期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines 被引量:1
1
作者 丛浩熹 李庆民 +2 位作者 行晋源 李劲松 陈强 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第6期475-480,共6页
The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental pl... The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. 展开更多
关键词 ac transmission lines secondary arc arcing time dynamic modeling criticallength criterion
在线阅读 下载PDF
AC Line Filter Electrochemical Capacitors:Materials,Morphology,and Configuration 被引量:4
2
作者 Haichao Tang Yang Tian +5 位作者 Zhongshuai Wu Yujia Zeng Yang Wang Yang Hou Zhizhen Ye Jianguo Lu 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2022年第4期1060-1083,共24页
Recently,more and more supercapacitors(SCs)have been developed as AC line filter capacitors,which are generally named AC line filter electrochemical capacitors(FECs).Compared to traditional bulky aluminum electrolytic... Recently,more and more supercapacitors(SCs)have been developed as AC line filter capacitors,which are generally named AC line filter electrochemical capacitors(FECs).Compared to traditional bulky aluminum electrolytic capacitors(AECs),FECs have higher capacity and lower space occupancy,which makes them a strong competitor.However,different from the common SCs for energy storage,it is necessary to consider the frequency response of the SCs for AC line filtering,where the contradiction between frequency response and specific capacitance is a challenge.The researchers have proposed different solutions from the perspective of materials,morphology,and configuration for this challenge.Based on the above background,in this review,we briefly introduce the principle and parameters of AC line filter electrochemical capacitors.We systematically summarize the state-of-the-art progresses of FECs and discuss their possible application and development in the future.The development of FECs can greatly promote the planarization,integration,and miniaturization of filter capacitors,and provide a new solution for the utilization of green and unstable energy. 展开更多
关键词 ac line filtering fast response filter electrochemical capacitors specific capacitance SUPERCAPacITORS
在线阅读 下载PDF
High-frequency supercapacitors with phosphorus-doped Ketjen black 被引量:1
3
作者 Qing Jin Mahima Khandelwal Woong Kim 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第7期464-474,I0010,共12页
Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a h... Compact supercapacitors(SCs)have attracted attention for their great potential to replace bulky aluminum electrolytic capacitors(AECs)in alternating current(AC)line filtering applications.Herein,the fabrication of a high-frequency SC is reported using Ketjen black(KB)nanoparticles doped with phosphorus(P)to achieve a high areal capacitance of up to 2.26 mF cm^(-2)along with a high-rate capability,with a phase angle of-80.2°at 120 Hz.The high performance of the phosphorus-doped KB(designated PKB)SC with a 6 M KOH aqueous electrolyte is associated with its increased surface wettability and additional capacitive sites provided by the P-doping.Density functional theory(DFT)calculations further indicate that the P-doping enhances the interactions between the electrolyte ions and the carbon surface,thus leading to an improved electrochemical performance.These results suggest that the P-doped carbonbased SC could be highly favored in replacing conventional AECs in various high-frequency electronic devices. 展开更多
关键词 Phosphorus doping Frequency response WETTABILITY SUPERCAPacITOR ac line filtering DFT calculation
在线阅读 下载PDF
Alternatingly stacked thin film electrodes-based compact aqueous hybrid electrochemical capacitors for hundred-volts AC line filtering
4
作者 Lixia Wang Lingyu Zhao +8 位作者 Meirong Song Lixia Xie Xiaopeng Wang Xin Li Yanjie Huang Min Wei Qiu Jin Xianglong Meng Yang Zhao 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2023年第3期158-168,I0005,共12页
Filtering capacitor with compact configuration and a wide range of operating voltage has been attracting increasing attention for the smooth conversion of the electric signal in modern circuits.Lossless integration of... Filtering capacitor with compact configuration and a wide range of operating voltage has been attracting increasing attention for the smooth conversion of the electric signal in modern circuits.Lossless integration of capacitor units can be regarded as one of the efficient ways to achieve a wider voltage range,which has not yet been fully conquered due to the lack of rational designs of the electrode structure and integration technology.This study presents an alternatingly stacked assemble technology to conveniently fabricate compact aqueous hybrid integrated filtering capacitors on a large scale,in which a unit consists of rGO/MXene composite film as a negative electrode and PEDOT:PSS based film as a positive electrode.Benefiting from the synergistic effect of rGO and MXene components,and morphological characteristics of PEDOT:PSS,the capacitor unit exhibits outstanding AC line filtering with a large areal specific energy density of 1,015 μF V^(2)cm^(-2)(0.28 μW h cm^(-2)) at 120 Hz.After rational integration,the assembled capacitors present compact/lightweight configuration and lossless frequency response,as reflected by almost constant resistor-capacitor time constant of 0.2 ms and dissipation factor of 15% at120 Hz,identical to those of the single capacitor unit.Apart from standing alone steadily on a flower,a small volume(only 8.1 cm^(3)) of the integrated capacitor with 70 units connected in series achieves hundred-volts alternating current line filtering,which is superior to most reported filtering capacitors with sandwich configuration.This study provides insight into the fabrication and application of compact/ultralight filtering capacitors with lossless frequency response,and a wide range of operating voltage. 展开更多
关键词 Alternatingly stacked assembly Lossless integration Aqueous hybrid electrochemical capacitor Synergistic effect Morphological characteristics COMPacT Hundred-volts ac linefiltering
在线阅读 下载PDF
Design of 1000-kV AC Single-Circuit Overhead Transmission Line
5
作者 Li Yongwei1,Yuan Jun2,Zhao Quanjiang3,Cao Yujie4,Chen Haibo21.China Power Engineering Consulting Group Corporation 2.State Grid Corporation of China +1 位作者 3.Central Southern China Electric Power Design Institute 4.North China Electric Power Design Institute Co.Ltd. Wang Xingguo 《Electricity》 2010年第3期38-42,共5页
The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV ov... The UHVAC 1 000-kV transmission system is so far the one with the most advanced transmission technique applied and highest operation voltage.There are no guidelines or standards available for the design of 1 000-kV overhead transmission line in China.Study on key technologies and design schemes shall be carried out to ascertain the technical principles and construction standards for project construction,which are presented in this paper based on the Southeast Shanxi-Nanyang-Jingmen test and demonstration transmission line.A comparison and analysis of technical data and economic indices between UHV line and other lines are also described. 展开更多
关键词 1 000-kV ac transmission test and demonstration project overhead line design
在线阅读 下载PDF
Statistical Analysis of Radio Interference of 1000 kV UHV AC Double-circuit Transmission Lines in Foul Weather 被引量:3
6
作者 Huichun Xie Xiang Cui +1 位作者 Baoquan Wan Jiangong Zhang 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第2期47-55,共9页
Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term... Analyzing the impact of radio interference(RI)variation during foul weather conditions is an area that has received limited study.This paper provides a statistical analysis of RI measurements obtained from a long-term observation station close to the world’s first commercially operating 1000 kV UHV AC double-circuit transmission line in China.During six months of observations,the impact of RI was studied on the line during fog,drizzle,and light snow and rain.It was found that RI increases linearly with the natural logarithm of the precipitation intensity.The Levenberg-Marquardt algorithm(LMA)is employed to fit the RI value with the precipitation intensity.The reasonable distribution of RI in different foul weather is verified by one-sample K-S test.This test is seen as beneficial for further RI prediction based on statistical weather mode. 展开更多
关键词 1000 kV UHV ac double-circuit transmission line foul weather precipitation intensity radio interference statistical analysis
原文传递
A fast boundary protection for an AC transmission line connected to an LCCHVDC inverter station 被引量:10
7
作者 Zhen Liu Houlei Gao +2 位作者 Sibei Luo Le Zhao Yuyao Feng 《Protection and Control of Modern Power Systems》 2020年第1期328-339,共12页
For AC transmission lines connected to an LCC-HVDC inverter station,commutation failure can lead to the wrong operation of traditional protection.To solve the problem,this paper proposes a fast protection scheme using... For AC transmission lines connected to an LCC-HVDC inverter station,commutation failure can lead to the wrong operation of traditional protection.To solve the problem,this paper proposes a fast protection scheme using transient information from one end of the AC line.The boundary frequency characteristics of the AC line connected to LCC-HVDC inverter are analyzed first.This reveals the existence of significant attenuation on both high frequency signals and some specific frequency signals.Based on the boundary characteristics,a novel boundary protection principle utilizing a backward traveling wave is then proposed.A PSCAD/EMTDC simulation model of a±800 kV LCC-HVDC and 500 kV AC transmission system is established,and different fault cases are simulated.The simulation results prove that the novel protection principle is immune to commutation failure,fault resistance and fault type. 展开更多
关键词 LCC-HVDC Commutation failure Transient protection ac transmission line Inverter station Boundary characteristics
在线阅读 下载PDF
Audible Noise Performance of High Voltage AC Conductor Bundles at an Altitude of 226lm 被引量:2
8
作者 Wangling He Baoquan Wan +3 位作者 Shilong Huang Yunpeng Liu Jiangong Zhang Xiao Han 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第6期2447-2455,共9页
Extra or ultra-high voltage transmission lines can exhibit strong corona discharge and generate severe audible noise(AN)at high altitudes,which has become a critical limiting factor for power lines construction.Howeve... Extra or ultra-high voltage transmission lines can exhibit strong corona discharge and generate severe audible noise(AN)at high altitudes,which has become a critical limiting factor for power lines construction.However,the AN data of bundle conductors at high altitudes are very rare,which cannot adequately support the power utilities to make reasonable conductor selections.In this paper,a sound pressure level(SPL)of 14 types of bundle conductors is investigated by using an ultra-high-voltage(UHV)corona cage(8 m×8 m×35 m)at an altitude of 2216 m,where the bundle numbers between 4 and 12 and the conductor types are used in 500 kV,750 kV or 1000 kV power transmission projects.Then a large number of valuable AN data are obtained;the influences of bundle numbers and sub-conductor diameters on an acoustic power density level(LPWL)are analyzed;and an A-weighted LPWL calculation method is proposed.In addition,by comparing the AN data obtained from the low-altitude area(altitude:23 m),the AN altitude correction factor is concluded,and the influences of conductor parameters and the surface electric field strength on correction factors are discussed.The results obtained in this paper can provide important data for the construction of high-altitude AC power lines. 展开更多
关键词 ac power lines audible noise corona discharge high altitude
原文传递
上一页 1 下一页 到第