In this paper, we studied the process of dissociation unimolecular of the evaporation of H+2n+1 hydrogen clusters according to size, using the Rice-Ramsperger-Kassel-Marcus (RRKM) theory. The rate constants k(E) were ...In this paper, we studied the process of dissociation unimolecular of the evaporation of H+2n+1 hydrogen clusters according to size, using the Rice-Ramsperger-Kassel-Marcus (RRKM) theory. The rate constants k(E) were determined with the use of statistical theory of unimolecular reactions using various approximations. In our work, we used the products frequencies instead of transitions frequencies in the calculation of unimolecular dissociation rates obtained by three models RRKM. The agreement between the experimental cross section ratio and calculated rate ratio with direct count approximation seems to be reasonable.展开更多
AIM To evaluate the usefulness of frozen section diagnosis(FSD) of bile duct margins during surgery for extrahepatic cholangiocarcinoma(CCA). METHODS We retrospectively analyzed 74 consecutive patients who underwent s...AIM To evaluate the usefulness of frozen section diagnosis(FSD) of bile duct margins during surgery for extrahepatic cholangiocarcinoma(CCA). METHODS We retrospectively analyzed 74 consecutive patients who underwent surgery for extrahepatic CCA from 2012 to 2017, during which FSD of bile duct margins was performed. They consisted of 40 distant and 34 perihilar CCAs(45 and 55 bile duct margins, respectively). The diagnosis was classified into three categories: negative, borderline(biliary intraepithelial neoplasia-1 and 2, and indefinite for neoplasia), or positive. FSD in the epithelial layer, subepithelial layer, and total layer was compared with corresponding permanent section diagnosis(PSD) postoperatively.Then, association between FSD and local recurrence was analyzed with special reference to borderline.RESULTS Analysis of 100 duct margins revealed that concordance rate between FSD and PSD was 68.0% in the total layer, 69.0% in the epithelial layer, and 98.0% in the subepithelial layer. The extent of remaining biliary epithelium was comparable between FSD and PSD, and more than half of the margins lost > 50% of the entire epithelium, suggesting low quality of the samples. In FSD, the rate of negative margins decreased and that of borderline and positive margins increased according to the extent of the remaining epithelium. Diagnostic discordance between FSD and PSD was observed in 31 epithelial layers and two subepithelial layers. Alteration from borderline to negative was the most frequent(20 of the 31 epithelial layers). Patients with positive margin in the total and epithelial layers by FSD demonstrated a significantly worse local recurrence-free survival(RFS) compared with patients with borderline and negative margins, which revealed comparable local RFS. Patients with borderline and negative margins in the epithelial layer by PSD also revealed comparable local RFS. These results suggested that epithelial borderline might be regarded substantially as negative. When classifying the status of the epithelial layer either as negative or positive, concordance rates between FSD and PSD in the total, epithelial, and subepithelial layers were 95.0%, 93.0%, and 98.0%, respectively.CONCLUSION During intraoperative assessment of bile duct margin, borderline in the epithelial layer can be substantially regarded as negative, under which condition FSD is comparable to PSD.展开更多
Laser pulse nonlinear transmission measurements through saturable absorbers of known absorption parameters allow the measurement of their energy density. On the other hand, nonlinear transmission measurements of laser...Laser pulse nonlinear transmission measurements through saturable absorbers of known absorption parameters allow the measurement of their energy density. On the other hand, nonlinear transmission measurements of laser pulses of known energy density through absorbing media allow their absorption parameter determination. The peak energy density w0P of second harmonic pulses of a mode-locked titanium sapphire laser at wavelength λP = 400 nm is determined by nonlinear energy transmission measurement TE through the dye ADS084BE (1,4-bis(9-ethyl-3-car-bazovinylene)-2-methoxy-5-(2’-ethyl-hexyloxy)-benzene) in tetrahydrofuran. TE(w0P) calibration curves are calculated for laser pulse peak energy density reading w0P from measured pulse energy transmissions TE. The ground-state absorption cross-section σP and the excited-state absorption cross-section σex at λP, and the number density N0 of the retinal Schiff base isoform RetA in pH 7.4 buffer of the blue-light adapted recombinant rhodopsin fragment of the histidine kinase rhodopsin HKR1 from Chlamydomonas reinhardtii were determined by picosecond titanium sapphire second harmonic laser pulse energy transmission measurement TE through RetA as a function of laser input peak energy density w0P. The complete absorption cross-section spectrum展开更多
(此课选自义务教育课程标准实验教科书《英语》(新目标)Go for it.九年级(全一册))一、设计理念:本节课的教学内容是一节完整的阅读板块,采用单词讲解,读前预测,读中利用寻读和细读的阅读策略提取文章关键信息,读后利用思维导图总结全...(此课选自义务教育课程标准实验教科书《英语》(新目标)Go for it.九年级(全一册))一、设计理念:本节课的教学内容是一节完整的阅读板块,采用单词讲解,读前预测,读中利用寻读和细读的阅读策略提取文章关键信息,读后利用思维导图总结全文信息,然后讲解文章难句的设计思路,培养学生的分析能力和阅读技能。展开更多
Analyzing the mass of behind-armor debris (BAD) generated by Rolled Homogeneous Armor (RHA) subjected to normal penetration of variable cross-section Explosively Formed Projectile (EFP) is the purpose of this paper. S...Analyzing the mass of behind-armor debris (BAD) generated by Rolled Homogeneous Armor (RHA) subjected to normal penetration of variable cross-section Explosively Formed Projectile (EFP) is the purpose of this paper. So theoretical analysis, numerical simulation and experimental data are combined to analyze the influence of variable cross-section characteristic on the time history of crater radius. Moreover the relationships between time history of crater radius (as well as mass of BAD) and the thickness of RHA (from 30mm to 70 mm) and the impact velocity of EFP (1650 m/s to 1860 m/s) are also investigated. The results indicate that: 1) being compared to the variable cross-section characteristic is ignored, the theoretical time history of crater radius is in better agreement with the simulation results when the variable cross-section characteristic is considered;2) being compared to the other three conditions of plug, the theoretical mass of BAD is in the best agreement with the simulation results when the shape of plug is frustum of a cone and the angle between generatrix and bottom is 45- and the axial length of mushroom is considered.展开更多
To verify the performance of the neutron total cross-sectional spectrometer, the neutron total cross section of carbon is initially measured in the energy range of 1 eV to 20 MeV using the time-of-flight method. The m...To verify the performance of the neutron total cross-sectional spectrometer, the neutron total cross section of carbon is initially measured in the energy range of 1 eV to 20 MeV using the time-of-flight method. The measurement is performed at the Back-n white neutron source with a 76-m time-of-flight path using the China Spallation Neutron Source. A multilayer fast fission chamber with 235U and 238U is employed as the neutron detector. The diameter and thickness of the natural graphite sample are 70 mm and 40 mm, respectively. Signal waveforms are collected using a data acquisition system. Off-line data processing was used to obtain the neutron time-of-flight spectra and transmissions. The uncertainty of the counting statistics is generally approximately 3% for each bin in the energy range of 1–20 MeV. It is determined that the results for the neutron total cross section of carbon obtained using ^235U cells are in good agreement with the results obtained using 238U cells within limits of statistical uncertainty. Moreover, the measured total cross sections show good agreement with the broadening evaluated data.展开更多
Effective atomic numbers for photon energy absorption(ZPEA_(eff)) and their corresponding electron numbers (NPEA_(eff)), and effective macroscopic removal cross sections of fast neutrons(RR) were calculated for 27 dif...Effective atomic numbers for photon energy absorption(ZPEA_(eff)) and their corresponding electron numbers (NPEA_(eff)), and effective macroscopic removal cross sections of fast neutrons(RR) were calculated for 27 different types of three-dimensional dosimeters, four types of phantom materials, and water. The values of ZPEA_(eff) and NPEA_(eff) were obtained using the direct method for energies ranging from 10 keV to 20 MeV. Results are presented relative to water, for direct comparison over the range of examined energies. The effect of monomers that are used in polymer gel dosimeters on the water equivalence is discussed. The relation between Σ_R and hydrogen content was studied. Micelle gel dosimeters are highly promising because our results demonstrate perfect matching between the effective atomic number, electron density number, and fast neutron attenuation coefficient of water.展开更多
A study was conducted to describe midwives’ adherence to preoperative care during emergency caesarian section at Bwaila Maternity Wing in 2012 in Malawi. The study utilized a descriptive prospective and retrospective...A study was conducted to describe midwives’ adherence to preoperative care during emergency caesarian section at Bwaila Maternity Wing in 2012 in Malawi. The study utilized a descriptive prospective and retrospective design. A structured questionnaire was administered to all 28 midwives who were directly involved in the preparation of clients for emergency caesarean section. Clients charts were also reviewed using a standard checklist to determine adherence to preoperative care. Data were analyzed using SPSS version 16.0 and descriptive statistics in the form of frequencies and percentages were computed for the dataset. A midwife was supposed to score at least 80% on each component of preoperative care guidelines to be compliant to the stipulated pre-operation standards. The midwives scored above 80% on only four of the 14 preoperative care guidelines which were;bladder catheterization (100%, n = 14), obtaining informed consent (92.9%, n = 12), administration of IV (96.4%, n = 13) and administration of preoperative antibiotics (82.1%, n = 11). Midwives however scored less than 80% on preoperative procedures that dealt with vital signs (28.6%, n = 4): BP check (28.6%, n = 4);Pulse rate check (25%, n = 3.5);respiration check (25%, n = 3.5) and temperature check (25%, n = 3.5). The midwives scored further below standard on blood specimen collection (78.6%, n = 11). Psychological support to clients was also below standard at 60.7%, n = 8. Other components of psychological support such as surgery information (57.1%, n = 8), allowing clients ask questions (28.6%, n = 4) and answering clients’ questions (25%, n = 3.5) were also scored below standard. Overall the standard of preoperative care was below standard at the facility. Most of the midwives were new graduates, who had never received any in-service training on preoperative care. Therefore in service training it is recommended for the midwives to provide good quality of care.展开更多
文摘In this paper, we studied the process of dissociation unimolecular of the evaporation of H+2n+1 hydrogen clusters according to size, using the Rice-Ramsperger-Kassel-Marcus (RRKM) theory. The rate constants k(E) were determined with the use of statistical theory of unimolecular reactions using various approximations. In our work, we used the products frequencies instead of transitions frequencies in the calculation of unimolecular dissociation rates obtained by three models RRKM. The agreement between the experimental cross section ratio and calculated rate ratio with direct count approximation seems to be reasonable.
基金JSPS KAKENHI(No.JP16K08695)from the Ministry of Education,Culture,Sports,Science and Technology of Japan
文摘AIM To evaluate the usefulness of frozen section diagnosis(FSD) of bile duct margins during surgery for extrahepatic cholangiocarcinoma(CCA). METHODS We retrospectively analyzed 74 consecutive patients who underwent surgery for extrahepatic CCA from 2012 to 2017, during which FSD of bile duct margins was performed. They consisted of 40 distant and 34 perihilar CCAs(45 and 55 bile duct margins, respectively). The diagnosis was classified into three categories: negative, borderline(biliary intraepithelial neoplasia-1 and 2, and indefinite for neoplasia), or positive. FSD in the epithelial layer, subepithelial layer, and total layer was compared with corresponding permanent section diagnosis(PSD) postoperatively.Then, association between FSD and local recurrence was analyzed with special reference to borderline.RESULTS Analysis of 100 duct margins revealed that concordance rate between FSD and PSD was 68.0% in the total layer, 69.0% in the epithelial layer, and 98.0% in the subepithelial layer. The extent of remaining biliary epithelium was comparable between FSD and PSD, and more than half of the margins lost > 50% of the entire epithelium, suggesting low quality of the samples. In FSD, the rate of negative margins decreased and that of borderline and positive margins increased according to the extent of the remaining epithelium. Diagnostic discordance between FSD and PSD was observed in 31 epithelial layers and two subepithelial layers. Alteration from borderline to negative was the most frequent(20 of the 31 epithelial layers). Patients with positive margin in the total and epithelial layers by FSD demonstrated a significantly worse local recurrence-free survival(RFS) compared with patients with borderline and negative margins, which revealed comparable local RFS. Patients with borderline and negative margins in the epithelial layer by PSD also revealed comparable local RFS. These results suggested that epithelial borderline might be regarded substantially as negative. When classifying the status of the epithelial layer either as negative or positive, concordance rates between FSD and PSD in the total, epithelial, and subepithelial layers were 95.0%, 93.0%, and 98.0%, respectively.CONCLUSION During intraoperative assessment of bile duct margin, borderline in the epithelial layer can be substantially regarded as negative, under which condition FSD is comparable to PSD.
文摘Laser pulse nonlinear transmission measurements through saturable absorbers of known absorption parameters allow the measurement of their energy density. On the other hand, nonlinear transmission measurements of laser pulses of known energy density through absorbing media allow their absorption parameter determination. The peak energy density w0P of second harmonic pulses of a mode-locked titanium sapphire laser at wavelength λP = 400 nm is determined by nonlinear energy transmission measurement TE through the dye ADS084BE (1,4-bis(9-ethyl-3-car-bazovinylene)-2-methoxy-5-(2’-ethyl-hexyloxy)-benzene) in tetrahydrofuran. TE(w0P) calibration curves are calculated for laser pulse peak energy density reading w0P from measured pulse energy transmissions TE. The ground-state absorption cross-section σP and the excited-state absorption cross-section σex at λP, and the number density N0 of the retinal Schiff base isoform RetA in pH 7.4 buffer of the blue-light adapted recombinant rhodopsin fragment of the histidine kinase rhodopsin HKR1 from Chlamydomonas reinhardtii were determined by picosecond titanium sapphire second harmonic laser pulse energy transmission measurement TE through RetA as a function of laser input peak energy density w0P. The complete absorption cross-section spectrum
文摘(此课选自义务教育课程标准实验教科书《英语》(新目标)Go for it.九年级(全一册))一、设计理念:本节课的教学内容是一节完整的阅读板块,采用单词讲解,读前预测,读中利用寻读和细读的阅读策略提取文章关键信息,读后利用思维导图总结全文信息,然后讲解文章难句的设计思路,培养学生的分析能力和阅读技能。
基金financially supported by the National Natural Science Foundation of China(Grant No.11372136)
文摘Analyzing the mass of behind-armor debris (BAD) generated by Rolled Homogeneous Armor (RHA) subjected to normal penetration of variable cross-section Explosively Formed Projectile (EFP) is the purpose of this paper. So theoretical analysis, numerical simulation and experimental data are combined to analyze the influence of variable cross-section characteristic on the time history of crater radius. Moreover the relationships between time history of crater radius (as well as mass of BAD) and the thickness of RHA (from 30mm to 70 mm) and the impact velocity of EFP (1650 m/s to 1860 m/s) are also investigated. The results indicate that: 1) being compared to the variable cross-section characteristic is ignored, the theoretical time history of crater radius is in better agreement with the simulation results when the variable cross-section characteristic is considered;2) being compared to the other three conditions of plug, the theoretical mass of BAD is in the best agreement with the simulation results when the shape of plug is frustum of a cone and the angle between generatrix and bottom is 45- and the axial length of mushroom is considered.
基金supported by the National Key Research and Development Plan(No.2016YFA0401603)the National Natural Science Foundation of China(No.11675155)
文摘To verify the performance of the neutron total cross-sectional spectrometer, the neutron total cross section of carbon is initially measured in the energy range of 1 eV to 20 MeV using the time-of-flight method. The measurement is performed at the Back-n white neutron source with a 76-m time-of-flight path using the China Spallation Neutron Source. A multilayer fast fission chamber with 235U and 238U is employed as the neutron detector. The diameter and thickness of the natural graphite sample are 70 mm and 40 mm, respectively. Signal waveforms are collected using a data acquisition system. Off-line data processing was used to obtain the neutron time-of-flight spectra and transmissions. The uncertainty of the counting statistics is generally approximately 3% for each bin in the energy range of 1–20 MeV. It is determined that the results for the neutron total cross section of carbon obtained using ^235U cells are in good agreement with the results obtained using 238U cells within limits of statistical uncertainty. Moreover, the measured total cross sections show good agreement with the broadening evaluated data.
文摘Effective atomic numbers for photon energy absorption(ZPEA_(eff)) and their corresponding electron numbers (NPEA_(eff)), and effective macroscopic removal cross sections of fast neutrons(RR) were calculated for 27 different types of three-dimensional dosimeters, four types of phantom materials, and water. The values of ZPEA_(eff) and NPEA_(eff) were obtained using the direct method for energies ranging from 10 keV to 20 MeV. Results are presented relative to water, for direct comparison over the range of examined energies. The effect of monomers that are used in polymer gel dosimeters on the water equivalence is discussed. The relation between Σ_R and hydrogen content was studied. Micelle gel dosimeters are highly promising because our results demonstrate perfect matching between the effective atomic number, electron density number, and fast neutron attenuation coefficient of water.
文摘A study was conducted to describe midwives’ adherence to preoperative care during emergency caesarian section at Bwaila Maternity Wing in 2012 in Malawi. The study utilized a descriptive prospective and retrospective design. A structured questionnaire was administered to all 28 midwives who were directly involved in the preparation of clients for emergency caesarean section. Clients charts were also reviewed using a standard checklist to determine adherence to preoperative care. Data were analyzed using SPSS version 16.0 and descriptive statistics in the form of frequencies and percentages were computed for the dataset. A midwife was supposed to score at least 80% on each component of preoperative care guidelines to be compliant to the stipulated pre-operation standards. The midwives scored above 80% on only four of the 14 preoperative care guidelines which were;bladder catheterization (100%, n = 14), obtaining informed consent (92.9%, n = 12), administration of IV (96.4%, n = 13) and administration of preoperative antibiotics (82.1%, n = 11). Midwives however scored less than 80% on preoperative procedures that dealt with vital signs (28.6%, n = 4): BP check (28.6%, n = 4);Pulse rate check (25%, n = 3.5);respiration check (25%, n = 3.5) and temperature check (25%, n = 3.5). The midwives scored further below standard on blood specimen collection (78.6%, n = 11). Psychological support to clients was also below standard at 60.7%, n = 8. Other components of psychological support such as surgery information (57.1%, n = 8), allowing clients ask questions (28.6%, n = 4) and answering clients’ questions (25%, n = 3.5) were also scored below standard. Overall the standard of preoperative care was below standard at the facility. Most of the midwives were new graduates, who had never received any in-service training on preoperative care. Therefore in service training it is recommended for the midwives to provide good quality of care.