[Objectives]This study was conducted to establish a quantitative assessment method for the textural quality of chieh-qua fruit.[Methods]Using two modes of a texture analyzer,namely TPA(texture profile analysis)and pun...[Objectives]This study was conducted to establish a quantitative assessment method for the textural quality of chieh-qua fruit.[Methods]Using two modes of a texture analyzer,namely TPA(texture profile analysis)and puncture,the index data of the fruit were obtained by setting different trigger forces,deformation levels,test speeds,as well as puncture speeds and puncture depths.The data included TPA hardness,adhesiveness,springiness,cohesiveness,gumminess,chewiness,resilience,as well as skin hardness,skin toughness,flesh hardness,fracturability,and compactness.[Results]Different deformation levels had a significant impact on all parameters.Hardness,adhesiveness,gumminess and chewiness showed a trend of first increasing and then decreasing with the deformation level increasing.When the deformation level was 30%,the adhesiveness,gumminess and chewiness reached their maximum values.When the deformation level was 50%,TPA hardness reached its maximum.When the compression speed was 3 mm/s,the measured values of TPA hardness,adhesiveness,chewiness,and resilience were at their maximums.The skin hardness varied significantly under different trigger forces.When the trigger force was 15 g,the skin hardness reached a maximum value of 944.63 g,and the skin toughness,flesh hardness,fracturability,and compactness also reach their maximum values respectively.When the puncture depth was 12 mm,the flesh hardness and skin toughness reached their maximums of 682.51 g and 1.82 mm,respectively.In the TPA mode,the flesh hardness of chieh-qua showed an extremely significant negative correlation with springiness,cohesiveness,and resilience(P<0.01).The fruit fracturability detected by puncture had an extremely significant positive correlation with compactness(P<0.01).[Conclusions]The evaluation method for measuring chieh-qua texture by combining TPA and the puncture mode could accurately and quantitatively reflect the differences in the flesh texture quality of chieh-qua.The optimal parameters for texture measurement of chieh-qua fruit were determined as a 15 g trigger force with 50%deformation and a 3 mm/s compression speed in TPA mode,and a 15 g trigger force with a 12 mm puncture depth in puncture mode.Puncture speed was found to have no significant effect on the texture indices of chieh-qua.展开更多
Left-handedness with three zero-absorption windows is achieved in a triple-quantum-dot system. With the typ- ical parameters of a GaAs/AlGaAs heterostructure, the simultaneous negative relative electric permittivity a...Left-handedness with three zero-absorption windows is achieved in a triple-quantum-dot system. With the typ- ical parameters of a GaAs/AlGaAs heterostructure, the simultaneous negative relative electric permittivity and magnetic permeability are obtained by the adjustable incoherent pumping field and two inter-dot tunnelings. Furthermore, three zero-absorption windows in the left-handedness frequency bands are observed. The left- handedness with zero-absorption in the solid state heterostrueture may solve the challenges not only in the left-handed materials achieved by the photonic resonant scheme but also in the application of negative refractive materials with a large amount of absorption.展开更多
The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.A...The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.As a primary thermal analysis instrument,the simultaneous thermal analyzer(STA)has unique advantages,which combines the functionalities of thermogravimetric(TG)analyzersand differential scanning calorimeters(DSC).However,the absence of standard quality control procedures has resulted in poor measurement reproducibility,low accuracy,and inadequate traceability of analytical results.This study utilized a multi-point temperature calibration method based on national certified reference materials to reduce instrument temperature indication errors.On this basis,we innovatively established a comprehensive quality control system encompassing laboratory environmental control,standard method selection,instrument performance verification,reference material traceability,and uncertainty analysis,thereby achieving standardized operational procedures for thermal analysis measurement.Taking the"determination of initial melting temperature of unknown substances"as a representative case study,a component resolution model for thermal analysis test uncertainty was developed.Through systematic analysis of both the reference material-introduced component and measurement repeatability component,complete traceability of test results was achieved.This approach ensures data validity and enhances the accuracy of test results.This provides crucial technical support and practical reference for the standardization of thermal analysis measurement procedure and assessment of result reliability.展开更多
In the face of the escalating global prevalence of chronic kidney disease(CKD),early diagnosis and effective management have become crucial imperatives[1].The article“Development of a smartphone-integrated handheld a...In the face of the escalating global prevalence of chronic kidney disease(CKD),early diagnosis and effective management have become crucial imperatives[1].The article“Development of a smartphone-integrated handheld automated biochemical analyzer for point-of-care testing of urinary albumin”by Wu et al.[2]presents a novel smartphone-integrated handheld automated biochemical analyzer(sHABA),which offers new possibilities for the early diagnosis and management of CKD,holding great significance for improving patients’health.展开更多
The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due ...The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes.This study presents a smartphone-integrated handheld automated biochemical analyzer(sHABA)designed for point-of-care testing of urinary albumin.The sHABA features a pre-loaded,disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose.The smartphone-integrated analyzer can drive the reagents following a preset program,to enable automatic sequential addition.The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L.The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity(95.78%)and specificity(90.16%).This research advances the field by providing an automated detection method for albumin in a portable device,allowing even untrained individuals to monitor CKD in real time at the patient's bedside.In the context of promoting tiered diagnosis and treatment,the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.展开更多
Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes ...Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes in corneal biomechanical parameters with age and sex.The articles published in PubMed between 2000 and 2021 were investigated and critiqued,and valid scientific evidence was collected,reviewed and concluded according to the inclusion and exclusion criteria.Most studies showed that corneal biomechanical changes occur infrequently in children up to the age of 20y,and with increasing age and wider age range,there was a significant decrease in corneal biomechanical indices,especially corneal hysteresis.In children and adults,most studies have shown that these biomechanical indicators,especially corneal resistance factor,were higher in females.Although hormonal changes may contribute to this finding,the role of axial length and other biometric indicators should not be ignored.The axial length,the intraocular pressure,and the corneal thickness are other factors associated with biomechanical parameters that should be taken into account in clinical diagnosis and management especially for patients undergoing refractive surgery as well as keratoconus patients.展开更多
Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The ...Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.展开更多
In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize k...In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize kernels was carried out using Hitachi L-8900 Automatic Amino-acid Analyzer, to know the effect of the Analyzer in distinguishing the lysine contents between common maize kernels and high-lysine maize kernels. The results showed that the lysine contents of high-lysine maize kernels were among 0.34%-0.42%, while of common maize kernels were a- mong 0.24%-0.25%, and the difference was significant. Compared with other tradi- tional methods, this method is rapid, simple, sensitive, highly reproductive and needs fewer maize kernels, thus it is applicable in maize breeding.展开更多
基金Supported by Shanghai Agriculture Applied Technology Development Program (Grant No.T20220120).
文摘[Objectives]This study was conducted to establish a quantitative assessment method for the textural quality of chieh-qua fruit.[Methods]Using two modes of a texture analyzer,namely TPA(texture profile analysis)and puncture,the index data of the fruit were obtained by setting different trigger forces,deformation levels,test speeds,as well as puncture speeds and puncture depths.The data included TPA hardness,adhesiveness,springiness,cohesiveness,gumminess,chewiness,resilience,as well as skin hardness,skin toughness,flesh hardness,fracturability,and compactness.[Results]Different deformation levels had a significant impact on all parameters.Hardness,adhesiveness,gumminess and chewiness showed a trend of first increasing and then decreasing with the deformation level increasing.When the deformation level was 30%,the adhesiveness,gumminess and chewiness reached their maximum values.When the deformation level was 50%,TPA hardness reached its maximum.When the compression speed was 3 mm/s,the measured values of TPA hardness,adhesiveness,chewiness,and resilience were at their maximums.The skin hardness varied significantly under different trigger forces.When the trigger force was 15 g,the skin hardness reached a maximum value of 944.63 g,and the skin toughness,flesh hardness,fracturability,and compactness also reach their maximum values respectively.When the puncture depth was 12 mm,the flesh hardness and skin toughness reached their maximums of 682.51 g and 1.82 mm,respectively.In the TPA mode,the flesh hardness of chieh-qua showed an extremely significant negative correlation with springiness,cohesiveness,and resilience(P<0.01).The fruit fracturability detected by puncture had an extremely significant positive correlation with compactness(P<0.01).[Conclusions]The evaluation method for measuring chieh-qua texture by combining TPA and the puncture mode could accurately and quantitatively reflect the differences in the flesh texture quality of chieh-qua.The optimal parameters for texture measurement of chieh-qua fruit were determined as a 15 g trigger force with 50%deformation and a 3 mm/s compression speed in TPA mode,and a 15 g trigger force with a 12 mm puncture depth in puncture mode.Puncture speed was found to have no significant effect on the texture indices of chieh-qua.
基金Supported by the National Natural Science Foundation of China under Grant No 61205205the Foundation for Personnel Training Projects of Yunnan Province under Grant No KKSY201207068
文摘Left-handedness with three zero-absorption windows is achieved in a triple-quantum-dot system. With the typ- ical parameters of a GaAs/AlGaAs heterostructure, the simultaneous negative relative electric permittivity and magnetic permeability are obtained by the adjustable incoherent pumping field and two inter-dot tunnelings. Furthermore, three zero-absorption windows in the left-handedness frequency bands are observed. The left- handedness with zero-absorption in the solid state heterostrueture may solve the challenges not only in the left-handed materials achieved by the photonic resonant scheme but also in the application of negative refractive materials with a large amount of absorption.
文摘The accuracy of thermal analysis measurements is critical to analyze material properties correctly,making the improvement of measurement precision and proper uncertainty analysis of test results absolutely essential.As a primary thermal analysis instrument,the simultaneous thermal analyzer(STA)has unique advantages,which combines the functionalities of thermogravimetric(TG)analyzersand differential scanning calorimeters(DSC).However,the absence of standard quality control procedures has resulted in poor measurement reproducibility,low accuracy,and inadequate traceability of analytical results.This study utilized a multi-point temperature calibration method based on national certified reference materials to reduce instrument temperature indication errors.On this basis,we innovatively established a comprehensive quality control system encompassing laboratory environmental control,standard method selection,instrument performance verification,reference material traceability,and uncertainty analysis,thereby achieving standardized operational procedures for thermal analysis measurement.Taking the"determination of initial melting temperature of unknown substances"as a representative case study,a component resolution model for thermal analysis test uncertainty was developed.Through systematic analysis of both the reference material-introduced component and measurement repeatability component,complete traceability of test results was achieved.This approach ensures data validity and enhances the accuracy of test results.This provides crucial technical support and practical reference for the standardization of thermal analysis measurement procedure and assessment of result reliability.
文摘In the face of the escalating global prevalence of chronic kidney disease(CKD),early diagnosis and effective management have become crucial imperatives[1].The article“Development of a smartphone-integrated handheld automated biochemical analyzer for point-of-care testing of urinary albumin”by Wu et al.[2]presents a novel smartphone-integrated handheld automated biochemical analyzer(sHABA),which offers new possibilities for the early diagnosis and management of CKD,holding great significance for improving patients’health.
基金funding by the China Postdoctoral Science Foundation(Grant No.:2021M701628)the National Natural Science Foundation of China(Grant No.:82202625)+3 种基金Science and Technology Projects in Guangzhou,China(Grant No.:SL2022A04J02086)President Foundation of Nanfang Hospital,Southern Medical University,China(Grant Nos.:2021B012,and 2021C050)National Science Fund for Distinguished Young Scholars,China(Grant No.:82025024)Key project of the National Natural Science Foundation of China(Grant No.:82230080).
文摘The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease(CKD).However,existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes.This study presents a smartphone-integrated handheld automated biochemical analyzer(sHABA)designed for point-of-care testing of urinary albumin.The sHABA features a pre-loaded,disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose.The smartphone-integrated analyzer can drive the reagents following a preset program,to enable automatic sequential addition.The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L.The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity(95.78%)and specificity(90.16%).This research advances the field by providing an automated detection method for albumin in a portable device,allowing even untrained individuals to monitor CKD in real time at the patient's bedside.In the context of promoting tiered diagnosis and treatment,the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.
基金Supported by Noor Ophthalmology Research Center.
文摘Biomechanical study of the visual system by ocular response analyzer investigates the inter-structural biological relationships,mechanics,and function of the visual system.This review aimed to investigate the changes in corneal biomechanical parameters with age and sex.The articles published in PubMed between 2000 and 2021 were investigated and critiqued,and valid scientific evidence was collected,reviewed and concluded according to the inclusion and exclusion criteria.Most studies showed that corneal biomechanical changes occur infrequently in children up to the age of 20y,and with increasing age and wider age range,there was a significant decrease in corneal biomechanical indices,especially corneal hysteresis.In children and adults,most studies have shown that these biomechanical indicators,especially corneal resistance factor,were higher in females.Although hormonal changes may contribute to this finding,the role of axial length and other biometric indicators should not be ignored.The axial length,the intraocular pressure,and the corneal thickness are other factors associated with biomechanical parameters that should be taken into account in clinical diagnosis and management especially for patients undergoing refractive surgery as well as keratoconus patients.
基金The National Key Research and Development Program of China under contract Nos 2022YFC3104203 and 2018YFC0213103the Science Foundation of Donghai Laboratory under contract No.DH-2022KF01019+1 种基金the National Natural Science Foundation under contract No.419061522023 Shanghai Education Science Research Project under contract No.C2023120.
文摘Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.
基金Supported by Henan Major Scientific and Technological Project(121100110300)Outstanding Youth Project of Henan Academy of Agricultural Sciences(2013YQ006)~~
文摘In this study, nine high-lysine maize kernels and two kernels of common maize hybrid were used as experiment materials, and quantitative determination of lysine contents in high-lysine maize kernels and common maize kernels was carried out using Hitachi L-8900 Automatic Amino-acid Analyzer, to know the effect of the Analyzer in distinguishing the lysine contents between common maize kernels and high-lysine maize kernels. The results showed that the lysine contents of high-lysine maize kernels were among 0.34%-0.42%, while of common maize kernels were a- mong 0.24%-0.25%, and the difference was significant. Compared with other tradi- tional methods, this method is rapid, simple, sensitive, highly reproductive and needs fewer maize kernels, thus it is applicable in maize breeding.