This paper presents the simulation results of DC,small-signal and noise properties of GaP based Double Drift Region( DDR) Impact Avalanche Transit Time( IMPATT) diodes. In simulation study we have considered the flat ...This paper presents the simulation results of DC,small-signal and noise properties of GaP based Double Drift Region( DDR) Impact Avalanche Transit Time( IMPATT) diodes. In simulation study we have considered the flat DDR structures of IMPATT diode based on GaP,GaAs,Si and GaN( wurtzite,wz) material. The diodes are designed to operate at the millimeter window frequencies of 94 GHz and 220 GHz. The simulation results of these diodes reveal GaP is a promising material for IMPATT applications based on DDR structure with high break down voltage( V_B) as compared to Si and GaAs IMPATTs. It is also encouraging to worth note GaP base IMPATT diode shows a better output power density of 4. 9 × 10~9 W/m^2 as compared to Si and GaAs based IMPATT diode. But IMPATT diode based on GaN( wz) displays large values of break down voltage,efficiency and power density as compared to Si,GaAs and GaP IMPATTs.展开更多
This paper introduces the Advanced Observer Model (AOM), a novel framework that integrates classical mechanics, quantum mechanics, and relativity through the observer’s role in constructing reality. Central to the AO...This paper introduces the Advanced Observer Model (AOM), a novel framework that integrates classical mechanics, quantum mechanics, and relativity through the observer’s role in constructing reality. Central to the AOM is the Static Configuration/Dynamic Configuration (SC/DC) conjugate, which examines physical systems through the interaction between static spatial configurations and dynamic quantum states. The model introduces a Constant Frame Rate (CFR) to quantize time perception, providing a discrete model for time evolution in quantum systems. By modifying the Schrödinger equation with CFR, the AOM bridges quantum and classical physics, offering a unified interpretation where classical determinism and quantum uncertainty coexist. A key feature of the AOM is its energy scaling model, where energy grows exponentially with spatial dimensionality, following the relationshipE∝(π)n. This dimensional scaling connects the discrete time perception of the observer with both quantum and classical energy distributions, providing insights into the nature of higher-dimensional spaces. Additionally, the AOM posits that spacetime curvature arises from quantum interactions, shaped by the observer’s discrete time perception. The model emphasizes the observer’s consciousness as a co-creator of reality, offering new approaches to understanding the quantum-classical transition. While speculative, the AOM opens new avenues for addressing foundational questions in quantum mechanics, relativity, dimensionality, and the nature of reality.展开更多
提出一种使用手机摄像头采集脉搏波的血压估计方法,称为基于脉搏波的多参数收缩压估计法(multiparameter estimation of systolic blood pressure based on pulse wave,MBPP).在运动实验中,分别通过手机摄像头和血压仪获得不同的脉搏波...提出一种使用手机摄像头采集脉搏波的血压估计方法,称为基于脉搏波的多参数收缩压估计法(multiparameter estimation of systolic blood pressure based on pulse wave,MBPP).在运动实验中,分别通过手机摄像头和血压仪获得不同的脉搏波时序数据和血压.然后,对脉搏波数据进行去噪,计算加速脉搏波,得到脉搏波传导时间.再计算得到脉搏波的特征点,从而计算心率.最后,选择脉搏波传导时间和心率两个参数与血压进行线性拟合,从而得到血压的回归方程.实验结果表明,MBPP方法准确性高,可以用于血压的测量.展开更多
文摘This paper presents the simulation results of DC,small-signal and noise properties of GaP based Double Drift Region( DDR) Impact Avalanche Transit Time( IMPATT) diodes. In simulation study we have considered the flat DDR structures of IMPATT diode based on GaP,GaAs,Si and GaN( wurtzite,wz) material. The diodes are designed to operate at the millimeter window frequencies of 94 GHz and 220 GHz. The simulation results of these diodes reveal GaP is a promising material for IMPATT applications based on DDR structure with high break down voltage( V_B) as compared to Si and GaAs IMPATTs. It is also encouraging to worth note GaP base IMPATT diode shows a better output power density of 4. 9 × 10~9 W/m^2 as compared to Si and GaAs based IMPATT diode. But IMPATT diode based on GaN( wz) displays large values of break down voltage,efficiency and power density as compared to Si,GaAs and GaP IMPATTs.
文摘This paper introduces the Advanced Observer Model (AOM), a novel framework that integrates classical mechanics, quantum mechanics, and relativity through the observer’s role in constructing reality. Central to the AOM is the Static Configuration/Dynamic Configuration (SC/DC) conjugate, which examines physical systems through the interaction between static spatial configurations and dynamic quantum states. The model introduces a Constant Frame Rate (CFR) to quantize time perception, providing a discrete model for time evolution in quantum systems. By modifying the Schrödinger equation with CFR, the AOM bridges quantum and classical physics, offering a unified interpretation where classical determinism and quantum uncertainty coexist. A key feature of the AOM is its energy scaling model, where energy grows exponentially with spatial dimensionality, following the relationshipE∝(π)n. This dimensional scaling connects the discrete time perception of the observer with both quantum and classical energy distributions, providing insights into the nature of higher-dimensional spaces. Additionally, the AOM posits that spacetime curvature arises from quantum interactions, shaped by the observer’s discrete time perception. The model emphasizes the observer’s consciousness as a co-creator of reality, offering new approaches to understanding the quantum-classical transition. While speculative, the AOM opens new avenues for addressing foundational questions in quantum mechanics, relativity, dimensionality, and the nature of reality.
基金Supported by Advanced Space Medico-Engineering Research Project of China(SJ200903,SJ201006)State Key Laboratory of Space Medicine Fundamentals and Application(SMFA09A16)
文摘提出一种使用手机摄像头采集脉搏波的血压估计方法,称为基于脉搏波的多参数收缩压估计法(multiparameter estimation of systolic blood pressure based on pulse wave,MBPP).在运动实验中,分别通过手机摄像头和血压仪获得不同的脉搏波时序数据和血压.然后,对脉搏波数据进行去噪,计算加速脉搏波,得到脉搏波传导时间.再计算得到脉搏波的特征点,从而计算心率.最后,选择脉搏波传导时间和心率两个参数与血压进行线性拟合,从而得到血压的回归方程.实验结果表明,MBPP方法准确性高,可以用于血压的测量.