With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier un...With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier unit(DRU)and a modular multilevel converter(MMC)have emerged as a promising solution,offering advantages in cost-effectiveness and control capability.However,the uncontrollable nature of the DRU poses significant challenges for systemstability under offshore AC fault conditions,particularly due to its inability to provide fault current or voltage support.This paper investigates the offshore AC fault characteristics and fault ride-through(FRT)strategy of a hybrid offshore wind power transmission system based on a diode rectifier unit DRU and MMC.First,the dynamic response of the hybrid system under offshore symmetrical three-phase faults is analyzed.It is demonstrated that due to the unidirectional conduction nature of the DRU,its AC current rapidly drops to zero during faults,and the fault current is solely contributed by the wind turbine generators(WTGs)and wind farm MMC(WFMMC).Based on this analysis,a coordinated FRT strategy is proposed,which combines a segmented current limiting control for the wind-turbine(WT)grid-side converters(GSCs)and a constant AC current control for the WFMMC.The strategy ensures effective voltage support during the fault and prevents MMC current saturation during fault recovery,enabling fast and stable system restoration.Electromagnetic transient simulations in PSCAD/EMTDC verify the feasibility of the proposed fault ride-through strategy.展开更多
Due to low investment cost and high reliability,a new scheme called DR-HVDC(Diode Rectifier based HVDC)transmission was recently proposed for grid integration of large offshore wind farms.However,in this scheme,the ap...Due to low investment cost and high reliability,a new scheme called DR-HVDC(Diode Rectifier based HVDC)transmission was recently proposed for grid integration of large offshore wind farms.However,in this scheme,the application of conventional control strategies for stability operation face several challenges due to the uncontrollability of the DR.In this paper,a coordinated control strategy of offshore wind farms using the DR-HVDC transmission technology to connect with the onshore grid,is investigated.A novel coordinated control strategy for DR-HVDC is proposed based on the analysis of the DC current control ability of the full-bridge-based modular multilevel converter(FB-MMC)at the onshore station and the input and output characteristics of the diode rectifier at the offshore.Considering the characteristics of operation stability and decoupling between reactive power and active power,a simplified design based on double-loop droop control for offshore AC voltage is proposed after power flow and voltage–current(I–V)characteristics of the offshore wind farm being analyzed.Furthermore,the impact of onshore AC fault to offshore wind farm is analyzed,and a fast fault detection and protection strategy without relying on communication is proposed.Case studies carried out by PSCAD/EMTDC verify the effectiveness of the proposed control strategy for the start up,power fluctuation,and onshore and offshore fault conditions.展开更多
This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operatin...This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.展开更多
基金funded by the Science and Technology Projects of State Grid Zhejiang Electric Power Co.,Ltd.(5211DS24000G).
文摘With the rapid development of large-scale offshore wind farms,efficient and reliable power transmission systems are urgently needed.Hybrid high-voltage direct current(HVDC)configurations combining a diode rectifier unit(DRU)and a modular multilevel converter(MMC)have emerged as a promising solution,offering advantages in cost-effectiveness and control capability.However,the uncontrollable nature of the DRU poses significant challenges for systemstability under offshore AC fault conditions,particularly due to its inability to provide fault current or voltage support.This paper investigates the offshore AC fault characteristics and fault ride-through(FRT)strategy of a hybrid offshore wind power transmission system based on a diode rectifier unit DRU and MMC.First,the dynamic response of the hybrid system under offshore symmetrical three-phase faults is analyzed.It is demonstrated that due to the unidirectional conduction nature of the DRU,its AC current rapidly drops to zero during faults,and the fault current is solely contributed by the wind turbine generators(WTGs)and wind farm MMC(WFMMC).Based on this analysis,a coordinated FRT strategy is proposed,which combines a segmented current limiting control for the wind-turbine(WT)grid-side converters(GSCs)and a constant AC current control for the WFMMC.The strategy ensures effective voltage support during the fault and prevents MMC current saturation during fault recovery,enabling fast and stable system restoration.Electromagnetic transient simulations in PSCAD/EMTDC verify the feasibility of the proposed fault ride-through strategy.
基金supported by State Grid Science and Technology Project“Study on Key Technologies of Large Scale Offshore Wind Power Integrating with Onshore Grid”(4000-202055045A-0-0-00)
文摘Due to low investment cost and high reliability,a new scheme called DR-HVDC(Diode Rectifier based HVDC)transmission was recently proposed for grid integration of large offshore wind farms.However,in this scheme,the application of conventional control strategies for stability operation face several challenges due to the uncontrollability of the DR.In this paper,a coordinated control strategy of offshore wind farms using the DR-HVDC transmission technology to connect with the onshore grid,is investigated.A novel coordinated control strategy for DR-HVDC is proposed based on the analysis of the DC current control ability of the full-bridge-based modular multilevel converter(FB-MMC)at the onshore station and the input and output characteristics of the diode rectifier at the offshore.Considering the characteristics of operation stability and decoupling between reactive power and active power,a simplified design based on double-loop droop control for offshore AC voltage is proposed after power flow and voltage–current(I–V)characteristics of the offshore wind farm being analyzed.Furthermore,the impact of onshore AC fault to offshore wind farm is analyzed,and a fast fault detection and protection strategy without relying on communication is proposed.Case studies carried out by PSCAD/EMTDC verify the effectiveness of the proposed control strategy for the start up,power fluctuation,and onshore and offshore fault conditions.
基金This work is supported by UK EPSRC and UK National Grid.
文摘This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.