期刊文献+
共找到8,438篇文章
< 1 2 250 >
每页显示 20 50 100
Coordinated Control Strategy of New Energy Power Generation System with Hybrid Energy Storage Unit 被引量:1
1
作者 Yun Zhang Zifen Han +2 位作者 Biao Tian Ning Chen Yi Fan 《Energy Engineering》 EI 2025年第1期167-184,共18页
The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,... The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units. 展开更多
关键词 Photovoltaic power suppression hybrid energy storage unit variationalmodal decomposition fuzzy control power distribution control
在线阅读 下载PDF
Strength-constrained unit commitment in IBR dominant power systems
2
作者 Yong-Kyu Kim Sang-Ho Lee Gyu-Sub Lee 《iEnergy》 2025年第2期121-131,共11页
In this paper,a strength-constrained unit commitment(UC)model incorporating system strength constraints based on the weighted short-circuit ratio(WSCR)is proposed.This model facilitates the comprehensive assessment of... In this paper,a strength-constrained unit commitment(UC)model incorporating system strength constraints based on the weighted short-circuit ratio(WSCR)is proposed.This model facilitates the comprehensive assessment of area-wide system strength in power systems with high inverter-based resource(IBR)penetration,thereby contributing to the mitigation of weak grid issues.Unlike traditional models,this approach considers the interactions among multiple IBRs.The UC problem is initially formulated as a mixed-integer nonlinear programming(MINLP)model,reflecting WSCR and bus impedance matrix modification constraints.To enhance computational tractability,the model is transformed into a mixed-integer linear programming(MILP)form.The effectiveness of the proposed approach is validated through simulations on the IEEE 5-bus,IEEE 39-bus,and a modified Korean power system,demonstrating the ability of the proposed UC model enhancing system strength compared to the conventional methodologies. 展开更多
关键词 unit commitment system strength inverter-based resource power system stability mixed-integer programming
在线阅读 下载PDF
Improving EGT sensing data anomaly detection of aircraft auxiliary power unit 被引量:8
3
作者 Liansheng LIU Yu PENG +3 位作者 Lulu WANG Yu DONG Datong LIU Qing GUO 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2020年第2期448-455,共8页
The reliability of the on-wing aircraft Auxiliary Power Unit(APU)decides the cost and the comfort of flight to a large degree.The most important function of APU is to help start main engines by providing compressed ai... The reliability of the on-wing aircraft Auxiliary Power Unit(APU)decides the cost and the comfort of flight to a large degree.The most important function of APU is to help start main engines by providing compressed air.Especially on the condition of sudden shutdown in the air,APU can offer additional thrust for landing.Therefore,its condition monitoring has drawn much attention from the academic and industrial field.Among the on-wing sensing data which can reflect its condition,Exhaust Gas Temperature(EGT)is one of the most important parameters.To ensure the reliability of EGT,one kind of data-driven anomaly detection framework for EGT sensing data is proposed based on the Gaussian Process Regression and Kernel Principal Component Analysis.The situations of one-dimensional and two-dimensional input data for EGT anomaly detection are considered,respectively.The cross-validation experiments are carried out by utilizing the real condition data of APU,which are provided by China Southern Airlines Company Limited Shenyang Maintenance Base.The anomalous stuck condition of EGT sensing data is also detected.Experimental results show that the proposed EGT sensing data anomaly detection method can achieve better performance of false positive ratio,false negative ratio and accuracy. 展开更多
关键词 ANOMALY detection AUXILIARY power unit Condition-based maintenance DATA-DRIVEN framework EXHAUST gas temperature
原文传递
Multi-model Predictive Control of Ultra-supercritical Coal-fired Power Unit 被引量:6
4
作者 王国良 阎威武 +2 位作者 陈世和 张曦 邵惠鹤 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2014年第7期782-787,共6页
The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi... The control of ultra-supercritical(USC) power unit is a difficult issue for its characteristic of the nonlinearity, large dead time and coupling of the unit. In this paper, model predictive control(MPC) based on multi-model and double layered optimization is introduced for coordinated control of USC unit. The linear programming(LP) combined with quadratic programming(QP) is used in steady optimization for computation of the ideal value of dynamic optimization. Three inputs(i.e. valve opening, coal flow and feedwater flow) are employed to control three outputs(i.e. load, main steam temperature and main steam pressure). The step response models for the dynamic matrix control(DMC) are constructed using the three inputs and the three outputs. Piecewise models are built at selected operation points. Double-layered multi-model predictive controller is implemented in simulation with satisfactory performance. 展开更多
关键词 Ultra-supercritical power unit Coordinated control Multi-model constrained predictive control
在线阅读 下载PDF
Power management unit chip design for automobile active-matrix organic light-emitting diode display module 被引量:4
5
作者 KIM J H PARK J H +7 位作者 KIM J H CAO T V LEE T Y BAN H J YANG K KIM H G HA P B KIM Y H 《Journal of Central South University》 SCIE EI CAS 2009年第4期621-628,共8页
A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump... A power management unit (PMU) chip supplying dual panel supply voltage, which has a low electro-magnetic interference (EMI) characteristic and is favorable for miniaturization, is designed. A two-phase charge pump circuit using external pumping capacitor increases its pumping current and works out the charge-loss problem by using bulk-potential biasing circuit. A low-power start-up circuit is also proposed to reduce the power consumption of the band-gap reference voltage generator. And the ring oscillator used in the ELVSS power circuit is designed with logic devices by supplying the logic power supply to reduce the layout area. The PMU chip is designed with MagnaChip's 0.25 μ high-voltage process. The driving currents of ELVDD and ELVSS are more than 50 mA when a SPICE simulation is done. 展开更多
关键词 DC-DC converter AMOLED charge pumping power management unit (PMU) dual panel supply voltage
在线阅读 下载PDF
Unit Commitment under the Environment of Wind Power and Large-Scale Bilateral Transactions 被引量:1
6
作者 Fang Liu Yi Pan +2 位作者 Junfeng Yang Zhiqiang Luo Lihua Liu 《Energy and Power Engineering》 2017年第4期611-624,共14页
Bilateral electric power contract is settled based on contract output curve. This paper considered the bilateral transactions execution, new energy accommodation, power grid security and generation economy, considerin... Bilateral electric power contract is settled based on contract output curve. This paper considered the bilateral transactions execution, new energy accommodation, power grid security and generation economy, considering the executive priority of different power components to establish a multi-objective coordination unit commitment model. Through an example to verify the effectiveness of the model in promoting wind power consumption, guaranteeing trade execution, and improving power generation efficiency, and analyzed the interactions to each other among the factors of wind power, trading and blocking. According to the results, when wind power causes reverse power flow in the congestion line, it will promote the implementation of contracts, the influence of wind power accommodation to trade execution should be analyzed combined with the grid block, the results can provide reference for wind power planning. 展开更多
关键词 Bilateral Electric power CONTRACT unit COMMITMENT Wind power ACCOMMODATION TRANSACTION Execution CONGESTION
在线阅读 下载PDF
LVP Modeling and Dynamic Characteristics Prediction of A Hydraulic Power Unit in Deep-Sea 被引量:1
7
作者 曹学鹏 叶敏 +2 位作者 邓斌 张翠红 俞祖英 《China Ocean Engineering》 SCIE EI CSCD 2013年第1期17-32,共16页
A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment. It is critical to predict its dynamic performances in deep-water before being immerged in the seawater, while the experimental tes... A hydraulic power unit (HPU) is the driving "heart" of deep-sea working equipment. It is critical to predict its dynamic performances in deep-water before being immerged in the seawater, while the experimental tests by simulating deep-sea environment have many disadvantages, such as expensive cost, long test cycles, and difficult to achieve low-temperature simulation, which is only used as a supplementary means for confirmatory experiment. This paper proposes a novel theoretical approach based on the linear varying parameters (LVP) modeling to foresee the dynamic performances of the driving unit. Firstly, based on the varying environment features, dynamic expressions of the compressibility and viscosity of hydranlic oil are derived to reveal the fluid performances changing. Secondly, models of hydraulic system and electrical system are accomplished respectively through studying the control process and energy transfer, and then LVP models of the pressure and flow rate control is obtained through the electro-hydraulic models integration. Thirdly, dynamic characteristics of HPU are obtained by the model simulating within bounded closed sets of varying parameters. Finally, the developed HPU is tested in a deep-sea imitating hull, and the experimental results are well consistent with the theoretical analysis outcomes, which clearly declare that the LVP modeling is a rational way to foresee dynamic performances of HPU. The research approach and model analysis results can be applied to the predictions of working properties and product designs for other deep-sea hydraulic pump. 展开更多
关键词 hydraulic power unit (HPLO linear varying parameters (L VP) modeling dynamic viscosity characteristics prediction
在线阅读 下载PDF
Distributed power conditioning unit of large-scale space solar power station 被引量:1
8
作者 Xintong LI Jianwei MI +2 位作者 Yiqun ZHANG Guanheng FAN Jie DU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2024年第8期421-434,共14页
In this paper,a multi-bus distributed Power Conditioning Unit(PCU)is proposed for the Space Solar Power Station with large scale photovoltaic(PV)array and power levels reaching MW level.In this unit,there are multiple... In this paper,a multi-bus distributed Power Conditioning Unit(PCU)is proposed for the Space Solar Power Station with large scale photovoltaic(PV)array and power levels reaching MW level.In this unit,there are multiple independent PV arrays.In each PV array,there are multiple independent PV subarrays.In this paper,a V-P droop control method with adaptive droop coefficient is proposed,which modifies the droop intercept based on the bus voltage deviation and the power per unit value of the PV array.This method ensures the accuracy of bus voltage and achieves proportional distribution of power between PV arrays based on the proposed topology structure in this paper.When the load changes or the output power of the PV array fluctuates,this method can ensure that power is distributed proportionally.The principle and control method of the proposed droop control method is analyzed in this paper.The effectiveness of the method is verified through MATLAB/Simulink simulation and experiment.Simulation and experimental results show that the proposed method can achieve power distributed proportionally when load changes and PV output power fluctuates,reduce bus voltage error caused by line impedance and differences in rated power of different PV arrays,and improve the performance of PV power generation system applied to space. 展开更多
关键词 Space Solar power Station Photovoltaics Droop control DC confluence power conditioning unit
原文传递
Optimization of Minimum Power Output for Combined Heat and Power Units Considering Peak Load Regulation Ability 被引量:1
9
作者 Cong Liu Deyue Men +4 位作者 Dan Xu Qiang Ding Guodong Huang Sai Dai Jingyang Zhou 《Energy and Power Engineering》 2017年第4期452-463,共12页
Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structu... Northern China has rich wind power and photovoltaic renewable resources. Combined Heat and Power (CHP) Units to meet the load demand and limit its peaking capacity in winter, to a certain extent, it results in structural problems of wind-solar power and thermoelectric. To solve these problems, this paper proposes a plurality of units together to ensure supply of heat load on the premise, by building a thermoelectric power peaking considering thermal load unit group dynamic scheduling model, to achieve the potential of different thermoelectric properties peaking units of the excavation. Simulation examples show, if the unit group exists obvious relationship thermoelectric individual differences, the thermal load dynamic scheduling can be more significantly improved overall performance peaking unit group, effectively increase clean energy consumptive. 展开更多
关键词 CHP unitS PEAK LOAD Regulation Thermal LOAD Distribution Solar Wind power CONSUMPTION Dynamic Scheduling
暂未订购
Three-Level Optimal Scheduling and Power Allocation Strategy for Power System Containing Wind-Storage Combined Unit 被引量:1
10
作者 Jingjing Bai Yunpeng Cheng +2 位作者 Shenyun Yao Fan Wu Cheng Chen 《Energy Engineering》 EI 2024年第11期3381-3400,共20页
To mitigate the impact of wind power volatility on power system scheduling,this paper adopts the wind-storage combined unit to improve the dispatchability of wind energy.And a three-level optimal scheduling and power ... To mitigate the impact of wind power volatility on power system scheduling,this paper adopts the wind-storage combined unit to improve the dispatchability of wind energy.And a three-level optimal scheduling and power allocation strategy is proposed for the system containing the wind-storage combined unit.The strategy takes smoothing power output as themain objectives.The first level is the wind-storage joint scheduling,and the second and third levels carry out the unit combination optimization of thermal power and the power allocation of wind power cluster(WPC),respectively,according to the scheduling power of WPC and ESS obtained from the first level.This can ensure the stability,economy and environmental friendliness of the whole power system.Based on the roles of peak shaving-valley filling and fluctuation smoothing of the energy storage system(ESS),this paper decides the charging and discharging intervals of ESS,so that the energy storage and wind power output can be further coordinated.Considering the prediction error and the output uncertainty of wind power,the planned scheduling output of wind farms(WFs)is first optimized on a long timescale,and then the rolling correction optimization of the scheduling output of WFs is carried out on a short timescale.Finally,the effectiveness of the proposed optimal scheduling and power allocation strategy is verified through case analysis. 展开更多
关键词 Wind power cluster energy storage system wind-storage combined unit optimal scheduling power allocation
在线阅读 下载PDF
ELECTRONIC CONTROL OF TURBINE POWER UNITS
11
作者 Wang Daobo(Department of Science and Technology,NUAA 29 Yudao Street,Nanjing 210016,P.R.China) 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1994年第2期177-182,共6页
This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employ... This paper is concerned with the development of electronic controller for turbine POwer units. In order to increase the reliability of the POwer unit, three control loops working in the hi-backup mode have been employed. This control strategy is able to satisfy the demands of the application of the power unit to the aviation fields. 展开更多
关键词 ELECTRONIC CONTROL power unitS AUXILIARY power supply TURBINE power unitS
在线阅读 下载PDF
Application of Solid Oxide Fuel Cell-Auxiliary Power Unit on Different Trucks in Northeast China
12
作者 周苏 王士嘉 《Journal of Donghua University(English Edition)》 EI CAS 2015年第4期565-570,共6页
A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance o... A diesel engine of conventional trucks has a low efficiency under the idling condition,leading to a high cost for heating or cooling in the cab during night. The solution to this problem will have great significance on energy conservation and emission reduction. A new auxiliary power unit of solid oxide fuel cell( SOFCAPU) with high efficiency solves this problem perfectly. Heat pump air conditioner is considered as a promising device for the application of SOFC-APU with a high cooling and heating efficiency. To make a quantitative analysis for the application of SOFC-APU,a model is built in Matlab / Simulink. The diesel engine model and SOFC-APU model are fitted based on some experimental data of SOFC-APU and diesel engine during the idling operation. An analysis of the application of SOFC-APU on different trucks in Northeast China is comprehensively made,including efficiency and emission. 展开更多
关键词 diesel engine TRUCK heating and cooling power emissions AUXILIARY power unit of solid oxide fuel cell(SOFC-APU)
在线阅读 下载PDF
Research on Optimization for Units Start During Power System Restoration
13
作者 Jun Chen Wei-xing Zhao +4 位作者 Hua-ying Su Jia-lin Bai Nian Liu Xiao-yan Qiu Qian Liao 《Energy and Power Engineering》 2013年第4期708-712,共5页
Considering units starting and network constraints and the concept of optimization period,a optimization model which is a typical multi-constraint knapsack problem is established to solve the selection optimization pr... Considering units starting and network constraints and the concept of optimization period,a optimization model which is a typical multi-constraint knapsack problem is established to solve the selection optimization problem of units starting in power system restoration period in this paper, and the objective of the model is to maximize the total power generation capability. A relative effectiveness assessment based on a improving data envelopment analysis is adopted to select the initial units to be started, genetic algorithms are employed to solve the knapsack problem to determine the most reasonable units be started at the current time. Finally, IEEE-39 bus system simulation result proves that the proposed model is feasible and effective. 展开更多
关键词 power system unitS START DATA envelopment analysis KNAPSACK PROBLEM
暂未订购
Control of Unit Power Factor PWM Rectifier
14
作者 Meifang Xue Mingzhi He 《Energy and Power Engineering》 2013年第4期121-124,共4页
To solve the problem of harmonic pollution to the power grid that caused by traditional diode rectifier and phase controlled rectifier, the unit power factor PWM rectifier is designed. The topology structure of the re... To solve the problem of harmonic pollution to the power grid that caused by traditional diode rectifier and phase controlled rectifier, the unit power factor PWM rectifier is designed. The topology structure of the rectifier circuit is introduced and the double closed-loop control strategy in three-phase stationary coordinate system is analyzed. For the deficiency of control strategy, the control strategy in two-phase synchronous rotating coordinate system is proposed. This makes the independent control of active current and reactive current to be realized. The simulation model of the PWM rectifier is built and the effectiveness of the control method proposed in this paper is verified by simulation. 展开更多
关键词 CONTROL PWM RECTIFIER unit power FACTOR d q COORDINATES
在线阅读 下载PDF
Unit stream power,minimum energy dissipation rate,and river engineering
15
作者 Chih Ted Yang 《水道港口》 2010年第5期317-317,共1页
Unit stream power is the most important and dominant parameter for the determination of transport rate of sand,gravel,and hyper-concentrated sediment with wash load.Minimum energy dissipation rate theory,or its simpli... Unit stream power is the most important and dominant parameter for the determination of transport rate of sand,gravel,and hyper-concentrated sediment with wash load.Minimum energy dissipation rate theory,or its simplified minimum unit stream power and minimum stream power theories,can provide engineers the needed theoretical basis for river morphology and river engineering studies.The Generalized Sediment Transport model for Alluvial River Simulation computer mode series have been developed based on the above theories.The computer model series have been successfully applied in many countries.Examples will be used to illustrate the applications of the computer models to solving a wide range of river morphology and river engineering problems. 展开更多
关键词 computer model minimum energy dissipation rate river engineering river morphology sediment transport unit stream power
在线阅读 下载PDF
Extended Sequential Truncation Technique for Adaptive Dynamic Programming Based Security-Constrained Unit Commitment with Optimal Power Flow Constraints
16
作者 Danli Long Hua Wei 《Journal of Power and Energy Engineering》 2014年第4期687-693,共7页
Considering the economics and securities for the operation of a power system, this paper presents a new adaptive dynamic programming approach for security-constrained unit commitment (SCUC) problems. In response to t... Considering the economics and securities for the operation of a power system, this paper presents a new adaptive dynamic programming approach for security-constrained unit commitment (SCUC) problems. In response to the “curse of dimension” problem of dynamic programming, the approach solves the Bellman’s equation of SCUC approximately by solving a sequence of simplified single stage optimization problems. An extended sequential truncation technique is proposed to explore the state space of the approach, which is superior to traditional sequential truncation in daily cost for unit commitment. Different test cases from 30 to 300 buses over a 24 h horizon are analyzed. Extensive numerical comparisons show that the proposed approach is capable of obtaining the optimal unit commitment schedules without any network and bus voltage violations, and minimizing the operation cost as well. 展开更多
关键词 power System Operation and Planning PRIORITY Order Adaptive Dynamic PROGRAMMING unit COMMITMENT
在线阅读 下载PDF
Counter-Rotating Type Horizontal-Axis Bidirectional Propellers for Tidal Stream Power Unit
17
作者 Yuki Funami Yuji Nakanishi +2 位作者 Nak-Joong Lee Bin Huang Toshiaki Kanemoto 《Journal of Power and Energy Engineering》 2017年第7期34-44,共11页
Tidal stream power units with horizontal-axis propellers are one of promising technologies for generating the renewable green energy. The ebb and flow require that the power unit must operate in bidirectional tidal st... Tidal stream power units with horizontal-axis propellers are one of promising technologies for generating the renewable green energy. The ebb and flow require that the power unit must operate in bidirectional tidal streams. Hence a tidal stream power unit with counter-rotating type horizontal-axis bidirectional propellers is proposed in this paper. The blades with fully-symmetrical hydrofoils were optimized numerically. The output and flow conditions predicted by the computational fluid dynamics simulations are compared with the results of the wind tunnel experiments at the higher tip speed ratios, which are of expected usual operating conditions of this unit. The numerical and experimental results show good agreements. It is also confirmed that the flow discharged from the counter-rotating type propellers has no swirling component, though the single propeller generates the unacceptable swirling component. 展开更多
关键词 BIDIRECTIONAL PROPELLERS COUNTER-ROTATING TYPE Machine TIDAL STREAM power unit Computational Fluid Dynamics
在线阅读 下载PDF
Research on the Prediction of Load Regulation Capacity for Supercritical Thermal Power Unit
18
作者 Yong He Zhuo Huang +3 位作者 Yaohua Tang Weimin Guo Yuanli Cai Haonan Jiang 《Journal of Power and Energy Engineering》 2020年第8期23-36,共14页
Both the modeling and the load regulation capacity prediction of a supercritical power plant are investigated in this paper. Firstly, an indirect identification method based on subspace identification method is propos... Both the modeling and the load regulation capacity prediction of a supercritical power plant are investigated in this paper. Firstly, an indirect identification method based on subspace identification method is proposed. The obtained identification model is verified by the actual operation data and the dynamic characteristics of the system are well reproduced. Secondly, the model is used to predict the load regulation capacity of thermal power unit. The power, main steam pressure, main steam temperature and other parameters are simulated respectively when the unit load is going up and down. Under the actual constraints, the load regulation capacity of thermal power unit can be predicted quickly. 展开更多
关键词 Supercritical Thermal power unit Subspace Identification Indirect Identification Load Regulation
在线阅读 下载PDF
Maximal loads acting on legs of powered roof support unit in longwalls with bumping hazards
19
作者 Stanislaw Szweda(Silesian Technical University Faculty of Mining and Geology Mining Mechanization Institute Gliwice, Poland) 《Journal of Coal Science & Engineering(China)》 2001年第2期1-15,共15页
In the article the results of measurements of the resultant force in the legs of a powered roof support unit, caused by a dynamic interaction of the rock mass, are discussed. The measurements have been taken in the lo... In the article the results of measurements of the resultant force in the legs of a powered roof support unit, caused by a dynamic interaction of the rock mass, are discussed. The measurements have been taken in the longwalls mined with a roof fall, characterized by the highest degree of bumping hazard. It has been stated that the maximal force in the legs F m, recorded during a dynamic interaction of the rock mass, is proportional to the initial static force in the legs F st,p . Therefore a need for a careful selection of the initial load of the powered roof support, according to the local mining and geological conditions, results from such a statement. Setting the legs with the supporting load exceeding the indispensable value for keeping the direct roof solids in balance, deteriorating the operational parameters of a longwall system also has a disadvantageous influence on the value of the force in the legs and the rate of its increase, caused by a dynamic interaction of the rock mass. A correct selection of the initial load causes a decrease in the intensity of a dynamic interaction of the rock mass on powered roof supports, which also has an advantageous influence on their life. Simultaneously with the measurements of the resultant force in the legs, the vertical acceleration of the canopy was also recorded. It has enabled to prove that the external dynamic forces may act on the unit both from the roof as well as from the floor. The changes of the force in the legs caused by dynamic phenomena intrinsically created in the roof and changes of the force in the legs caused by blasting explosives in the roof of the working, have been analyzed separately. It has been stated that an increase in the loads of legs, caused by intrinsic phenomena is significantly higher than a force increase in the legs caused by blasting. It means that powered roof supports, to be operated in the workings, where the bumping hazard occurs, will also transmit the loads acting on a unit during blasting. The majority of recorded force changes in the legs has been caused by a dynamic interaction of the roof. They are characterized by a load increase coefficient K d, satisfying the inequality 1 06<K d =F m /F st,p <1 24. A much smaller number of cases, when the external load acted on the bases, was recorded. Individual, recorded results of measurements indicate that changes of the force in the legs, caused by external loads of this type, run more intensively due to roof loads (1 08< K d<1 80),particularly in these cases when the near the roof layer of the seam is under mining. A determination of more precise relations among the changes of forces in the legs, caused by a dynamic interaction of the floor and the bases and the mining and geological conditions requires a performance of additional underground tests. 展开更多
关键词 LONGWALL bumping hazard powered roof support unit
在线阅读 下载PDF
A Numerical Prediction of Tip Vortices from Tandem Propellers in the Counter-Rotating Type Tidal Stream Power Unit
20
作者 Hoyun Jung Toshiaki Kanemoto Pin Liu 《Journal of Power and Energy Engineering》 2017年第12期66-74,共9页
Ocean energy has a potential of providing a large amount of renewable energy around the world. One of the forms of ocean energy, tidal stream power is widely recognized as the continuous, predictable and eco-friendly ... Ocean energy has a potential of providing a large amount of renewable energy around the world. One of the forms of ocean energy, tidal stream power is widely recognized as the continuous, predictable and eco-friendly ocean energy source. Unique tandem propellers that can counter-rotate have been designed to generate electric power effectively from a tidal stream. This type of power unit has several advantages compare to the conventional unit with a single propeller. At the design of the tidal stream power unit, it is important to investigate the structure of the tip vortex tubes shedding to predict the load of the propeller. In this research, we investigated the tip vortex shedding using the CFD method for the conventional single propeller and counter-rotating type tandem propellers and estimated the performance efficiency using RANS (Reynolds Averaged Navier-Stokes) model and we confirmed the limitation of RANS model on the calculation of the tip vortex stretching. 展开更多
关键词 TIDAL Stream power unit Counter-Rotation CFD (Computational Fluid Dynamics) TIP VORTICES MRF (Multiple Reference Frame) TANDEM PROPELLERS
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部