A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopt...A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopts an inte-grated approach,combining the shift register analysis mode with the pulse-position timestamp mode using an FPGA.The optimal effective length of the^(3)He neutron detector was determined to be 30 cm,and the thickness of the graphite reflector was ascertained to be 15 cm through MCNP simulations.After fabricating the device,calibration measurements were per-formed using a^(252)Cf neutron source;a detection efficiency of 43.07%and detector die-away time of 55.79μs were observed.Nine samples of plutonium oxide were measured under identical conditions using the FH-NCM/S1 in shift register analysis mode and a plutonium waste multiplicity counter.The obtained double rates underwent corrections for detection efficiency(ε)and double gate fraction(f_(d)),resulting in corrected double rates(D_(c)),which were used to validate the accuracy of the shift register analysis mode.Furthermore,the device exhibited fluctuations in the measurement results,and within a single 20 s measurement,these fluctuations remained below 10%.After 30 cycles,the relative error in the mass of^(240)Pu was less than 5%.Finally,correlation calculations confirmed the robust consistency of both measurement modes.This study holds specific significance for the subsequent design and development of neutron multiplicity devices.展开更多
为探究药液性质对喷头雾化的影响,该文应用粒子图像分析系统、高速摄影仪及粒径分析仪对ST110-03喷头与IDK120-03喷头进行试验研究,分析了水分散性粒剂Don-q、乳油Score及2种药剂条件下助剂Breakthru S240浓度对雾化区及雾滴谱的影响。...为探究药液性质对喷头雾化的影响,该文应用粒子图像分析系统、高速摄影仪及粒径分析仪对ST110-03喷头与IDK120-03喷头进行试验研究,分析了水分散性粒剂Don-q、乳油Score及2种药剂条件下助剂Breakthru S240浓度对雾化区及雾滴谱的影响。未添加助剂时,农药剂型不同,2类喷头的雾化区及雾滴体积中径(volume medium diameter,VMD)均发生显著变化,水分散性粒剂溶液与自来水的雾化区结构、液膜长度和VMD相差不大;乳油溶液可以使2类喷头的雾化区结构发生显著变化,液膜长度分别减小35.2%和40.5%,VMD分别增大13.5%和28.9%;不同剂型农药条件下,随助剂浓度增大,2类喷头液膜区及破碎区结构均发生不同程度的变化,液膜长度均先减小后增大,VMD先增加后减小,即液膜长度变化与VMD变化呈现负相关性。结合药液理化性质研究发现表面张力是影响雾化的重要因素之一。该研究可为田间助剂浓度的添加范围及喷头雾化特性的模拟与模型建立提供参考。展开更多
基金supported by the National Natural Science Foundation of China(No.42374226)Natural Science Foundation of Jiangxi Province(Nos.20232BAB201043 and 20232BCJ23006)+1 种基金a sub-project of the nuclear energy development project of the China National Defense Science and Industry Bureau‘n-γfusion logging method theory research’(No.20201192-01)the Fundamental Science on Radioactive Geology and Exploration Technology Laboratory(No.2022RGET20)。
文摘A passive neutron multiplicity measurement device,FH-NCM/S1,based on field-programmable gate arrays(FPGAs),is developed specifically for measuring the mass of plutonium-240(^(240)Pu)in mixed oxide fuel.FH-NCM/S1 adopts an inte-grated approach,combining the shift register analysis mode with the pulse-position timestamp mode using an FPGA.The optimal effective length of the^(3)He neutron detector was determined to be 30 cm,and the thickness of the graphite reflector was ascertained to be 15 cm through MCNP simulations.After fabricating the device,calibration measurements were per-formed using a^(252)Cf neutron source;a detection efficiency of 43.07%and detector die-away time of 55.79μs were observed.Nine samples of plutonium oxide were measured under identical conditions using the FH-NCM/S1 in shift register analysis mode and a plutonium waste multiplicity counter.The obtained double rates underwent corrections for detection efficiency(ε)and double gate fraction(f_(d)),resulting in corrected double rates(D_(c)),which were used to validate the accuracy of the shift register analysis mode.Furthermore,the device exhibited fluctuations in the measurement results,and within a single 20 s measurement,these fluctuations remained below 10%.After 30 cycles,the relative error in the mass of^(240)Pu was less than 5%.Finally,correlation calculations confirmed the robust consistency of both measurement modes.This study holds specific significance for the subsequent design and development of neutron multiplicity devices.
文摘为探究药液性质对喷头雾化的影响,该文应用粒子图像分析系统、高速摄影仪及粒径分析仪对ST110-03喷头与IDK120-03喷头进行试验研究,分析了水分散性粒剂Don-q、乳油Score及2种药剂条件下助剂Breakthru S240浓度对雾化区及雾滴谱的影响。未添加助剂时,农药剂型不同,2类喷头的雾化区及雾滴体积中径(volume medium diameter,VMD)均发生显著变化,水分散性粒剂溶液与自来水的雾化区结构、液膜长度和VMD相差不大;乳油溶液可以使2类喷头的雾化区结构发生显著变化,液膜长度分别减小35.2%和40.5%,VMD分别增大13.5%和28.9%;不同剂型农药条件下,随助剂浓度增大,2类喷头液膜区及破碎区结构均发生不同程度的变化,液膜长度均先减小后增大,VMD先增加后减小,即液膜长度变化与VMD变化呈现负相关性。结合药液理化性质研究发现表面张力是影响雾化的重要因素之一。该研究可为田间助剂浓度的添加范围及喷头雾化特性的模拟与模型建立提供参考。