Spectral diagnosis of radiation from laser plasma interaction and monochromation of radiation source are hot and important topics recently. Grating is one of the primary optical elements to do this job. Although easy ...Spectral diagnosis of radiation from laser plasma interaction and monochromation of radiation source are hot and important topics recently. Grating is one of the primary optical elements to do this job. Although easy to fabricate, traditional diffraction grating suffers from multi-order diffraction contamination. On the other hand, sinusoidal amplitude grating has the nonharmonic diffraction property, but it is too difficult to fabricate, especially for x-ray application. A novel nonharmonic diffraction grating named random position rectangle grating(RPRG) is proposed in this paper. Theoretical analysis and experiment results show that the RPRG is both higher order diffraction suppressing and not difficult to fabricate. Additionally, it is highly efficient; its first order absolute theoretical diffraction efficiency reaches 4.1%. Our result shows that RPRG is a novel tool for radiation diagnosis and monochromation.展开更多
The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order ...The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics.展开更多
The objective is to develop an approach for the determination of the target reliability index for serviceability limit state(SLS) of single piles. This contributes to conducting the SLS reliability-based design(RBD) o...The objective is to develop an approach for the determination of the target reliability index for serviceability limit state(SLS) of single piles. This contributes to conducting the SLS reliability-based design(RBD) of piles. Based on a two-parameter,hyperbolic curve-fitting equation describing the load-settlement relation of piles, the SLS model factor is defined. Then, taking into account the uncertainties of load-settlement model, load and bearing capacity of piles, the formula for computing the SLS reliability index(βsls) is obtained using the mean value first order second moment(MVFOSM) method. Meanwhile, the limit state function for conducting the SLS reliability analysis by the Monte Carlo simulation(MCS) method is established. These two methods are finally applied to determine the SLS target reliability index. Herein, the limiting tolerable settlement(slt) is treated as a random variable. For illustration, four load test databases from South Africa are compiled again to conduct reliability analysis and present the recommended target reliability indices. The results indicate that the MVFOSM method overestimates βsls compared to that computed by the MCS method. Besides, both factor of safety(FS) and slt are key factors influencing βsls, so the combination of FS and βsls is welcome to be used for the SLS reliability analysis of piles when slt is determined. For smaller slt, pile types and soils conditions have significant influence on the SLS target reliability indices; for larger slt, slt is the major factor having influence on the SLS target reliability indices. This proves that slt is the most key parameter for the determination of the SLS target reliability index.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.11375160)the National Science Instruments Major Project of China(Grant No.2012YQ130125)
文摘Spectral diagnosis of radiation from laser plasma interaction and monochromation of radiation source are hot and important topics recently. Grating is one of the primary optical elements to do this job. Although easy to fabricate, traditional diffraction grating suffers from multi-order diffraction contamination. On the other hand, sinusoidal amplitude grating has the nonharmonic diffraction property, but it is too difficult to fabricate, especially for x-ray application. A novel nonharmonic diffraction grating named random position rectangle grating(RPRG) is proposed in this paper. Theoretical analysis and experiment results show that the RPRG is both higher order diffraction suppressing and not difficult to fabricate. Additionally, it is highly efficient; its first order absolute theoretical diffraction efficiency reaches 4.1%. Our result shows that RPRG is a novel tool for radiation diagnosis and monochromation.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFA0206004)the National Natural Science Foundation of China(Grant No.11375160)the National Science Instruments Major Project of China(Grant No.2012YQ130125)
文摘The extreme ultraviolet and soft x-ray sources are widely used in various domains. Suppressing higher order harmonics and improving spectral purity are significant. This paper describes a novel method of higher order harmonics suppression with single order diffraction gratings in extreme ultraviolet and soft x-ray. The principle of harmonic suppression with single order diffraction grating is described, and an extreme ultraviolet and soft x-ray non-harmonics grating monochromator is designed based on the single order diffraction grating. The performance is simulated by an optical design software. The emergent beams of a monochromator with different gratings are measured by a transmission grating spectrometer. The results show that the single order diffraction grating can suppress higher order harmonics effectively, and it is expected to be widely used in synchrotron radiation, diagnostics of laser induced plasma, and astrophysics.
基金Projects(51278216,51308241)supported by the National Natural Science Foundation of ChinaProject(2013BS010)supported by the Funds of Henan University of Technology for High-level Talents,China
文摘The objective is to develop an approach for the determination of the target reliability index for serviceability limit state(SLS) of single piles. This contributes to conducting the SLS reliability-based design(RBD) of piles. Based on a two-parameter,hyperbolic curve-fitting equation describing the load-settlement relation of piles, the SLS model factor is defined. Then, taking into account the uncertainties of load-settlement model, load and bearing capacity of piles, the formula for computing the SLS reliability index(βsls) is obtained using the mean value first order second moment(MVFOSM) method. Meanwhile, the limit state function for conducting the SLS reliability analysis by the Monte Carlo simulation(MCS) method is established. These two methods are finally applied to determine the SLS target reliability index. Herein, the limiting tolerable settlement(slt) is treated as a random variable. For illustration, four load test databases from South Africa are compiled again to conduct reliability analysis and present the recommended target reliability indices. The results indicate that the MVFOSM method overestimates βsls compared to that computed by the MCS method. Besides, both factor of safety(FS) and slt are key factors influencing βsls, so the combination of FS and βsls is welcome to be used for the SLS reliability analysis of piles when slt is determined. For smaller slt, pile types and soils conditions have significant influence on the SLS target reliability indices; for larger slt, slt is the major factor having influence on the SLS target reliability indices. This proves that slt is the most key parameter for the determination of the SLS target reliability index.