid–solid separation simultaneously, was deemed to be a promising slurry reactor due to its prominent advantages such as achieving continuous separation of clear liquid from slurry and cyclic utilization of solid particles without any extra energy, energy-saving, and intrinsic safety design. The principal operating parameters, including gas separator volume, handling capacity, and superficial gas velocity, are systematically investigated here to promote the capabilities of mixing, mass transfer, and yield in the pilot external loop airlift slurry reactor. The influences of top clearance and throughput of the clear liquid on flow regime and gas holdup in the riser, liquid circulating velocity, and volumetric mass transfer coefficient with a typical high solid holdup and free of particles are examined experimentally. It was found that increasing the gas separator volume could promote the liquid circulating velocity by about 14.0% at most. Increasing the handling capacity of the clear liquid from 0.9 m3·h-1 to 3.0 m3·h-1 not only could increase the output without any adverse consequences, but also could enhance the liquid circulating velocity as much as 97.3%. Typical operating conditions investigated here can provide some necessary data and guidelines for this new external loop airlift slurry reactor to upgrade its performances.
文摘A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mass transfer properties. Based on the analysis of geometrical construction and fluid properties of gas and slurry, MIALR was divided into six flow regions. In these flow regions, the local hydrodynamic characteristics were investigated over a wide range of operating variables. Furthermore, a new method was developed to measure the dissolved oxygen concentration. The volumetric mass-transfer coefficient in six flow regions was also calculated for comparison.
文摘Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 flow rate, ultrasonic intensity and initial concentration of dimethoate on degradation rate were investigated. UALR imposed a synergistic effect combining sonochemical merit with high O3 transfer rate. The results showed that UALR not only increased degradation rate, but also was better than the simole sum of degradation by O3 and ultrasound separately. Under the operation conditions of O3 flow of 0.34 m^3·h^-1, ultrasonic intensity 3.71 W.cm^-2, and initial concentration of dimethoate at 20 mg·L^- 1, the degradation rate of dimethoate increased to 80%. UALR seems an advisable choice for treating organic wastewater and this process may have wide application prospect in industry.
基金Supported by Qinglan Project Foundation of Jiangsu Province and Doctoral Dissertation Innovate Foundation of Nanjing Uni-versity of Technology (No.BSCS200508).
文摘Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-gen gas flow rate on the conversion of cyclohexene and selectivity of cyclohexene oxide were investigated and dis-cussed, and the optimal operation condition was found, under which 95.2% conversion of cyclohexene and 90.7% selectivity of cyclohexene oxide were achieved. The ultrasonic airlift loop reactor utilizes the synergistic effect of sonochemsitry and higher oxygen transfer rate. Possible reaction mechanisms were outlined and the reason of ul-trasound promotion of epoxidation reactionwas analyzed.
基金Supported by the Specialized Research Fund for the Program of Higher Education (No.20050003030) and byTsinghua-Zhongda Postdoctoral Fellowship Program (No.20283600131).
文摘Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in multiphase systems. According to the model of macro-scale mass transfer in airlift loop reactors, it was proved that the airlift loop reactor can be regarded as a continuous stirred tank reactor for measuring mass transfer coefficient. The calculated mass transfer coefficient on such a basis is different from the volumetric mass transfer coefficient in the macro-scale model and the difference is discussed. To describe the time delay of the probe response to the change of oxygen concentration in the liquid phase, a model taking into account the time constant of response is es-tablished. Sensitivity analysis shows that this model can be used to measure the volumetric mass transfer coefficient. Applying this model to the measurement of volumetric mass transfer coefficient in the loop reactor, results that co-incide with the turbulence theory in the literate were obtained.
基金Supported by the National Natural Science Foundation of China.
文摘Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemical method was adapted to measure local gas holdup andliquid velocity.A two-dimensional two-fluid model based on the first principles was established andimplemented to model the flow in airlift loop reactors.A corrected turbulent model was incorporatedin the simulation.The shear rate,shear stress and energy dissipation are evaluated from the flowfield.The numerically predicted results and experimental data obtained from this work as well as thesereported in literature are analyzed and compared.
基金Natural Science Foundation of Tianjin(No.013605711)National Natural Science Foundation of China(No.20176040)
文摘A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp, Qg and dD/dR were optimized. The average molar yield and purity of 2-chloro-5-chloromethylpyridine obtained were 79% and 98.5% respectively under the optimum operating conditions. Finally, the efficiency for the preparation of 2-chloro-5-chloromethylpyridine with ALR and stirred tank reactor (STR) respectively was compared.
基金financially supported by the National Key Research & Development Program of China (2016YFB0301600)
文摘New modified combination mathematical models including the pores blocking models and the cake layer models were developed to describe the continuous cross-flow microfiltration in an airlift external loop slurry reactor. The pores blocking models were created based on the standard blocking law and the intermediate blocking law, and then the cake layer models were developed based on the hydrodynamic theory in which the calculation method of porosity of cake layer was newly corrected. The Air-Water-FCC equilibrium catalysts cold model experiment was used to verify the relevant models.Results showed that the calculated values fitted well with experimental data with a relative error of less than 10%.
文摘Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared through several flow mixing models. The modeling results of two-parameter model indicated that there were higher ratio of full mixing zones and lower ratio of bypass flow in AL than in BC. Then a completely mixed-plug flow parallel combined (four-parameter) model was established. Modeling results show that it is more precise and more obvious than two-parameter model.