VFDs (variable frequency drives) are an integral part of many industrial plants and stations. Reliable operation and maintenance of these drives is vital to ensure sustained plant operation and availability. Underst...VFDs (variable frequency drives) are an integral part of many industrial plants and stations. Reliable operation and maintenance of these drives is vital to ensure sustained plant operation and availability. Understanding of the principles of operation of VFD systems as well as knowledge about their required operating environment is necessary for all operating personnel. Many times the operating personnel do not get involved with different technical issues until a complete failure has occurred. Hence, the awareness of the most dominant failure causes has a significant impact on assisting operators to avoid catastrophic failures and tremendous economic losses due to VFD shutdown. Proper plant design, accurate monitoring and data logging, following manufacturer preventive maintenance schedule, and choosing qualified team of operators can be the key to an efficient operation and a long lifetime for any VFD system. In this paper, we have analyzed the electrical and non-electrical causes of VFD failures based on a case study of a typical medium voltage VFD pumping station. Finally, recommendations are given from field analysis and observations.展开更多
The current match method of electric powertrain still makes use of longitudinal dynamics, which can’t realize maximum capacity for on-board energy storage unit and can’t reach lowest equivalent fuel consumption as w...The current match method of electric powertrain still makes use of longitudinal dynamics, which can’t realize maximum capacity for on-board energy storage unit and can’t reach lowest equivalent fuel consumption as well. Another match method focuses on improving available space considering reasonable layout of vehicle to enlarge rated energy capacity for on-board energy storage unit, which can keep the longitudinal dynamics performance almost unchanged but can’t reach lowest fuel consumption. Considering the characteristics of driving motor, method of electric powertrain matching utilizing conventional longitudinal dynamics for driving system and cut-and-try method for energy storage system is proposed for passenger cars converted from traditional ones. Through combining the utilization of vehicle space which contributes to the on-board energy amount, vehicle longitudinal performance requirements, vehicle equivalent fuel consumption level, passive safety requirements and maximum driving range requirement together, a comprehensive optimal match method of electric powertrain for battery-powered electric vehicle is raised. In simulation, the vehicle model and match method is built in Matlab/simulink, and the Environmental Protection Agency (EPA) Urban Dynamometer Driving Schedule (UDDS) is chosen as a test condition. The simulation results show that 2.62% of regenerative energy and 2% of energy storage efficiency are increased relative to the traditional method. The research conclusions provide theoretical and practical solutions for electric powertrain matching for modern battery-powered electric vehicles especially for those converted from traditional ones, and further enhance dynamics of electric vehicles.展开更多
Adjustable speed AC Motor drives have been used extensively in modern industry and transportation which calls for electrical and mechanical energy conversion with wide output power range applications.Because of its mo...Adjustable speed AC Motor drives have been used extensively in modern industry and transportation which calls for electrical and mechanical energy conversion with wide output power range applications.Because of its modularity and scalability,the drive system can be extended to many different application areas.More recently,adjustable speed AC motor drive applications are spreading not only in industry applications,but also sky and the marine.In this paper,after summarizing the history of adjustable speed AC motor drives and applications,the main issues of AC drive technologies are reviewed and investigated in the paper.Technical issues of adjustable speed AC motor drives including its standardization are surveyed and analyzed for more advancement.Finally,the paper provides the latest technical trends on adjustable speed AC motor drives technologies,and discusses the development of high speed high power PM motor.展开更多
Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the ...Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs.展开更多
文摘VFDs (variable frequency drives) are an integral part of many industrial plants and stations. Reliable operation and maintenance of these drives is vital to ensure sustained plant operation and availability. Understanding of the principles of operation of VFD systems as well as knowledge about their required operating environment is necessary for all operating personnel. Many times the operating personnel do not get involved with different technical issues until a complete failure has occurred. Hence, the awareness of the most dominant failure causes has a significant impact on assisting operators to avoid catastrophic failures and tremendous economic losses due to VFD shutdown. Proper plant design, accurate monitoring and data logging, following manufacturer preventive maintenance schedule, and choosing qualified team of operators can be the key to an efficient operation and a long lifetime for any VFD system. In this paper, we have analyzed the electrical and non-electrical causes of VFD failures based on a case study of a typical medium voltage VFD pumping station. Finally, recommendations are given from field analysis and observations.
基金supported by National Basic Research Program of China(973 Program, Grant No. 2011CB711200)National Natural Science Foundation of China (Grant No. 51105278)
文摘The current match method of electric powertrain still makes use of longitudinal dynamics, which can’t realize maximum capacity for on-board energy storage unit and can’t reach lowest equivalent fuel consumption as well. Another match method focuses on improving available space considering reasonable layout of vehicle to enlarge rated energy capacity for on-board energy storage unit, which can keep the longitudinal dynamics performance almost unchanged but can’t reach lowest fuel consumption. Considering the characteristics of driving motor, method of electric powertrain matching utilizing conventional longitudinal dynamics for driving system and cut-and-try method for energy storage system is proposed for passenger cars converted from traditional ones. Through combining the utilization of vehicle space which contributes to the on-board energy amount, vehicle longitudinal performance requirements, vehicle equivalent fuel consumption level, passive safety requirements and maximum driving range requirement together, a comprehensive optimal match method of electric powertrain for battery-powered electric vehicle is raised. In simulation, the vehicle model and match method is built in Matlab/simulink, and the Environmental Protection Agency (EPA) Urban Dynamometer Driving Schedule (UDDS) is chosen as a test condition. The simulation results show that 2.62% of regenerative energy and 2% of energy storage efficiency are increased relative to the traditional method. The research conclusions provide theoretical and practical solutions for electric powertrain matching for modern battery-powered electric vehicles especially for those converted from traditional ones, and further enhance dynamics of electric vehicles.
文摘Adjustable speed AC Motor drives have been used extensively in modern industry and transportation which calls for electrical and mechanical energy conversion with wide output power range applications.Because of its modularity and scalability,the drive system can be extended to many different application areas.More recently,adjustable speed AC motor drive applications are spreading not only in industry applications,but also sky and the marine.In this paper,after summarizing the history of adjustable speed AC motor drives and applications,the main issues of AC drive technologies are reviewed and investigated in the paper.Technical issues of adjustable speed AC motor drives including its standardization are surveyed and analyzed for more advancement.Finally,the paper provides the latest technical trends on adjustable speed AC motor drives technologies,and discusses the development of high speed high power PM motor.
基金This work was supported by the National Key R&D Program of China (Grant No. 2016YFF0203400). The program focuses on studies on service quality monitoring and maintenance quality control technology for large wind turbines. The project leader is Professor Shoudao Huang. The authors are also grateful to the National Natural Science Foundation of China (Grant No. 51377050) for the financial support.
文摘Electric power conversion system (EPCS), which consists of a generator and power converter, is one of the most important subsystems in a direct-drive wind turbine (DD-WT). However, this component accounts for the most failures (approximately 60% of the total number) in the entire DD-WT system according to statistical data. To improve the reliability of EPCSs and reduce the operation and maintenance cost of DD-WTs, numerous researchers have studied condition monitoring (CM) and fault diagnostics (FD). Numerous CM and FD techniques, which have respective advantages and disadvantages, have emerged. This paper provides an overview of the CM, FD, and operation control of EPCSs in DD-WTs under faults. After introducing the functional principle and structure of EPCS, this survey discusses the common failures in wind generators and power converters; briefly reviewed CM and FD methods and operation control of these generators and power converters under faults; and discussed the grid voltage faults related to EPCSs in DD-WTs. These theories and their related technical concepts are systematically discussed. Finally, predicted development trends are presented. The paper provides a valuable reference for developing service quality evaluation methods and fault operation control systems to achieve high-performance and high-intelligence DD-WTs.