Ammonium Salt Deposition Characteristics in an Air Cooler System Based on the Coupling of Fluid Flow and Heat Transfer Simulation 被引量:5
1
作者 Jin Haozhe Zhou Junfeng +2 位作者 Liu Wenwen Liu Xiaofei Ou Guofu 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2019年第4期94-102,共9页
The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations we... The ammonium salt corrosion is a typical failure mode for the hydrogenation reaction effluent air cooler(REAC) system. In order to investigate the corrosion characteristics in the REAC system, numerical simulations were performed by using the mixture model, the heating transfer model, and the particles tracking model. The results show that the differences between the temperature and the velocity at each cross section of the first-row and second-row tubes are small. The inertia of the particles plays an important role in the particle’s deposition, and the smaller particles distribute more uniformly in the air cooler. However, for larger particles, they prefer falling from the inner side of the vertical elbow, and preferentially depositing at the inlet header and pipes before saturation. In the heat exchanger tubes, the particle deposition number is larger in the second-row tubes than that in the first-row tubes, and the high-risk tubes mainly concentrate on the middle and right side of the air cooler. The kinetic parameters of the particles are in accordance with the blocking-prone position in many real operating conditions. 展开更多
关键词 hydrogenation air cooler multiphase flow ammonium salt corrosion particles drifting
在线阅读 下载PDF
Experimental and Numerical Investigation on Erosion Corrosion of the Air Cooler Tube Bundle in a Residue Hydrotreating Unit 被引量:4
2
作者 Jin Haozhe Yu Chenyang +4 位作者 Gu Youjie Qian Guangwei Liu Xiaofei Ou Guofu Jia Yongna 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2022年第4期151-162,共12页
Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the ... Corrosion leakage occurred in the 14th tube bundle in the first row of a residual oil hydrotreating air cooler after operating for two years.The failure location was 0.5 m from the outlet header box.In this paper,the erosion corrosion of the air cooler tube bundle was investigated by experimental and numerical methods.Visual inspection,scanning electron microscopy(SEM),and X-ray diffraction(XRD)experiments were performed,and the failure morphology and material composition confirmed that the damage was caused by erosion corrosion.The shear stress transport k–ωturbulence model(SST-k–ω)was then used to investigate the flow and erosion corrosion characteristics,combined with mass transfer,corrosion rate,and ionization equilibrium models.The numerical simulation results revealed that the water phase volume fraction increased with flow and heat transfer in the fluid,which increased the mass flow rate and concentration of hydrogen sulfide.The mass transfer coefficient and corrosion rate were proposed as important parameters to characterize erosion corrosion.Moreover,the local concentration of wall shear stress was found to increase the risk of erosion corrosion.The predicted high-risk area was consistent with the actual failure area,which verified that this failure incident was attributable to erosion corrosion by the water phase. 展开更多
关键词 erosion corrosion air cooler tube bundle(ACTB) RESIDUE THINNING hydrogen sulfide
在线阅读 下载PDF
Functional Link Neural Network for Predicting Crystallization Temperature of Ammonium Chloride in Air Cooler System 被引量:3
3
作者 Jin Haozhe Gu Yong +3 位作者 Ren Jia Wu Xiangyao Quan Jianxun Xu Linfengyi 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2020年第2期86-92,共7页
The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temper... The air cooler is an important equipment in the petroleum refining industry.Ammonium chloride(NH4 Cl)deposition-induced corrosion is one of its main failure forms.In this study,the ammonium salt crystallization temperature is chosen as the key decision variable of NH4 Cl deposition-induced corrosion through in-depth mechanism research and experimental analysis.The functional link neural network(FLNN)is adopted as the basic algorithm for modeling because of its advantages in dealing with non-linear problems and its fast-computational ability.A hybrid FLNN attached to a small norm is built to improve the generalization performance of the model.Then,the trained model is used to predict the NH4 Cl salt crystallization temperature in the air cooler of a sour water stripper plant.Experimental results show the proposed improved FLNN algorithm can achieve better generalization performance than the PLS,the back propagation neural network,and the conventional FLNN models. 展开更多
关键词 air cooler NH4Cl salt crystallization temperature DATA-DRIVEN functional link neural network particle swarm optimization
在线阅读 下载PDF
Analysis of the Erosion-Corrosion Mechanism of the Air Cooler in a Hydrocracking Unit:A Numerical and Experimental Study
4
作者 Su Guoqing Li Yan +1 位作者 Guo Hongli Zhang Jianwen 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2024年第1期126-138,共13页
Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirm... Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation. 展开更多
关键词 air cooler hydrocracking unit EROSION-CORROSION SIMULATION visualization experiment multiphase flow
在线阅读 下载PDF
Pressure drop of the film-enlarged tube bundles in air-water two-phase cross flow in evaporative air cooler
5
作者 LIU Jia-ni ZHOU Li WANG Jun 《Journal of Energy and Power Engineering》 2009年第3期53-58,共6页
An experiment was carried out to investigate the relation of the maximum velocity of air passing through narrowest passage, mass flux of spray water in one square meter in one hour and the pressure drop of tube bundle... An experiment was carried out to investigate the relation of the maximum velocity of air passing through narrowest passage, mass flux of spray water in one square meter in one hour and the pressure drop of tube bundles. Twelve equations were obtained for the relation. The results show that the pressure drop of the tube bundles increases with increase of the maximum velocity of air and the mass flux of spray water. Comparing the pressure drop of the bare tube bundles with that of the film-enhanced tube bundles, it is found that the pressure drop of the film-enhanced tube bundles is lower about 11% and the surface roughness of the film-enhanced plates is a main factor that influences the pressure drop. The data and method obtained in the paper can be used to compute the pressure drop of the film-enhanced tube bundles and is helpful for selection of fan. 展开更多
关键词 pressure drop velocity of air mass flux of spray water air cooler
在线阅读 下载PDF
Application of Taguchi Method for the Optimization of System Parameters of Centrifugal Evaporative Air Cooler 被引量:6
6
作者 K.Senthilkumar PSS.Srinivasan 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第5期473-479,共7页
A new evaporative cooling system based on the action of centrifugal forces is proposed.Such systems are suitable for cooling large air volumes in tropical climates.Effects of geometrical and operational parameters on ... A new evaporative cooling system based on the action of centrifugal forces is proposed.Such systems are suitable for cooling large air volumes in tropical climates.Effects of geometrical and operational parameters on system performance are optimized using Taguchi method.It is observed that disc speed,air flow rate and water flow rate are found to have major influence on system performance and other parameter,viz.,disc diameter,pin geometry,evaporation chamber length and orientation of pin have less influence. 展开更多
关键词 HUMIDIFIER Evaporative air cooler Centrifugal force Taguchi method
原文传递
Enhancing Evaporative Cooler Efficiency through Magnetized Water and Heat Exchanger Optimization
7
作者 Mohammed J.Alshukri Amjed Al-Khateeb +2 位作者 Ahmed Mohsin Alsayah Adel A.Eidan Hameed B.Mahood 《Energy Engineering》 2025年第4期1359-1372,共14页
This research presents a new method to boost the efficiency of evaporative coolers by integrating magnetized water and a heat exchanger.Magnetized water,known for its high evaporation rate and reduced surface tension,... This research presents a new method to boost the efficiency of evaporative coolers by integrating magnetized water and a heat exchanger.Magnetized water,known for its high evaporation rate and reduced surface tension,offers a promising way to enhance air cooler performance.Additionally,the advanced heat exchanger both improves air cooling capacity and controls humidity levels.Aloni 100 L,a locally manufactured evaporative cooling system,and tap water were used in experiments.Tap water was magnetized using recycled magnets extracted from computer hard drives.Twenty-six magnets meticulously arranged within rectangular grooves,each with a minimum strength of 0.5 to 1T,were used tomagnetize tapwater.Our experiments showa significant rise in cooling efficiency,with magnetized water increasing from 70.62%to 91.43%.In a similar vein,adding the heat exchanger leads to a significant improvement,raising the cooling efficiency from 69.44%to 93.96%.Furthermore,the combined use of magnetized water and a heat exchanger results in exceptional performance,increasing cooling efficiencies by 29.5%and 35.3%compared to using only magnetized water or only a heat exchanger,respectively.This study also explores the largely untapped potential of magnetized water,providing valuable insights into its effects on water properties and its broader applications in various fields.These findings represent a significant advancement in air cooling technology and pave the way for more energy-efficient and sustainable solutions. 展开更多
关键词 Evaporative cooling magnetized water heat exchanger air cooler subtropical weather
在线阅读 下载PDF
空冷器能效评价模型研究
8
作者 苏厚德 刘绍东 +3 位作者 王秋萍 李亚军 张津铭 赵伟刚 《石油化工设备》 2026年第1期11-16,共6页
针对油田空冷器能效评价缺乏系统性方法与标准指标的问题,为提高能源利用效率,基于热力学第一、第二定律,构建融合总传热系数、压降与[火用]效率的综合能效评价模型。通过文献调研与HTRI软件在多工况下的模拟分析,确定模型关键无量纲指... 针对油田空冷器能效评价缺乏系统性方法与标准指标的问题,为提高能源利用效率,基于热力学第一、第二定律,构建融合总传热系数、压降与[火用]效率的综合能效评价模型。通过文献调研与HTRI软件在多工况下的模拟分析,确定模型关键无量纲指数m=0.107、n=0.504,计算得出在流速1 m/s工况下,热流体进口温度90℃(出口70℃)与80℃(出口60℃)时,能效指标(EEI)分别达到峰值7.182和7.815。采集油田实测数据,对比模拟值与实测值验证模型可靠性,负荷、压降、总传热系数相对误差均小于5%。结果表明,所提出的EEI指标能够同时反映能量质与量的利用效率,优于传统单耗评价方法。研究可为空冷器运行优化、节能改造及能效标识分级提供理论参考与技术支撑。 展开更多
关键词 空冷器 能效评价 [火用]分析 HTRI模拟 优化运行
在线阅读 下载PDF
跨临界CO_(2)驻车热泵空调最优排气压力研究
9
作者 刘业凤 钟海辉 +3 位作者 罗志鹏 李洁 丁民淅 张华 《暖通空调》 2026年第3期86-90,65,共6页
以带回热器的跨临界CO_(2)热泵空调系统为基础,设计搭建了跨临界CO_(2)驻车热泵空调系统实验台,通过控制车内回风温度、压缩机频率和车内送风量等参数,研究了跨临界CO_(2)驻车热泵空调的最优排气压力。结果表明:跨临界CO_(2)系统对欠排... 以带回热器的跨临界CO_(2)热泵空调系统为基础,设计搭建了跨临界CO_(2)驻车热泵空调系统实验台,通过控制车内回风温度、压缩机频率和车内送风量等参数,研究了跨临界CO_(2)驻车热泵空调的最优排气压力。结果表明:跨临界CO_(2)系统对欠排气压力更为敏感,当车外环境温度为7℃,车内回风温度为20℃,车内、外风量分别为400 m^(3)/h和1000 m^(3)/h时,系统最优排气压力为7.77 MPa,该工况下将系统排气压力从7.42 MPa升至7.77 MPa,系统COP提升了1.1,而随着排气压力从7.77 MPa继续升高至9.41 MPa,COP仅下降了0.3;增大车内送风量可有效降低气冷器出口温度和最优排气压力,当车内送风量从300 m^(3)/h增大到400 m^(3)/h时,气冷器出口温度下降4℃,最优排气压力降低1.15 MPa;气冷器出口温度对最优排气压力的影响最为显著,当系统运行工况改变时,这2个参数总是同步变化;基于试验数据拟合了一个新的最优排气压力预测关联式,该关联式预测值与试验值的最大偏差仅为3.5%,准确性较高,可为跨临界CO_(2)热泵空调系统排气压力的控制提供参考,确保系统始终在最佳COP下运行。 展开更多
关键词 跨临界CO_(2)循环 热泵 驻车空调 最优排气压力 COP 关联式 气冷器出口温度
在线阅读 下载PDF
数据中心空气冷却器的通道传热强化技术研究
10
作者 王子星 陶文铨 《制冷学报》 北大核心 2026年第1期105-112,共8页
通过数值仿真方法研究了传统球冠丁胞以及3种新型丁胞(椭球冠形、圆角棒形、圆角梯形)在数据中心空气冷却器换热芯中应用的流动与传热强化特性,所研究Re范围为5728~11176。结果表明:传统球冠丁胞的传热强化能力有限,其最大PEC(性能评价... 通过数值仿真方法研究了传统球冠丁胞以及3种新型丁胞(椭球冠形、圆角棒形、圆角梯形)在数据中心空气冷却器换热芯中应用的流动与传热强化特性,所研究Re范围为5728~11176。结果表明:传统球冠丁胞的传热强化能力有限,其最大PEC(性能评价指标)为1.067(球冠丁胞R15h2,Re=8383)。而相较于球冠丁胞,3种新型丁胞通道中的高流速区域均更加靠近壁面,使得壁面边界层更薄,从而强化了传热。而在3种新型丁胞之间,通道上壁面处的近壁面高流速区域以及流体冲击效应使圆角棒形丁胞通道的传热能力优于椭球冠形丁胞,更加复杂的二次流漩涡使圆角梯形丁胞的传热能力优于圆角棒形丁胞。圆角梯形丁胞的传热强化效果最好,在等泵功下相较于平直板片通道最高可强化传热33%(Re=5728),而在测试Re范围内其PEC均大于1.27。 展开更多
关键词 数据中心 强化传热 丁胞结构 空气冷却器
在线阅读 下载PDF
干式空冷器在7℃水系统中的应用
11
作者 崔文虎 吕连仁 +1 位作者 赵永富 韩彬 《中国氯碱》 2026年第2期37-39,57,共4页
介绍了在7℃水回水总管增加一套空冷塔,利用北方冬季气温低的优势对回水进行空冷降温,达到节能降耗的目的。
关键词 换热 空冷器 蒸汽单耗
在线阅读 下载PDF
重整产物空冷改造后空冷蒸发预冷器性能解析
12
作者 李曰强 时法存 +5 位作者 张淑妹 高强 杨卫锋 丁鹏飞 张文龙 王金波 《山东化工》 2026年第3期196-199,共4页
重整产物空冷器冷后温度受环境温度影响变化较大,在7、8月份影响更大,夜间与中午的冷后温差达到10℃多,过高的冷后温度使得循环氢中烃类增加,循环氢的相对分子质量变重,造成空冷满负荷运行,且循环氢压缩机的3.5 MPa蒸汽用量增加。间接... 重整产物空冷器冷后温度受环境温度影响变化较大,在7、8月份影响更大,夜间与中午的冷后温差达到10℃多,过高的冷后温度使得循环氢中烃类增加,循环氢的相对分子质量变重,造成空冷满负荷运行,且循环氢压缩机的3.5 MPa蒸汽用量增加。间接蒸发式预冷器改造技术是利用现有空冷改造后实现原空冷进风温度的降低,增加有效传热对数温差,从而降低空冷的出口温度,实现空冷器冷却效率的提升,达到稳定生产及操作,节省3.5 MPa蒸汽和电耗的目的。本文对重整产物空冷进行了改造,增添了7套蒸发预冷器,对改造后的效能进行了标定验证。验证结果显示,改造后温度实现了自动平稳控制,节省了3.5 MPa蒸汽和电耗,实现了降本增效,并降低了操作强度,对于重整装置的安全平稳运行具有重要意义。 展开更多
关键词 重整产物空冷器 蒸发式预冷器 循环气 重整装置 3.5 MPa蒸汽
在线阅读 下载PDF
加氢装置高压空冷器腐蚀控制综合设计技术
13
作者 李书涵 《石油化工设备技术》 2026年第2期42-46,63,I0003,共7页
加氢装置是炼油厂原油加工的核心装置。随着加氢装置进料日趋劣质化(高硫、高氮、高氯)以及操作条件日益苛刻,其腐蚀风险和失效隐患显著加剧,其中高压空冷器的腐蚀失效问题已成为行业面临的难题和痛点。文章针对某炼厂蜡油加氢精制装置... 加氢装置是炼油厂原油加工的核心装置。随着加氢装置进料日趋劣质化(高硫、高氮、高氯)以及操作条件日益苛刻,其腐蚀风险和失效隐患显著加剧,其中高压空冷器的腐蚀失效问题已成为行业面临的难题和痛点。文章针对某炼厂蜡油加氢精制装置进料提氮后对热高分气空冷器的影响展开分析,通过系统的腐蚀评估与核算,从材料选择、工艺防腐、腐蚀监检测等方面进行了全方位的腐蚀控制综合设计,提出了有效的防腐蚀策略,为保障加氢装置高压空冷器的长周期安全稳定运行提供了有力支撑。 展开更多
关键词 加氢装置 高压空冷器 材料选择 工艺防腐 腐蚀监检测 综合设计
在线阅读 下载PDF
板翅式空冷器泄漏失效模式与现场快速修复技术研究
14
作者 李磊 魏金民 +2 位作者 张硕硕 赵福栋 戴崴 《电力系统装备》 2026年第2期122-125,共4页
针对板翅式空冷器泄漏导致的冷却系统失效及设备跳闸问题,文章深入分析了其行业应用痛点及全生命周期内诱发泄漏失效的关键风险要素。基于工程实践,提出并验证了一套高效、经济的快速修复方案。文章聚焦于现场运行环境适应性、修复材料... 针对板翅式空冷器泄漏导致的冷却系统失效及设备跳闸问题,文章深入分析了其行业应用痛点及全生命周期内诱发泄漏失效的关键风险要素。基于工程实践,提出并验证了一套高效、经济的快速修复方案。文章聚焦于现场运行环境适应性、修复材料性能(含固化特性)、修复后可靠性、设备使用寿命延长及停机时间最小化等核心要素,通过关键试验与实际工程应用验证方案的有效性。研究表明,该方案可将停机时间缩短至15 h内,修复成本较传统更换方案降低99%以上,修复后设备运行稳定,散热性能满足要求,为水冷却系统中板翅式空冷器泄漏故障提供了一种低成本快速修复技术路径。 展开更多
关键词 板翅式空冷器 泄漏修复 氩弧焊 高强度环氧胶 可靠性验
在线阅读 下载PDF
加氢装置反应馏出物空冷器腐蚀分析与防护
15
作者 程传裕 《石油化工腐蚀与防护》 2026年第1期42-45,60,共5页
反应馏出物空冷器(REAC)是加氢装置中腐蚀风险最高的设备之一,其失效将导致装置非计划停工甚至安全事故。该文系统分析了反应馏出物空冷器的腐蚀环境与机理,指出其主要面临酸性水腐蚀、湿H2S破坏、铵盐垢下腐蚀及冲刷腐蚀四类损伤,其中... 反应馏出物空冷器(REAC)是加氢装置中腐蚀风险最高的设备之一,其失效将导致装置非计划停工甚至安全事故。该文系统分析了反应馏出物空冷器的腐蚀环境与机理,指出其主要面临酸性水腐蚀、湿H2S破坏、铵盐垢下腐蚀及冲刷腐蚀四类损伤,其中铵盐(NH4Cl/NH4HS)析出后在露点部位形成局部的强酸性环境,最易导致空冷器的腐蚀失效。从工艺防腐和设备防腐两方面提出空冷器的腐蚀防护方案,注水作为最普遍且行之有效的工艺防腐手段,要保证注水量和注水水质,并以合理选材、流速设计和制造检验质量保证作为设备防腐的方案。该研究为加氢装置反应馏出物空冷器腐蚀分析与防护提供了工程参考。 展开更多
关键词 加氢装置 反应馏出物空冷器 湿H2S腐蚀 铵盐垢下腐蚀 注水 材料选择
在线阅读 下载PDF
乘员舱侧蒸发-气冷双用型CO_(2)微通道换热器传热与压降特性研究
16
作者 魏嘉祺 武卫东 +2 位作者 黄逸宸 陈浪 冯杰 《汽车工程师》 2026年第2期9-14,20,共7页
为研究乘员舱侧蒸发-气冷双用型微通道换热器在不同工况下的运行特性,基于Dymola平台构建了该换热器的一维仿真模型并验证了其可靠性,分析了在热泵(HP)模式下不同制冷剂和空气的入口参数对微通道换热器换热及压降性能的影响,结果表明,... 为研究乘员舱侧蒸发-气冷双用型微通道换热器在不同工况下的运行特性,基于Dymola平台构建了该换热器的一维仿真模型并验证了其可靠性,分析了在热泵(HP)模式下不同制冷剂和空气的入口参数对微通道换热器换热及压降性能的影响,结果表明,适当增大制冷剂入口压力和换热器进风风量均能在增加换热量的同时减小制冷剂侧的压降:制冷剂入口压力每升高0.5 MPa,换热量平均增加2.6%,制冷剂侧压降平均降低9.5%;空气侧进风风量的增大及进风温度的降低均能在增加换热量的同时减小压降,但两者也均会降低出风温度。 展开更多
关键词 汽车空调 蒸发-气冷双用型换热器 CO_(2)热泵系统 传热性能 压降
在线阅读 下载PDF
21000 m^(3)/h制氧机组的空分冷却器节能改造实践
17
作者 丁炼军 颜昱东 +1 位作者 颜雄伟 王帅 《节能》 2026年第1期90-94,共5页
针对涟钢21 000 m^(3)/h制氧机组在高温季节出现的级间冷却阻力增大、流量受限及单位能耗上升等问题,实施以更换一、二级冷却器芯体及优化运行策略为核心的节能改造。结果显示,改造后,空压机入口流量平均值由106 273 m^(3)/h提高至120 6... 针对涟钢21 000 m^(3)/h制氧机组在高温季节出现的级间冷却阻力增大、流量受限及单位能耗上升等问题,实施以更换一、二级冷却器芯体及优化运行策略为核心的节能改造。结果显示,改造后,空压机入口流量平均值由106 273 m^(3)/h提高至120 625 m^(3)/h;进塔流量平均值由97 761 m^(3)/h增至109 900 m^(3)/h;一级冷却器压降平均值由28.13 kPa降低至4.76 kPa;排气压力上升5.14%;制氧单耗平均值由0.762 kWh/m^(3)降低至0.719 kWh/m^(3)。该项目实现月度综合效益约163万元,静态投资回收期约0.65个月,经济效益明显。该研究验证了以级间冷却优化为切入点的高效节能路径,对同类深冷空分装置的节能改造与精益运行具有重要的推广作用。 展开更多
关键词 深冷制氧 空分冷却器 节能改造 单耗优化
在线阅读 下载PDF
Cause Analysis and Countermeasures of Influence on Long-term Operation of Dry Air Cooling of 1.2 Million Tons/Year Catalytic Unit
18
作者 ZHONGYuan JIAYuyu 《外文科技期刊数据库(文摘版)工程技术》 2022年第2期182-187,共6页
During the operation of dry air cooler in fractionating and suction stabilization unit of 1.2 million tons/year catalytic cracking unit in Yongping Refinery, the tube bundle of heat-dissipating finned tubes was blocke... During the operation of dry air cooler in fractionating and suction stabilization unit of 1.2 million tons/year catalytic cracking unit in Yongping Refinery, the tube bundle of heat-dissipating finned tubes was blocked, post-cooling temperature was too high, tube bundle leaked, fan system vibrated and rattled, which seriously affected the long-term stable operation of catalytic cracking unit and the production capacity completed as planned, resulting in high processing task pressure and poor smooth operation of equipment. Based on the structure of dry air cooling equipment and long-term operation experience, this paper analyzes the causes of the problems found in the operation process and puts forward various countermeasures to ensure the long, full and optimal operation of dry air cooler in the fractionation and suction stabilization unit of the catalytic cracking unit. 展开更多
关键词 air cooler BLOCKAGE LEAKS decrease in thermal efficiency measures and countermeasures
原文传递
篦冷机轻量化专家控制系统的应用实践
19
作者 吴爱军 饶锐 +1 位作者 章利华 左涵斌 《水泥技术》 2026年第1期40-46,共7页
篦冷机作为新型干法水泥熟料生产线的核心设备,其运行状态直接影响水泥生产系统产量、能耗及产品质量。针对预热器系统升级后,篦冷机负荷超限引发的料层波动大、风机电流震荡、操作人员调整频繁、二三次风温不稳定等问题,基于热平衡理... 篦冷机作为新型干法水泥熟料生产线的核心设备,其运行状态直接影响水泥生产系统产量、能耗及产品质量。针对预热器系统升级后,篦冷机负荷超限引发的料层波动大、风机电流震荡、操作人员调整频繁、二三次风温不稳定等问题,基于热平衡理论与多变量控制技术,开发了篦冷机轻量化专家控制系统。该系统通过划分高、中、低温段风量控制区间,设定单位熟料用风量标准,结合神经网络建模与模型预测算法,实现了篦冷机篦速与风机风量的自适应协同调节。应用结果表明,系统投用后熟料产量提升181t/d,吨熟料标煤耗降低0.45kgce/t,余热锅炉发电量增加0.94kW·h/t,烧成电耗下降1.02kW·h/t,且二、三次风温波动幅度显著减小,设备运行稳定性与能源利用效率大幅提升,为水泥行业同类设备优化提供了技术参考。 展开更多
关键词 篦冷机 篦速 风机风量 轻量化 专家控制系统 自适应调节
在线阅读 下载PDF
Numerical Simulation and Experimental Studies of Air Treatment Process with Water Spray of One Row Counter Flow
20
作者 NI Bo(倪波) 《Journal of Donghua University(English Edition)》 EI CAS 2001年第3期14-19,共6页
The present work is focused on heat and mass transfer in a direct evaporative air cooler of one row counter flow spray. Models of the two-phase flow in such a air treatment system have been developed. The fields of te... The present work is focused on heat and mass transfer in a direct evaporative air cooler of one row counter flow spray. Models of the two-phase flow in such a air treatment system have been developed. The fields of temperature and relative humidity in spray chamber, as well as the trajectories of sprayed drops have been obtained by numerical method. Experiments aiming at quantifying the system performance and its influence factors have been conducted. It indicates that the increase of air velocity and water/air ratio while the decrease of nozzle density are favorable. The performance of the system of parallel flow spray and counter flow spray have been compared by means of humidifying efficiency. Comparison between numerical simulation and experimental results demonstrate good agreement for outlet air temperature with a maximum error of 8% observed for air relative humidity. 展开更多
关键词 heat and mass transfer EVAPORATIVE air cooler air washer ADIABATIC humidifying.
在线阅读 下载PDF