Parallel converter can significantly increase the capacity of the converter and improve the power quality of AC side, but the circulation which can lead to high switching loss and even damage the devices will easily e...Parallel converter can significantly increase the capacity of the converter and improve the power quality of AC side, but the circulation which can lead to high switching loss and even damage the devices will easily exist in the direct parallel converters. In this paper, the average model of parallel interleaved inverters system to analyze the circulation current is shown, and the cross current is relevant to DC-bus voltage and the overlap time of zero vectors in the switching period. Based on this observation, a discontinuous space vector modulation without using zero vectors (000) is eliminate and suppress the zero-sequence current to entire system. Finally, the effectiveness of modulation strategy is verified by the simulations in this paper.展开更多
The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interl...The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.展开更多
This paper is concerned with two popular and powerful methods in electrical drive applications:fieldoriented control(FOC)and space vector modulation(SVM).The proposed FOC-SVM method is incorporated with a predictive c...This paper is concerned with two popular and powerful methods in electrical drive applications:fieldoriented control(FOC)and space vector modulation(SVM).The proposed FOC-SVM method is incorporated with a predictive current control(PCC)-based technique.The suggested method estimates the desirable electrical torque to track mechanical torque at a fixed speed operation of permanent magnet synchronous motor(PMSM).The estimated torque is used to calculate the reference current based on FOC.In order to improve the performance of the traditional SVM,a PCC method is established as a switching pattern modifier.Therefore,PCC-based SVM is employed to further minimize the torque ripples and transient response.The performance of the controller is evaluated in terms of torque and current ripple and transient response to step variations of the torque command.The proposed method has been verified with MATLAB-Simulink model.Simulation results confirm the ability of this technique in minimizing the torque and speed ripples and fixing switching frequency,simultaneously.However,it is sensitive to parameter changes.展开更多
文摘Parallel converter can significantly increase the capacity of the converter and improve the power quality of AC side, but the circulation which can lead to high switching loss and even damage the devices will easily exist in the direct parallel converters. In this paper, the average model of parallel interleaved inverters system to analyze the circulation current is shown, and the cross current is relevant to DC-bus voltage and the overlap time of zero vectors in the switching period. Based on this observation, a discontinuous space vector modulation without using zero vectors (000) is eliminate and suppress the zero-sequence current to entire system. Finally, the effectiveness of modulation strategy is verified by the simulations in this paper.
基金supported by the National Natural Science Foundation of China(Grant No.51977046)Wuxi University Research Start-up Fund for Introduced Talent(2022r021).
文摘The development of renewable energy power generation for carbon neutrality and energy transition has been increasing worldwide,leading to an increasing demand for high-power conversion.Compared with traditional interleaved paralleling,the integrated paralleling of three-level inverters can further reduce the output harmonics.Moreover,a well-designed switching sequence ensures that the average circulating current is zero,which provides a superior and feasible solution to satisfy the demands of high-power operations.However,a large instantaneous loop current exists between shunt converters,which leads to disadvantages such as higher switching device stress and loss.In this study,by utilizing the state-distribution redundancy provided by the integrated modulation process,a new design for switch-ing sequences is suggested for the integrated modulation of shunt three-level converters.This design aims to reduce the circulating current while better preserving the same output current harmonics than traditional parallel methods.The proposal includes an in-depth analysis and explanation of the implementation process.Finally,the proposed method is validated through simulations and prototype experi-ments.The results indicate that compared with traditional methods,the adoption of the improved switching sequence presented in this study leads to an average reduction of 3.2%in the total harmonic distortion of the inverter’s output and an average decrease of 32%in the amplitude of the circulating current.Both the output harmonics and circulating currents are significantly suppressed across various modulation indices.
文摘This paper is concerned with two popular and powerful methods in electrical drive applications:fieldoriented control(FOC)and space vector modulation(SVM).The proposed FOC-SVM method is incorporated with a predictive current control(PCC)-based technique.The suggested method estimates the desirable electrical torque to track mechanical torque at a fixed speed operation of permanent magnet synchronous motor(PMSM).The estimated torque is used to calculate the reference current based on FOC.In order to improve the performance of the traditional SVM,a PCC method is established as a switching pattern modifier.Therefore,PCC-based SVM is employed to further minimize the torque ripples and transient response.The performance of the controller is evaluated in terms of torque and current ripple and transient response to step variations of the torque command.The proposed method has been verified with MATLAB-Simulink model.Simulation results confirm the ability of this technique in minimizing the torque and speed ripples and fixing switching frequency,simultaneously.However,it is sensitive to parameter changes.