期刊文献+
共找到38篇文章
< 1 2 >
每页显示 20 50 100
Effective electroelastic constants for three-phase confocal elliptical cylinder model in piezoelectric quasicrystal composites 被引量:6
1
作者 Yongbin WANG Junhong GUO 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2018年第6期797-812,共16页
A three-phase confocal elliptical cylinder model is proposed to analyze micromechanics of one-dimensional hexagonal piezoelectric quasicrystal (PQC) compos- ites. Exact solutions of the phonon, phason, and electric ... A three-phase confocal elliptical cylinder model is proposed to analyze micromechanics of one-dimensional hexagonal piezoelectric quasicrystal (PQC) compos- ites. Exact solutions of the phonon, phason, and electric fields are obtained by using the conformal mapping combined with the Laurent expansion technique when the model is subject to far-field anti-plane mechanical and in-plane electric loadings. The effective elec- troelastic constants of several different composites made up of PQC, quasicrystal (QC), and piezoelectric (PE) materials are predicted by the generalized self-consistent method. Numerical examples are conducted to show the effects of the volume fraction and the cross-sectional shape of inclusion (or fiber) on the effective electroelastic constants of these composites. Compared with other micromechanical methods, the generalized self- consistent and Mori-Tanaka methods can predict the effective electroelastic constants of the composites consistently. 展开更多
关键词 piezoelectric quasicrystal (PQC) three-phase elliptical cylinder model effective constant generalized self-consistent method
在线阅读 下载PDF
Testing for Nonlinearity in Dynamic Characteristics of Vertical Upward Oil-Gas-Water Three-phase Bubble and Slug Flows 被引量:1
2
作者 朱雷 金宁德 +2 位作者 高忠科 杜萌 王振亚 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第5期870-882,共13页
Based on the conductance fluctuation signals measured from vertical upward oil-gas-water three-phase flow experiment, time frequency representation and surrogate data method were used to investigate dynamical characte... Based on the conductance fluctuation signals measured from vertical upward oil-gas-water three-phase flow experiment, time frequency representation and surrogate data method were used to investigate dynamical characteristics of oil-in-water type bubble and slug flows. The results indicate that oil-in-water type bubble flow will turn to deterministic motion with the increase of oil phase fraction f o and superficial gas velocity U sg under fixed flowrate of oil-water mixture Q mix . The dynamics of oil-in-water type slug flow becomes more complex with the increase of U sg under fixed flowrate of oil-water mixture. The change of f o leads to irregular influence on the dynamics of slug flow. These interesting findings suggest that the surrogate data method can be a faithful tool for characterizing dynamic characteristics of oil-in-water type bubble and slug flows. 展开更多
关键词 oil-gas-water three-phase flow conductaJace fluctuating signals time-frequency representation surrogate data method
在线阅读 下载PDF
Automatic measurement of three-phase contact angles in pore throats based on digital images 被引量:1
3
作者 ZANG Chuanzhen WANG Lida +3 位作者 ZHOU Kaihu YU Fuwei JIANG Hanqiao LI Junjian 《Petroleum Exploration and Development》 SCIE 2023年第2期442-449,共8页
With the help of digital image processing technology, an automatic measurement method for the three-phase contact angles in the pore throats of the microfluidic model was established using the microfluidic water flood... With the help of digital image processing technology, an automatic measurement method for the three-phase contact angles in the pore throats of the microfluidic model was established using the microfluidic water flooding experiment videos as the data source. The results of the new method were verified through comparing with the manual measurement data.On this basis, the dynamic changes of the three-phase contact angles under flow conditions were clarified by the contact angles probability density curve and mean value change curve. The results show that, for water-wetting rocks, the mean value of the contact angles is acute angle during the early stage of the water flooding process, and it increases with the displacement time and becomes obtuse angle in the middle-late stage of displacement as the dominant force of oil phase gradually changes from viscous force to capillary force. The droplet flow in the remaining oil occurs in the central part of the pore throats, without three-phase contact angle. The contact angles for the porous flow and the columnar flow change slightly during the displacement and present as obtuse angles in view of mean values, which makes the remaining oil poorly movable and thus hard to be recovered. The mean value of the contact angle for the cluster flow tends to increase in the flooding process, which makes the remaining oil more difficult to be recovered. The contact angles for the membrane flow are mainly obtuse angles and reach the highest mean value in the late stage of displacement, which makes the remaining oil most difficult to be recovered. After displacement, the remaining oils under different flow regimes are just subjected to capillary force, with obtuse contact angles, and the wettability of the pore throat walls in the microfluidic model tends to be oil-wet under the action of crude oil. 展开更多
关键词 microfluidic model water flooding experiment digital image processing three-phase contact angle measure-ment method flow regime of the remaining oil
在线阅读 下载PDF
Three-Phase Optimal Power Flow for Study of PV Plant Distributed Impact on Distribution Systems
4
作者 Malinwo E. Ayikpa Katia C. de Almeida Guilherme C. Danielski 《Journal of Electrical Engineering》 2017年第1期47-56,共10页
This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or abs... This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation. 展开更多
关键词 three-phase optimal power flow photovoltaic generation unbalance voltage LOSS primal-dual interior point method.
在线阅读 下载PDF
Prediction of Core Losses of Three-Phase Distribution Transformer
5
作者 Mihail Digalovski Krste Najdenkoski Goran Rafajlovski 《Journal of Energy and Power Engineering》 2013年第12期2347-2353,共7页
Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additi... Transformers are normally designed and built for use at rated frequency and sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in transformer parts. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To prevent these problems, the rated capacity of transformer which supplies harmonic loads must be reduced. In this work, a typical 50 kVA three-phase distribution transformer with real practical parameters is taken under non-linear loads generated due to domestic loads. The core losses is evaluated using the three dimensional model of the transformer developed in FEM (finite element method) program based on valid model of transformer under high harmonic conditions. And finally a relation associated with core losses and amplitude of high harmonic order are reviewed & analyzed and then a comparison is being carried out on the results obtained by different excitation current in transformer windings. 展开更多
关键词 Core losses three-phase transformer HARMONIC 3D model finite element method magnetic flux distribution.
在线阅读 下载PDF
Analysis on Circulating Current and Split Capacitor Voltage Balance for Modular Multilevel Converter Based Three-phase Four-wire Split Capacitor DSTATCOM 被引量:2
6
作者 Lei Lin Jialu He Chen Xu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第3期657-667,共11页
We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to ... We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to the zero-sequence current compensation,the circulating current char-acteristics of 3P4W MMC-DSTATCOM are different from conventional MMCs.Moreover,the distinct working principle of IMMC would affect the features of split capacitor voltage.The decoupled positive-,negative-and zero-sequence second-order and DC components of the circulating current are deduced explicitly.Two proportional-integral controllers with dual dq transformation are employed to suppress the positive-and negative-sequence components of second-order circulating current,while quasi proportional-resonance controller is designed to eliminate the zero-sequence component.Besides,the phenomenon of the unbalanced split capacitor voltages is revealed,and fast-tracking balancing method by controlling zero-sequence current flowing through the split capacitors is provided.Digital simulation results verify the accuracy of the analysis and the feasibility of the suppression methods. 展开更多
关键词 Circulating current modular multilevel converter(MMC) distribution static synchronous compensator(DSTATCOM) split capacitor three-phase four-wire(3P4W)
原文传递
Coordinated Control of Parallel Three-phase Four-wire Converters in Autonomous AC Microgrids
7
作者 Rui Liu Li Guo Xialin Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第5期2065-2078,共14页
The coordinated control of parallel three-phase fourwire converters in autonomous AC microgrids is investigated in this paper.First,based on droop control,virtual impedance is inserted in positive-,negative-and zero-s... The coordinated control of parallel three-phase fourwire converters in autonomous AC microgrids is investigated in this paper.First,based on droop control,virtual impedance is inserted in positive-,negative-and zero-sequences to enhance system damping and imbalance power sharing.Then,to facilitate virtual impedance design,small signal models of the three-sequence equivalent circuits are established respectively.Corresponding indexes are proposed to comprehensively evaluate the impact of sequence virtual impedance on current sharing accuracy,voltage quality at the point of common coupling(PCC)and system stability.In addition,constraint of DClink voltage is also considered to avoid over modulation when subjected to unbalanced loads.Furthermore,to address the PCC voltage degradation resulting from virtual impedance,a voltage imbalance compensation method,based on low-bandwidth communication,is proposed.Finally,simulation and experimental results are provided to verify the correctness of the theory model,indicating that the proposed method can achieve PCC voltage restoration while guaranteeing the current sharing accuracy with desirable dynamics. 展开更多
关键词 AC microgrids sequence virtual impedance three-phase four-wire(3P4W)converter voltage imbalance compensation
原文传递
FBD法在三相四线制系统电流实时检测中应用 被引量:21
8
作者 康静 郑建勇 +1 位作者 曾伟 袁涛 《电力自动化设备》 EI CSCD 北大核心 2006年第8期36-39,共4页
为了快速、有效地检测出三相四线制电力系统中的谐波、负序和零序电流,提出了一种基于FBD法的电流实时检测方法。该方法的关键是利用参考电压进行投影变换,利用参考电压和三相电流求得电路等效电导,再利用等效电导求得指令电流,从而使... 为了快速、有效地检测出三相四线制电力系统中的谐波、负序和零序电流,提出了一种基于FBD法的电流实时检测方法。该方法的关键是利用参考电压进行投影变换,利用参考电压和三相电流求得电路等效电导,再利用等效电导求得指令电流,从而使检出电流与参考电压波形相位保持一致,可以在系统电压畸变的情况下检测出三相电流的基波正序有功、无功电流分量,不对称电流以及谐波电流分量,拓展了FBD法的应用范围。与基于瞬时无功功率理论的电流检测方法相比,该方法没有复杂的Park变换和dq变换,可以更加快速有效地进行电流实时检测。仿真结果表明了该电流检测方法的正确性和有效性。 展开更多
关键词 有源滤波器 电流检测 三相四线 FBD法
在线阅读 下载PDF
三相四线制系统谐波检测p-q-0法的研究 被引量:11
9
作者 张金斗 张勇 程新功 《继电器》 CSCD 北大核心 2006年第20期53-56,共4页
以瞬时无功功率理论为基础,介绍了针对三线四线制系统谐波电流检测和无功补偿所提出的p-q-0法,分析了瞬时无功功率理论在三线四线制电力系统下的物理意义,并给出了该系统下谐波和无功电流的检测控制算法原理图,详细讨论了三相负载不平... 以瞬时无功功率理论为基础,介绍了针对三线四线制系统谐波电流检测和无功补偿所提出的p-q-0法,分析了瞬时无功功率理论在三线四线制电力系统下的物理意义,并给出了该系统下谐波和无功电流的检测控制算法原理图,详细讨论了三相负载不平衡时的补偿效果。通过理论分析,在M atlab环境下对三相不平衡负载电路仿真证明,当电网电流发生严重畸变时,p-q-0法不仅能准确、实时地消除三相四线制系统中的谐波电流,对中线电流抑制及无功功率补偿也有较好的效果,并且补偿后的电源瞬时三相功率为定值。 展开更多
关键词 瞬时功率 P-q-0法 三相四线制 谐波抑制 无功补偿
在线阅读 下载PDF
改进的FBD法在电流实时检测中应用 被引量:1
10
作者 康静 郑建勇 +2 位作者 饶莹 曾伟 袁涛 《电力自动化设备》 EI CSCD 北大核心 2007年第5期77-80,共4页
为了使有源滤波器快速有效地检测出三相四线制电力系统中的谐波和无功电流,提出了一种基于FBD(Fryze-Buchholz-Dpenbrock)法的改进的电流检测方法。该方法利用抽样降低系统计算量,并用一个陷波滤波器和一个高截止频率的低通滤波器串联... 为了使有源滤波器快速有效地检测出三相四线制电力系统中的谐波和无功电流,提出了一种基于FBD(Fryze-Buchholz-Dpenbrock)法的改进的电流检测方法。该方法利用抽样降低系统计算量,并用一个陷波滤波器和一个高截止频率的低通滤波器串联代替一个低截止频率的低通滤波器提取直流分量,提高了检测方法的实时性。该方法可以在系统电压畸变的情况下检测出三相电流的基波正序有功电流分量、基波正序无功电流分量、不对称电流及谐波电流分量。Matlab仿真结果表明了该方法的正确性和有效性。 展开更多
关键词 电流检测 三相四线 FBD法 抽样
在线阅读 下载PDF
基于改进FBD法的谐波电流检测研究 被引量:8
11
作者 司为国 丁祖军 李明 《电力系统保护与控制》 EI CSCD 北大核心 2009年第15期83-86,90,共5页
对谐波电流快速检测和跟踪的能力是有源电力滤波器补偿性能好坏的关键,为了能快速有效的检测出三相四线制系统中的谐波电流,本文在介绍传统FBD法的理论原理的基础上提出了一种改进的FBD法。它是将传统的FBD法经过一次线性变换,减少了其... 对谐波电流快速检测和跟踪的能力是有源电力滤波器补偿性能好坏的关键,为了能快速有效的检测出三相四线制系统中的谐波电流,本文在介绍传统FBD法的理论原理的基础上提出了一种改进的FBD法。它是将传统的FBD法经过一次线性变换,减少了其间的矩阵运算。该方法不受系统电压畸变的影响,可以明显减少原方法的计算量。理论分析和仿真以及实验结果证实了该方法的正确性和优越性。 展开更多
关键词 有源电力滤波器 谐波电流 检测 FBD法 三相四线制
在线阅读 下载PDF
三电平中点箝位整流器系统建模及基于李亚普诺夫直接法的控制方法研究 被引量:15
12
作者 孟永庆 苏彦民 刘正 《中国电机工程学报》 EI CSCD 北大核心 2005年第24期79-84,共6页
该文首先建立了基于开关函数的三相四线三电平中点箝位(NPC)电压型整流器的数学模型,分析了它的工作原理。并在Lyapunov稳定性理论的基础上,提出了一种新的三相四线三电平中点箝位PWM整流器非线性控制方法。该方法具有大范围渐进稳定,... 该文首先建立了基于开关函数的三相四线三电平中点箝位(NPC)电压型整流器的数学模型,分析了它的工作原理。并在Lyapunov稳定性理论的基础上,提出了一种新的三相四线三电平中点箝位PWM整流器非线性控制方法。该方法具有大范围渐进稳定,动态响应快的优点,并且通过设计新的三电平PWM调制方法,有效地解决了由现有三电平SPWM调制方法引入的直流母线中点电位存在三次波动的问题。系统仿真验证了该数学模型的正确性,以及基于Lyapunov直接法设计的非线性控制器的有效性。 展开更多
关键词 电力电子 三相四线三电平中点箝位整流器 数学模型 李亚普诺夫直接法 三电平脉宽调制
在线阅读 下载PDF
三相四线制系统谐波检测的p-q-r法 被引量:9
13
作者 宫鑫 蒋云峰 +1 位作者 张蔷 钟文辉 《电力自动化设备》 EI CSCD 北大核心 2005年第5期5-9,共5页
介绍了针对三相四线制系统谐波检测所提出的p-q-r法,详细讨论了p-g-r法对中线电流的抑制效果。针对电网电压畸变时补偿不完全的情况,提出采用前置滤波的方法,对采样的畸变电网电压信号进行滤波,去除谐波成分,保留基波成分。仿真结果表明... 介绍了针对三相四线制系统谐波检测所提出的p-q-r法,详细讨论了p-g-r法对中线电流的抑制效果。针对电网电压畸变时补偿不完全的情况,提出采用前置滤波的方法,对采样的畸变电网电压信号进行滤波,去除谐波成分,保留基波成分。仿真结果表明,采用该方法能够完全补偿电流谐波分量,消除电压畸变对结果的影响。 展开更多
关键词 P—q—r法 谐波检测 三相四线
在线阅读 下载PDF
三相四线制任意次谐波电流的无锁相环i_p-i_q检测新方法 被引量:10
14
作者 周林 张凤 +1 位作者 栗秋华 徐明 《继电器》 CSCD 北大核心 2006年第20期57-62,共6页
电力有源滤波器是补偿电力系统谐波及无功功率的重要装置,其关键的环节是实时准确地检测出谐波电流。介绍了ip-iq法的基本原理,在此基础上提出了一种适用于三相四线制系统的任意次谐波电流的无锁相环的检测新方法,该方法可以实现对三相... 电力有源滤波器是补偿电力系统谐波及无功功率的重要装置,其关键的环节是实时准确地检测出谐波电流。介绍了ip-iq法的基本原理,在此基础上提出了一种适用于三相四线制系统的任意次谐波电流的无锁相环的检测新方法,该方法可以实现对三相四线制不对称系统任意次谐波的正序、负序分量和零序分量的检测,最后将检测得到的正序、负序和零序相加就可以得到任意次谐波电流,理论分析和仿真结果都证实了本文所提出的新方法的准确性。 展开更多
关键词 三相四线制 任意次谐波电流检测 IP-IQ法 锁相环
在线阅读 下载PDF
100kVA三相四线有源电力滤波器的研制 被引量:6
15
作者 胡楷 潘孟春 于晶荣 《电工电能新技术》 CSCD 北大核心 2010年第1期30-34,共5页
三相四线配电网的谐波电流、三相不平衡和中性线电流过大问题比较普遍,三相四线SAPF是解决这些问题的理想方案。基于改进的FBD法的三相四线SAPF指令电流检测算法,能够将负载电流分解成基波各相序和单次谐波电流。应用该算法设计并实现... 三相四线配电网的谐波电流、三相不平衡和中性线电流过大问题比较普遍,三相四线SAPF是解决这些问题的理想方案。基于改进的FBD法的三相四线SAPF指令电流检测算法,能够将负载电流分解成基波各相序和单次谐波电流。应用该算法设计并实现了基于4桥臂主电路结构,容量为100kVA(输出电流150A)的SAPF样机,搭建了大容量实验环境,对该装置性能进行了实验验证并给出了结果。实验结果证明装置原理的可行性,对谐波电流、负序电流和零序电流补偿效果非常明显。 展开更多
关键词 三相四线 并联有源电力滤波器 FBD法 四桥臂主电路
在线阅读 下载PDF
p-q-r法与FBD法在三相四线制系统谐波电流检测中的对比 被引量:9
16
作者 陈娟 郑建勇 +3 位作者 丁祖军 曾伟 康静 袁涛 《电力自动化设备》 EI CSCD 北大核心 2007年第11期30-33,共4页
谐波电流检测是使用并联有源滤波器解决电网谐波污染的关键环节。对当今流行的三相四线制系统中谐波电流检测方法:p-q-r法、FBD法进行了深入分析。就系统电压对称和发生畸变2种情况,讨论了各自在谐波电流检测准确性、消除中线电流有效... 谐波电流检测是使用并联有源滤波器解决电网谐波污染的关键环节。对当今流行的三相四线制系统中谐波电流检测方法:p-q-r法、FBD法进行了深入分析。就系统电压对称和发生畸变2种情况,讨论了各自在谐波电流检测准确性、消除中线电流有效性、计算量、实时性等方面的检测性能,最后采用PSCAD/EMTDC仿真软件加以验证。结果表明,2种检测方法在准确性方面基本相同,FBD法电路简单,实时性较强;而p-q-r法能够独立消除中线电流,补偿灵活性好。 展开更多
关键词 三相四线制 谐波检测 电压畸变 p—q—r法 FBD法
在线阅读 下载PDF
三相四线制系统中基于等功率法的谐波检测 被引量:3
17
作者 梅军 沈亚飞 +2 位作者 郑建勇 曾伟 康静 《电力自动化设备》 EI CSCD 北大核心 2008年第2期49-53,共5页
有源电力滤波器(APF)补偿性能的好坏很大程度上取决于系统的谐波检测算法。介绍了三相四线制系统中的3种谐波检测法,即以瞬时无功功率理论为基础的d-q法、有功分离法和基于功率平衡的等功率法,重点阐述了等功率法。在系统电压畸变和无... 有源电力滤波器(APF)补偿性能的好坏很大程度上取决于系统的谐波检测算法。介绍了三相四线制系统中的3种谐波检测法,即以瞬时无功功率理论为基础的d-q法、有功分离法和基于功率平衡的等功率法,重点阐述了等功率法。在系统电压畸变和无畸变、负荷对称和不对称4种组合情况下利用PSCAD/EMTDC软件对系统的谐波检测进行仿真,在此基础上对3种检测法在补偿效果、实时性等方面作详细比较,分析各自特性。比较可知,等功率法不需要大量的计算,程序设计简单,且在补偿效果、实时性、直流侧电压利用率方面均取得其他2种方法难以比拟的效果,且易于硬件实现。实验结果表明,等功率法实用价值高。 展开更多
关键词 三相四线制 谐波检测 电压畸变 负荷不对称 等功率法
在线阅读 下载PDF
三相四线制电路中两功率表法计量误差分析 被引量:1
18
作者 查六一 邵建龙 周玉岩 《电力系统及其自动化学报》 CSCD 北大核心 2010年第5期76-79,共4页
由于两功率表法不能测量三相四线制电路中的零序功率,采用此法将少计量功率,这早已为许多从事电量测试和计量的人员所认识。但在实际测量中,有可能比实际功率多计量,也可能比实际功率少计量。文中以火铺火电厂的110 kV升压变压器为例,... 由于两功率表法不能测量三相四线制电路中的零序功率,采用此法将少计量功率,这早已为许多从事电量测试和计量的人员所认识。但在实际测量中,有可能比实际功率多计量,也可能比实际功率少计量。文中以火铺火电厂的110 kV升压变压器为例,通过现场实测数据,并对测量的数据进行分析,判断正负测量误差。通过分析该测量方式带来的测量误差来规范测量回路,减小关口电能表的测量误差,对电力企业、电力设计单位、施工单位都有着极为重要的意义。 展开更多
关键词 三相四线制 两功率表法 零序有功功率 正负测量误差 电能计量
在线阅读 下载PDF
三相四线制电路中采用两功率表法计量引起的计量误差分析 被引量:2
19
作者 查六一 邵建龙 周玉岩 《电力学报》 2010年第1期40-43,共4页
由于两功率表法不能测量三相四线制电路中的零序功率,采用此法将少计量功率,这早已为许多从事电量测试和计量的人员所认识。但在实际测量中,在三相四线制电路中采用两功率表法计量,有可能比实际功率多计量,也可能比实际功率少计量。以... 由于两功率表法不能测量三相四线制电路中的零序功率,采用此法将少计量功率,这早已为许多从事电量测试和计量的人员所认识。但在实际测量中,在三相四线制电路中采用两功率表法计量,有可能比实际功率多计量,也可能比实际功率少计量。以火铺火电厂的110 kV升压变压器为例,通过分析该测量方式带来的测量误差来规范测量回路,减小关口电能表的测量误差,对电力企业、电力设计单位、施工单位都有着极为重要的意义。 展开更多
关键词 三相四线制 两功率表法 正负测量误差 电能计量
在线阅读 下载PDF
三相四线电能表失压退补电量的误差研究 被引量:2
20
作者 邢晓敏 孙成 +2 位作者 陈劲游 商国敬 朱敏珊 《东北电力大学学报》 2018年第4期1-7,共7页
为了研究"电压替代法"在三相电网不对称时退补电量的误差范围,采用"对称分量法"对"电压替代法"退补电量的更正功率误差进行了分析计算,导出三相四线电能表失压退补电量的更正功率在电网三相电压、电流不... 为了研究"电压替代法"在三相电网不对称时退补电量的误差范围,采用"对称分量法"对"电压替代法"退补电量的更正功率误差进行了分析计算,导出三相四线电能表失压退补电量的更正功率在电网三相电压、电流不平衡状态下的误差表达式.根据误差表达式分析实际运行的功率因数及三相电压、电流不平衡度在一定范围变化时更正电量误差变化情况,并计算在电网相关约束条件下的误差、样机实测不平衡度的误差及某实际电网95%的三相电压幅值不平衡时的误差,结果显示其误差小于±3%.最后比较了C相电流取不同电流时,"电压替代法"和"更正系数法"的更正功率的计算误差,说明在三相不平衡负荷下"电压替代法"计算的退补电量误差远小于"更正系数法"的误差,得到的结果验证了该方法的可行性和实用性. 展开更多
关键词 电压替代法 对称分量法 三相四线电能表 失压退补电量 三相不平衡
在线阅读 下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部