期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
The performance analysis and calculation for variable frequency speed control motors with the rotor structure optimized
1
作者 曹君慈 李伟力 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第6期710-714,共5页
In the paper, the method to optimize the rotor structure in variable frequency speed control motors is introduced. The saturation and the skin effect are considered and 2D no-load and load electromagnetic field is cal... In the paper, the method to optimize the rotor structure in variable frequency speed control motors is introduced. The saturation and the skin effect are considered and 2D no-load and load electromagnetic field is calculated in finite elements for a variable frequency speed control motor before and after optimization. Finally, no-load current and operation performance before and after optimization are obtained and the two results are contrasted. 展开更多
关键词 variable frequency speed control optimization design finite element operation performance
在线阅读 下载PDF
The Applications of High-voltage variable frequency speed regulation System in Main Exhauster of Sintering
2
作者 Li Jingwei 《International English Education Research》 2015年第9期8-10,共3页
Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the pro... Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the production. The paper takes an iron and steel enterprise that had successfully transformed the synchronous motors of main exhauster of sintering as an example, which describes the application of high-voltage variable frequency speed regulation system in main exhauster of Sintering, so as to provide a reference for other iron and steel enterprises. 展开更多
关键词 High-voltage variable frequency speed regulation SINTERING main exhauster.
在线阅读 下载PDF
On maximum power point tracking control strategy for variable speed constant frequency wind power generation 被引量:1
3
作者 倪红军 《Journal of Chongqing University》 CAS 2010年第1期21-28,共8页
Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum ... Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy. 展开更多
关键词 variable speed constant frequency grid voltage orientation DECOUPLING maximum power point tracking
在线阅读 下载PDF
Circulating current suppression for ground tied variable frequency to constant frequency converter system in aircraft
4
作者 Wei WEI Ming HUANG +2 位作者 Wenli YAO Weilin LI Xiaobin ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第11期386-397,共12页
This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400... This paper presents a solution to the circulating current fault of aircraft power supply.The DC-link type Variable Frequency to Constant Frequency(VFCF)converter system is the preferred scheme to feed the constant 400 Hz load in an aircraft with a variable frequency power supply.Due to the requirement of aircraft standards,both grounds of the rectification and inversion stage are tied to the metal frame of the aircraft.With such a tied ground,the DC bus voltage rises greatly,and a large circulating current appears in the casing as the ground,which leads to equipment failure and potential safety hazards.According to the existing methods of circulating current fault suppression,this paper analyzes the causes of the above faults and the harmonic components of circulating current and points out the limitations of the existing methods.Therefore,a Common-Mode(CM)choke-based method is proposed to provide a high impedance in the path of the CM circulating current.By doing so,the circulating current can be suppressed without the additional burden of the hardware and control algorithm,which is quite friendly for quality control of mass-production aircraft.Moreover,a simplified mathematic model of the VFCF converter system is derived to calculate the minimum inductance value reference of the CM choke,which saves the weight of passive devices to the greatest extent.Finally,simulation and experimental results are studied to verify the effectiveness of the proposed method. 展开更多
关键词 Aircraft power supply Circulating current Common mode choke Power supply circuits variable speed Constant frequency
原文传递
IMPROVEMENT IN WAVEFORM OF SWITCHING POINT-PRESET SPWM INVERTERS
5
作者 谢少军 裘卫红 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1995年第1期72-79,共8页
Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width mo... Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width modulation (SPWM) inverters with low harmonyic content in theory.The THD value would be increased by switching time delay of power devices and control circuit. A new control coecuit with delay time compensation is presented in this paper. With this control scheme, the output of the inverter could be basically identified with the theory given.Test results of experimental circuit verify that the control circuit presented in this paper is feasible. The THD of the inverter output voltage could be reduced to a certain extent by this method. 展开更多
关键词 INVERTERS pulse width modulation variable speed constant frequency (VSCF) total harmonic distortion switching-point-preset
在线阅读 下载PDF
"One-for-several" rotor VVVF Technique apply to water injection station
6
作者 Yanrong CHANG Shouhu WANG Ruxian HE 《International Journal of Technology Management》 2013年第3期38-41,共4页
In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displa... In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displacement and volume of injection allocation phase matching. But the technology in pump class load application speed range is limited, there is still a reflux valve control blind area," turn off undead" problem. " One-for-several" rotor frequency Technique in water injection station application, solved the control blind area problem, the full realization of the variable frequency close return voltage injection, at the same time, the successful implementation of the slip power efficient feedback. Stable water injection pressure of the system, and the electric energy is saved, satisfy the oilfield high efficiency, fine water needs, has a high application value. 展开更多
关键词 "One-for-several" rotor frequency variable frequency speed regulation Stable pressure water injection Energy saving
在线阅读 下载PDF
Two-stage Voltage Closed Loop Control Scheme for Hybrid Excited Synchronous Generator-matrix Converter Generation System 被引量:1
7
作者 SHI Mingming ZHOU Bo +1 位作者 WEI Jiadan MAO Yiran 《中国电机工程学报》 EI CSCD 北大核心 2012年第3期I0001-I0023,共23页
Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power el... Matrix Converter(MC),a direct AC-ACconverter which is capable of bidirectional powerflow,unity input power factor control and efficiencyimprovement.Thus,it is more suitable for integrationof motor machine and power electronics systems.This paper investigated a novel generationsystem,which is composed of hybrid excitedsynchronous generator(HESG)and matrix converter(MC),as shown in Fig.1.Owing to the voltage clampcircuit,this structure waived an external DC sourcecommonly used for the excitation for HESG.Thevoltage clamp circuit shared a DC bus with afull-bridge converter and the excitation winding ofHESG is directly connected to the output of thefull-bridge converter achieving a bidirectional currentflow. 展开更多
关键词 matrix converter hybrid excited synchronous generator variable speed constant frequency
原文传递
上一页 1 下一页 到第