To elucidate the effect of calcite-regulated activated carbon(AC)structure on low-temperature denitrification performance of SCR catalysts,this work prepared a series of Mn-Ce/De-AC-xCaCO_(3)(x is the calcite content ...To elucidate the effect of calcite-regulated activated carbon(AC)structure on low-temperature denitrification performance of SCR catalysts,this work prepared a series of Mn-Ce/De-AC-xCaCO_(3)(x is the calcite content in coal)catalysts were prepared by the incipient wetness impregnation method,followed by acid washing to remove calcium-containing minerals.Comprehensive characterization and low-temperature denitrification tests revealed that calcite-induced structural modulation of coal-derived AC significantly enhances catalytic activity.Specifically,NO conversion increased from 88.3%of Mn-Ce/De-AC to 91.7%of Mn-Ce/De-AC-1CaCO_(3)(210℃).The improved SCR denitrification activity results from the enhancement of physicochemical properties including higher Mn^(4+)content and Ce^(4+)/Ce^(3+)ratio,an abundance of chemisorbed oxygen and acidic sites,which could strengthen the SCR reaction pathways(richer NH_(3)activated species and bidentate nitrate active species).Therefore,NO removal is enhanced.展开更多
With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier un...With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier unit(DRU)and a modular multilevel converter(MMC)have emerged as a promising solution,offering advantages in cost-effectiveness and control capability.However,the uncontrollable nature of the DRU poses significant challenges for systemstability under offshore AC fault conditions,particularly due to its inability to provide fault current or voltage support.This paper investigates the offshore AC fault characteristics and fault ride-through(FRT)strategy of a hybrid offshore wind power transmission system based on a diode rectifier unit DRU and MMC.First,the dynamic response of the hybrid system under offshore symmetrical three-phase faults is analyzed.It is demonstrated that due to the unidirectional conduction nature of the DRU,its AC current rapidly drops to zero during faults,and the fault current is solely contributed by the wind turbine generators(WTGs)and wind farm MMC(WFMMC).Based on this analysis,a coordinated FRT strategy is proposed,which combines a segmented current limiting control for the wind-turbine(WT)grid-side converters(GSCs)and a constant AC current control for the WFMMC.The strategy ensures effective voltage support during the fault and prevents MMC current saturation during fault recovery,enabling fast and stable system restoration.Electromagnetic transient simulations in PSCAD/EMTDC verify the feasibility of the proposed fault ride-through strategy.展开更多
Severe acute pancreatitis(SAP)can induce acute respiratory distress syndrome(ARDS)and abdominal compartment syndrome(ACS).Although prone position ventilation(PPV)can improve outcomes in patients with ARDS,there is sig...Severe acute pancreatitis(SAP)can induce acute respiratory distress syndrome(ARDS)and abdominal compartment syndrome(ACS).Although prone position ventilation(PPV)can improve outcomes in patients with ARDS,there is significant controversy regarding its concurrent use with ACS owing to concerns of increased risk of intra-abdominal pressure(IAP).[1]We present a case of successful PPV application without adverse eff ects.展开更多
单级式双有源桥(dual active bridge,DAB)DC/AC变换器控制自由度多,变压器匝比、漏感、开关频率等参数相互耦合,导致变换器效率优化面临多重制约。该文分析变压器匝比、漏感与软开关范围、漏感电流有效值、漏感电流峰值之间的约束关系,...单级式双有源桥(dual active bridge,DAB)DC/AC变换器控制自由度多,变压器匝比、漏感、开关频率等参数相互耦合,导致变换器效率优化面临多重制约。该文分析变压器匝比、漏感与软开关范围、漏感电流有效值、漏感电流峰值之间的约束关系,提出直接表征DAB-DC/AC变换器效率的物理量:效率敏感因子。通过研究效率敏感因子对系统损耗的影响机理,实现变换器效率最优的硬件参数设计,为多参数耦合的单级式DAB-DC/AC变换器效率优化提供理论指导。最后通过一台450 W样机验证所提理论的正确性。展开更多
基金Supported by the Science and Technology Cooperation and Exchange special project of Cooperation of Shanxi Province(202404041101014)the Fundamental Research Program of Shanxi Province(202403021212333)+3 种基金the Joint Funds of the National Natural Science Foundation of China(U24A20555)the Lvliang Key R&D of University-Local Cooperation(2023XDHZ10)the Initiation Fund for Doctoral Research of Taiyuan University of Science and Technology(20242026)the Outstanding Doctor Funding Award of Shanxi Province(20242080).
文摘To elucidate the effect of calcite-regulated activated carbon(AC)structure on low-temperature denitrification performance of SCR catalysts,this work prepared a series of Mn-Ce/De-AC-xCaCO_(3)(x is the calcite content in coal)catalysts were prepared by the incipient wetness impregnation method,followed by acid washing to remove calcium-containing minerals.Comprehensive characterization and low-temperature denitrification tests revealed that calcite-induced structural modulation of coal-derived AC significantly enhances catalytic activity.Specifically,NO conversion increased from 88.3%of Mn-Ce/De-AC to 91.7%of Mn-Ce/De-AC-1CaCO_(3)(210℃).The improved SCR denitrification activity results from the enhancement of physicochemical properties including higher Mn^(4+)content and Ce^(4+)/Ce^(3+)ratio,an abundance of chemisorbed oxygen and acidic sites,which could strengthen the SCR reaction pathways(richer NH_(3)activated species and bidentate nitrate active species).Therefore,NO removal is enhanced.
基金funded by the Science and Technology Projects of State Grid Zhejiang Electric Power Co.,Ltd.(5211DS24000G).
文摘With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier unit(DRU)and a modular multilevel converter(MMC)have emerged as a promising solution,offering advantages in cost-effectiveness and control capability.However,the uncontrollable nature of the DRU poses significant challenges for systemstability under offshore AC fault conditions,particularly due to its inability to provide fault current or voltage support.This paper investigates the offshore AC fault characteristics and fault ride-through(FRT)strategy of a hybrid offshore wind power transmission system based on a diode rectifier unit DRU and MMC.First,the dynamic response of the hybrid system under offshore symmetrical three-phase faults is analyzed.It is demonstrated that due to the unidirectional conduction nature of the DRU,its AC current rapidly drops to zero during faults,and the fault current is solely contributed by the wind turbine generators(WTGs)and wind farm MMC(WFMMC).Based on this analysis,a coordinated FRT strategy is proposed,which combines a segmented current limiting control for the wind-turbine(WT)grid-side converters(GSCs)and a constant AC current control for the WFMMC.The strategy ensures effective voltage support during the fault and prevents MMC current saturation during fault recovery,enabling fast and stable system restoration.Electromagnetic transient simulations in PSCAD/EMTDC verify the feasibility of the proposed fault ride-through strategy.
文摘Severe acute pancreatitis(SAP)can induce acute respiratory distress syndrome(ARDS)and abdominal compartment syndrome(ACS).Although prone position ventilation(PPV)can improve outcomes in patients with ARDS,there is significant controversy regarding its concurrent use with ACS owing to concerns of increased risk of intra-abdominal pressure(IAP).[1]We present a case of successful PPV application without adverse eff ects.
文摘单级式双有源桥(dual active bridge,DAB)DC/AC变换器控制自由度多,变压器匝比、漏感、开关频率等参数相互耦合,导致变换器效率优化面临多重制约。该文分析变压器匝比、漏感与软开关范围、漏感电流有效值、漏感电流峰值之间的约束关系,提出直接表征DAB-DC/AC变换器效率的物理量:效率敏感因子。通过研究效率敏感因子对系统损耗的影响机理,实现变换器效率最优的硬件参数设计,为多参数耦合的单级式DAB-DC/AC变换器效率优化提供理论指导。最后通过一台450 W样机验证所提理论的正确性。