Energy shortage has become one of themost concerning issues in the world today,and improving energy utilization efficiency is a key area of research for experts and scholars worldwide.Small-diameter heat exchangers of...Energy shortage has become one of themost concerning issues in the world today,and improving energy utilization efficiency is a key area of research for experts and scholars worldwide.Small-diameter heat exchangers offer advantages such as reduced material usage,lower refrigerant charge,and compact structure.However,they also face challenges,including increased refrigerant pressure drop and smaller heat transfer area inside the tubes.This paper combines the advantages and disadvantages of both small and large-diameter tubes and proposes a combined-diameter heat exchanger,consisting of large and small diameters,for use in the indoor units of split-type air conditioners.There are relatively few studies in this area.In this paper,A theoretical and numerical computation method is employed to establish a theoretical-numerical calculation model,and its reliability is verified through experiments.Using this model,the optimal combined diameters and flow path design for a combined-diameter heat exchanger using R32 as the working fluid are derived.The results show that the heat transfer performance of all combined diameter configurations improves by 2.79%to 8.26%compared to the baseline design,with the coefficient of performance(COP)increasing from 4.15 to 4.27~4.5.These designs can save copper material,but at the cost of an increase in pressure drop by 66.86%to 131.84%.The scheme IIIH,using R32,is the optimal combined-diameter and flow path configuration that balances both heat transfer performance and economic cost.展开更多
Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooli...Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooling mode,the coefficient of performance(COP)was 1.176 due to the techniques used in this device,and it increased to 1.24 in the last minute of operation.Concerning the steady-state scenario,from the first minute,the Qc was larger than the W for the entire duration of the operation.The output temperature reaches 18.97℃ ,and the temperature on the cold side reaches 4.96℃ in the fifteen minutes of operation.The cooling mood was checked in Iraq/Baghdad in October with a temperature of 31℃ .Furthermore,the heating mode was checked in December with a temperature of 22℃ .Due to the size of the component on the cold side being small compared with the size of the component on the heat side,it reached a steady state in 13 min.This means the COP in heating mode reached 1.01 in 14 min.Furthermore,due to the presence of a thermal insulator made inside the device to separate the cold side and the hot side,the difference in temperature causes a noticeable little ascent.This is why the COP increased because it kept the degree differences low.Performance enhancements were achieved by optimizing the behavior of thermoelectric materials.The device contains 3 Peltier elements,a water-cooled system with one Peltier,a heat sink,and a fan.The design of the dehumidification system addresses the humidity issue commonly associated with thermoelectric air conditioners.In this context,the results indicate that the humidity rates had decreased and the cooling rate had increased with these innovative techniques,and thus,excellent performance can be achieved even if the Seebeck coefficient is not at its highest based on the condition of providing the Peltier elements’reliability and optimal thermal performance for various applications requiring both cooling and heating functions.The insulation plays a critical role in maintaining the efficiency of the system,reducing energy consumption,and ensuring long-term functionality.The proposed system is valuable for devices or environments that demand precise and dual thermal control with minimal energy wastage.展开更多
The energy consumption of a Split air conditioning unit(ACU)inside a building is extremely large,and efforts to decrease this issue are ongoing.The current work aims to experimentally investigate the thermal performan...The energy consumption of a Split air conditioning unit(ACU)inside a building is extremely large,and efforts to decrease this issue are ongoing.The current work aims to experimentally investigate the thermal performance of ACU using an external cooling-water loop for pre-cooling the condenser to improve the efficiency and to reduce energy consumption by reducing refrigerant temperature before entering the condenser,thereby reducing the coefficient of performance.The experiments are performed on ACU with and without using an external cooling-water loop under different climate conditions.By using the experimental data,the systems’performances for both cases are evaluated based on the energy,exergy,and pressure drop analysis.Effects of several parameters,e.g.,ambient temperature,inlet water temperature,and water volume flow rate,on the energy and exergy performances of ACU systems are presented for the purpose of comparison.The outcomes display that the use of an external cooling water loop system has a significant impact on the system performance as compared to conventional ACU.The results display that the addition of an external cooling-water loop leads to a reduction in the compressor power consumption and to an increase in the coefficient of performance(COP)as compared to a normal ACU.The maximum reduction in compressor power consumption is obtained equal 37%at T_(w)=15℃and 11 L/min,whereas the maximum enhancement in COP is obtained equal 21.5%at T_(w)=30℃,11 L/min,and T_(amb)=45℃.The modified model shows an increase in exergy efficiency with the maximum enhancement of about 17%at T_(w)=30℃and 15.8 L/min.The use of an external cooling water loop leads to a reduction in the irreversibility process of the compressor,evaporator and expansion valve and to an increase in the condenser losses.The outcomes show that the pressure drop is reduced by using a cooling water loop as compared to a normal ACU,where the reduction becomes more evident with a reduction in water volume flow rate and inlet temperature.Finally,the present study reveals that the use of an external cooling water loop system leads to an improvement in the performance of ACUs.展开更多
LDACs(liquid desiccant air-conditioners)with heat pump can perform cooling dehumidification or heating humidification,and have high energy-saving and sterilization performance.Therefore,they are installed in hospitals...LDACs(liquid desiccant air-conditioners)with heat pump can perform cooling dehumidification or heating humidification,and have high energy-saving and sterilization performance.Therefore,they are installed in hospitals,nursing homes,and food factories,where humidity control is required.However,LiCl(lithium chloride),a conventional humidity control liquid,is highly corrosive to metals,requiring the use of highly corrosion-resistant materials for the pipes and the heat exchangers.These lead to the problem that the manufacturing cost of the air conditioner increases.Therefore,we developed an inexpensive and compact LDAC by adopting a novel IL(ionic liquid)that does not corrode the metals commonly used in air conditioners.In this study,we evaluated the metal solubilities and sterilizing properties of the IL.Based on the physical properties of the IL,the humidity control module was improved for the purpose of downsizing and cost reduction of the unit.Moreover,we conducted a performance evaluation of the LDAC in the environmental test room under the condition in which temperature and humidity change rapidly in short period of time to simulate the condition of sudden showers of rain in summer.Test results showed that processed air was supplied at very stable level.展开更多
As an indispensable part of modern buildings,centralized central air conditioning systems play an important role in maintaining the comfort and air quality of the indoor environment.However,with the increasing energy ...As an indispensable part of modern buildings,centralized central air conditioning systems play an important role in maintaining the comfort and air quality of the indoor environment.However,with the increasing energy consumption,how to improve the energy efficiency ratio of air conditioning systems and reduce energy consumption has become an important issue in research and practice.The purpose of this paper is to discuss the impact of humidity control strategies on energy saving in centralized central air conditioning systems,with a view to providing a theoretical basis and practical guidance for realizing building energy efficiency.展开更多
In the background of reform of higher education in the new era,how to organically integrate innovation and entrepreneurship education with curriculum ideology and politics has become a key proposition for deepening th...In the background of reform of higher education in the new era,how to organically integrate innovation and entrepreneurship education with curriculum ideology and politics has become a key proposition for deepening the reform of education and teaching.As an important branch in the field of engineering,the refrigeration and air conditioning major not only undertakes the professional mission of cultivating technical talents in the industry,but also shoulders the era responsibility of implementing the fundamental task of cultivating morality and talents.Combining with the characteristics of the refrigeration and air conditioning major,this paper systematically analyzes the internal logic and practical significance of the integration of innovation and entrepreneurship education and curriculum ideology and politics,and explores its implementation paths in aspects such as the excavation of curriculum content,the innovation of teaching methods,the construction of practical platforms and the optimization of evaluation systems.It aims to provide practical reference and theoretical support for promoting the collaborative education of professional education and ideological and political education.展开更多
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr...This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us.展开更多
An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning sy...An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning system,called the ultra-high-temperature instantaneous sterilization air conditioning system(UHTACS),is proposed.Based on the proposed system,a simulation of the UHT-ACS is analysed in various flight states.In the UHT-ACS,the mixing air temperature of return and bleed air can reach temperature up to 148.8°C,which is high enough to kill bacilli and viruses in 2一8 s.The supply air temperature of the UHT-ACS in a mixing cavity is about 12 C in cooling mode both on the ground and in the air.The supply air temperature is about 42 C in heating mode.Compared with the air conditioning systems(ACS)of traditional aircraft the supply air temperatures of the UHT-ACS in the mixing cavity are in good agreement with those of a traditional ACS with 60%fresh air and 40%return air.Furthermore the air temperature at the turbine outlet of the UHT-ACS is higher than that of a traditional ACS which will help to reduce the risk of icing at the outlet.Therefore the UHT-ACS can operate normally in various flight states.展开更多
Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy...Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively.展开更多
A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of...A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available.展开更多
The vast potential of system health monitoring and condition based maintenance on modern commercial aircraft is being realized through the innovative use of Airplane Condition Monitoring System(ACMS) data.However ther...The vast potential of system health monitoring and condition based maintenance on modern commercial aircraft is being realized through the innovative use of Airplane Condition Monitoring System(ACMS) data.However there are few methods addressing the issues of failure prognostics and predictive maintenance for commercial aircraft Air Conditioning System(ACS).This study developed a Bayesian failure prognostics approach using ACMS data for predictive maintenance of ACS.First, a health index characterizing the ACS health state is inferred from a multiple sensor signals using a data driven method.Then a dynamic linear model is proposed to describe the degradation process for failure prognostics.Bayesian inference formulas are carried out for degradation estimation and prediction.The developed approach is applied on a passenger aircraft fleet with ACMS data recorded for one year.The analysis of the case study shows that the developed method can produce satisfactory prognostics results, where all the ACS failure precursors are identified in advance, and the relative errors for the failure time prediction made when just entering the degradation warning stage are less than 8%.This would allow operators to proactively plan future maintenance.展开更多
In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large e...In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large eddy simulation.In this way,the aerodynamic source for noise generation has initially been determined.Then,the far-field aerodynamic noise has been computed in the framework of the Lighthill’s acoustics analogy theory.The propulsion height and flow-guide angle of the roof air conditioner were set as the design variables.According to the computational results,a lower propulsion height or flow-guide angle is beneficial in terms of aerodynamic drag and noise mitigation.However,compared to the design scheme with propulsion height of 0mm,the aerodynamic drag coefficient of the configuration with propulsion height of 190mm and flow-guide angle of 30°is slightly larger,while the aerodynamic noise is obviously reduced.Thus,from the viewpoint of the aerodynamic drag and noise,the design scheme with propulsion height of 190 mm and flow-guide angle of 30°is the optimal configuration in the range of conditions examined in the present work.展开更多
In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) ...In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) and heat flow rate Qout which is released into the room as the optimization objectives,we discuss the applicabilities of the entropy generation minimization and entransy theory to the optimizations.Five numerical cases are presented.Combining the numerical results and theoretical analyses,we can conclude that the optimization applicabilities of the two theories are conditional.If Qout is the optimization objective,larger entransy increase rate always leads to larger Qout,while smaller entropy generation rate does not.If we take COP as the optimization objective,neither the entropy generation minimization nor the concept of entransy increase is always applicable.Furthermore,we find that the concept of entransy dissipation is not applicable for the discussed cases.展开更多
Currently, the refrigerant used in the automotive air conditioning system is R134 a which has a high global warming potential(GWP) value, so people are eager to find a good replacement for it. According to recent stud...Currently, the refrigerant used in the automotive air conditioning system is R134 a which has a high global warming potential(GWP) value, so people are eager to find a good replacement for it. According to recent studies, R1234 yf is considered as one of the top candidates to replace R134 a. In this article, the performances of R1234 yf "drop-in" system and the optimization to the R1234 yf system are experimentally studied and investigated.The expansion valve used for the R1234 yf system is optimized by changing the charged fluid and adjusting the spring force. The results indicate that it can improve the performance of R1234 yf system significantly through adjusting the thermostatic expansion valve. For the thermostatic expansion valves(TEVs) charged with R134 a in thermal bulb, the system performance is optimal. Compared to the original expansion valve, for the R1234 yf system applying the adjusted expansion valves, under different working conditions the cooling capacity increases by 11.3% averagely and the coefficient of performance(COP) increases by 8% averagely.展开更多
Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study co...Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted.展开更多
High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial asp...High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop.展开更多
A model free intelligent muhivariable fuzzy controller (MFC) designed for modulating the vapor compression cycles in a residential inverter-driven air conditioning is proposed. The novel controller combines a tradit...A model free intelligent muhivariable fuzzy controller (MFC) designed for modulating the vapor compression cycles in a residential inverter-driven air conditioning is proposed. The novel controller combines a traditional fuzzy controller (TFC) and an additional coupling fuzzy controller, the coupling fuzzy controller is introduced to compensate for the unknown cross-coupling effects of this muhivariable system. In order to evaluate the control performance of the MFC, it is digitally implemented in terms of regulating the desired evaporating temperature and superheat. The experimental results show the effectiveness of the MFC for improvement of system performance and energy efficiency.展开更多
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera...Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.展开更多
According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both uprig...According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both upright and 45 ° incline service positions. And some key technologies were researched, such as structural design of machine body, reliable conduction of rotary weldments and quality control of welding process and so on. The experimental results showed that this machine could satisfy the requirements of welding quality and girth welding technology, results also proved the machine was a high-effwiency and low-cost automatic welding device.展开更多
Air conditioning (AC) system is the one with asynchronous and uncertain nature. In this paper, the fuzzy discrete event system (FDES) is introduced to the research of AC energy-saving control. A fuzzy automaton modeli...Air conditioning (AC) system is the one with asynchronous and uncertain nature. In this paper, the fuzzy discrete event system (FDES) is introduced to the research of AC energy-saving control. A fuzzy automaton modeling is given for AC energy-saving control and effectiveness optimization is made. To facilitate the implement of the control and energy saving, priorities have been assigned to the major control steps based on logical reasoning. Forward-looking tree modeling based on FDES has been simplified to help further optimization, and a simple and concrete example has been put forward illustrating energy-saving control in AC system.展开更多
基金supported by Supported by the Scientific Research Foundation for High-Level Talents of Zhoukou Normal University(ZKNUC2024018).
文摘Energy shortage has become one of themost concerning issues in the world today,and improving energy utilization efficiency is a key area of research for experts and scholars worldwide.Small-diameter heat exchangers offer advantages such as reduced material usage,lower refrigerant charge,and compact structure.However,they also face challenges,including increased refrigerant pressure drop and smaller heat transfer area inside the tubes.This paper combines the advantages and disadvantages of both small and large-diameter tubes and proposes a combined-diameter heat exchanger,consisting of large and small diameters,for use in the indoor units of split-type air conditioners.There are relatively few studies in this area.In this paper,A theoretical and numerical computation method is employed to establish a theoretical-numerical calculation model,and its reliability is verified through experiments.Using this model,the optimal combined diameters and flow path design for a combined-diameter heat exchanger using R32 as the working fluid are derived.The results show that the heat transfer performance of all combined diameter configurations improves by 2.79%to 8.26%compared to the baseline design,with the coefficient of performance(COP)increasing from 4.15 to 4.27~4.5.These designs can save copper material,but at the cost of an increase in pressure drop by 66.86%to 131.84%.The scheme IIIH,using R32,is the optimal combined-diameter and flow path configuration that balances both heat transfer performance and economic cost.
文摘Thermoelectric air conditioning systems based on the Peltier effect had two modes:heating and cooling.In this work,the proposed design provides continuous improvement in COP from the first minute of operation.In cooling mode,the coefficient of performance(COP)was 1.176 due to the techniques used in this device,and it increased to 1.24 in the last minute of operation.Concerning the steady-state scenario,from the first minute,the Qc was larger than the W for the entire duration of the operation.The output temperature reaches 18.97℃ ,and the temperature on the cold side reaches 4.96℃ in the fifteen minutes of operation.The cooling mood was checked in Iraq/Baghdad in October with a temperature of 31℃ .Furthermore,the heating mode was checked in December with a temperature of 22℃ .Due to the size of the component on the cold side being small compared with the size of the component on the heat side,it reached a steady state in 13 min.This means the COP in heating mode reached 1.01 in 14 min.Furthermore,due to the presence of a thermal insulator made inside the device to separate the cold side and the hot side,the difference in temperature causes a noticeable little ascent.This is why the COP increased because it kept the degree differences low.Performance enhancements were achieved by optimizing the behavior of thermoelectric materials.The device contains 3 Peltier elements,a water-cooled system with one Peltier,a heat sink,and a fan.The design of the dehumidification system addresses the humidity issue commonly associated with thermoelectric air conditioners.In this context,the results indicate that the humidity rates had decreased and the cooling rate had increased with these innovative techniques,and thus,excellent performance can be achieved even if the Seebeck coefficient is not at its highest based on the condition of providing the Peltier elements’reliability and optimal thermal performance for various applications requiring both cooling and heating functions.The insulation plays a critical role in maintaining the efficiency of the system,reducing energy consumption,and ensuring long-term functionality.The proposed system is valuable for devices or environments that demand precise and dual thermal control with minimal energy wastage.
文摘The energy consumption of a Split air conditioning unit(ACU)inside a building is extremely large,and efforts to decrease this issue are ongoing.The current work aims to experimentally investigate the thermal performance of ACU using an external cooling-water loop for pre-cooling the condenser to improve the efficiency and to reduce energy consumption by reducing refrigerant temperature before entering the condenser,thereby reducing the coefficient of performance.The experiments are performed on ACU with and without using an external cooling-water loop under different climate conditions.By using the experimental data,the systems’performances for both cases are evaluated based on the energy,exergy,and pressure drop analysis.Effects of several parameters,e.g.,ambient temperature,inlet water temperature,and water volume flow rate,on the energy and exergy performances of ACU systems are presented for the purpose of comparison.The outcomes display that the use of an external cooling water loop system has a significant impact on the system performance as compared to conventional ACU.The results display that the addition of an external cooling-water loop leads to a reduction in the compressor power consumption and to an increase in the coefficient of performance(COP)as compared to a normal ACU.The maximum reduction in compressor power consumption is obtained equal 37%at T_(w)=15℃and 11 L/min,whereas the maximum enhancement in COP is obtained equal 21.5%at T_(w)=30℃,11 L/min,and T_(amb)=45℃.The modified model shows an increase in exergy efficiency with the maximum enhancement of about 17%at T_(w)=30℃and 15.8 L/min.The use of an external cooling water loop leads to a reduction in the irreversibility process of the compressor,evaporator and expansion valve and to an increase in the condenser losses.The outcomes show that the pressure drop is reduced by using a cooling water loop as compared to a normal ACU,where the reduction becomes more evident with a reduction in water volume flow rate and inlet temperature.Finally,the present study reveals that the use of an external cooling water loop system leads to an improvement in the performance of ACUs.
文摘LDACs(liquid desiccant air-conditioners)with heat pump can perform cooling dehumidification or heating humidification,and have high energy-saving and sterilization performance.Therefore,they are installed in hospitals,nursing homes,and food factories,where humidity control is required.However,LiCl(lithium chloride),a conventional humidity control liquid,is highly corrosive to metals,requiring the use of highly corrosion-resistant materials for the pipes and the heat exchangers.These lead to the problem that the manufacturing cost of the air conditioner increases.Therefore,we developed an inexpensive and compact LDAC by adopting a novel IL(ionic liquid)that does not corrode the metals commonly used in air conditioners.In this study,we evaluated the metal solubilities and sterilizing properties of the IL.Based on the physical properties of the IL,the humidity control module was improved for the purpose of downsizing and cost reduction of the unit.Moreover,we conducted a performance evaluation of the LDAC in the environmental test room under the condition in which temperature and humidity change rapidly in short period of time to simulate the condition of sudden showers of rain in summer.Test results showed that processed air was supplied at very stable level.
文摘As an indispensable part of modern buildings,centralized central air conditioning systems play an important role in maintaining the comfort and air quality of the indoor environment.However,with the increasing energy consumption,how to improve the energy efficiency ratio of air conditioning systems and reduce energy consumption has become an important issue in research and practice.The purpose of this paper is to discuss the impact of humidity control strategies on energy saving in centralized central air conditioning systems,with a view to providing a theoretical basis and practical guidance for realizing building energy efficiency.
基金Undergraduate Teaching Research and Reform Project of the University of Shanghai for Science and Technology(Project No.:JGXM202526)。
文摘In the background of reform of higher education in the new era,how to organically integrate innovation and entrepreneurship education with curriculum ideology and politics has become a key proposition for deepening the reform of education and teaching.As an important branch in the field of engineering,the refrigeration and air conditioning major not only undertakes the professional mission of cultivating technical talents in the industry,but also shoulders the era responsibility of implementing the fundamental task of cultivating morality and talents.Combining with the characteristics of the refrigeration and air conditioning major,this paper systematically analyzes the internal logic and practical significance of the integration of innovation and entrepreneurship education and curriculum ideology and politics,and explores its implementation paths in aspects such as the excavation of curriculum content,the innovation of teaching methods,the construction of practical platforms and the optimization of evaluation systems.It aims to provide practical reference and theoretical support for promoting the collaborative education of professional education and ideological and political education.
文摘This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us.
基金the Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)and the Foundation of Jiangsu Postdoctoral(No.2019K126)。
文摘An aircraft cabin is a narrow,closed-space environment.To keep the air quality in cabin healthy for passengers,especially during an epidemic such as SARS-CoV-2(or 2019-nCoV)in 2020,a novel aircraft air conditioning system,called the ultra-high-temperature instantaneous sterilization air conditioning system(UHTACS),is proposed.Based on the proposed system,a simulation of the UHT-ACS is analysed in various flight states.In the UHT-ACS,the mixing air temperature of return and bleed air can reach temperature up to 148.8°C,which is high enough to kill bacilli and viruses in 2一8 s.The supply air temperature of the UHT-ACS in a mixing cavity is about 12 C in cooling mode both on the ground and in the air.The supply air temperature is about 42 C in heating mode.Compared with the air conditioning systems(ACS)of traditional aircraft the supply air temperatures of the UHT-ACS in the mixing cavity are in good agreement with those of a traditional ACS with 60%fresh air and 40%return air.Furthermore the air temperature at the turbine outlet of the UHT-ACS is higher than that of a traditional ACS which will help to reduce the risk of icing at the outlet.Therefore the UHT-ACS can operate normally in various flight states.
基金support and facilities provieded by Bharat Sanchar Nigam Limited Chennai Telephones and Department of Telecommunications,India for this study
文摘Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively.
文摘A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available.
基金supported by National Natural Science Foundation of China(91860139)China Postdoctoral Science Foundation(2015M581792)。
文摘The vast potential of system health monitoring and condition based maintenance on modern commercial aircraft is being realized through the innovative use of Airplane Condition Monitoring System(ACMS) data.However there are few methods addressing the issues of failure prognostics and predictive maintenance for commercial aircraft Air Conditioning System(ACS).This study developed a Bayesian failure prognostics approach using ACMS data for predictive maintenance of ACS.First, a health index characterizing the ACS health state is inferred from a multiple sensor signals using a data driven method.Then a dynamic linear model is proposed to describe the degradation process for failure prognostics.Bayesian inference formulas are carried out for degradation estimation and prediction.The developed approach is applied on a passenger aircraft fleet with ACMS data recorded for one year.The analysis of the case study shows that the developed method can produce satisfactory prognostics results, where all the ACS failure precursors are identified in advance, and the relative errors for the failure time prediction made when just entering the degradation warning stage are less than 8%.This would allow operators to proactively plan future maintenance.
基金supported by the National Key R&D Program of China(No.2016YFB1200504-F)the National Natural Science Foundation of China(No.51705267)+1 种基金the China Postdoctoral Science Foundation(No.2018M630750)the China Railway R&D Program(No.2015J009-D).
文摘In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large eddy simulation.In this way,the aerodynamic source for noise generation has initially been determined.Then,the far-field aerodynamic noise has been computed in the framework of the Lighthill’s acoustics analogy theory.The propulsion height and flow-guide angle of the roof air conditioner were set as the design variables.According to the computational results,a lower propulsion height or flow-guide angle is beneficial in terms of aerodynamic drag and noise mitigation.However,compared to the design scheme with propulsion height of 0mm,the aerodynamic drag coefficient of the configuration with propulsion height of 190mm and flow-guide angle of 30°is slightly larger,while the aerodynamic noise is obviously reduced.Thus,from the viewpoint of the aerodynamic drag and noise,the design scheme with propulsion height of 190 mm and flow-guide angle of 30°is the optimal configuration in the range of conditions examined in the present work.
基金Project supported by the Youth Programs of Chongqing Three Gorges University,China(Grant No.13QN18)
文摘In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) and heat flow rate Qout which is released into the room as the optimization objectives,we discuss the applicabilities of the entropy generation minimization and entransy theory to the optimizations.Five numerical cases are presented.Combining the numerical results and theoretical analyses,we can conclude that the optimization applicabilities of the two theories are conditional.If Qout is the optimization objective,larger entransy increase rate always leads to larger Qout,while smaller entropy generation rate does not.If we take COP as the optimization objective,neither the entropy generation minimization nor the concept of entransy increase is always applicable.Furthermore,we find that the concept of entransy dissipation is not applicable for the discussed cases.
基金the National Key Technologies Research and Development Program of China During the 12th Five-Year Plan Period(No.SQ2011GX03D03999)
文摘Currently, the refrigerant used in the automotive air conditioning system is R134 a which has a high global warming potential(GWP) value, so people are eager to find a good replacement for it. According to recent studies, R1234 yf is considered as one of the top candidates to replace R134 a. In this article, the performances of R1234 yf "drop-in" system and the optimization to the R1234 yf system are experimentally studied and investigated.The expansion valve used for the R1234 yf system is optimized by changing the charged fluid and adjusting the spring force. The results indicate that it can improve the performance of R1234 yf system significantly through adjusting the thermostatic expansion valve. For the thermostatic expansion valves(TEVs) charged with R134 a in thermal bulb, the system performance is optimal. Compared to the original expansion valve, for the R1234 yf system applying the adjusted expansion valves, under different working conditions the cooling capacity increases by 11.3% averagely and the coefficient of performance(COP) increases by 8% averagely.
基金Research Project of China Ship Development and Design Center。
文摘Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted.
文摘High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop.
基金This work is supported by the National High Technology Research and Development Program of China (863 Programs, GrantNo. 2007AA05Z224)Knowledge Innovation Project of Chinese Academy of Sciences(Grant No.KGCX2-YW-345)Zhejiang Scientific and Technological Project(Grant No.2009C3113004)
文摘A model free intelligent muhivariable fuzzy controller (MFC) designed for modulating the vapor compression cycles in a residential inverter-driven air conditioning is proposed. The novel controller combines a traditional fuzzy controller (TFC) and an additional coupling fuzzy controller, the coupling fuzzy controller is introduced to compensate for the unknown cross-coupling effects of this muhivariable system. In order to evaluate the control performance of the MFC, it is digitally implemented in terms of regulating the desired evaporating temperature and superheat. The experimental results show the effectiveness of the MFC for improvement of system performance and energy efficiency.
文摘Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.
文摘According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both upright and 45 ° incline service positions. And some key technologies were researched, such as structural design of machine body, reliable conduction of rotary weldments and quality control of welding process and so on. The experimental results showed that this machine could satisfy the requirements of welding quality and girth welding technology, results also proved the machine was a high-effwiency and low-cost automatic welding device.
基金PhD Programs Foundation of Ministry of Education of China( No.20060255006)Cultivation Fund of the Key Scientific and Technical Innovation Project from Ministry of Education of China (No.706024)
文摘Air conditioning (AC) system is the one with asynchronous and uncertain nature. In this paper, the fuzzy discrete event system (FDES) is introduced to the research of AC energy-saving control. A fuzzy automaton modeling is given for AC energy-saving control and effectiveness optimization is made. To facilitate the implement of the control and energy saving, priorities have been assigned to the major control steps based on logical reasoning. Forward-looking tree modeling based on FDES has been simplified to help further optimization, and a simple and concrete example has been put forward illustrating energy-saving control in AC system.