Lithium ion capacitors(LICs)have been widely used as energy storage devices due to their high energy density and high power density.For LICs,pre-lithiation of negative electrode is necessary.In this work,we employ a b...Lithium ion capacitors(LICs)have been widely used as energy storage devices due to their high energy density and high power density.For LICs,pre-lithiation of negative electrode is necessary.In this work,we employ a bifunctional Li6CoO4(LCO)as cathodic pre-lithiation reagent to improve the electrochemical performance of LICs.The synthesized LCO exhibited high first charge specific capacity of 721 mAh g-1and extremely low initial coulombic efficiency of 3.19%,providing sufficient Li+ for the pre-lithiation of negative electrode in the first charge.Simultaneously,Li6–xCoOy is generated from LCO during the first charge process,which exhibits pseudocapacitive property and contributes to capacity in form of surface capacitance during subsequent cycles,increasing the capacity of capacitive positive electrode.With the appropriate amounts of addition to the positive side in LICs,this bifunctional prelithiation reagent LCO shows significantly improved the electrochemical performance with the energy density of 78.5 Wh kg-1after 300 cycles between 2.0 and 4.2 V at 250 mA g-1.展开更多
The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ou...The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.展开更多
Deuteriodifluoromethyl(CF_(2)D)is a challenging and important functional group due to difficult deuterium incorporation and lack of effective precursor reagents.Herein,we report a bench-stable reagent,deuteriodifluoro...Deuteriodifluoromethyl(CF_(2)D)is a challenging and important functional group due to difficult deuterium incorporation and lack of effective precursor reagents.Herein,we report a bench-stable reagent,deuteriodifluoromethyl phosphine(DDFP)from cheap deuterium source for selectivity deuteriodifluoromethylation of azines with a high deuterium incorporation yield.The late-stage modification of complex molecules further confirmed the potential of this reagent for practical applications.We expect that our reagent to find applications in synthesis of isotope-labelled molecules of interests for drug-discovery and related ilucidation of mechanism of action.展开更多
A selective and new spectrophotometric method is described for determination of five 1,4 dihydropyridine drugs (1,4- DHP);namely nifedipine (NIF), nicardipine (NIC), nimodipine (NIM), felodipine (FEL) and amlodipine (...A selective and new spectrophotometric method is described for determination of five 1,4 dihydropyridine drugs (1,4- DHP);namely nifedipine (NIF), nicardipine (NIC), nimodipine (NIM), felodipine (FEL) and amlodipine (AML). The method is based on a coupling reaction between the cited drugs and vanillin reagent in acidic condition. Under optimized conditions, the red coloured products were measured at 500 nm for NIF, NIC, NIM and FEL or at 479 nm for AML. Molar absorptivities were ranged from 0.575 × 104 - 1.065 × 104 l·mol-1·cm-1, Beer’s law was obeyed at 5 - 70 μg/mL concentration range and the limit of detection was ranged from 0.150 - 1.500 μg/mL. The proposed method was successfully extended to pharmaceutical preparations tablets and capsules and comparison by Student’s t-test and variance ratio F-test showed no significant difference.展开更多
基金supported by the National Natural Science Foundation of China (51974370)the Program of Huxiang Young Talents (2019RS2002)the Innovation and Entrepreneurship Project of Hunan Province, China (Grant No.2018GK5026)。
文摘Lithium ion capacitors(LICs)have been widely used as energy storage devices due to their high energy density and high power density.For LICs,pre-lithiation of negative electrode is necessary.In this work,we employ a bifunctional Li6CoO4(LCO)as cathodic pre-lithiation reagent to improve the electrochemical performance of LICs.The synthesized LCO exhibited high first charge specific capacity of 721 mAh g-1and extremely low initial coulombic efficiency of 3.19%,providing sufficient Li+ for the pre-lithiation of negative electrode in the first charge.Simultaneously,Li6–xCoOy is generated from LCO during the first charge process,which exhibits pseudocapacitive property and contributes to capacity in form of surface capacitance during subsequent cycles,increasing the capacity of capacitive positive electrode.With the appropriate amounts of addition to the positive side in LICs,this bifunctional prelithiation reagent LCO shows significantly improved the electrochemical performance with the energy density of 78.5 Wh kg-1after 300 cycles between 2.0 and 4.2 V at 250 mA g-1.
文摘The electrochemiluminescence (ECL) of a new reagent 6- (2-hydroxy- 4 diethy laminophenylazo)-2,3-dihydro-1 ,4-phthalazine-1,4-dione (HDEA) in a basic aqueous so lution was studied by using the apparatus designed by ourselves. Trace amounts of silver ( Ⅰ ) shows a significant effect on the efficiency of light emission of HDEA during a positive trigonometrical wave pulse was exerted on the solution. The linear relationship between the light intensity and the concentration of silver( Ⅰ ) occurs in the range of 5. 0×10-8 to 3. 0×10-8 mol/L Ag(Ⅰ ) in a medium of KOH-KCl-HDEA (pH= 12. 8). The detection limit of the method is 2. 0×10-8 mol/LAg( Ⅰ ), and the r. s. d. for 1.0×10-7 mo)/L Ag ( Ⅰ ) is 5%. Of 21 metal ions concerned, only nickel( Ⅱ ), cerium( Ⅳ ) and cobalt( Ⅱ ) interfere the silver detection seriously; Ⅰ and Br also have some interference.
基金financial supported by Innovation Program of Shanghai Municipal Education Commission(No.201701070002E00037)supported by National Key Research Program of China(No.2017YFD0200505)the Fundamental Research Funds for the Central Universities。
文摘Deuteriodifluoromethyl(CF_(2)D)is a challenging and important functional group due to difficult deuterium incorporation and lack of effective precursor reagents.Herein,we report a bench-stable reagent,deuteriodifluoromethyl phosphine(DDFP)from cheap deuterium source for selectivity deuteriodifluoromethylation of azines with a high deuterium incorporation yield.The late-stage modification of complex molecules further confirmed the potential of this reagent for practical applications.We expect that our reagent to find applications in synthesis of isotope-labelled molecules of interests for drug-discovery and related ilucidation of mechanism of action.
文摘A selective and new spectrophotometric method is described for determination of five 1,4 dihydropyridine drugs (1,4- DHP);namely nifedipine (NIF), nicardipine (NIC), nimodipine (NIM), felodipine (FEL) and amlodipine (AML). The method is based on a coupling reaction between the cited drugs and vanillin reagent in acidic condition. Under optimized conditions, the red coloured products were measured at 500 nm for NIF, NIC, NIM and FEL or at 479 nm for AML. Molar absorptivities were ranged from 0.575 × 104 - 1.065 × 104 l·mol-1·cm-1, Beer’s law was obeyed at 5 - 70 μg/mL concentration range and the limit of detection was ranged from 0.150 - 1.500 μg/mL. The proposed method was successfully extended to pharmaceutical preparations tablets and capsules and comparison by Student’s t-test and variance ratio F-test showed no significant difference.