AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular le...AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.展开更多
AIM:To evaluate the reliability of measurements of corneal changes with accommodation in healthy eyes using a Scheimpflug imaging-based system and how these measurements distribute in the normal population.METHODS:Pro...AIM:To evaluate the reliability of measurements of corneal changes with accommodation in healthy eyes using a Scheimpflug imaging-based system and how these measurements distribute in the normal population.METHODS:Prospective,non-randomized,comparative study including 27 healthy subjects(54 eyes),including emmetropia(13 eyes),myopia(17 eyes),hyperopia(4 eyes)and astigmatism(20 eyes)groups.In all cases,a complete eye examination was performed,including the analysis of corneal changes with different accommodative stimuli(+2.00,0.00 and-3.00 D)using the Pentacam AXL system.The investigation was structured in 2 phases:repeatability analysis and characterization of accommodation-related corneal changes in healthy populations.RESULTS:In the repeatability analysis,the index of height asymmetry(IHA)showed the greatest variability with the three accommodative stimuli,being the results for the rest of parameters acceptable.The group of emmetropes showed significant differences with accommodative changes in the position of maximum keratometry(Kmax;P<0.05),whereas in the astigmatism group,significant changes were not only observed in the position of Kmax,but also in minimum corneal thickness(MCT),corneal spherical aberration,and total and low order aberration root mean square(all P<0.05).Likewise,a significant difference was found in the displacement of the X position of Kmax with+2.00 D and-3.00 D in the myopia group(P=0.033)as well as in changes with+2.00 D and-3.00 D in the magnitude of the position vector of Kmax in the emmetropia group(P<0.05).No significant changes were found between accommodative stimuli in the displacement of coordinates of MCT(P≥0.109).CONCLUSION:The position of Kmax and MCT in healthy corneas can change significantly when presenting different accommodative stimuli using the accommodation mode of the Pentacam system,with different trends in these accommodation-related corneal changes between refractive errors.Likewise,the consistency of the measurements obtained with Scheimpflug has been confirmed.展开更多
AIM: To estimate and compare the frequency of accommodative insufficiency(AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within th...AIM: To estimate and compare the frequency of accommodative insufficiency(AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within the same population would help to minimize bias due to sampling or methodological variability. METHODS: Retrospective study of 205 medical records of symptomatic subjects free of any organic cause and symptoms persisting despite optical compensation evaluated. Based on the most commonly clinical diagnostics criteria found in the literature, four diagnostics criteria were established for AI(Ⅰ, Ⅱ, Ⅲ and Ⅳ) based on subjective accommodative tests: monocular accommodative amplitude two or more diopters below Hofstetter's minimum value [15-(0.25×age)](Ⅰ, Ⅱ, Ⅲ, Ⅳ); failing monocular accommodative facility with minus lens, establishing the cut-off in 0 cycles per minute(cpm)(Ⅰ) and in 6 cpm(Ⅱ, Ⅲ); failing binocular accommodative facility with minus lens, establishing the cut-off in 0 cpm(Ⅰ) and in 3 cpm(Ⅱ).RESULTS: The proportion of AI(95%CⅠ) for criteria Ⅰ, Ⅱ, Ⅲ and Ⅳ were 1.95%(0.04%-3.86%), 2.93%(0.31%-4.57%), 6.34%(1.90%-7.85%) and 41.95%(35.14%-48.76%) respectively, with a statistically significant difference shown between these values(χ2=226.7, P<0.001). A pairwise multiple comparison revealed that the proportion of AI detected for criterion Ⅳ was significantly greater than the proportion for the rest of the criteria(P-adjusted<0.05 in all cases).CONCLUSION: The prevalence of cases of AI within the same clinical population varies with the clinical diagnostic criteria selected. The variation is statistically significant when considering the monocular accommodative amplitude as the only clinical diagnostic sign.展开更多
Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients we...Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation.展开更多
AIM: To evaluate the effects of virtual reality(VR) training on different parameters of vision.METHODS: Sixty individuals ranged 18-60 years old with asthenopia were randomly divided into short-term(n=40) and long-ter...AIM: To evaluate the effects of virtual reality(VR) training on different parameters of vision.METHODS: Sixty individuals ranged 18-60 years old with asthenopia were randomly divided into short-term(n=40) and long-term(n=20) treatment groups. They were given a specially designed VR training device only once for 15 min or 3-4 times a day for 15 min each time for 1 mo. The visual acuity, spherical equivalent, accommodative range, accommodative facility, pupil size, and visual fatigue were evaluated before(control) and after VR training. RESULTS: The visual acuity, accommodative range, and accommodative facility increased in subjects of the shortterm treatment group, whereas their pupil size contracted significantly. No significant changes in spherical equivalent and visual fatigue were observed. The changes in distant vision and corrected visual acuity were positively correlated with those in pupil size, but not with spherical equivalent. The accommodative range and accommodative facility improved significantly in subjects of the long-term treatment group. No significant changes in visual acuity, spherical equivalent, pupil size, and visual fatigue were noted. CONCLUSION: VR training can improve the accommodative range and accommodative facility of human eyes. Although short-term VR training can transiently improve vision, which probably due to bright light adaptation, there is no evidence that it can improve myopia.展开更多
Accommodative response and its possible role in myopia development has been explored through the study of the microfluctuations(MFs) of accommodation, which are commonly divided in high(1.0 to 2.3 Hz) and low(0.1 to 0...Accommodative response and its possible role in myopia development has been explored through the study of the microfluctuations(MFs) of accommodation, which are commonly divided in high(1.0 to 2.3 Hz) and low(0.1 to 0.6 Hz) frequency components. Previous research efforts have evidenced that a certain percentage of the amplitude of MFs seems not to originate in the accommodative response. We aimed to develop and test a new approach to reduce this non-accommodative noise. For this purpose, ten healthy participants were enrolled to determine the difference between the amplitude of MFs at near and distance for each range of frequencies, which was defined as the relative amplitude of MFs. The findings support the exploration of the relative rather than absolute values of the amplitude of MFs to better understand the contribution of both accommodative and non-accommodative factors to MFs.展开更多
AIMTo evaluate the characteristics of pupillo-accommodative functions in patients with idiopathic tonic pupil according to the time of onset, gender, and age.
Background The TetraFlex accommodating intraocular lens (IOL) was designed to supply the patients both satisfied far and near vision after cataract surgery.So we need to evaluate the safety, distance and near visual...Background The TetraFlex accommodating intraocular lens (IOL) was designed to supply the patients both satisfied far and near vision after cataract surgery.So we need to evaluate the safety, distance and near visual acuity, subjective accommodation and IOL mobility with the TetraFlex accommodating IOL implantation.Methods Fifty eyes of 42 study-eligible cataract patients, who gave informed consent at a single eye clinic in China over a 10-month period, underwent phacoemulsification with TetraFlex IOL implantation.At three months postoperation,uncorrected visual acuities (UCVA), best corrected visual acuities (BCVA), distance-corrected near visual acuities (DCNVA), subjective accommodation using the defocus method, and pilocarpine-induced IOL mobility were measured.Results No postoperative complications were noted in the study.Three months postoperation UCVA and BCVA were 20/40 or bettter in 82% (41/50) and 92% (46/50) of eyes, respectively; 66% (33/50) of the eyes had DCNVA of Jager (J) 4or better at 3 months.In addition, the mean subjective accommodation was (0.94±0.61) diopters (D) (range from 0.50 to 1.50 D) and pilocarpine-induced IOL mobility was (337±124) μm (range from 121 to 501 μm) with the TetraFlex.High relationship (r2=0.901, P 〈0.01) was found between these two measurements.Conclusion Implantation of the TetraFlex is safe and leads to excellent uncorrected distance vision and good uncorrected near vision.展开更多
Background:To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function(PSF)Strehl ratio using a pyramidal wavefront sensor(PWS)-bas...Background:To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function(PSF)Strehl ratio using a pyramidal wavefront sensor(PWS)-based aberrometer.Methods:This study included 194 eyes implanted with:(a)19 AcrySof SA60AT(control group);(b)19 Miniwell;(c)24 LENTIS Mplus LS-313 MF30;(d)33 LENTIS Mplus LS-313 MF15;(e)17 AkkoLens Lumina;(f)31 AT LISA Tri 839MP;(g)20 Precizon Presbyopic;(h)20 AcrySof IQ PanOptix;(i)11 Tecnis Eyhance.Main outcome measures were PSF Strehl ratio,PSF Strehl ratio excluding second-order aberrations(PSFw2),total root mean square(RMS),low-order aberration(LOA)and high-order aberration(HOA)RMS measured by PWS aberrometer.Results:AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0-and 4.0-mm pupil size(0.52±0.14 and 0.31±0.10;P<0.05),followed by SA60AT(0.41±0.11 and 0.28±0.07)and PanOptix(0.4±0.07 and 0.26±0.04).AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.004).Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.002).Total RMS,LOA RMS,HOA RMS,PSF Strehl ratio and PSFw2 varied significantly between the studied groups(P<0.001).Conclusions:Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.AT LISA Tri,SA60AT and PanOptix showed the highest values of far distance retinal image quality,while the lowest PSFw2 Strehl ratios were displayed by Miniwell,Mplus MF30 and Precizon Presbyopic.展开更多
Presbyopia still remains the last frontier of refractive surgery.Its surgical management is under constant evolution due to the limitations that exist today with respect to its management,which is probably in relation...Presbyopia still remains the last frontier of refractive surgery.Its surgical management is under constant evolution due to the limitations that exist today with respect to its management,which is probably in relation with the multifactorial basis in which presbyopia is clinically developed in the human.Until currently,virtually all surgical techniques that have been proposed for its correction are based on the induction of pseudoaccommodation in the presbyopic eye,including multifocality.However,the real restoration of accommodation is more complex,and it has been tried by the use of different,so called,“accommodative”pseudophakic intraocular lenses(AIOL).Overall,the reported results with these lenses by independent authors have been modest in relation with the restoration of the accommodative power of the eye and these modest benefits are usually lost with time due to the long term changes in the capsular bag.This fact made these lenses to be almost abandoned in the last few years,but there are currently other AIOL models being used with innovative mechanisms of action and different anatomical support outside the capsular bag that offer encouraging preliminary results that could bring a new potential of application to these types of lenses.In this article,we will update the modern refractive surgeon about the fundamentals and provide updated information about the outcomes of AIOLs by reviewing the concept of accommodation,the different attempts that have been accomplished in the past,their demonstrated published results in human clinical trials,and the future alternatives that may arrive in the near future.展开更多
BackgroundTo study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-b...BackgroundTo study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer.MethodsThis study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group);(b) 19 Miniwell;(c) 24 LENTIS Mplus LS-313 MF30;(d) 33 LENTIS Mplus LS-313 MF15;(e) 17 AkkoLens Lumina;(f) 31 AT LISA Tri 839MP;(g) 20 Precizon Presbyopic;(h) 20 AcrySof IQ PanOptix;(i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer.ResultsAT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10;P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001).ConclusionsFar distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.展开更多
Psychoeducation is a structured but straightforward and effective treatment,which consists of educating patients and family members about psychiatric disorders,teaching them to cope with the illness,and supporting the...Psychoeducation is a structured but straightforward and effective treatment,which consists of educating patients and family members about psychiatric disorders,teaching them to cope with the illness,and supporting them during treatment.Psychoeducation as an independent treatment is effective in schizophrenia and bipolar disorder.Psychoeducation is a core component of cognitivebehavioural therapy(CBT)or exposure and response prevention(ERP)treatment,which are the standard psychotherapeutic treatments for obsessive-compulsive disorder(OCD).However,research on the benefits of psychoeducational treatments in OCD is limited compared to schizophrenia and bipolar disorders.Very few studies have examined psychoeducation as an independent treatment for OCD,and its efficacy is not proven.The effectiveness of CBT or ERP for OCD is well established,but the contribution of psychoeducation to the efficacy of these treatments is unclear.Recently,there has been a greater understanding of maladaptive family responses,such as accommodation and antagonism,that worsen the outcome and treatment response in OCD.Family-based psychoeducational treatments targeting inappropriate family responses are effective in reducing obsessional symptoms,attenuating the negative family impact of OCD,and improving patient and family functioning.Family-based psychoeducation is a promising treatment for OCD,but there are methodological issues with the evidence,and trials among adult patients are limited compared to children and adolescents.The other obstacles to the implementation of psychoeducational treatments of OCD are the large treatment gap,lack of research from low-and middle-income countries,and the limited attempts to develop culturally adapted treatments in these countries.Thus,further research should focus on optimising psychoeducational treatments for OCD and efficiently delivering these treatments in routine clinical settings.展开更多
ISO releases two standards for tourism ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Par...ISO releases two standards for tourism ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Part 1:Vocabulary,were released recently,the development of which were led by China.展开更多
AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students usin...AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students using simple random sampling.Objective refraction,ocular alignment,vergence and accommodative performance were measured and assessed in all participants.Data on QOL were collected using the College of Optometrists in Vision Development-Quality of Life(COVD-QOL)Questionnaire.The effect of mentioned parameters on the QOL were evaluated.RESULTS:Totally 726 students with mean age of 21.35±1.88y were evaluated in this study,51.5%of whom were female.Esophoria was caused significantly lower QOL in the domains of somatic symptoms and occupationalphysical symptoms(P<0.05);Besides,esotropia decreased QOL in domains of somatic symptoms P=0.002 and psychological factors(P=0.023).Students with accommodation insufficiency experienced more symptoms in all domains(P<0.05)except for psychological factors(P=0.07).Increasing in the near point of convergence and accommodation and decreases QOL and increasing accommodative facility increases QOL(all P<0.05).Myopia and astigmatism cause decrease in QOL(both P<0.05),but hyperopic students had better QOL in comparison with others(P<0.05).CONCLUSION:Screening programs and treatment of refractive errors and binocular vision anomalies,especially phoria and accommodative insufficiency,positively impact the QOL and academic achievements of university students.展开更多
The selection of twin variants plays a critical role in shaping the deformation texture and mechanical properties of magnesium alloys that are limited by slip systems and diverse twinning modes.In this study,we invest...The selection of twin variants plays a critical role in shaping the deformation texture and mechanical properties of magnesium alloys that are limited by slip systems and diverse twinning modes.In this study,we investigated the twin variant selection and the effect of twinning activity on the strain hardening of a hot-rolled AZ31 magnesium alloy by quasi-in-situ EBSD.Moreover,the Schmid factors and the displacement gradient tensors were computed to evaluate the activation of twin variants.The results reveal that the yield strength increased progressively after each deformation step,driven by grain subdivision and texture hardening induced by extension{1012}twinning and the Basinski effect at large strains.The nucleation and growth of the{1012}twins occurred either sequentially or simultaneously during the plastic deformation.At low plastic strains,the activation of most twin variants followed the high Schmid factor criterion while the other twin variants with lower Schmid factors were activated due to the interactions with preexisting twins characterized by high misorientation angles(around 60°).Additionally,this non-Schmid factor scenario was also attributed to low coordinated strain requirements from neighboring grains,showing the critical role of local deformation accommodation in the twinning process.These findings advance the fundamental understanding of the twin variant selection and its implications for the microstructure-property relationship in magnesium alloys for structural applications.展开更多
AIM:To explore choroidal thickness(CT)and choroidal vascularity index(CVI)changes around the macula and optic nerve head(ONH)using swept-source optical coherence tomography(SS-OCT)after small-incision lenticule extrac...AIM:To explore choroidal thickness(CT)and choroidal vascularity index(CVI)changes around the macula and optic nerve head(ONH)using swept-source optical coherence tomography(SS-OCT)after small-incision lenticule extraction(SMILE)and evaluate their associations with accommodation and aberrations.METHODS:Participants were divided into more myopic group(43 eyes)and less myopic group(33 eyes)according to refractive error.SS-OCT,negative relative accommodation(NRA),and positive relative accommodation(PRA)were analyzed before and 1d,1wk,and 1mo postoperatively.Root mean square higher-order aberrations(RMS HOAs),spherical aberrations(SAs),and coma were compared preoperative,1wk,and 1mo postoperatively.RESULTS:After surgery,RMS(0.29±0.26)and Coma(0.16±0.19)all increased.In the more myopic group,central and T macular CT(247.58±63.81 a n d 276.45±62.52μm)increased.NRA(0.41±0.51)and PRA(0.10±1.30)decreased,and SAs(0.21±0.21)increased.In the less myopic group,all regional and mean macular CT increased.NRA was correlated with mean and inferior CTs and mean ONH CVI.SE was correlated with macular CT,CVI,and ONH CT.Mean macular and ONH CTs were associated with RMS HOA,SA,and coma.Macular T2 CT was a significant predictor of SA.Macular T2 and N1 CT were correlated with coma.CONCLUSION:More variations in accommodation and aberrations and fewer choroid thickens on macular and ONH are found in more myopic eyes after SMILE.Choroidal values are associated with accommodation and aberrations during SMILE.Choroid parameters on SS-OCT varies in eyes with different refractive errors after SMILE and has an association with accommodation and visual quality.展开更多
Two international standards on tourism,ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Par...Two international standards on tourism,ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Part 1:Vocabulary,were recently released by ISO,the development of which was led by China.展开更多
Against the backdrop of active global responses to climate change and the accelerated green and low-carbon energy transition,the co-optimization and innovative mechanism design of multimodal energy systems have become...Against the backdrop of active global responses to climate change and the accelerated green and low-carbon energy transition,the co-optimization and innovative mechanism design of multimodal energy systems have become a significant instrument for propelling the energy revolution and ensuring energy security.Under increasingly stringent carbon emission constraints,how to achieve multi-dimensional improvements in energy utilization efficiency,renewable energy accommodation levels,and system economics-through the intelligent coupling of diverse energy carriers such as electricity,heat,natural gas,and hydrogen,and the effective application of market-based instruments like carbon trading and demand response-constitutes a critical scientific and engineering challenge demanding urgent solutions.展开更多
Understanding interactions between gas molecules and solid surface is key to the aerodynamic design of high-speed,high-altitude aerospace vehicles,but there is a large dispersion of gas-surface interaction parameters ...Understanding interactions between gas molecules and solid surface is key to the aerodynamic design of high-speed,high-altitude aerospace vehicles,but there is a large dispersion of gas-surface interaction parameters or namely accommodation coefficients.The uncertainty results partly from different considerations of the interaction between gas molecules in various experimental and numerical methods.In this study,effects of gas-gas molecules interaction are systematically discussed by comparing two different approaches of molecular dynamics simulation of high-speed argon molecules scattering on a graphite surface.The popularly-used“single scattering”approach repeats the scattering process of a single gas molecule without considering the gas-gas molecules interaction.The newly-developed“continual scattering”approach continually shoots gas molecules at the surface,considering collisions between gas molecules in addition to gas molecules’collisions with surface.Gas-surface interaction features in the two approaches are compared and discussed under various affecting factors including rarefaction degree,gas-surface interaction strength,surface temperature and incident velocity.It is shown that these two approaches usually produce different accommodation coefficients,and the corresponding mechanisms are explained.This study could help clarify some doubts about the selection of accommodation coefficients in engineering practice,and also provide an instruction on design of an appropriate molecular dynamics simulation approach.展开更多
In polycrystalline Mg-RE magnesium alloys,the lattice parameter,dislocation dynamics and critical resolved shear stress(CRSS)for various deformation modes are altered with the addition of RE atom,finally affecting def...In polycrystalline Mg-RE magnesium alloys,the lattice parameter,dislocation dynamics and critical resolved shear stress(CRSS)for various deformation modes are altered with the addition of RE atom,finally affecting deformation mode and strain accommodation mechanism among neighboring grains.Uniaxial compression tests were performed on as-extruded AZ81-La Mg alloy samples with the c-axis of the majority of crystals vertical to the compression direction.Twin variants and dominant slip systems were examined by electron backscattered diffraction(EBSD)technique.It is found by in-grain misoriention axis(IGMA)analysis that the plastic deformation is mainly accommodated by a combination of the pyramidal slip and the basal slip.The dominant twin variant is{0112}<0111>and{1102}<1101>.Here,we applied a modified displacement gradient accommodation(m-DGA)method to evaluate the selection mechanism of twin/slip in neighbour grain stimulated by{1012}extension twin.It is found that the activated slip system and/or twin variant in the neighbouring grain is determined by the accommodation of the major shear strain induced by{1012}extension twin in such a way that strain concentration along grain boundaries can be relaxed.展开更多
基金Supported by the National Natural Science Foundation of China(No.52073181,No.52273134).
文摘AIM:To investigate the biocompatibility and bacterial adhesion properties of light responsive materials(LRM)and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses(AIOLs).METHODS:Employing fundamental experimental research techniques,LRM with human lens epithelial cells(hLECs)and human retinal pigment epithelium cells(ARPE-19 cells)were co-cultured.Commercially available intraocular lenses(IOLs)were used as controls to perform cell counting kit-8(CCK-8),cell staining under varying light intensities,cell adhesion and bacterial adhesion experiments.RESULTS:LRM exhibited a stronger inhibitory effect on the proliferation of ARPE19 cells than commercially available IOLs when co-cultured with the undiluted extract for 96h(P<0.05).Under other culturing conditions,the effects on the proliferation of hLECs and ARPE-19 cells were not significantly different between the two materials.Under the influence of light irradiation at intensities of 200 and 300 mW/cm^(2),LRM demonstrated a markedly higher inhibitory effect on the survival of hLECs compared to commercially available IOLs(P<0.0001).They also showed a stronger suppressive effect on the survival rate of ARPE-19 cells,with significant differences observed at 200 mW/cm^(2)(P<0.001)and extremely significant differences at 300 mW/cm^(2)(P<0.0001).Additionally,compared to commercially available IOLs,LRM had a higher number of cells adhering to their surface(P<0.05),as well as a significantly greater number of adherent bacterium(P<0.0001).CONCLUSION:LRM,characterized by their excellent non-contact tunable deformability and low cytotoxicity to ocular tissues,show considerable potential for use in the fabrication of AIOLs.These materials demonstrate strong cell adhesion;however,during photothermal conversion processes involving shape deformation under various light intensities,the resultant temperature rise may harm surrounding cells.These factors suggest that while the material plays a positive role in reducing the incidence of posterior capsule opacification(PCO),it also poses potential risks for retinal damage.Additionally,the strong bacterial adhesion of these materials indicates an increased risk of endophthalmitis.
文摘AIM:To evaluate the reliability of measurements of corneal changes with accommodation in healthy eyes using a Scheimpflug imaging-based system and how these measurements distribute in the normal population.METHODS:Prospective,non-randomized,comparative study including 27 healthy subjects(54 eyes),including emmetropia(13 eyes),myopia(17 eyes),hyperopia(4 eyes)and astigmatism(20 eyes)groups.In all cases,a complete eye examination was performed,including the analysis of corneal changes with different accommodative stimuli(+2.00,0.00 and-3.00 D)using the Pentacam AXL system.The investigation was structured in 2 phases:repeatability analysis and characterization of accommodation-related corneal changes in healthy populations.RESULTS:In the repeatability analysis,the index of height asymmetry(IHA)showed the greatest variability with the three accommodative stimuli,being the results for the rest of parameters acceptable.The group of emmetropes showed significant differences with accommodative changes in the position of maximum keratometry(Kmax;P<0.05),whereas in the astigmatism group,significant changes were not only observed in the position of Kmax,but also in minimum corneal thickness(MCT),corneal spherical aberration,and total and low order aberration root mean square(all P<0.05).Likewise,a significant difference was found in the displacement of the X position of Kmax with+2.00 D and-3.00 D in the myopia group(P=0.033)as well as in changes with+2.00 D and-3.00 D in the magnitude of the position vector of Kmax in the emmetropia group(P<0.05).No significant changes were found between accommodative stimuli in the displacement of coordinates of MCT(P≥0.109).CONCLUSION:The position of Kmax and MCT in healthy corneas can change significantly when presenting different accommodative stimuli using the accommodation mode of the Pentacam system,with different trends in these accommodation-related corneal changes between refractive errors.Likewise,the consistency of the measurements obtained with Scheimpflug has been confirmed.
文摘AIM: To estimate and compare the frequency of accommodative insufficiency(AI) within the same clinical population sample depending on the type of clinical criteria used for diagnosis. Comparing the frequency within the same population would help to minimize bias due to sampling or methodological variability. METHODS: Retrospective study of 205 medical records of symptomatic subjects free of any organic cause and symptoms persisting despite optical compensation evaluated. Based on the most commonly clinical diagnostics criteria found in the literature, four diagnostics criteria were established for AI(Ⅰ, Ⅱ, Ⅲ and Ⅳ) based on subjective accommodative tests: monocular accommodative amplitude two or more diopters below Hofstetter's minimum value [15-(0.25×age)](Ⅰ, Ⅱ, Ⅲ, Ⅳ); failing monocular accommodative facility with minus lens, establishing the cut-off in 0 cycles per minute(cpm)(Ⅰ) and in 6 cpm(Ⅱ, Ⅲ); failing binocular accommodative facility with minus lens, establishing the cut-off in 0 cpm(Ⅰ) and in 3 cpm(Ⅱ).RESULTS: The proportion of AI(95%CⅠ) for criteria Ⅰ, Ⅱ, Ⅲ and Ⅳ were 1.95%(0.04%-3.86%), 2.93%(0.31%-4.57%), 6.34%(1.90%-7.85%) and 41.95%(35.14%-48.76%) respectively, with a statistically significant difference shown between these values(χ2=226.7, P<0.001). A pairwise multiple comparison revealed that the proportion of AI detected for criterion Ⅳ was significantly greater than the proportion for the rest of the criteria(P-adjusted<0.05 in all cases).CONCLUSION: The prevalence of cases of AI within the same clinical population varies with the clinical diagnostic criteria selected. The variation is statistically significant when considering the monocular accommodative amplitude as the only clinical diagnostic sign.
文摘Purpose: To assess the visual outcome after implantation of the new Hydrophylic IOL type 41 B/G accommodating intraocular lens (AIOL). Methods: The presented lens was implanted during cataract surgery. All patients were offered follow-ups, allowing two postoperative measurements to be performed at 3 months and between 2020 and 2021. The mean time between lens implantation and last follow-up was 5.3 years (min. 1 year, max. 10 years). Excluded were patients with age-related macular degeneration or amblyopia. Patients with a foreign lens implanted into the second eye were included in a separate control group. Corrected distance (CDVA) and uncorrected distance visual acuity (UDVA) at 5 m, and corrected near (CNVA) and uncorrected near visual acuity (UNVA) at 40 cm were assessed. Furthermore, the postoperative spherical equivalent (SE), the dependence on spectacles and the occurrence of optical phenomena were evaluated. Results: The final study cohort consists of 65 patients with 119 implanted AIOLs. Significantly better visual results were obtained in both postoperative follow-ups compared with the preoperative results. The mean values of the last follow-up for the UNVA, CNVA, UDVA, and CDVA were 0.107 ± 0.10;0.039 ± 0.08;0.097 ± 0.11;and 0.040 ± 0.09 logMAR, respectively. Visual outcomes remained on a high level for up to 10 years and showed significantly better results compared to the control group. Postoperative SE was significantly improved. Nearly 70% of patients were no longer dependent on glasses. Furthermore, the occurrence of disturbing optical phenomena was denied by all patients. Conclusion: The results of this AIOL are particularly promising, especially since gratifying visual results could still be measured 10 years after implantation.
基金Supported by the National Natural Science Foundation of China (No.81800868)the Health and Family Planning Commission of Zhejiang Province,China (No.2018KY057)the Natural Science Foundation of Zhejiang Province (No.LY19H120007)。
文摘AIM: To evaluate the effects of virtual reality(VR) training on different parameters of vision.METHODS: Sixty individuals ranged 18-60 years old with asthenopia were randomly divided into short-term(n=40) and long-term(n=20) treatment groups. They were given a specially designed VR training device only once for 15 min or 3-4 times a day for 15 min each time for 1 mo. The visual acuity, spherical equivalent, accommodative range, accommodative facility, pupil size, and visual fatigue were evaluated before(control) and after VR training. RESULTS: The visual acuity, accommodative range, and accommodative facility increased in subjects of the shortterm treatment group, whereas their pupil size contracted significantly. No significant changes in spherical equivalent and visual fatigue were observed. The changes in distant vision and corrected visual acuity were positively correlated with those in pupil size, but not with spherical equivalent. The accommodative range and accommodative facility improved significantly in subjects of the long-term treatment group. No significant changes in visual acuity, spherical equivalent, pupil size, and visual fatigue were noted. CONCLUSION: VR training can improve the accommodative range and accommodative facility of human eyes. Although short-term VR training can transiently improve vision, which probably due to bright light adaptation, there is no evidence that it can improve myopia.
文摘Accommodative response and its possible role in myopia development has been explored through the study of the microfluctuations(MFs) of accommodation, which are commonly divided in high(1.0 to 2.3 Hz) and low(0.1 to 0.6 Hz) frequency components. Previous research efforts have evidenced that a certain percentage of the amplitude of MFs seems not to originate in the accommodative response. We aimed to develop and test a new approach to reduce this non-accommodative noise. For this purpose, ten healthy participants were enrolled to determine the difference between the amplitude of MFs at near and distance for each range of frequencies, which was defined as the relative amplitude of MFs. The findings support the exploration of the relative rather than absolute values of the amplitude of MFs to better understand the contribution of both accommodative and non-accommodative factors to MFs.
文摘AIMTo evaluate the characteristics of pupillo-accommodative functions in patients with idiopathic tonic pupil according to the time of onset, gender, and age.
文摘Background The TetraFlex accommodating intraocular lens (IOL) was designed to supply the patients both satisfied far and near vision after cataract surgery.So we need to evaluate the safety, distance and near visual acuity, subjective accommodation and IOL mobility with the TetraFlex accommodating IOL implantation.Methods Fifty eyes of 42 study-eligible cataract patients, who gave informed consent at a single eye clinic in China over a 10-month period, underwent phacoemulsification with TetraFlex IOL implantation.At three months postoperation,uncorrected visual acuities (UCVA), best corrected visual acuities (BCVA), distance-corrected near visual acuities (DCNVA), subjective accommodation using the defocus method, and pilocarpine-induced IOL mobility were measured.Results No postoperative complications were noted in the study.Three months postoperation UCVA and BCVA were 20/40 or bettter in 82% (41/50) and 92% (46/50) of eyes, respectively; 66% (33/50) of the eyes had DCNVA of Jager (J) 4or better at 3 months.In addition, the mean subjective accommodation was (0.94±0.61) diopters (D) (range from 0.50 to 1.50 D) and pilocarpine-induced IOL mobility was (337±124) μm (range from 121 to 501 μm) with the TetraFlex.High relationship (r2=0.901, P 〈0.01) was found between these two measurements.Conclusion Implantation of the TetraFlex is safe and leads to excellent uncorrected distance vision and good uncorrected near vision.
基金financed in part by the Network for Cooperative Research in Health“OFTARED”—Reference:RD16/0008/0012Funded by Instituto de Salud Carlos IIIco-funded by European Regional Development Fund(ERDF),Project"A way to make Europe".
文摘Background:To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function(PSF)Strehl ratio using a pyramidal wavefront sensor(PWS)-based aberrometer.Methods:This study included 194 eyes implanted with:(a)19 AcrySof SA60AT(control group);(b)19 Miniwell;(c)24 LENTIS Mplus LS-313 MF30;(d)33 LENTIS Mplus LS-313 MF15;(e)17 AkkoLens Lumina;(f)31 AT LISA Tri 839MP;(g)20 Precizon Presbyopic;(h)20 AcrySof IQ PanOptix;(i)11 Tecnis Eyhance.Main outcome measures were PSF Strehl ratio,PSF Strehl ratio excluding second-order aberrations(PSFw2),total root mean square(RMS),low-order aberration(LOA)and high-order aberration(HOA)RMS measured by PWS aberrometer.Results:AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0-and 4.0-mm pupil size(0.52±0.14 and 0.31±0.10;P<0.05),followed by SA60AT(0.41±0.11 and 0.28±0.07)and PanOptix(0.4±0.07 and 0.26±0.04).AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.004).Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.002).Total RMS,LOA RMS,HOA RMS,PSF Strehl ratio and PSFw2 varied significantly between the studied groups(P<0.001).Conclusions:Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.AT LISA Tri,SA60AT and PanOptix showed the highest values of far distance retinal image quality,while the lowest PSFw2 Strehl ratios were displayed by Miniwell,Mplus MF30 and Precizon Presbyopic.
基金the funding of the framework of the Red Temática de Investigación Cooperativa en Salud(RETICS),reference number RD12/0034/0007financed by the Instituto Carlos III–General Subdirection of Networks and Cooperative Investigation Centers(R&D&I National Plan 2008–2011)the European Regional Development Fund(Fondo europeo de desarrollo regional FEDER).
文摘Presbyopia still remains the last frontier of refractive surgery.Its surgical management is under constant evolution due to the limitations that exist today with respect to its management,which is probably in relation with the multifactorial basis in which presbyopia is clinically developed in the human.Until currently,virtually all surgical techniques that have been proposed for its correction are based on the induction of pseudoaccommodation in the presbyopic eye,including multifocality.However,the real restoration of accommodation is more complex,and it has been tried by the use of different,so called,“accommodative”pseudophakic intraocular lenses(AIOL).Overall,the reported results with these lenses by independent authors have been modest in relation with the restoration of the accommodative power of the eye and these modest benefits are usually lost with time due to the long term changes in the capsular bag.This fact made these lenses to be almost abandoned in the last few years,but there are currently other AIOL models being used with innovative mechanisms of action and different anatomical support outside the capsular bag that offer encouraging preliminary results that could bring a new potential of application to these types of lenses.In this article,we will update the modern refractive surgeon about the fundamentals and provide updated information about the outcomes of AIOLs by reviewing the concept of accommodation,the different attempts that have been accomplished in the past,their demonstrated published results in human clinical trials,and the future alternatives that may arrive in the near future.
基金This study has been financed in part by the Network for Cooperative Research in Health“OFTARED”—Reference:RD16/0008/0012.Funded by Instituto de Salud Carlos III and co-funded by European Regional Development Fund(ERDF),Project“A way to make Europe”.
文摘BackgroundTo study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer.MethodsThis study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group);(b) 19 Miniwell;(c) 24 LENTIS Mplus LS-313 MF30;(d) 33 LENTIS Mplus LS-313 MF15;(e) 17 AkkoLens Lumina;(f) 31 AT LISA Tri 839MP;(g) 20 Precizon Presbyopic;(h) 20 AcrySof IQ PanOptix;(i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer.ResultsAT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10;P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001).ConclusionsFar distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.
文摘Psychoeducation is a structured but straightforward and effective treatment,which consists of educating patients and family members about psychiatric disorders,teaching them to cope with the illness,and supporting them during treatment.Psychoeducation as an independent treatment is effective in schizophrenia and bipolar disorder.Psychoeducation is a core component of cognitivebehavioural therapy(CBT)or exposure and response prevention(ERP)treatment,which are the standard psychotherapeutic treatments for obsessive-compulsive disorder(OCD).However,research on the benefits of psychoeducational treatments in OCD is limited compared to schizophrenia and bipolar disorders.Very few studies have examined psychoeducation as an independent treatment for OCD,and its efficacy is not proven.The effectiveness of CBT or ERP for OCD is well established,but the contribution of psychoeducation to the efficacy of these treatments is unclear.Recently,there has been a greater understanding of maladaptive family responses,such as accommodation and antagonism,that worsen the outcome and treatment response in OCD.Family-based psychoeducational treatments targeting inappropriate family responses are effective in reducing obsessional symptoms,attenuating the negative family impact of OCD,and improving patient and family functioning.Family-based psychoeducation is a promising treatment for OCD,but there are methodological issues with the evidence,and trials among adult patients are limited compared to children and adolescents.The other obstacles to the implementation of psychoeducational treatments of OCD are the large treatment gap,lack of research from low-and middle-income countries,and the limited attempts to develop culturally adapted treatments in these countries.Thus,further research should focus on optimising psychoeducational treatments for OCD and efficiently delivering these treatments in routine clinical settings.
文摘ISO releases two standards for tourism ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Part 1:Vocabulary,were released recently,the development of which were led by China.
文摘AIM:To evaluate the effects of refractive errors and binocular vision anomalies on the quality of life(QOL)of university students.METHODS:This cross-sectional analytical study was conducted on university students using simple random sampling.Objective refraction,ocular alignment,vergence and accommodative performance were measured and assessed in all participants.Data on QOL were collected using the College of Optometrists in Vision Development-Quality of Life(COVD-QOL)Questionnaire.The effect of mentioned parameters on the QOL were evaluated.RESULTS:Totally 726 students with mean age of 21.35±1.88y were evaluated in this study,51.5%of whom were female.Esophoria was caused significantly lower QOL in the domains of somatic symptoms and occupationalphysical symptoms(P<0.05);Besides,esotropia decreased QOL in domains of somatic symptoms P=0.002 and psychological factors(P=0.023).Students with accommodation insufficiency experienced more symptoms in all domains(P<0.05)except for psychological factors(P=0.07).Increasing in the near point of convergence and accommodation and decreases QOL and increasing accommodative facility increases QOL(all P<0.05).Myopia and astigmatism cause decrease in QOL(both P<0.05),but hyperopic students had better QOL in comparison with others(P<0.05).CONCLUSION:Screening programs and treatment of refractive errors and binocular vision anomalies,especially phoria and accommodative insufficiency,positively impact the QOL and academic achievements of university students.
文摘The selection of twin variants plays a critical role in shaping the deformation texture and mechanical properties of magnesium alloys that are limited by slip systems and diverse twinning modes.In this study,we investigated the twin variant selection and the effect of twinning activity on the strain hardening of a hot-rolled AZ31 magnesium alloy by quasi-in-situ EBSD.Moreover,the Schmid factors and the displacement gradient tensors were computed to evaluate the activation of twin variants.The results reveal that the yield strength increased progressively after each deformation step,driven by grain subdivision and texture hardening induced by extension{1012}twinning and the Basinski effect at large strains.The nucleation and growth of the{1012}twins occurred either sequentially or simultaneously during the plastic deformation.At low plastic strains,the activation of most twin variants followed the high Schmid factor criterion while the other twin variants with lower Schmid factors were activated due to the interactions with preexisting twins characterized by high misorientation angles(around 60°).Additionally,this non-Schmid factor scenario was also attributed to low coordinated strain requirements from neighboring grains,showing the critical role of local deformation accommodation in the twinning process.These findings advance the fundamental understanding of the twin variant selection and its implications for the microstructure-property relationship in magnesium alloys for structural applications.
基金Supported by the National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y20210194,No.Y20190638).
文摘AIM:To explore choroidal thickness(CT)and choroidal vascularity index(CVI)changes around the macula and optic nerve head(ONH)using swept-source optical coherence tomography(SS-OCT)after small-incision lenticule extraction(SMILE)and evaluate their associations with accommodation and aberrations.METHODS:Participants were divided into more myopic group(43 eyes)and less myopic group(33 eyes)according to refractive error.SS-OCT,negative relative accommodation(NRA),and positive relative accommodation(PRA)were analyzed before and 1d,1wk,and 1mo postoperatively.Root mean square higher-order aberrations(RMS HOAs),spherical aberrations(SAs),and coma were compared preoperative,1wk,and 1mo postoperatively.RESULTS:After surgery,RMS(0.29±0.26)and Coma(0.16±0.19)all increased.In the more myopic group,central and T macular CT(247.58±63.81 a n d 276.45±62.52μm)increased.NRA(0.41±0.51)and PRA(0.10±1.30)decreased,and SAs(0.21±0.21)increased.In the less myopic group,all regional and mean macular CT increased.NRA was correlated with mean and inferior CTs and mean ONH CVI.SE was correlated with macular CT,CVI,and ONH CT.Mean macular and ONH CTs were associated with RMS HOA,SA,and coma.Macular T2 CT was a significant predictor of SA.Macular T2 and N1 CT were correlated with coma.CONCLUSION:More variations in accommodation and aberrations and fewer choroid thickens on macular and ONH are found in more myopic eyes after SMILE.Choroidal values are associated with accommodation and aberrations during SMILE.Choroid parameters on SS-OCT varies in eyes with different refractive errors after SMILE and has an association with accommodation and visual quality.
文摘Two international standards on tourism,ISO 9468:2025,Tourism and related services-Online travel agency(OTA)-Guidelines for online accommodation booking platform services,and ISO 25639-1:2025,Exhibitions and events-Part 1:Vocabulary,were recently released by ISO,the development of which was led by China.
文摘Against the backdrop of active global responses to climate change and the accelerated green and low-carbon energy transition,the co-optimization and innovative mechanism design of multimodal energy systems have become a significant instrument for propelling the energy revolution and ensuring energy security.Under increasingly stringent carbon emission constraints,how to achieve multi-dimensional improvements in energy utilization efficiency,renewable energy accommodation levels,and system economics-through the intelligent coupling of diverse energy carriers such as electricity,heat,natural gas,and hydrogen,and the effective application of market-based instruments like carbon trading and demand response-constitutes a critical scientific and engineering challenge demanding urgent solutions.
基金This work was supported by the National Natural Science Foundation of China(No.12072343).
文摘Understanding interactions between gas molecules and solid surface is key to the aerodynamic design of high-speed,high-altitude aerospace vehicles,but there is a large dispersion of gas-surface interaction parameters or namely accommodation coefficients.The uncertainty results partly from different considerations of the interaction between gas molecules in various experimental and numerical methods.In this study,effects of gas-gas molecules interaction are systematically discussed by comparing two different approaches of molecular dynamics simulation of high-speed argon molecules scattering on a graphite surface.The popularly-used“single scattering”approach repeats the scattering process of a single gas molecule without considering the gas-gas molecules interaction.The newly-developed“continual scattering”approach continually shoots gas molecules at the surface,considering collisions between gas molecules in addition to gas molecules’collisions with surface.Gas-surface interaction features in the two approaches are compared and discussed under various affecting factors including rarefaction degree,gas-surface interaction strength,surface temperature and incident velocity.It is shown that these two approaches usually produce different accommodation coefficients,and the corresponding mechanisms are explained.This study could help clarify some doubts about the selection of accommodation coefficients in engineering practice,and also provide an instruction on design of an appropriate molecular dynamics simulation approach.
基金Project supported by the National Natural Science Foundation of China(52071139,52075167,U21A20130,U20A20275)the Natural Science Foundation of Hunan(2023JJ30262,2023JJ30252)Natural Science Foundation of Chongqing(CSTB2023NSCQ-MSX0886)。
文摘In polycrystalline Mg-RE magnesium alloys,the lattice parameter,dislocation dynamics and critical resolved shear stress(CRSS)for various deformation modes are altered with the addition of RE atom,finally affecting deformation mode and strain accommodation mechanism among neighboring grains.Uniaxial compression tests were performed on as-extruded AZ81-La Mg alloy samples with the c-axis of the majority of crystals vertical to the compression direction.Twin variants and dominant slip systems were examined by electron backscattered diffraction(EBSD)technique.It is found by in-grain misoriention axis(IGMA)analysis that the plastic deformation is mainly accommodated by a combination of the pyramidal slip and the basal slip.The dominant twin variant is{0112}<0111>and{1102}<1101>.Here,we applied a modified displacement gradient accommodation(m-DGA)method to evaluate the selection mechanism of twin/slip in neighbour grain stimulated by{1012}extension twin.It is found that the activated slip system and/or twin variant in the neighbouring grain is determined by the accommodation of the major shear strain induced by{1012}extension twin in such a way that strain concentration along grain boundaries can be relaxed.