BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are ne...BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size.展开更多
Characterizing the complex two-phase hydrodynamics in structured packed columns requires a power- ful modeling tool. The traditional two-dimensional model exhibits limitations when one attempts to model the de- tailed...Characterizing the complex two-phase hydrodynamics in structured packed columns requires a power- ful modeling tool. The traditional two-dimensional model exhibits limitations when one attempts to model the de- tailed two-phase flow inside the columns. The present paper presents a three-dimensional computational fluid dy- namics (CFD) model to simulate the two-phase flow in a representative unit of the column. The unit consists of an CFD calculations on column packed with Flexipak 1Y were implemented within the volume of fluid (VOF) mathe- matical framework. The CFD model was validated by comparing the calculated thickness of liquid film with the available experimental data. Special attention was given to quantitative analysis of the effects of gravity on the hy- drodynamics. Fluctuations in the liquid mass flow rate and the calculated pressure drop loss were found to be quali- tatively in agreement with the experimental observations.展开更多
A modeling tool for simulating three-dimensional land frequency-domain controlled-source electromagnetic surveys,based on a finite-element discretization of the Helmholtz equation for the electric fields,has been deve...A modeling tool for simulating three-dimensional land frequency-domain controlled-source electromagnetic surveys,based on a finite-element discretization of the Helmholtz equation for the electric fields,has been developed.The main difference between our modeling method and those previous works is edge finite-element approach applied to solving the three-dimensional land frequency-domain electromagnetic responses generated by horizontal electric dipole source.Firstly,the edge finite-element equation is formulated through the Galerkin method based on Helmholtz equation of the electric fields.Secondly,in order to check the validity of the modeling code,the numerical results are compared with the analytical solutions for a homogeneous half-space model.Finally,other three models are simulated with three-dimensional electromagnetic responses.The results indicate that the method can be applied for solving three-dimensional electromagnetic responses.The algorithm has been demonstrated,which can be effective to modeling the complex geo-electrical structures.This efficient algorithm will help to study the distribution laws of3-D land frequency-domain controlled-source electromagnetic responses and to setup basis for research of three-dimensional inversion.展开更多
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to...Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results.展开更多
Objective To evaluate the effectiveness of three-dimensional computed tomography (3D-CT) guided radiofi'equency trigeminal rhizotomy (RF-TR) in treatment of idiopathic trigeminal neuralgia (1TN). Methods From ...Objective To evaluate the effectiveness of three-dimensional computed tomography (3D-CT) guided radiofi'equency trigeminal rhizotomy (RF-TR) in treatment of idiopathic trigeminal neuralgia (1TN). Methods From 1999 to 2001, 18 patients with ITN were treated with percutaneous controlled RF-TR. Intraoperative 3D-CT scanning was performed to guide the trajectory of the puncture. After correction of the needle tip according to the CT scans and stimulation effects, 2 to 5 lesions were made for a duration of 60-90 seconds at a temperature of 60℃ to 75℃ depending on the pain distribution and the age of patient. The needles located in foramen ovale. Pain alleviated immediately with no serious complication in all patients. The patients were followed up for an average of 31.5 months (range 24-41 months). Acute pain relief was experienced by 17 patients after the procedure, reaching an initial success rate of 94.4%. Early (〈 6 months) pain recurrence was observed in 2 patients (11.1%), whereas late (〉 6 months) recurrence was reported in 3 patients (16.7%). Thirteen patients had complete pain control, with no need for medication thereafter. Five cases experienced partial pain relief, but required medication at a lower dose than in the preoperative period. Conclusion 3D-CT foramen ovale locations can raise the successful rate of puncture, enhance the safety, and reduce the incidence rate of complication.展开更多
BACKGROUND : Digital subtraction angiography (DSA) is always regarded as the golden standard for diagnosis of intracranial aneurysm; however, the procedure is complex, traumatic, expensive and easy to induce vascul...BACKGROUND : Digital subtraction angiography (DSA) is always regarded as the golden standard for diagnosis of intracranial aneurysm; however, the procedure is complex, traumatic, expensive and easy to induce vascular complication. Three-dimensional computed tomography angiography (3D-CTA) can make up deficiencies of DSA; therefore, it is used in clinical therapy wider and wider. OBJECTIVE : To evaluate the clinical effect of 3D-CTA on disruption and hemorrhage of intracranial aneurysm pre- and post-operation and compare with the effect of DSA. DESIGN : Auto-control contrast observation SETTING : Department of Neurosurgery, Shengjing Hospital of China Medical University PARTICIPANTS : A number of 106 patients with disruption and hemorrhage of intracranial aneurysm were selected from the Department of Neurosurgery, Shengjing Hospital of China Medical University from January 2003 to April 2006. All patients were diagnosed with cranial operation and consent. There were 47 males and 59 females aged from 3-76 years with the mean age of (47±13) years. Among them, 82 patients had extensive subarachnoid hemorrhage (SAH), 7 had hemorrhage at longitudinal fissure, and 17 had hemorrhage at ambiens cistema and lateral fissure. Moreover, intraventricular hematocele was accompanied on 13 patients and hematom on 9 patients. METHODS: (1) 3D-CTA examination: Siemens SOMATOM Sensation 64 CT was used in this study. The thickness was 1 mm and interval of reconstruction was 0.8 mm. Localizing section was plainly scanned as the standard of canthus line. Scan ranged from 30 mm below sella to 50 mm above sella. Non-ion contrast medium of Omnipaque 350 (concentration of iodine was 350 g/L) was inserted into anterior vein of elbow with 18G trochar retained with high-pressured injectoc pum. The speed was 4.5 mL/s and the total volume was 80-100 mL with the means of 90 mL. Scan started at 10-20 s after injection of contrast medium. Original image was dealt with Leonardo workstation and retreated with Syngo software. Volume rendering and maximum intensity projection were used to reconstructed images, (2) All 106 patients suffered from occlusion of aneurysm clamp. Before operation, 3D-CTA was undertaken and DSA was followed. After operation, patients were rechecked with 3D-CTA. MAIN OUTCOME MEASURES: Comparisons between 3D-CTA and DSA. RESULTS : All 106 patients were involved in the final analysis. (1) Examination of 3D-CTA and DSA: Among 118 patients with aneurysm, 110 were checked with 3D-CTA and the detected rate was 93.2% (110/118). Among other 8 cases, 3 were negative and checked again with DSA; 1 had pericallosal aneurysm, 1 ophthalmic aneurysm, and 1 anterior choroidal artery of aneurysm. 3D-CTA results of other 5 cases were suspicious, and then, they were regarded as having aneurysm with DSA. Before operation, correlation among site, body, neck of aneurysm and peripheral anatomic structure were shown sufficiently. After operation, 82 patients were rechecked with 3D-CTA, which was complete occlusion, precise, unobvious constriction, emphraxis or remains as compared with 3D-CTA those pre-operation. (2) Characteristics of 3D-CTA: With multiple vessels and angles, 3D-CTA observed the relationship between aneurysm neck and carried artery and showed thrombosis in cavity of aneurysm, calcification of aneurysm wall and peripheral structure of vessel at the same time. However, DSA could not detect the reactions mentioned above. It could delete image of cranium, simulate image of operative route, eliminate artifact induced by metal, but not distinguish blood stream direction. Meanwhile, posterior communicating artery was always poor during circle of Willis artery showing. CONCLUSION: (1) 3D-CTA is characterized by simple operation and non-invasive showing vascular stereo structure and correlation. Therefore, it is significant for diagnosis and designing plan of operative approach and focal location pre-operation and evaluating effect post-operation. (2) 3D-CTA does not completely replace DSA on the diagnosis of intracranial aneurysm.展开更多
BACKGROUND Situs inversus totalis(SIT)is a rare congenital condition that is characterized by a complete mirror image of the typical arrangement of the thoracic and abdominal viscera.Performing thoracoscopic segmentec...BACKGROUND Situs inversus totalis(SIT)is a rare congenital condition that is characterized by a complete mirror image of the typical arrangement of the thoracic and abdominal viscera.Performing thoracoscopic segmentectomy for a patient with lung cancer and SIT is an extremely skilled and challenging surgical procedure.CASE SUMMARY A 41-year old woman with a medical history of dextrocardia since childhood was admitted to our hospital with a mixed ground-glass opacity(mGGO)in her left lung field,discovered by computed tomography during her health checkup.In order to facilitate surgical orientation,three-dimensional computed tomography bronchography and angiography(3D-CTBA)was preoperatively carried out.The result of 3D-CTBA was consistent with the diagnosis of SIT and an mGGO in the posterior segment of the left upper lobe(LS2).Surgery was conducted in accordance with preoperative 3D-CTBA and designed surgical procedure,combined with intraoperative navigation.Final pathological examination revealed in situ adenocarcinoma.The patient’s postoperative condition was uneventful and no complications were observed.CONCLUSION We present the first case of lung cancer in a patient with SIT who successfully underwent thoracoscopic segmentectomy assisted by 3D-CTBA.This is a new technique that covers precise confirmation and dissection of targeted structures and intersegmental demarcation,and can help achieve a meticulous anatomical segmentectomy.展开更多
BACKGROUND Posterior malleolar fractures have been reported to occur in<40%of ankle fractures.AIM To reveal the recurrent patterns and characteristics of posterior malleolar fractures by creating fracture maps of t...BACKGROUND Posterior malleolar fractures have been reported to occur in<40%of ankle fractures.AIM To reveal the recurrent patterns and characteristics of posterior malleolar fractures by creating fracture maps of the posterior malleolar fractures through the use of computed tomography mapping.METHODS A consecutive series of posterior malleolar fractures was used to create threedimensional reconstruction images,which were oriented and superimposed to fit an ankle model template by both aligning specific biolandmarks and reducing reconstructed fracture fragments.Fracture lines were found and traced in order to generate an ankle fracture map.RESULTS This study involved 112 patients with a mean age of 49,comprising 32 pronationexternal rotation grade IV fractures and 80 supination-external rotation grade IV fractures according to the Lauge-Hansen classification system.Three-dimensional maps showed that the posterior ankle fracture fragments in the supinationexternal rotation grade IV group were relatively smaller than those in the pronation-external rotation grade IV group after posterior malleolus fracture.In addition,the distribution analyses on posterior malleolus fracture lines indicated that the supination-external rotation grade IV group tended to have higher linear density but more concentrated and orderly distribution fractures compared to the pronation-external rotation grade IV group.CONCLUSION Fracture maps revealed the fracture characteristics and recurrent patterns of posterior malleolar fractures,which might help to improve the understanding of ankle fracture as well as increase opportunities for follow-up research and aid clinical decision-making.展开更多
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ...Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.展开更多
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl...The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.展开更多
We present a case of a patient with rare anatomy of a maxillary second molar with three mesiobuccal root canals and a maxillary third molar with four separate roots, identified using multi-slice computed topography ...We present a case of a patient with rare anatomy of a maxillary second molar with three mesiobuccal root canals and a maxillary third molar with four separate roots, identified using multi-slice computed topography (CT) and three-dimensional reconstruction techniques. The described case enriched/might enrich our knowledge about possible anatomical aberrations of maxillary molars. In addition, we demonstrate the role of multi-slice CT as an objective tool for confirmatory diagnosis and successful endodontic management.展开更多
To correct a lower limb deformity, orthopedic surgeons must have an exact understanding of the deformity. In general, preoperative planning is carried out using anterior-posterior (AP) and lateral radiographs. However...To correct a lower limb deformity, orthopedic surgeons must have an exact understanding of the deformity. In general, preoperative planning is carried out using anterior-posterior (AP) and lateral radiographs. However, for severe cases with a combination of angular and rotational deformities of the lower limb, obtaining true AP and lateral radiographs is difficult and accurate calculation of the rotational deformity from radiographs is impossible. In this report, we propose to focus on preoperative assessment using three-dimensional (3D) reconstruction images of computed tomography (CT) scans for severe lower limb deformity in a patient with bilateral fibular hemimelia type II according to the Achterman- Kalamchi classification. She underwent bifocal deformity corrections of the bilateral tibiae using Taylor spatial frames in combination with the Ilizarov external fixator. Complete bony union was achieved, without angular deformity or limb length discrepancy.展开更多
AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHO...AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following:(1) the Minimal Mental State Examination;(2) the Hamilton Rating Scale for Depression;(3) Clinical Global Impression-Severity scale(CGI-S); and(4) SPECT imaging with 3D-SSP.RESULTS The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency.CONCLUSION We investigated whether these patients could be categorized as types: Type A(true AD), Type B(pseudodementia), Type C(occult AD), and Type D(true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD.展开更多
AIM: To evaluate the usefulness of three-dimensional computed tomography (3DCT) in laparoscopic surgery for colorectal carcinoma. METHODS: Seventy-two patients with colorectal cancer who underwent curative operati...AIM: To evaluate the usefulness of three-dimensional computed tomography (3DCT) in laparoscopic surgery for colorectal carcinoma. METHODS: Seventy-two patients with colorectal cancer who underwent curative operation at our hospital were enrolled in this study. They were classified into two groups by operative procedures. Sixteen patients underwent laparoscopic surgery, laparoscopic group (LG), while 56 patients underwent conventional open surgery, open group (OG). At our institution, contrast-enhanced CT is routinely performed as part of intra-abdominal screening and the 3D images of the major regional vessels are described. We have previously described about the preoperative visualization of the inferior mesenteric artery (IMA) by 3DCT. This time we newly acquired 3D images of the superior mesenteric artery (SMA)/superior mesenteric vein (SMV), ileocecal artery (ICA), middle colic artery (MCA), and inferior mesenteric vein (IMV). We have compared our two study groups with regard to five items, including clinical anastomotic leakage. We have discussed here the role of 3DCT in laparoscopic surgery for colorectal carcinoma. RESULTS: The mean length of the incision in LG was 4.6254-0.89 cm, which was significantly shorter than that in OG (P〈0.001). The association between ICA and SMV and SMA was described in the right-sided colectomy. The preoperative imaging of IMA and IMV was created in the rectosigmoidectomy. There was no significant difference in anastomotic leakage between the two groups, but no patients in LG experienced anastomotic leakage.CONCLUSION: Most of the patients are satisfied with the shorter incisional length following laparoscopic surgery. Preoperative visualization of the major regional vessels may be helpful for the secure treatment of the anastomosis in laparoscopic surgery for colorectal carcinoma.展开更多
BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s...BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy.展开更多
BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign...BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.展开更多
Objective To evaluate the clinical value of three dimensional computerized tomography angiography in the diagnosis and treatment of spontaneous subarachnoid hemorrhage. Methods 616 cases were diagnosed as suspected in...Objective To evaluate the clinical value of three dimensional computerized tomography angiography in the diagnosis and treatment of spontaneous subarachnoid hemorrhage. Methods 616 cases were diagnosed as suspected intracranial aneurysms in 3D CTA system. Computed tomographic scans and CTA studies were展开更多
An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, clo...An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, cloud data de-noising optimization, construction, display and operation of three-dimensional model, model editing, profile generation, calculation of goaf volume and roof area, Boolean calculation among models and interaction with the third party soft ware. Concerning this system with a concise interface, plentiful data input/output interfaces, it is featured with high integration, simple and convenient operations of applications. According to practice, in addition to being well-adapted, this system is favorably reliable and stable.展开更多
Objective:The purpose of this study was to evaluate three-dimensional(3D) dehiscence of upper anterior alveolar bone during incisor retraction and intrusion in adult patients with maximum anchorage.Methods:Twenty adul...Objective:The purpose of this study was to evaluate three-dimensional(3D) dehiscence of upper anterior alveolar bone during incisor retraction and intrusion in adult patients with maximum anchorage.Methods:Twenty adult patients with bimaxillary dentoalveolar protrusion had the four first premolars extracted.Miniscrews were placed to provide maximum anchorage for upper incisor retraction and intrusion.A computed tomography(CT) scan was performed after placement of the miniscrews and treatment.The 3D reconstructions of pre-and post-CT data were used to assess the dehiscence of upper anterior alveolar bone.Results:The amounts of upper incisor retraction at the edge and apex were(7.64±1.68) and(3.91±2.10) mm,respectively,and(1.34±0.74) mm of upper central incisor intrusion.Upper alveolar bone height losses at labial alveolar ridge crest(LAC) and palatal alveolar ridge crest(PAC) were 0.543 and 2.612 mm,respectively,and the percentages were(6.49±3.54)% and(27.42±9.77)%,respectively.The shape deformations of LAC-labial cortex bending point(LBP) and PAC-palatal cortex bending point(PBP) were(15.37±5.20)° and(6.43±3.27)°,respectively.Conclusions:Thus,for adult patients with bimaxillary protrusion,mechanobiological response of anterior alveolus should be taken into account during incisor retraction and intrusion.Pursuit of maximum anchorage might lead to upper anterior alveolar bone loss.展开更多
To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. T...To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (〈1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye.展开更多
基金Supported by the 2022 Provincial Quality Engineering Project for Higher Education Institutions,No.2022sx031the 2023 Provincial Quality Engineering Project for Higher Education Institutions,No.2023jyxm1071.
文摘BACKGROUND Inguinal hernias are common after surgery.Tension-free repair is widely accepted as the main method for managing inguinal hernias.Adequate exposure,coverage,and repair of the myopectineal orifice(MPO)are necessary.However,due to differences in race and sex,people’s body shapes vary.According to European guidelines,the patch should measure 10 cm×15 cm.If any part of the MPO is dissected,injury to the nerves,vascular network,or organs may occur during surgery,thereby leading to inguinal discomfort,pain,and seroma formation after surgery.Therefore,accurate localization and measurement of the boundary of the MPO are crucial for selecting the optimal patch for inguinal hernia repair.AIM To compare the size of the MPO measured on three-dimensional multislice spiral computed tomography(CT)with that measured via laparoscopy and explore the relevant factors influencing the size of the MPO.METHODS Clinical data from 74 patients who underwent laparoscopic tension-free inguinal hernia repair at the General Surgery Department of the First Affiliated Hospital of Anhui University of Science and Technology between September 2022 and July 2024 were collected and analyzed retrospectively.Transabdominal preperitoneal was performed.Sixty-four males and 10 females,with an average age of 58.30±12.32 years,were included.The clinical data of the patients were collected.The boundary of the MPO was measured on three-dimensional CT images before surgery and then again during transabdominal preperitoneal.All the preoperative and intraoperative data were analyzed via paired t-tests.A t-test was used for comparisons of age,body mass index,and sex between the groups.In the comparative analysis,a P value less than 0.05 indicated a significant difference.RESULTS The boundaries of the MPO on 3-dimensional CT images measured 7.05±0.47 cm and 6.27±0.61 cm,and the area of the MPO was 19.54±3.33 cm^(2).The boundaries of the MPO during surgery were 7.18±0.51 cm and 6.17±0.40 cm.The errors were not statistically significant.However,the intraoperative BD(the width of the MPO,P=0.024,P<0.05)and preoperative AC(the length of the MPO,P=0.045,P<0.05)significantly differed according to sex.The AC and BD measurements before and during surgery were not significantly different according to age,body mass index,hernia side or hernia type(P>0.05).CONCLUSION The application of this technology can aid in determining the most appropriate dissection range and patch size.
基金Supported by the Major State Basic Research Development Program of China(2011CB706501)the National Natural Science Foundation of China(51276157)
文摘Characterizing the complex two-phase hydrodynamics in structured packed columns requires a power- ful modeling tool. The traditional two-dimensional model exhibits limitations when one attempts to model the de- tailed two-phase flow inside the columns. The present paper presents a three-dimensional computational fluid dy- namics (CFD) model to simulate the two-phase flow in a representative unit of the column. The unit consists of an CFD calculations on column packed with Flexipak 1Y were implemented within the volume of fluid (VOF) mathe- matical framework. The CFD model was validated by comparing the calculated thickness of liquid film with the available experimental data. Special attention was given to quantitative analysis of the effects of gravity on the hy- drodynamics. Fluctuations in the liquid mass flow rate and the calculated pressure drop loss were found to be quali- tatively in agreement with the experimental observations.
基金Projects(41674080,41674079)supported by the National Natural Science Foundation of China
文摘A modeling tool for simulating three-dimensional land frequency-domain controlled-source electromagnetic surveys,based on a finite-element discretization of the Helmholtz equation for the electric fields,has been developed.The main difference between our modeling method and those previous works is edge finite-element approach applied to solving the three-dimensional land frequency-domain electromagnetic responses generated by horizontal electric dipole source.Firstly,the edge finite-element equation is formulated through the Galerkin method based on Helmholtz equation of the electric fields.Secondly,in order to check the validity of the modeling code,the numerical results are compared with the analytical solutions for a homogeneous half-space model.Finally,other three models are simulated with three-dimensional electromagnetic responses.The results indicate that the method can be applied for solving three-dimensional electromagnetic responses.The algorithm has been demonstrated,which can be effective to modeling the complex geo-electrical structures.This efficient algorithm will help to study the distribution laws of3-D land frequency-domain controlled-source electromagnetic responses and to setup basis for research of three-dimensional inversion.
基金supported by the National Natural Science Foundation of China (Grant Nos. 12102312 and 41372314)State Key Laboratory of Geohazard Prevention and Geoenvironment Protection Open Foundation, Chengdu University of Technology, China (Grant No. SKLGP2021K011)
文摘Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results.
文摘Objective To evaluate the effectiveness of three-dimensional computed tomography (3D-CT) guided radiofi'equency trigeminal rhizotomy (RF-TR) in treatment of idiopathic trigeminal neuralgia (1TN). Methods From 1999 to 2001, 18 patients with ITN were treated with percutaneous controlled RF-TR. Intraoperative 3D-CT scanning was performed to guide the trajectory of the puncture. After correction of the needle tip according to the CT scans and stimulation effects, 2 to 5 lesions were made for a duration of 60-90 seconds at a temperature of 60℃ to 75℃ depending on the pain distribution and the age of patient. The needles located in foramen ovale. Pain alleviated immediately with no serious complication in all patients. The patients were followed up for an average of 31.5 months (range 24-41 months). Acute pain relief was experienced by 17 patients after the procedure, reaching an initial success rate of 94.4%. Early (〈 6 months) pain recurrence was observed in 2 patients (11.1%), whereas late (〉 6 months) recurrence was reported in 3 patients (16.7%). Thirteen patients had complete pain control, with no need for medication thereafter. Five cases experienced partial pain relief, but required medication at a lower dose than in the preoperative period. Conclusion 3D-CT foramen ovale locations can raise the successful rate of puncture, enhance the safety, and reduce the incidence rate of complication.
文摘BACKGROUND : Digital subtraction angiography (DSA) is always regarded as the golden standard for diagnosis of intracranial aneurysm; however, the procedure is complex, traumatic, expensive and easy to induce vascular complication. Three-dimensional computed tomography angiography (3D-CTA) can make up deficiencies of DSA; therefore, it is used in clinical therapy wider and wider. OBJECTIVE : To evaluate the clinical effect of 3D-CTA on disruption and hemorrhage of intracranial aneurysm pre- and post-operation and compare with the effect of DSA. DESIGN : Auto-control contrast observation SETTING : Department of Neurosurgery, Shengjing Hospital of China Medical University PARTICIPANTS : A number of 106 patients with disruption and hemorrhage of intracranial aneurysm were selected from the Department of Neurosurgery, Shengjing Hospital of China Medical University from January 2003 to April 2006. All patients were diagnosed with cranial operation and consent. There were 47 males and 59 females aged from 3-76 years with the mean age of (47±13) years. Among them, 82 patients had extensive subarachnoid hemorrhage (SAH), 7 had hemorrhage at longitudinal fissure, and 17 had hemorrhage at ambiens cistema and lateral fissure. Moreover, intraventricular hematocele was accompanied on 13 patients and hematom on 9 patients. METHODS: (1) 3D-CTA examination: Siemens SOMATOM Sensation 64 CT was used in this study. The thickness was 1 mm and interval of reconstruction was 0.8 mm. Localizing section was plainly scanned as the standard of canthus line. Scan ranged from 30 mm below sella to 50 mm above sella. Non-ion contrast medium of Omnipaque 350 (concentration of iodine was 350 g/L) was inserted into anterior vein of elbow with 18G trochar retained with high-pressured injectoc pum. The speed was 4.5 mL/s and the total volume was 80-100 mL with the means of 90 mL. Scan started at 10-20 s after injection of contrast medium. Original image was dealt with Leonardo workstation and retreated with Syngo software. Volume rendering and maximum intensity projection were used to reconstructed images, (2) All 106 patients suffered from occlusion of aneurysm clamp. Before operation, 3D-CTA was undertaken and DSA was followed. After operation, patients were rechecked with 3D-CTA. MAIN OUTCOME MEASURES: Comparisons between 3D-CTA and DSA. RESULTS : All 106 patients were involved in the final analysis. (1) Examination of 3D-CTA and DSA: Among 118 patients with aneurysm, 110 were checked with 3D-CTA and the detected rate was 93.2% (110/118). Among other 8 cases, 3 were negative and checked again with DSA; 1 had pericallosal aneurysm, 1 ophthalmic aneurysm, and 1 anterior choroidal artery of aneurysm. 3D-CTA results of other 5 cases were suspicious, and then, they were regarded as having aneurysm with DSA. Before operation, correlation among site, body, neck of aneurysm and peripheral anatomic structure were shown sufficiently. After operation, 82 patients were rechecked with 3D-CTA, which was complete occlusion, precise, unobvious constriction, emphraxis or remains as compared with 3D-CTA those pre-operation. (2) Characteristics of 3D-CTA: With multiple vessels and angles, 3D-CTA observed the relationship between aneurysm neck and carried artery and showed thrombosis in cavity of aneurysm, calcification of aneurysm wall and peripheral structure of vessel at the same time. However, DSA could not detect the reactions mentioned above. It could delete image of cranium, simulate image of operative route, eliminate artifact induced by metal, but not distinguish blood stream direction. Meanwhile, posterior communicating artery was always poor during circle of Willis artery showing. CONCLUSION: (1) 3D-CTA is characterized by simple operation and non-invasive showing vascular stereo structure and correlation. Therefore, it is significant for diagnosis and designing plan of operative approach and focal location pre-operation and evaluating effect post-operation. (2) 3D-CTA does not completely replace DSA on the diagnosis of intracranial aneurysm.
基金Supported by The National Natural Science Foundation of China,No.81800050Natural Science Fund of Yangzhou City,No.YZ2017119Science and Technology Innovation Cultivation Program of Yangzhou University,No.2017CXJ122
文摘BACKGROUND Situs inversus totalis(SIT)is a rare congenital condition that is characterized by a complete mirror image of the typical arrangement of the thoracic and abdominal viscera.Performing thoracoscopic segmentectomy for a patient with lung cancer and SIT is an extremely skilled and challenging surgical procedure.CASE SUMMARY A 41-year old woman with a medical history of dextrocardia since childhood was admitted to our hospital with a mixed ground-glass opacity(mGGO)in her left lung field,discovered by computed tomography during her health checkup.In order to facilitate surgical orientation,three-dimensional computed tomography bronchography and angiography(3D-CTBA)was preoperatively carried out.The result of 3D-CTBA was consistent with the diagnosis of SIT and an mGGO in the posterior segment of the left upper lobe(LS2).Surgery was conducted in accordance with preoperative 3D-CTBA and designed surgical procedure,combined with intraoperative navigation.Final pathological examination revealed in situ adenocarcinoma.The patient’s postoperative condition was uneventful and no complications were observed.CONCLUSION We present the first case of lung cancer in a patient with SIT who successfully underwent thoracoscopic segmentectomy assisted by 3D-CTBA.This is a new technique that covers precise confirmation and dissection of targeted structures and intersegmental demarcation,and can help achieve a meticulous anatomical segmentectomy.
基金Supported by Multicenter Clinical Trial of h UC-MSCs in the Treatment of Late Chronic Spinal Cord Injury,No.2017YFA0105404Key Discipline Construction Project of Pudong Health Bureau of Shanghai,No.PWZxk2017-08
文摘BACKGROUND Posterior malleolar fractures have been reported to occur in<40%of ankle fractures.AIM To reveal the recurrent patterns and characteristics of posterior malleolar fractures by creating fracture maps of the posterior malleolar fractures through the use of computed tomography mapping.METHODS A consecutive series of posterior malleolar fractures was used to create threedimensional reconstruction images,which were oriented and superimposed to fit an ankle model template by both aligning specific biolandmarks and reducing reconstructed fracture fragments.Fracture lines were found and traced in order to generate an ankle fracture map.RESULTS This study involved 112 patients with a mean age of 49,comprising 32 pronationexternal rotation grade IV fractures and 80 supination-external rotation grade IV fractures according to the Lauge-Hansen classification system.Three-dimensional maps showed that the posterior ankle fracture fragments in the supinationexternal rotation grade IV group were relatively smaller than those in the pronation-external rotation grade IV group after posterior malleolus fracture.In addition,the distribution analyses on posterior malleolus fracture lines indicated that the supination-external rotation grade IV group tended to have higher linear density but more concentrated and orderly distribution fractures compared to the pronation-external rotation grade IV group.CONCLUSION Fracture maps revealed the fracture characteristics and recurrent patterns of posterior malleolar fractures,which might help to improve the understanding of ankle fracture as well as increase opportunities for follow-up research and aid clinical decision-making.
基金Supported by the Hundred Talents Program of Chinese Academy of Sciencesthe National Basic Research Program of China under Grant No 2014CB339803+2 种基金the Major National Development Project of Scientific Instrument and Equipment under Grant No2011YQ150021the National Natural Science Foundation of China under Grant Nos 61575214,61574155,61404149 and 61404150the Shanghai Municipal Commission of Science and Technology under Grant Nos 14530711300,15560722000 and 15ZR1447500
文摘Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.
基金supported by the National Natural Science Foundation Project(41501283)Beijing Science and Technology Plan Project(Z161100000916012)+2 种基金the National Key Research and Development Program(2017YFD0600901)Special Fund for Beijing Common Construction Projectthe Fundamental Research Funds for the Central Universities(2015ZCQ-GX-04)
文摘The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.
文摘We present a case of a patient with rare anatomy of a maxillary second molar with three mesiobuccal root canals and a maxillary third molar with four separate roots, identified using multi-slice computed topography (CT) and three-dimensional reconstruction techniques. The described case enriched/might enrich our knowledge about possible anatomical aberrations of maxillary molars. In addition, we demonstrate the role of multi-slice CT as an objective tool for confirmatory diagnosis and successful endodontic management.
文摘To correct a lower limb deformity, orthopedic surgeons must have an exact understanding of the deformity. In general, preoperative planning is carried out using anterior-posterior (AP) and lateral radiographs. However, for severe cases with a combination of angular and rotational deformities of the lower limb, obtaining true AP and lateral radiographs is difficult and accurate calculation of the rotational deformity from radiographs is impossible. In this report, we propose to focus on preoperative assessment using three-dimensional (3D) reconstruction images of computed tomography (CT) scans for severe lower limb deformity in a patient with bilateral fibular hemimelia type II according to the Achterman- Kalamchi classification. She underwent bifocal deformity corrections of the bilateral tibiae using Taylor spatial frames in combination with the Ilizarov external fixator. Complete bony union was achieved, without angular deformity or limb length discrepancy.
文摘AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following:(1) the Minimal Mental State Examination;(2) the Hamilton Rating Scale for Depression;(3) Clinical Global Impression-Severity scale(CGI-S); and(4) SPECT imaging with 3D-SSP.RESULTS The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency.CONCLUSION We investigated whether these patients could be categorized as types: Type A(true AD), Type B(pseudodementia), Type C(occult AD), and Type D(true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD.
文摘AIM: To evaluate the usefulness of three-dimensional computed tomography (3DCT) in laparoscopic surgery for colorectal carcinoma. METHODS: Seventy-two patients with colorectal cancer who underwent curative operation at our hospital were enrolled in this study. They were classified into two groups by operative procedures. Sixteen patients underwent laparoscopic surgery, laparoscopic group (LG), while 56 patients underwent conventional open surgery, open group (OG). At our institution, contrast-enhanced CT is routinely performed as part of intra-abdominal screening and the 3D images of the major regional vessels are described. We have previously described about the preoperative visualization of the inferior mesenteric artery (IMA) by 3DCT. This time we newly acquired 3D images of the superior mesenteric artery (SMA)/superior mesenteric vein (SMV), ileocecal artery (ICA), middle colic artery (MCA), and inferior mesenteric vein (IMV). We have compared our two study groups with regard to five items, including clinical anastomotic leakage. We have discussed here the role of 3DCT in laparoscopic surgery for colorectal carcinoma. RESULTS: The mean length of the incision in LG was 4.6254-0.89 cm, which was significantly shorter than that in OG (P〈0.001). The association between ICA and SMV and SMA was described in the right-sided colectomy. The preoperative imaging of IMA and IMV was created in the rectosigmoidectomy. There was no significant difference in anastomotic leakage between the two groups, but no patients in LG experienced anastomotic leakage.CONCLUSION: Most of the patients are satisfied with the shorter incisional length following laparoscopic surgery. Preoperative visualization of the major regional vessels may be helpful for the secure treatment of the anastomosis in laparoscopic surgery for colorectal carcinoma.
文摘BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy.
文摘BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.
文摘Objective To evaluate the clinical value of three dimensional computerized tomography angiography in the diagnosis and treatment of spontaneous subarachnoid hemorrhage. Methods 616 cases were diagnosed as suspected intracranial aneurysms in 3D CTA system. Computed tomographic scans and CTA studies were
基金Project(51274250)supported by the National Natural Science Foundation of ChinaProject(2012BAK09B02-05)supported by the National Key Technology R&D Program during the 12th Five-year Plan of China
文摘An integration processing system of three-dimensional laser scanning information visualization in goaf was developed. It is provided with multiple functions, such as laser scanning information management for goaf, cloud data de-noising optimization, construction, display and operation of three-dimensional model, model editing, profile generation, calculation of goaf volume and roof area, Boolean calculation among models and interaction with the third party soft ware. Concerning this system with a concise interface, plentiful data input/output interfaces, it is featured with high integration, simple and convenient operations of applications. According to practice, in addition to being well-adapted, this system is favorably reliable and stable.
基金Project supported by the Shandong Science and Technology Planning Project Contract Research (Nos. 2008GG30002019 and 2008GG 30001001) of Chinathe Shandong University Dental School Project Research (Nos. P2009009,P2009010,and P2010010),China
文摘Objective:The purpose of this study was to evaluate three-dimensional(3D) dehiscence of upper anterior alveolar bone during incisor retraction and intrusion in adult patients with maximum anchorage.Methods:Twenty adult patients with bimaxillary dentoalveolar protrusion had the four first premolars extracted.Miniscrews were placed to provide maximum anchorage for upper incisor retraction and intrusion.A computed tomography(CT) scan was performed after placement of the miniscrews and treatment.The 3D reconstructions of pre-and post-CT data were used to assess the dehiscence of upper anterior alveolar bone.Results:The amounts of upper incisor retraction at the edge and apex were(7.64±1.68) and(3.91±2.10) mm,respectively,and(1.34±0.74) mm of upper central incisor intrusion.Upper alveolar bone height losses at labial alveolar ridge crest(LAC) and palatal alveolar ridge crest(PAC) were 0.543 and 2.612 mm,respectively,and the percentages were(6.49±3.54)% and(27.42±9.77)%,respectively.The shape deformations of LAC-labial cortex bending point(LBP) and PAC-palatal cortex bending point(PBP) were(15.37±5.20)° and(6.43±3.27)°,respectively.Conclusions:Thus,for adult patients with bimaxillary protrusion,mechanobiological response of anterior alveolus should be taken into account during incisor retraction and intrusion.Pursuit of maximum anchorage might lead to upper anterior alveolar bone loss.
基金supported by a Grant-in-Aid for Scientific Research (22659366) from the Japan Society for the Promotion of Science
文摘To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (〈1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye.