In VLBI observations of Vstar, a subsatellite of the Japanese lunar mission SELENE, there were opportunities for lunar grazing occultation when Vstar was very close to the limb of the Moon. This kind of chance made it...In VLBI observations of Vstar, a subsatellite of the Japanese lunar mission SELENE, there were opportunities for lunar grazing occultation when Vstar was very close to the limb of the Moon. This kind of chance made it possible to probe the thin plasma layer above the Moon's surface as a meaningful by-product of VLBI, by using the radio occultation method with coherent radio waves from the S/X bands. The dual-frequency measurements were carried out at Earth-based VLBI stations. In the line-of-sight direction between the satellite and the ground-based tracking station where VLBI measurements were made, the effects of the terrestrial ionosphere, interplanetary plasma and the thin lunar ionosphere mixed together in the combined observables of dual-frequency Doppler shift and phase shift. To separate the variation of the ionospheric total electron content (TEC) near the surface of the Moon from the mixed signal, the influences of the terrestrial ionosphere and interplanetary plasma have been removed by using an extrapolation method based on a short-term trend. The lunar TEC is estimated from the dual-frequency observation for Vstar from UT 22:18 to UT 22:20 on 2008 June 28 at several tracking stations. The TEC results obtained from VLBI sites are identical, however, they are not as remarkable as the result obtained at the Usuda deep space tracking station.展开更多
In this work, the application of a conducting polymer, poly(thionine), modified electrode as matrix to DNA immobilization as well as transducer to label-free DNA hybridization detection was introduced. The electropo...In this work, the application of a conducting polymer, poly(thionine), modified electrode as matrix to DNA immobilization as well as transducer to label-free DNA hybridization detection was introduced. The electropolymerization of thionine onto electrode surface was carried out by a simple two-step method, which involved a preanodization of glassy carbon electrode at a constant positive potential in thionine solution following cyclic voltammetry scans in the solution. Electrochemical detection was performed by differential pulse voltammetry in the electroactivity potential domain of poly(thionine). The resulting poly(thionine) modified electrode showed a good stability and electroactivity in aqueous media during a near neutral pH range. Additionally, the pendant amino groups on the poly(thionine) chains enabled poly(thionine) modified electrode to immobilize phosphate group terminated DNA probe via covalent linkage. Hybridization process induced a clear decrease in poly(thionine) redox current, which was corresponding to the decrease in poly(thionine) electroactivity after double stranded DNA was formed on the polymer film. The detection limit of this electrochemical DNA hybridization sensor was 1.0 × 10^-10mol/L. Compared with complementary sequence, the hybridization signal values of 1-base mismatched and 3-base mismatched samples were 63.9% and 9.2%, respectively.展开更多
文摘In VLBI observations of Vstar, a subsatellite of the Japanese lunar mission SELENE, there were opportunities for lunar grazing occultation when Vstar was very close to the limb of the Moon. This kind of chance made it possible to probe the thin plasma layer above the Moon's surface as a meaningful by-product of VLBI, by using the radio occultation method with coherent radio waves from the S/X bands. The dual-frequency measurements were carried out at Earth-based VLBI stations. In the line-of-sight direction between the satellite and the ground-based tracking station where VLBI measurements were made, the effects of the terrestrial ionosphere, interplanetary plasma and the thin lunar ionosphere mixed together in the combined observables of dual-frequency Doppler shift and phase shift. To separate the variation of the ionospheric total electron content (TEC) near the surface of the Moon from the mixed signal, the influences of the terrestrial ionosphere and interplanetary plasma have been removed by using an extrapolation method based on a short-term trend. The lunar TEC is estimated from the dual-frequency observation for Vstar from UT 22:18 to UT 22:20 on 2008 June 28 at several tracking stations. The TEC results obtained from VLBI sites are identical, however, they are not as remarkable as the result obtained at the Usuda deep space tracking station.
基金Project supported by the National Natural Science Foundation of China (No. 29875008).
文摘In this work, the application of a conducting polymer, poly(thionine), modified electrode as matrix to DNA immobilization as well as transducer to label-free DNA hybridization detection was introduced. The electropolymerization of thionine onto electrode surface was carried out by a simple two-step method, which involved a preanodization of glassy carbon electrode at a constant positive potential in thionine solution following cyclic voltammetry scans in the solution. Electrochemical detection was performed by differential pulse voltammetry in the electroactivity potential domain of poly(thionine). The resulting poly(thionine) modified electrode showed a good stability and electroactivity in aqueous media during a near neutral pH range. Additionally, the pendant amino groups on the poly(thionine) chains enabled poly(thionine) modified electrode to immobilize phosphate group terminated DNA probe via covalent linkage. Hybridization process induced a clear decrease in poly(thionine) redox current, which was corresponding to the decrease in poly(thionine) electroactivity after double stranded DNA was formed on the polymer film. The detection limit of this electrochemical DNA hybridization sensor was 1.0 × 10^-10mol/L. Compared with complementary sequence, the hybridization signal values of 1-base mismatched and 3-base mismatched samples were 63.9% and 9.2%, respectively.