期刊文献+
共找到3,253篇文章
< 1 2 163 >
每页显示 20 50 100
Combination of ionic liquid dispersive liquid-phase microextraction and high performance liquid chromatography for the determination of triazine herbicides in water samples 被引量:4
1
作者 Qing-Xiang Zhou Yuan-Yuan Gao 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第5期745-748,共4页
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such a... A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants. 展开更多
关键词 Temperature-controlled ionic liquid dispersive liquid-phase microextraction Ionic liquid Triazine herbicides High performance liquid chromatography
原文传递
Combination of hollow fiber-based liquid-phase microextraction with sweeping techniques in micellar electrokinetic chromatography for the determination of Strychnos alkaloids in human urine
2
作者 Xiao Huan Zang Cai Rui Li +3 位作者 Qiu Hua Wu Chun Wang Dan Dan Han Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第3期316-318,共3页
A new method for the enrichment of Strychnos alkaloids in biological samples via liquid-phase microextxaodon (LPME) based on porous polypropylene hollow fibers in combination with on-line sweeping in micellar electr... A new method for the enrichment of Strychnos alkaloids in biological samples via liquid-phase microextxaodon (LPME) based on porous polypropylene hollow fibers in combination with on-line sweeping in micellar electrokinodc chromatography was developed. The calibration curve was linear over the range of 20-200 ng mL^-1 for both strychnine and brucine in human urine sample. The detection limits (S/N = 3:1) for strychnine and brucine were 1 ng mL^-1 and 2 ng mL^-1, respectively. The LPME-sweeping method has been successfully applied to the analysis of strychnine and brucine in real urine samples. 展开更多
关键词 Hollow fiber-based liquid-phase microextraction SWEEPING MEKC Strychnos alkaloids URINE
暂未订购
Trace Determination of Tamoxifen in Biological Fluids Using Hollow Fiber Liquid-Phase Microextraction Followed by High-Performance Liquid Chromatography-Ultraviolet Detection
3
作者 Amir Kashtiaray Hadi Farahani +2 位作者 Sharareh Farhadi Bertrand Rochat Hamid Reza Sobhi 《American Journal of Analytical Chemistry》 2011年第4期429-436,共8页
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox... The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples. 展开更多
关键词 High-Performance Liquid Chromatography-Ultraviolet Detection HOLLOW Fiber liquid-phase microextraction Human URINE And Plasma Samples TAMOXIFEN
在线阅读 下载PDF
Determination of urinary 8-hydroxy-2′-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction 被引量:6
4
作者 Zhang, Shao Wen Zou, Cun Jie +4 位作者 Luo, Nan Weng, Qian Feng Cai, Ling Shuang Wu, Cai Ying Xing, Jun 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第1期85-88,共4页
Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been sy... Urinary 8-hydroxy-2 -deoxyguanosine(8-OHdG) is an excellent marker of oxidative DNA damage.In this study,employing guanosine as dummy template a novel molecularly imprinted(MIP) monolithic capillary column had been synthesized,and that was used as medium of in-tube solid phase microextraction(SPME).Coupled with capillary electrophoresis-electrochemical detection(CE-ECD),the system of extraction and detection of 8-OHdG in urinary sample had been developed.Because of its greater phase ratio combined with conv... 展开更多
关键词 Molecularly imprinted monolith In-tube solid phase microextraction 8-Hydroxy-2 -deoxyguanosine(8-OHdG) ELECTROPHORESIS Urine
在线阅读 下载PDF
Analysis of α, β, γ-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography—mass spectrometry 被引量:4
5
作者 SUNTong-hua FANGNeng-hu +2 位作者 ZHUNan-wen WANGYa-lin JIAJin-ping 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第6期945-949,共5页
A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorp... A fast and simple method for determination of α, β, γ-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 μg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, longer lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water. 展开更多
关键词 solid phase microextraction activated carbon fiber residue analysis α β γ-hexachlorocyclohexanes GC-MS
在线阅读 下载PDF
Enhancement of Sensitivity for Determination of Phenols in Environmental Water Samples by Single-drop Liquid Phase Microextraction Using Ionic Liquid prior to HPLC 被引量:5
6
作者 Qing Xiang ZHOU Jun Ping XIAO +1 位作者 Cun Ling YE Xin Ming WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1073-1076,共4页
A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the... A single-drop liquid phase micro-extraction procedure using 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) was demonstrated for the sensitive determination of four phenols in water samples. Under the optimized conditions, the linear range of proposed method was excellent in the range of 0.5-100 μg·L^-1, the reproducibility (RSD, n=6) were in the range 5.4%-8.9% and detection limits (S/N=3) were 0.3, 0.3, 0.5 and 0.5 μg·L^-1 for 2, 4-dichlorophenol, 2-naphthol, 2-nitrophenol and 4-chlorophenol, respectively. The experimental results indicated that the effect of complex matrices natural water samples could be resolved with addition of sodium ethylene diamine tetracetate (EDTA) into the samples. Excellent spiked recoveries were achieved for these four phenols ranged from 86.2%-114.9 %. All these facts demonstrated that the proposed method with merits of low cost, simplicity and easy operating would be a competitive alternative procedure for the determination of such compounds at trace level. 展开更多
关键词 1-Butyl-3-methylimidazolium hexafluorophosphate single-drop liquid phase microextraction phenols.
在线阅读 下载PDF
Determination of Aromatic Components of Rosa davurica Pall. by Headspace Solid Phase Microextraction Combined with GC-MS 被引量:6
7
作者 Yuan NIU Qiong XU +4 位作者 Jian ZHUANG Yude WANG Lilan DAI Dengfei LI Yalan ZHAO 《Medicinal Plant》 CAS 2018年第5期20-22,26,共4页
[Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) com... [Objectives] To determine the aromatic components of Rosa davurica Pall. [Methods] 42 kinds of aromatic components were identified from the flowers of R. davurica by headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS). The main compounds were alcohols( 54. 88%) and aldehydes( 19. 55%). [Results] The top five components with the highest relative content were phenylethyl alcohol( 12. 69%),geraniol( 9. 85%),citronellol( 8. 80%),nerol( 7. 84%) and 2-n-pentylfuran( 7. 45%). [Conclusions] Headspace solid phase microextraction( HS-SPME) combined with gas chromatography-mass spectrometry( GC-MS) can provide basis for further development and utilization of R. davurica. 展开更多
关键词 Rosa davurica Pall. HEADSPACE solid phase microextraction (HS-SPME) Gas chromatography-mass spectrometry (GC-MS) AROMATIC COMPONENTS
暂未订购
Dynamic microwave-assisted extraction combined with liquid phase microextraction based on the solidification of a floating drop for the analysis of organochlorine pesticides in grains followed by GC 被引量:10
8
作者 Guijie Li Xu Zhang +5 位作者 Tingting Liu Hongxiu Fan Hongcheng Liu Shangyu Li Dawei Wang Lan Ding 《Food Science and Human Wellness》 SCIE 2021年第3期375-382,共8页
A convenient,cost-effective and fast method using dynamic microwave-assisted extraction and liquid phase microextraction based on the solidification of a floating drop was proposed to analyze organochlorine pesticides... A convenient,cost-effective and fast method using dynamic microwave-assisted extraction and liquid phase microextraction based on the solidification of a floating drop was proposed to analyze organochlorine pesticides in grains including rice,maize and millet.Twelve samples can be processed simultaneously in the method.During the extraction process,10%acetonitrile-water solutions containing 110μL of n-hexadecane were used to extract organochlorine pesticides.Subsequently,1.0 g sodium chloride was placed in the extract,and then centrifuged and cooled.The n-hexadecane drops containing the analytes were solidifi ed and transferred for determination by gas chromatography-electron capture detector without any further filtration or cleaning process.Limits of detection for organochlorine pesticides were 0.97–1.01μg/kg and the RSDs were in the range of 2.6%–8.5%.The developed technology has succeeded in analyzing six real grains samples and the recoveries of the organochlorine pesticides were 72.2%–94.3%.Compared with the published extraction methods,the developed method was used to analyze organochlorine pesticides in grains,being more environmentally friendly,which is suitable for the daily determination of organochlorine pesticides. 展开更多
关键词 Dynamic microwave-assisted extraction Liquid phase microextraction Gas chromatography Organochlorine pesticides Grain
在线阅读 下载PDF
Solid phase microextraction chemical biopsy tool for monitoring of doxorubicin residue during in vivo lung chemo-perfusion 被引量:7
9
作者 Barbara Bojko Nikita Looby +11 位作者 Mariola Olkowicz Anna Roszkowska Bogumiła Kupcewicz Pedro Reck dos Santos Khaled Ramadan Shaf Keshavjee Thomas K.Waddell German Goomez-Rios Marcos Tascon Krzysztof Gorynski Marcelo Cypel Janusz Pawliszyn 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第1期37-47,共11页
Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires ca... Development of a novel in vivo lung perfusion(IVLP)procedure allows localized delivery of high-dose doxorubicin(DOX)for targeting residual micrometastatic disease in the lungs.However,DOX delivery via IVLP requires careful monitoring of drug level to ensure tissue concentrations of this agent remain in the therapeutic window.A small dimension nitinol wire coated with a sorbent of biocompatible morphology(Bio-SPME)has been clinically evaluated for in vivo lung tissue extraction and determination of DOX and its key metabolites.The in vivo Bio-SPME-IVLP experiments were performed on pig model over various(150 and 225 mg/m^(2))drug doses,and during human clinical trial.Two patients with metastatic osteosarcoma were treated with a single 5 and 7 μg/mL(respectively)dose of DOX during a 3-h IVLP.In both pig and human cases,DOX tissue levels presented similar trends during IVLP.Human lung tissue concentrations of drug ranged between 15 and 293 μg/g over the course of the IVLP procedure.In addition to DOX levels,Bio-SPME followed by liquid chromatography-mass spectrometry analysis generated 64 metabolic features during endogenous metabolite screening,providing information about lung status during drug administration.Real-time monitoring of DOX levels in the lungs can be performed effectively throughout the IVLP procedure by in vivo Bio-SPME chemical biopsy approach.Bio-SPME also extracted various endogenous molecules,thus providing a real-time snapshot of the physiology of the cells,which might assist in the tailoring of personalized treatment strategy. 展开更多
关键词 In vivo solid phase microextraction Metabolite profiling Spatial resolution Therapeutic drug monitoring Tissue analysis
暂未订购
Trace determination of hexabromocyclododecane diastereomers in water samples with temperature controlled ionic liquid dispersive liquid phase microextraction 被引量:3
10
作者 Ru Song Zhao Xia Wang Jin Peng Yuan Shan Shan Wang Chuan Ge Cheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2011年第1期97-100,共4页
A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been ... A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been developed for the enrichment and determination of three hexabromocyclododecane diastereomers (HBCDs) in water samples. Green solvent ionic liquid (IL) was used as extraction solvent instead of toxic organic solvents. This technique also avoided the usage of dispersive solvent. Some important parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. All the limits of detection for the three diastereomers were 0.1 ng/ mL. The linear range was obtained in the range of 1-100 ng/mL for the total amount of three HBCD diastereomers. It was satisfactory to analyze real environmental water samples with the recoveries ranging from 77.2% to 99.3%. The main advantage of the method is toxic organic solvent-free. 展开更多
关键词 HEXABROMOCYCLODODECANE Temperature controlled ionic liquid dispersive liquid phase microextraction Rapid resolution liquidchromatography-electrospray tandem mass spectrometry
原文传递
Hollow fiber-based liquid phase microextraction followed by analytical instrumental techniques for quantitative analysis of heavy metal ions and pharmaceuticals 被引量:3
11
作者 Wajid Ali Khan Muhammad Balal Arain +4 位作者 Yadollah Yamini Nasrullah Shah Tasneem Gul Kazi Stig Pedersen-Bjergaard Mohammad Tajik 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第2期109-122,共14页
Hollow-fiber liquid-phase microextraction(HF-LPME)and electromembrane extraction(EME)are miniaturized extraction techniques,and have been coupled with various analytical instruments for trace analysis of heavy metals,... Hollow-fiber liquid-phase microextraction(HF-LPME)and electromembrane extraction(EME)are miniaturized extraction techniques,and have been coupled with various analytical instruments for trace analysis of heavy metals,drugs and other organic compounds,in recent years.HF-LPME and EME provide high selectivity,efficient sample cleanup and enrichment,and reduce the consumption of organic sol-vents to a few micro-liters per sample.HF-LPME and EME are compatible with different analytical in-struments for chromatography,electrophoresis,atomic spectroscopy,mass spectrometry,and electrochemical detection.HF-LPME and EME have gained significant popularity during the recent years.This review focuses on hollow fiber based techniques(especially HF-LPME and EME)of heavy metals and pharmaceuticals(published 2017 to May 2019),and their combinations with atomic spectroscopy,UV-VIS spectrophotometry,high performance liquid chromatography,gas chromatography,capillary elec-trophoresis,and voltammetry. 展开更多
关键词 HOLLOW fiber liquid phase microextraction Electromembrane extraction HEAVY metals Pharmaceuticals INSTRUMENTAL TECHNIQUES
暂未订购
Fabrication and Growth Mechanism of Single-crystalline Rutile TiO_2 Nanowires by Liquid-phase Deposition Process in a Porous Alumina Template 被引量:4
12
作者 Abbas Sadeghzadeh Attar Zahra Hassani 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2015年第8期828-833,共6页
TiO2 nanowire arrays were successfully fabricated by liquid-phase deposition method using porous alumina templates. The obtained TiO2 nanowires were characterized using Raman spectroscopy, X-ray diffraction (XRD), s... TiO2 nanowire arrays were successfully fabricated by liquid-phase deposition method using porous alumina templates. The obtained TiO2 nanowires were characterized using Raman spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), field emission scanning electron microscopy (FE- SEM), transmission electron microscopy (TEM), and selected area electron diffraction (SAED) analysis. Results of electron microscopic observations indicated that the nanowires were smooth and uniform with a diameter of about 50-80 nm and several micrometers in length. SAED, Raman, and XRD mea- surements showed that TiO2 nanowires were single-crystalline with a pure rutile structure after heating at 800 ~C for 10 h. In this situation, the nanowire constituents grew preferentially along the 〈001〉 direction. Furthermore, the formation process and mechanistic study of the Ti02 nanowire arrays were proposed and discussed in detail. The nanowires are clearly produced by the deposition of TiO2 particles on the inner wall of the template nanochannels. 展开更多
关键词 TiO2 nanowire arrays Single crystal Rutile phase liquid-phase deposition process
原文传递
A novel fiber coating for solid phase microextraction and its application for the extraction of n-alkane from aqueous sample 被引量:1
13
作者 HUANG Min-jia JIANG Gui-bin ZHAO Zong-shan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期930-932,共3页
Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This elect... Base on the previous work in laboratory, a novel polyaniline doped with polydimethylsiloxane coating was developed on a stainless steel wire for solid phase microextraction(SPME) by electroplating method. This electroplating method not only has advantages of ease preparation and simple equipments required, but also increases the lifetime of the SPME fiber. The composite fiber(polyaniline/ polydimethylsiloxane(PANI/PDMS)) was evaluated by analyzing n-tridecane, n-tetradecane and n-pentadecane in aqueous sample. The new fiber coating showed comprehensive abilities to extract alkanes compounds. The relative standard deviations were found to be 6.8%-10.33%. 展开更多
关键词 solid phase microextraction stainless steel wires electroplating fiber preparation polyaniline/polydimethylsiloxane ALKANES
在线阅读 下载PDF
Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction 被引量:1
14
作者 Qing Xiang Zhou Guo Hong Xie Long Pang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第1期89-91,共3页
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such a... A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 展开更多
关键词 Liquid phase microextraction ATRAZINE High performance liquid chromatography Water samples
在线阅读 下载PDF
Porous covalent organic frameworks-improved solid phase microextraction ambient mass spectrometry for ultrasensitive analysis of tetrabromobisphenol-A analogs 被引量:2
15
作者 Wei Gao Min Li +5 位作者 Yun Fa Zongshan Zhao Yaqi Cai Xiangfeng Liang Yongliang Yu Guibin Jiang 《Chinese Chemical Letters》 SCIE CAS CSCD 2022年第8期3849-3852,共4页
Owing to frequent environmental monitoring of tetrabromobisphenol-A(TBBPA)analogs and their potential ecotoxicological effects on organisms,analysis of trace levels of TBBPA analogs with more non-polar and less water-... Owing to frequent environmental monitoring of tetrabromobisphenol-A(TBBPA)analogs and their potential ecotoxicological effects on organisms,analysis of trace levels of TBBPA analogs with more non-polar and less water-soluble characteristics is of great significance for studying their environmental behaviors and toxic effects.Herein,a fast and sensitive technique is developed for directly detecting aqueous TBBPA analogs,including TBBPA mono(allyl ether)(TBBPA-MAE),TBBPA mono(2,3-dibromopropyl ether)(TBBPAMDBPE),TBBPA mono(2-hydroxyethyl ether)(TBBPA-MHEE)and TBBPA mono(glycidyl ether)(TBBPAMGE),by combining solid phase microextraction(SPME)based on porous covalent organic frameworks(Porous-COFs)with constant flow desorption ionization-mass spectrometry(CFDI-MS).As chromatographic separation is replaced by constant flow desorption,each sample can be analyzed within 7 min.The hierarchical porous structures(microporous,mesoporous and macroporous)of COFs lead to the enhanced mass transfer and the easier accessibility of active sites to TBBPA analogs,so that the extraction efficiency is 2.3-3.6 times higher than pure microporous COFs,and far superior to commercial coatings.The detection limit and quantification limit of this method are 0.1-1 and 0.4-3.2 ng/L,respectively.Ultratrace levels of TBBPA analogs from 5.0 ng/L to 66 ng/L have been successfully detected in river and sea water samples,showing great potential for subsequent studies of their environmental behaviors and toxicological effects. 展开更多
关键词 Environmental analysis Covalent organic frameworks Solid phase microextraction Ambient mass spectrometry TBBPA analogs
原文传递
Comparison of Headspace Solid-Phase Microextraction with Simultaneous Steam Distillation Extraction for the Analysis of the Volatile Constituents in Chinese Apricot 被引量:20
16
作者 CHEN Mei-xia CHEN Xue-sen +4 位作者 WANG Xin-guo CI Zhi-juan LIU Xiao-li HE Tian-ming ZHANG Li-jie 《Agricultural Sciences in China》 CAS CSCD 2006年第11期879-884,共6页
Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction ... Volatile constituents in fully mature fruits of apricot (Prunus armeniaca L.) cultivar Xinshiji were extracted using headspace solid-phase microextraction (HS-SPME) and simultaneous steam distillation extraction (SSDE) and then analyzed using capillary gas chromatography and gas chromatography-mass spectrometry. A total of 70 components were identified by HSSPME, including 20 esters, 19 hydrocarbons, 5 alcohols, 5 ketones, 4 acids, 4 lactones, 3 aldehydes, and 10 miscellaneous components, with the esters being the dominant constituent. On the basis of the odor unit values, it is believed that the following compounds probably contributed to the fresh apricot odor: hexyl acetate, β-ionone, butyl acetate, (E)-2-hexenal, linalool, limonene, γ-decalactone, and hexanal. A total of 49 components were also detected by SSDE, including 13 hydrocarbons, 9 alcohols, 7 aldehydes, 9 esters, 4 ketones, 4 lactones, 2 acids, and 1 miscellaneous component, of which the monoterpene alcohols were the dominant constituents. It could be judged from the odor unit values that the following compounds were the major contributors to boiled apricot aroma: β-ionone, linalool, hexyl acetate, γ-dodecalactone, γ- decalactone, (E)-2-hexenal, hexanal, γ-octalactone, phenylacetaldehyde, butyl acetate, limonene, α-terpineol, and δ-decalactone. The results show that HS-SPME is a simple, rapid, and solvent-free method, which is an alternative to the classical SSDE. 展开更多
关键词 AROMA volatile constituents APRICOT solid-phase microextraction simultaneous distillation-extraction
在线阅读 下载PDF
Solid phase microextraction(SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases 被引量:1
17
作者 Underwood Susanne W. Jong Edmund C. +3 位作者 Luxbacher Kray D. Sarver Emily A. Ripepi Nino S. Mc Nair Harold M. 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期559-563,共5页
Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling... Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph (GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 ~m PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride (SF6) and perfluoromethylcyclohexane (PMCH) with adequate sensitivity. 展开更多
关键词 Solid phase microextraction Sulfur hexafluoride Perfluoromethylcyclohexane Tracer gas Mine ventilation Air sampling
在线阅读 下载PDF
Determination of Trace Amounts of Lead by Modified Graphite Furnace Atomic Absorption Spectrometry after Liquid Phase Microextraction with Pyrimidine-2-thiol 被引量:1
18
作者 Saeid Nazari 《American Journal of Analytical Chemistry》 2011年第7期757-767,共11页
The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lea... The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lead was extracted from a 2 ml of its aqueous sample in the pH = 5 as lead-Pyrimidine-2-thiol cationic complex into a 4 μl drop of 1,2 dichloroethane and ammonium tetraphenylborate as counter ion immersed in the solution. In the drop, the lead-Pyrimidine-2-thiol ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [W.Pd.Mg] (c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time, stirring rate and effect of salt were optimized. Under the optimum conditions, the enrichment factor and recovery were 525% and 94%, respectively. The calibration graph was linear in the range of 0.01 - 12 μg?L–1 with correlation coefficient of 0.9975 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0072 μg?L–1 and relative standard deviation (RSD) for ten replicate measurement of 0.1 μg?L–1 and 0.4 μg?L–1 lead was 4.5% and 3.8% respectively. The characteristic concentration was 0.0065 μg?L–1 equivalent to a characteristic mass of 26 fg. The results for determination of lead in reference materials, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method. 展开更多
关键词 LEAD Liquid phase microextraction PRECONCENTRATION Graphite Furnace Atomic Absorption Spectrometry
在线阅读 下载PDF
Preparation of polypyrrole/nanosilica composite for solid-phase microextraction of bisphenol and phthalates migrated from containers to eye drops and injection solutions 被引量:3
19
作者 Mehdi Ansari Dogaheh Mansoureh Behzadi 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2019年第3期185-192,共8页
This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized inf... This paper describes the electrodeposition of polyphosphate-doped polypyrrole/nanosilica nano-composite coating on steel wire for direct solid-phase microextraction of bisphenol A and five phthalates. We optimized influencing parameters on the extraction efficiency and morphology of the nanocomposite such as deposition potential, concentration of pyrrole and polyphosphate, deposition time and the nanosilica amount. Under the optimized conditions, characterization of the nanocomposite was inves-tigated by scanning electron microscopy and Fourier transform infra-red spectroscopy. Also, the factors related to the solid-phase microextraction method including desorption temperature and time, extrac-tion temperature and time, ionic strength and pH were studied in detail. Subsequently, the proposed method was validated by gas chromatography-mass spectrometry by thermal desorption and acceptable figures of merit were obtained. The linearity of the calibration curves was between 0.01 and 50 ng/mL with acceptable correlation coefficients (0.9956-0.9987) and limits of detection were in the range 0.002-0.01 ng/mL. Relative standard deviations in terms of intra-day and inter-day by five replicate analyses from aqueous solutions containing 0.1 ng/mL of target analytes were in the range 3.3%-5.4% and 5%-7.1%, respectively. Fiber-to-fiber reproducibilities were measured for three different fibers prepared in the same conditions and the results were between 7.3% and 9.8%. Also, extraction recoveries at two different concentrations were ≥96%. Finally, the suitability of the proposed method was demonstrated through its application to the analysis of some eye drops and injection solutions. 展开更多
关键词 SOLID-phase microextraction Gas chromatography-mass spectrometry Polyphosphate-doped POLYPYRROLE NANOSILICA PHTHALATES BisphenolA
暂未订购
Integration of GC-MS Based Non-Targeted Metabolic Profiling with Headspace Solid Phase Microextraction Enhances the Understanding of Volatile Differentiation in Tobacco Leaves from North Carolina, India and Brazil 被引量:3
20
作者 Dong-Ming Ma Saiprasad V. S. Gandra +1 位作者 Navin Sharma De-Yu Xie 《American Journal of Plant Sciences》 2012年第12期1759-1769,共11页
In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile com... In this report, gas chromatography-mass spectrometry (GC-MS) based non-targeted metabolomics is used to develop appropriate headspace solid phase microextractions (HS-SPME) to enhance the understanding of volatile complexity of flue-cured tobacco leaves. Non-targeted metabolic profiling of GC-MS shows that the extraction condition of HS-SPME at 100?C for 30 min provides a better metabolite profile than other extraction conditions tested. GC-MS and principal component analyses (PCA) show that among five types of fibers tested, 100 μm polydimethylsiloxane (PMDS), 65 μm polydimethylsiloxane/divinylbenzene (PMDS/DVB) and 75 μm carboxen/polydimethylsiloxane (CAR/ PMS) provide a better reproducible metabolite profile. Based on an appropriate PDMS extraction condition optimized, we use GC-MS analysis and PCA to compare metabolite profiles in flue-cured leaves of tobacco plants grown in North Carolina, India and Brazil, respectively. The resulting data of PCA show that the global metabolic profiles in North Carolina samples are separated from those in Brazil and India samples, two groups of which are characterized by a partially overlapped pattern. Several peaks that were differentially accumulated in samples were annotated to known metabolites by deconvolution analysis, such as norsolanadione, solavetivone and rishtin. Norsolanadione is detected only in Brazil samples. Solavetivone is detected in samples of India and Brazil but not in those of North Carolina. Rishtin is detected in samples of North Carolina and India but not in Brazil samples. These data indicate that not only can a non-targeted metabolic profiling approach enhance the understanding of volatile complexity, but also can identify marker volatile metabolites in tobacco leaves produced in different growth regions. 展开更多
关键词 TOBACCO HEADSPACE SOLID-phase microextraction Gas Chromatography Mass Spectrum VOLATILE Compounds
暂未订购
上一页 1 2 163 下一页 到第
使用帮助 返回顶部