期刊文献+
共找到23,470篇文章
< 1 2 250 >
每页显示 20 50 100
Fabrication of grating-like polystyrene latex monolayer structure as three-dimensional calibration standards for scanning probe microscope
1
作者 朱国栋 曾志刚 +2 位作者 国璋 杜强国 严学俭 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第3期997-1001,共5页
This paper illuminates the preparation of grating-like polystyrene latex monolayer structure, which can minimize the effects of the size deviation of spheres and the defect transfer on the accuracy as calibration samp... This paper illuminates the preparation of grating-like polystyrene latex monolayer structure, which can minimize the effects of the size deviation of spheres and the defect transfer on the accuracy as calibration samples for micro-scopes. The latex films are grown on freshly cleaved mica substrates by vertical deposition method. The concentration dependence of the structure and the topography of latex films is characterized by optical microscope, ultraviolet- visible transmission spectrum and scanning probe microscope. The origination of such a grating-like structure is also discussed. 展开更多
关键词 polystyrene spheres scanning probe microscope grating-like structure calibration samrile
原文传递
Three-dimensional morphological and fluorescent imaging of zebrafish with a continuous-rotational light-sheet microscope
2
作者 Dongmin Zhang Guang Yang +3 位作者 Yao Tan Chong Chen Jie Zhang Hui Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期59-66,共8页
Light-sheet fluorescence microscopy(LSFM)has been widely used to image the three-dimensional(3D)structures and functions of various millimeter-size bio-specimen such as zebrafish.However,the sample adsorption and scat... Light-sheet fluorescence microscopy(LSFM)has been widely used to image the three-dimensional(3D)structures and functions of various millimeter-size bio-specimen such as zebrafish.However,the sample adsorption and scattering cause shading of the light-sheet illumination,preventing the even 3D image of thick samples.Herein,we report a continuous-rotational light-sheet microscope(CR-LSM)that enables simultaneous 3D bright-field and fluorescence imaging.With a high-accuracy rotational stage,CR-LSM records the outline projections and the fluorescent images of the sample at multiple rotation angles.Then,3D morphology and fluorescent structure were reconstructed with a developed algorithm.Using CR-LSM,zebrafish’s whole-fish contour and blood vessel structures were obtained simultaneously. 展开更多
关键词 Light-sheet microscope zebrafish blood vessels MORPHOLOGY
原文传递
Investigation of bubbles escape behavior from low basicity mold flux for high-Mn high-Al steels using 3D X-ray microscope
3
作者 Qiang Liu Xiang Li +3 位作者 Shen Du Ming Gao Yanbin Yin Jiongming Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期102-110,共9页
During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a rest... During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels. 展开更多
关键词 mold flux low basicity BUBBLES three-dimensional X-ray microscope VISCOSITY
在线阅读 下载PDF
Three-dimensional atomic force microscopy based on tailored cantilever probe with flared tip 被引量:1
4
作者 ZHANG Rui WU Sen +3 位作者 XIAO Sha-sha HU Xiao-dong SHI Yu-shu FU Xing 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第4期388-396,共9页
In order to meet the requirements of nondestructive testing of true 3D topography of micro-nano structures,a novel three-dimensional atomic force microscope(3D-AFM)based on flared tip is developed.A high-precision sca... In order to meet the requirements of nondestructive testing of true 3D topography of micro-nano structures,a novel three-dimensional atomic force microscope(3D-AFM)based on flared tip is developed.A high-precision scanning platform is designed to achieve fast servo through moving probe and sample simultaneously,and several combined nanopositioning stages are used to guarantee linearity and orthogonality of displacement.To eliminate the signal deviation caused by AFM-head movement,a traceable optical lever system is designed for cantilever deformation detection.In addition,a method of tailoring the cantilever of commercial probe with flared tip is proposed to reduce the lateral force applied on the tip in measurement.The tailored probe is mounted on the 3D-AFM,and 3D imaging experiments are conducted on different samples by use of adaptive-angle scanning strategy.The results show the roob-mean-square value of the vertical displacement noise(RMS)of the prototype is less than 0.1 nm and the high/width measurement repeatability(peak-to-peak)is less than 2.5 nm. 展开更多
关键词 three-dimensional atomic force microscope(3D-AFM) flared tip SCANNER optical lever vector scanning
在线阅读 下载PDF
Three-dimension collision-free trajectory planning of UAVs based on ADS-B information in low-altitude urban airspace 被引量:2
5
作者 Chao DONG Yifan ZHANG +3 位作者 Ziye JIA Yiyang LIAO Lei ZHANG Qihui WU 《Chinese Journal of Aeronautics》 2025年第2期274-285,共12页
The environment of low-altitude urban airspace is complex and variable due to numerous obstacles,non-cooperative aircraft,and birds.Unmanned Aerial Vehicles(UAVs)leveraging environmental information to achieve three-d... The environment of low-altitude urban airspace is complex and variable due to numerous obstacles,non-cooperative aircraft,and birds.Unmanned Aerial Vehicles(UAVs)leveraging environmental information to achieve three-dimension collision-free trajectory planning is the prerequisite to ensure airspace security.However,the timely information of surrounding situation is difficult to acquire by UAVs,which further brings security risks.As a mature technology leveraged in traditional civil aviation,the Automatic Dependent Surveillance-Broadcast(ADS-B)realizes continuous surveillance of the information of aircraft.Consequently,we leverage ADS-B for surveillance and information broadcasting,and divide the aerial airspace into multiple sub-airspaces to improve flight safety in UAV trajectory planning.In detail,we propose the secure Sub-airSpaces Planning(SSP)algorithm and Particle Swarm Optimization Rapidly-exploring Random Trees(PSO-RRT)algorithm for the UAV trajectory planning in law-altitude airspace.The performance of the proposed algorithm is verified by simulations and the results show that SSP reduces both the maximum number of UAVs in the sub-airspace and the length of the trajectory,and PSO-RRT reduces the cost of UAV trajectory in the sub-airspace. 展开更多
关键词 three-dimension trajectory planning of UAV Collision avoidance Sliding window ADS-B Low-altitude urban airspace
原文传递
Application of Motic Digital Microscope Mutual System in the Experimental Teaching of Medicinal Plants
6
作者 Hailin LU Min GUO +3 位作者 Shenggao YIN Bin LI Yonghua LI Haicheng WEN 《Medicinal Plant》 2025年第2期88-90,共3页
In comparison with conventional experimental teaching methods,the implementation of the Motic digital microscope mutual system in the experimental teaching of medicinal botany has been demonstrated to be a highly effi... In comparison with conventional experimental teaching methods,the implementation of the Motic digital microscope mutual system in the experimental teaching of medicinal botany has been demonstrated to be a highly efficacious approach to enhance the teaching level of experimental courses in medicinal botany.The implementation of a digital microscope mutual system in experimental teaching not only enhances students practical skills in laboratory operations but also increases classroom efficiency.Furthermore,it supports personalized development among students while fostering innovative thinking,independent learning capabilities,and analysis and problem-solving skills.Additionally,this approach contributes to the enhancement of students scientific literacy. 展开更多
关键词 microscope Medicinal plants Mutual system Experimental teaching
在线阅读 下载PDF
Navigating anatomical complexity in laparoscopic sigmoid cancer surgery:A three-dimension reconstruction protocol for intraoperative safety and efficiency
7
作者 Zong-Xian Zhao Run-Dong Yao +3 位作者 Zong-Ju Hu Chao-Qian Chen Shu Zhu Yuan Yao 《World Journal of Gastrointestinal Surgery》 2025年第8期350-361,共12页
BACKGROUND Sigmoid colon cancer faces challenges due to anatomical diversity,including variable inferior mesenteric artery(IMA)branching and tumor localization complexities,which increase intraoperative risks.AIM To c... BACKGROUND Sigmoid colon cancer faces challenges due to anatomical diversity,including variable inferior mesenteric artery(IMA)branching and tumor localization complexities,which increase intraoperative risks.AIM To comprehensively evaluate the impact of three-dimensional(3D)visualization technology on enhancing surgical precision and safety,as well as optimizing perioperative outcomes in laparoscopic sigmoid cancer resection.METHODS A prospective cohort of 106 patients(January 2023 to December 2024)undergoing laparoscopic sigmoid cancer resection was divided into the 3D(n=55)group and the control(n=51)group.The 3D group underwent preoperative enhanced computed tomography reconstruction(3D Slicer 5.2.2&Mimics 19.0).3D reconstruction visualization navigation intraoperatively guided the following key steps:Tumor location,Toldt’s space dissection,IMA ligation level selection,regional lymph node dissection,and marginal artery preservation.Outcomes included operative parameters,lymph node yield,and recovery metrics.RESULTS The 3D group demonstrated a significantly shorter operative time(172.91±20.69 minutes vs 190.29±32.29 minutes;P=0.002),reduced blood loss(31.5±11.8 mL vs 44.1±23.4 mL,P=0.001),earlier postoperative flatus(2.23±0.54 days vs 2.53±0.61 days;P=0.013),shorter hospital length of stay(13.47±1.74 days vs 16.20±7.71 days;P=0.013),shorter postoperative length of stay(8.6±2.6 days vs 10.5±4.9 days;P=0.014),and earlier postoperative exhaust time(2.23±0.54 days vs 2.53±0.61 days;P=0.013).Furthermore,the 3D group exhibited a higher mean number of lymph nodes harvested(16.91±5.74 vs 14.45±5.66;P=0.030).CONCLUSION The 3D visualization technology effectively addresses sigmoid colon anatomical complexity through surgical navigation,improving procedural safety and efficiency. 展开更多
关键词 three-dimension reconstruction Sigmoid colon cancer Visualization Inferior mesenteric artery Anatomical complexity Intraoperative safety
暂未订购
An investigation of single-phased metallic solidification process using high-temperature confocal laser scanning microscope combined with differential scanning colorimetry
8
作者 Xing-zhi Zhou De-yong Wang +6 位作者 Tian-peng Qu Dong Hou Shao-yan Hu Jun Tian Xiang-long Li Lei Fan Zhi-xiao Zhang 《Journal of Iron and Steel Research International》 2025年第2期437-451,共15页
To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1... To investigate the nucleation behavior during the single-phased metallic solidification process,the commercial ultrapure ferritic stainless steels with no(Initial steel)and various melt treatments(R1,MR1,Y2,MY1,and M1 steels)were used to carry out the differential scanning colorimetry(DSC)and high-temperature confocal laser scanning microscope(HT-CLSM)experiments.Based on the results of DSC experiments,the equilibrium solidification process as well as the relationship among the critical undercooling degree(△T_(c)^(DSC)),latent heat of fusion/crystallization(△H_(f)/△H_(c)),equiaxed grain ratio(ER),and average grain size(△_(ave)^(ingot))was revealed.ER is increased with the decreasing△T_(c)^(DSC)and increasing△H_(f)/△H_(c);however,△_(ave)^(ingot)is decreased with them.Referring to the results of HT-CLSM experiments,the average sizes of micro-/macrostructures(d_(ave)/D_(ave)/)are decreased with the increasing cooling rate,as well as the difference between and apparent critical undercooling degree(△T_(c)^(CLSM))was revealed.The heterogeneous nucleation of the crystal nuclei occurs only if△T_(c)^(CLSM)>△T_(c)^(DSC).Combining with the interfacial wetting-lattice mismatch heterogeneous nucleation model,the dynamic mechanism of the metallic solidification was revealed.The as-cast grains of the melt-treated samples were obviously refined,owing to the much higher actual heterogeneous nucleation rates(I_(heter.,i))obtained through melt treatments,and the heterogeneous nucleation rates(I_(heter.,ij))for all samples are increased with the cooling rates,firmly confirming that the as-cast grains of each sample could be refined by the increasing cooling rates. 展开更多
关键词 NUCLEATION Metallic solidification process Differential scanning colorimetry High-temperature confocal laser scanning microscope Interfacial wetting-lattice mismatch heterogeneous nucleation model
原文传递
Investigation into the Effect and Microscopic Mechanism of Retarders on Two-component Backfilling Grout in Shield Engineering
9
作者 CAI Hongwei MIN Fanlu +5 位作者 YUAN Rui LI Zhen ZHANG Jianfeng WANG Dengfeng ZHANG Yazhou YAO Zhanhu 《Journal of Wuhan University of Technology(Materials Science)》 2026年第1期84-95,共12页
To address the issues of short setting time and high bleeding rate of A component,which easily cause pipe plugging and poor grouting performance when a two-component grout is injected synchronously behind the Segmenta... To address the issues of short setting time and high bleeding rate of A component,which easily cause pipe plugging and poor grouting performance when a two-component grout is injected synchronously behind the Segmental Lining,the inorganic retarder sodium pyrophosphate(TSPP)and three organic retarders were added to the A component:sodium citrate(SC),sodium tartrate(ST)and glycerol(GLY).The effect law and microscopic mechanism of viscosity,bleeding rate,setting time,gelling time,compressive strength,and stone rate were investigated.The results revealed that the addition of retarders could enhance the stability and setting time of the A component and increase the gelling time,stone rate,and compressive strength of two-component grout.Among them,the performance of the grout with an SC dosage of 0.1% was superior.The bleeding rate of this grout was reduced to 3.5%,the stone rate of the two-component grout was more than 99%,and the early compressive strength and late compressive strength of this grout were increased by approximately 35% and 7%,respectively.The initial and final setting time of the A component with a TSPP dosage of 0.3% was the longest,which was prolonged to 17 and 26 h,respectively.Microscopic analysis revealed that the four retarders hindered the hydration process of cement through complexation and adsorption,and inhibited the hydration of C_(3)S and the crystallisation of CH.Moreover,they reduced the defects caused by the rapid reaction of water glass and CH on the solid phase structure,enabled the microstructure of the stone body to be denser,and subsequently,enhanced the compressive strength. 展开更多
关键词 backfilling grout two-component grout RETARDER working performance gelling performance microscopic mechanism
原文传递
Virtual three-dimension reconstruction of Sidu(四渎 TE 9) 被引量:3
10
作者 刘延祥 严振国 +2 位作者 郭义 庄天戈 邵水金 《World Journal of Acupuncture-Moxibustion》 CSCD 2016年第1期30-33,41,共5页
Objective Aim to create a three-dimension(3D) reconstruction of acupuncture needling at Sidu(四渎 TE 9).Methods First,the skin,subcutaneous tissue,muscles,the blood vessels and nerves near TE 9 were defined in ana... Objective Aim to create a three-dimension(3D) reconstruction of acupuncture needling at Sidu(四渎 TE 9).Methods First,the skin,subcutaneous tissue,muscles,the blood vessels and nerves near TE 9 were defined in anatomical terms.Second,the above anatomical structures including the dissected muscles associated with at TE 9,the underlying blood vessels and nerves were reconstructed in 3D.Third,the process of acupuncturing TE 9 on a virtual human body was simulated using the VOXEL-MAN technology.Results Both the local anatomy of the point and the process of acupuncture needling at TE 9 were reconstructed.Different layers of tissues were visualized during the process of needling,as the needle was inserted and manipulated at the point.Conclusions Virtual 3D reconstruction can contribute to research on the anatomical structure of acupoints and the visualization of the acupoints.We recommend that it be fully utilized in acupuncture research. 展开更多
关键词 ACUPUNCTURE ACUPOINT VISUALIZATION three-dimension reconstruction
原文传递
Observation for Leaf Epidermal Characteristics of Four Different Pomegranate Cultivars under Scanning Electron Microscope 被引量:5
11
作者 徐迎碧 丁之恩 《Agricultural Science & Technology》 CAS 2008年第3期99-102,共4页
[Objective] The research aimed to provide reference for classification of pomegranate cultivars and studies of genetic relationship among pomegranate cultivars.[Method] The electron microscope scanning was used to com... [Objective] The research aimed to provide reference for classification of pomegranate cultivars and studies of genetic relationship among pomegranate cultivars.[Method] The electron microscope scanning was used to comparatively observe leaf epidermal structures of 4 pomegranate cultivars.[Result] The upper epidermal structures of 4 pomegranate cultivars were similar and showed reticular structure .However, the differences existed in lower epidermis,such as cell shape,cell size and arrangement mode of cell as well as stomatal density,while the structures of leaf vein in lower epidermis of 4 pomegranate cultivars were similar.[Conclusion] The research provided morphological references for studying heterosis of pomegranate to some extent. 展开更多
关键词 POMEGRANATE CULTIVAR LEAF EPIDERMIS Electron microscope scanning
在线阅读 下载PDF
Solidification process of conventional superalloy by confocal scanning laser microscope 被引量:6
12
作者 缪竹骏 单爱党 +3 位作者 王威 卢俊 徐文亮 宋洪伟 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第2期236-242,共7页
The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and te... The solidification process of a conventional superalloy, IN718, was investigated by confocal scanning laser microscope (CSLM). The liquid fraction during solidification was obtained as a function of real time and temperature in reference with the in-situ observation. The characteristics of L→γ transformation were analyzed and the γ growing rate of each stage was also calculated. Scheil equation was employed to predict the segregation behavior, and the predict results are in consistence with the experimental results. As a result, the confocal scanning laser microscope shows a great potential for solidification process research. 展开更多
关键词 IN718 alloy SOLIDIFICATION IN-SITU confocal scanning laser microscope SEGREGATION
在线阅读 下载PDF
Changes of Calmodulin Distribution in the Embryo Sac of Oryza sativa Before and After Fertilization: an Immunogold Electron Microscope Study 被引量:4
13
作者 杨军 赵洁 +1 位作者 梁世平 杨弘远 《Acta Botanica Sinica》 CSCD 2002年第3期264-272,共9页
Changes of calmodulin (CaM) distribution in the embryo sac of rice (Oryza sativa subsp. Japonica) at various stages before and after fertilization have been investigated by using immunogold electron microscopy. Before... Changes of calmodulin (CaM) distribution in the embryo sac of rice (Oryza sativa subsp. Japonica) at various stages before and after fertilization have been investigated by using immunogold electron microscopy. Before pollination, both cytoplasm and vacuoles of the egg cell, synergids and central cell were labeled by gold particles. A small amount of gold particles were localized in the nucleus, endoplasmic reticulum, mitochondria and dictyosomes. From pollination to fertilization, CaM amount increased in these cells, especially rich in the starch of amyloplasts. Increase of gold particles in the central cell began about 2 h earlier than that in the egg cell. There was no distinct difference of CaM amount between the degenerated and the persistent synergids. It is interesting to observe an obvious change of CaM distribution form during pollination and fertilization from scattered single particles to clustered particles, and back again to single particles after the fertilization finished. CaM was also localized extracellularly in the embryo sac wall as well as in the wall and intercellular space of nucellus cells. The extracellular CaM also changes in its amount and form after pollination. These results suggest that CaM, either intra- or extra-cellular, may play important roles in fertilization and zygote formation. 展开更多
关键词 CALMODULIN POLLINATION FERTILIZATION rice embryo sac immunogold electron microscope localization
在线阅读 下载PDF
用IM Microscope方法计算无源互调产物
14
作者 王海宁 梁建刚 +1 位作者 王积勤 张晨新 《空军工程大学学报(自然科学版)》 CSCD 北大核心 2005年第3期47-49,共3页
在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的。在IM Micro-scope方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,并实例验证了该方法... 在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的。在IM Micro-scope方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,并实例验证了该方法的正确性。 展开更多
关键词 无源互调(PIM) 无源互调产物(PIMP) IM microscope RF
在线阅读 下载PDF
用IM Microscope方法计算无源互调产物
15
作者 王海宁 梁建刚 +1 位作者 王积勤 张晨新 《弹箭与制导学报》 CSCD 北大核心 2005年第S4期458-460,共3页
在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的,因为这样可以直观的看出无源互调噪声对于器件或者系统的影响。在众多的预测方法中,IM Microscope 方法具有很多优点。文中在IM Microscope 方法的基础上进行了改进,... 在微波与射频无源互调的研究中,预测无源互调产物的电平是非常重要的,因为这样可以直观的看出无源互调噪声对于器件或者系统的影响。在众多的预测方法中,IM Microscope 方法具有很多优点。文中在IM Microscope 方法的基础上进行了改进,在预测过程中直接引入输入信号经过非线性器件后输出信号的幅度和相位变化模型,给出了详细的数学模型,这样可以大大减少很多的测量工作。 展开更多
关键词 无源互调(PIM) 无源互调产物(PIMP) IM microscope RF
在线阅读 下载PDF
Obsevation for Epidermal Ultrastructure of Nostoc sphaeroides Kutzing under Scanning Electron Microscope 被引量:1
16
作者 李莉 《Agricultural Science & Technology》 CAS 2009年第1期1-3,共3页
[Objective]The experiment aimed to explore a new way for observing surface structure of Nostoc sphaeroides Kutzing. [Method] The scanning electron microscope was used to observe the epidermal ultrastructure of wild an... [Objective]The experiment aimed to explore a new way for observing surface structure of Nostoc sphaeroides Kutzing. [Method] The scanning electron microscope was used to observe the epidermal ultrastructure of wild and cultured Nostoc sphaeroides Kutzing. [ Result] The epidermis of wild and cultured Nostoc sphaeroides Kutzing showed mixture structure of fibril colloid which was reticular arranged. The difference between wild and cultured Nostoc sphaeroides Kutzing was that the outer epidermis of cultured Nostoc sphaeroides Kutzing had trichome distribution but the wild Nostoc sphaeroides Kutzing did not has such distribution. The obsevation results of under smaller than 10 μm by scanning electron microscope was touched thick and showed many folds and distortions. [ Conclusion] The scanning electron microscope was an effective way to study development of Nostoc sphaeroides Kutzing colony and it was worth popularizing. 展开更多
关键词 Nostoc sphaeroides Kutzing Epidermal ultrastructure Scanning electron microscope
在线阅读 下载PDF
MicroScope高分辨率成像测井技术及应用
17
作者 夏竹君 张兰江 +2 位作者 张贺举 杨坚 付琛 《海洋石油》 CAS 2019年第1期54-60,共7页
MicroScope随钻高分辨率成像测井技术是斯伦贝谢公司最新推出,能记录超高分辨率电阻率图像UHRI和多个探测深度深钮电阻率成像图,介绍了超高分辨率电阻率成像图UHRI识别岩性及地层结构、识别沉积构造、划分沉积微相、分析古水流与砂体展... MicroScope随钻高分辨率成像测井技术是斯伦贝谢公司最新推出,能记录超高分辨率电阻率图像UHRI和多个探测深度深钮电阻率成像图,介绍了超高分辨率电阻率成像图UHRI识别岩性及地层结构、识别沉积构造、划分沉积微相、分析古水流与砂体展布等的方法,在南海西部沉积相研究方面发挥了重要作用,是值得推广的新型成像测井技术。 展开更多
关键词 microscope 成像测井 沉积相 测井技术 南海西部
在线阅读 下载PDF
Observation of Helicotylenchus digonicus by Scanning Electron Microscope
18
作者 郑炜 《Plant Diseases and Pests》 CAS 2011年第5期32-33,37,共3页
[ Objective] The paper was to observe Helicotylenchus digonicus by scanning electron microscope (SEM). [ Method ] H. digonicus collected from Changxing of Zhejiang Province was observed under scanning electron micro... [ Objective] The paper was to observe Helicotylenchus digonicus by scanning electron microscope (SEM). [ Method ] H. digonicus collected from Changxing of Zhejiang Province was observed under scanning electron microscope, and its morphological structure was confmned under optical microscope. [ Resuit]The nematode specimens fixed by glutaraldehyde and osmium tetroxide and prepared by critical point drying were unmodified and unshrinkable with clear mor- phological structure, which could be scanned very well by scanning electron microscope. [ Conclusion ] The study provided reference for study and control of H. digonicus. 展开更多
关键词 Helicotylenchus d^gonicus Morphological structure Scanning electron microscope China
在线阅读 下载PDF
A Highly Stable Electrochemical Scanning Tunneling Microscope 被引量:1
19
作者 夏志刚 王纪浩 +1 位作者 侯玉斌 陆轻铀 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2015年第1期70-72,I0002,共4页
We demonstrate a home-built electrochemical scanning tunneling microscope (ECSTM). The ECSTM exhibits highly stable performance. The drifting rates in XY and Z directions of the ECSTM are about 67 and 55.6 pm/min, r... We demonstrate a home-built electrochemical scanning tunneling microscope (ECSTM). The ECSTM exhibits highly stable performance. The drifting rates in XY and Z directions of the ECSTM are about 67 and 55.6 pm/min, respectively. Moreover, a specially designed scanner unit successfully solves the well-known problem of large leakage current in high humidity atmosphere. The mechanical structure of the ECSTM is described in detail. The excellent performances of the system are demonstrated by the measured STM images (in copper sulfate solution), including clean and well-ordered large area morphology of Au(111) and the atomically resolved image of highly oriented pyrolytic graphite. 展开更多
关键词 Scanning tunneling microscope ELECTROCHEMISTRY Highly stable
在线阅读 下载PDF
3D digital image microscope system-assisted vasovasostomy and vasoepididymostomy in rats 被引量:4
20
作者 Peng Li Na-Chuan Liu +12 位作者 Er-Lei Zhi Chen-Cheng Yao Zhi-Liang Zhao Zhi-Yong Yu Qi-Meng Li Yu-Hua Huang Jie-Chang Ju Wen-Bin Huang Husanjan Rozi Zhi-Yong Ji San-Wei Guo Ru-Hui Tian Zheng Li 《Asian Journal of Andrology》 SCIE CAS CSCD 2021年第4期396-399,共4页
Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery.The three-dimensional(3D)digital image microscope system with a better 3D depth of field can rele... Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery.The three-dimensional(3D)digital image microscope system with a better 3D depth of field can release strain on the surgeon's neck and back,which can improve outcomes in microsurgery.We report a randomized prospective study of vasoepididymostomy and vasovasostomy using a 3D digital image microscope system(3D-DIM)in rats.A total of 16 adult male rats were randomly divided into two groups of 8 each:the standard operating microscope(SOM)group and the 3D-DIM group.The outcomes measured included the operative time,real-time postoperative mechanical patency,and anastomosis leakage.Furthermore,a user-friendly microscope score was designed to evaluate the ergonomic design and equipment characteristics of the microscope.There were no differences in operative time between the two groups.The real-time postoperative mechanical patency rates were 100.0%for both groups.The percentage of vasoepididymostomy anastomosis leakage was 16.7%in the SOM group and 25.0%in the 3D-DIM group;however,no vasovasostomy anastomosis leakage was found in either group.In terms of the ergonomic design,the 3D-DIM group obtained better scores based on the surgeon's feelings;in terms of the equipment characteristics,the 3D-DIM group had lower scores for clarity and higher scores for flexibility and adaptivity.Based on our randomized prospective study in a rat model,we believe that the 3D-DIM can improve surgeon comfort without compromising outcomes in male infertility reconstructive microsurgery,so the 3D-DIM might be widely used in the future. 展开更多
关键词 MICROSURGERY three-dimensional digital image microscope system VASOEPIDIDYMOSTOMY VASOVASOSTOMY
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部