In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results i...In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results in increased leakage current,decreased breakdown voltage,and lower nonlinearity,ultimately compromising their protective performance.To investigate the evolution in electrical properties during DC aging,this work developed a finite element model based on Voronoi networks and conducted accelerated aging tests on commercial varistors.Throughout the aging process,current-voltage characteristics and Schottky barrier parameters were measured and analyzed.The results indicate that when subjected to constant voltage,current flows through regions with larger grain sizes,forming discharge channels.As aging progresses,the current focus increases on these channels,leading to a decline in the varistor’s overall performance.Furthermore,analysis of the Schottky barrier parameters shows that the changes in electrical performance during aging are non-monotonic.These findings offer theoretical support for understanding the aging mechanisms and condition assessment of modern stable ZnO varistors.展开更多
Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energ...Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energy and load forecasting in active distribution networks(ADN),this paper proposes a multi-timescale coordinated optimal dispatch strategy that incorporates TSEH clusters.It utilizes the thermal storage characteristics and short-term regulation capabilities of TSEH,along with the rapid and gradual response characteristics of resources in active distribution grids,to develop a coordinated optimization dispatch mechanism for day-ahead,intraday,and real-time stages.It provides a coordinated optimized dispatch technique across several timescales for active distribution grids,taking into account the integration of TSEH clusters.The proposed method is validated on a modified IEEE 33-node system.Simulation results demonstrate that the participation of TSEH in collaborative optimization significantly reduces the total system operating cost by 8.71%compared to the scenario without TSEH.This cost reduction is attributed to a 10.84%decrease in interaction costs with the main grid and a 47.41%reduction in network loss costs,validating effective peak shaving and valley filling.The multi-timescale framework further enhances economic efficiency,with overall operating costs progressively decreasing by 3.91%(intraday)and 4.59%(real-time),and interaction costs further reduced by 5.34%and 9.25%,respectively.Moreover,the approach enhances system stability by effectively suppressing node voltage fluctuations and ensuring all voltages remain within safe operating limits during real-time operation.Therefore,the proposed approach achieves rational coordination of diverse resources,significantly improving the economic efficiency and stability of ADNs.展开更多
Theauthor proposes a dual layer source grid load storage collaborative planning model based on Benders decomposition to optimize the low-carbon and economic performance of the distribution network.The model plans the ...Theauthor proposes a dual layer source grid load storage collaborative planning model based on Benders decomposition to optimize the low-carbon and economic performance of the distribution network.The model plans the configuration of photovoltaic(3.8 MW),wind power(2.5 MW),energy storage(2.2 MWh),and SVC(1.2 Mvar)through interaction between upper and lower layers,and modifies lines 2–3,8–9,etc.to improve transmission capacity and voltage stability.The author uses normal distribution and Monte Carlo method to model load uncertainty,and combines Weibull distribution to describe wind speed characteristics.Compared to the traditional three-layer model(TLM),Benders decomposition-based two-layer model(BLBD)has a 58.1%reduction in convergence time(5.36 vs.12.78 h),a 51.1%reduction in iteration times(23 vs.47 times),a 8.07%reduction in total cost(12.436 vs.13.528 million yuan),and a 9.62%reduction in carbon emissions(12,456 vs.13,782 t).After optimization,the peak valley difference decreased from4.1 to 2.9MW,the renewable energy consumption rate reached 93.4%,and the energy storage efficiency was 87.6%.Themodel has been validated in the IEEE 33 node system,demonstrating its superiority in terms of economy,low-carbon,and reliability.展开更多
The dense integration of residential distributed photovoltaic(PV)systems into three-phase,four-wire low-voltage(LV)distribution networks results in reverse power flow and three-phase imbalance,leading to voltage viola...The dense integration of residential distributed photovoltaic(PV)systems into three-phase,four-wire low-voltage(LV)distribution networks results in reverse power flow and three-phase imbalance,leading to voltage violations that hinder the growth of rural distributed PV systems.Traditional voltage droop-based control methods regulate PV power output solely based on local voltage measurements at the point of PV connection.Due to a lack of global coordination and optimization,their efficiency is often subpar.This paper presents a centralized coordinated active/reactive power control strategy for PV inverters in rural LV distribution feeders with high PV penetration.The strategy optimizes residential PV inverter reactive and active power control to enhance voltage quality.It uses sensitivity coefficients derived from the inverse Jacobian matrix to assign adjustment weights to individual PV units and iteratively optimize their power outputs.The control sequence prioritizes reactive power increases;if the coefficients are below average or the inverters reach capacity,active power is curtailed until voltage issues are resolved.A simulation based on a real 37-node rural distribution network shows that the proposed method significantly reduces PV curtailment.Typical daily results indicate a curtailment rate of 1.47%,which is significantly lower than the 15.4%observed with the voltage droop-based control method.The total daily PV power output(measured every 15 min)increases from 5.55 to 6.41 MW,improving PV hosting capacity.展开更多
Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the...Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the coordination with virtual power plants(VPPs).The proposed strategy improves systemflexibility and responsiveness by optimizing the power adjustment of flexible resources.In the proposed strategy,theGaussian Process Regression(GPR)is firstly employed to determine the adjustable range of aggregated power within the VPP,facilitating an assessment of its potential contribution to power supply support.Then,an optimal dispatch model based on a leader-follower game is developed to maximize the benefits of the VPP and flexible resources while guaranteeing the power balance at the same time.To solve the proposed optimal dispatch model efficiently,the constraints of the problem are reformulated and resolved using the Karush-Kuhn-Tucker(KKT)optimality conditions and linear programming duality theorem.The effectiveness of the strategy is illustrated through a detailed case study.展开更多
Smelting with oxygen bottom blowing is one of the main methods used in the frame of copper pyrometallurgy.With this approach,feed materials and oxygen-enriched air are introduced in reversed order to enhance multiphas...Smelting with oxygen bottom blowing is one of the main methods used in the frame of copper pyrometallurgy.With this approach,feed materials and oxygen-enriched air are introduced in reversed order to enhance multiphaseflow within the furnace.Understanding the flow structure and temperature distribution in this setup is crucial foroptimizing production.In this study,gas-liquid interactions,and temperature profiles under varying air-injectionconditions are examined by means of numerical simulation for a 3.2 m×20 m furnace.The results indicate that thehigh-velocity regions are essentially distributed near the lance within the reaction region and the flue gas outlet,while low-velocity regions are located close to the furnace walls on both side of the reaction region.Dead regionsappear in the sedimentation region,with gas velocities surpassing those of the molten phase.As the injection rateincreases from 0.50 to 0.80 Nm3/s,the stabilization time of the average liquid surface velocity decreases from 2.6 sto 1.9 s,exhibiting a similar trend to the gas holdup.During stabilization,the average liquid surface velocity risesfrom 0.505 to 0.702 m/s.The average turbulent kinetic energy(TKE)of the fluid in the molten bath increases from0.095 to 0.162 m^(2)/s^(2).The proportion of the area distribution with TKE greater than 0.10 m^(2)/s^(2) and the gas holdupat steady state both rise with an increase in the injection quantity.The maximum splashing height of the melt growsfrom approximately 0.756 to 1.154 m,with the affected area expanding from 14.239 to 20.498 m^(2).Under differentworking conditions with varying injection quantities,the average temperature changes in melt zone and flue gaszone of the furnace are small.The temperature in the melt and in the flue-gas zone spans the interval 1200℃–1257℃,and 1073℃–1121℃,respectively.The temperature distribution of the melt and flue gas reveals a patterncharacterized by elevated temperatures in the reaction zone,gradually transitioning to lower temperatures in thesedimentation region.展开更多
Effective isolation between the cement sheath and the sandstone is crucial for the development and production of oil and gas wells in sandstone formations.In this study,a cement-sandstone composite(CSC)was prepared,an...Effective isolation between the cement sheath and the sandstone is crucial for the development and production of oil and gas wells in sandstone formations.In this study,a cement-sandstone composite(CSC)was prepared,and based onμ-CT three-dimensional reconstruction imaging and finite element analysis(FEA)techniques,the stress distribution and potential failure mechanism at the cement-sandstone bonding interface under axial loading were analyzed.The key findings are as follows:(1)stress concentrations are highly likely to form at the gap between the cement and sandstone interface and around interfacial voids,with Von Mises stress reaching critical levels of 18.0-20.0 MPa at these locations,significantly exceeding the stress magnitudes in well-bonded regions;(2)the phenomenon of local stress concentration driven by interfacial defects can be identified as the main basis for predicting damage location in interfacial debonding and continuous shear under axial load;(3)ensuring tight cementation at the cement-sandstone interface and minimizing interfacial voids are paramount for preventing stress-induced failure;(4)the critical Von Mises stress value of 20 MPa at the interface defect can be used as a benchmark for material selection and designed to ensure long-term integrity in oil and gas well applications subjected to similar axial loads.These findings contribute to a more accurate understanding of the failure mechanism of the cement-sandstone interface and to the precise design of material properties,thereby ensuring the long-term integrity of oil and gas well applications subjected to similar axial loads.展开更多
The evolution of misfit dislocation network at γ/γ' phase interfaces and the stress distribution characteristics of Ni-based single-crystal superalloys under different temperatures of 0, 100 and 300 K are studied b...The evolution of misfit dislocation network at γ/γ' phase interfaces and the stress distribution characteristics of Ni-based single-crystal superalloys under different temperatures of 0, 100 and 300 K are studied by molecular dynamics (MD) simulation. It was found that a closed three-dimensional misfit dislocation network appears on the γ/γ' phase interfaces, and the shape of the dislocation network is independent of the lattice mismatch. Under the influence of the temperature, the dislocation network gradually becomes irregular, a/2 [110] dislocations in the γ matrix phase emit and partly cut into the γ' phase with the increase in temperature. The dislocation evolution is related to the local stress field, a peak stress occurs at γ/γ' phase interface, and with the increase in temperature and relaxation times, the stress in the γ phase gradually increases, the number of dislocations in the γ phase increases and cuts into γ' phase from the interfaces where dislocation network is damaged. The results provide important information for understanding the temperature dependence of the dislocation evolution and mechanical properties of Ni-based single-crystal superalloys.展开更多
In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of ...In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of rural power distribution lines voltage is analyzed. The real rural power distribution network simulation model is established by Power System Power System Analysis Software Package (PSASP). Simulation analysis the effect of series capacitor compensation technology to improve the voltage quality of rural power distribution network, The simulation results show that the series capacitor compensation can effectively improve the voltage quality and reduce network losses and improve the transmission capacity of rural power distribution network.展开更多
The improved weighted-least-square model was used for state simulation of water distribution networks. And DFP algorithm was applied to get the model solution. In order to fit DFP algorithm,the initial model was trans...The improved weighted-least-square model was used for state simulation of water distribution networks. And DFP algorithm was applied to get the model solution. In order to fit DFP algorithm,the initial model was transformed into a non-constrained optimization problem using mass conservation. Then,through one dimensional optimization and scale matrix establishment,the feasible direction of iteration was obtained,and the values of state variables could be calculated. After several iterations,the optimal estimates of state variables were worked out and state simulation of water distribution networks was achieved as a result. A program of DFP algorithm is developed with Delphi 7 for verification. By running on a designed network,which is composed of 55 nodes,94 pipes and 40 loops,it is proved that DFP algorithm can quickly get the convergence. After 36 iterations,the root mean square of all nodal head errors is reduced by 90.84% from 5.57 to 0.51 m,and the maximum error is only 1.30 m. Compared to Marquardt algorithm,the procedure of DFP algorithm is more stable,and the initial values have less influences on calculation accuracy. Therefore,DFP algorithm can be used for real-time simulation of water distribution networks.展开更多
This paper proposes to use the power system simulation software CYME to plan, model and simulate for an actual distribution network for improving the reliability and efficiency, enhancing the efficiency and capacity, ...This paper proposes to use the power system simulation software CYME to plan, model and simulate for an actual distribution network for improving the reliability and efficiency, enhancing the efficiency and capacity, simulating the abnormal condition of distribution network, and presenting operation program of safe, reliable and having simulation record statements. The modeling simulation results show that the software module has lots of advantages including high accuracy, ideal reliability, powerful practicality in simulation and analysis of distribution network, it only need to create once model, the model can sufficiently satisfy multifarious types of simulation analysis required for the distribution network planning.展开更多
Based on the computational fluid dynamics (CFD) method, a quenching tank with two agitator systems and two flow-equilibrating devices was selected to simulate flow distribution using Fluent software. A numerical exa...Based on the computational fluid dynamics (CFD) method, a quenching tank with two agitator systems and two flow-equilibrating devices was selected to simulate flow distribution using Fluent software. A numerical example was used to testify the validity of the quenching tank model. In order to take tank parameters (agitation speed, position of directional flow baffle and coordinate position in quench zone) into account, an approach that combines the artificial neural network (ANN) with CFD method was developed to study the flow distribution in the quenching tank. The flow rate of the quenching medium shows a very good agreement between the ANN predicted results and the Fluent simulated data. Methods for the optimal design of the quenching tank can be used as technical support for industrial production.展开更多
An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature...An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature field model in cylindrical coordinates is developed. In the model, we considered general heat conduction as well as the heat convection due to fluid flow from porous formation to the borehole. We also take into account the fluid velocity variation in the wellbore due to multiple pay zones. We present coupled boundary conditions at the interfaces between the wellbore and adjacent formation, the wellbore and pay zone, and the pay zone and adjacent formation. Finally, an alternating direction implicit difference method (ADI) is used to solve the temperature model for the downhole temperature distribution. The comparison of modeled temperature curve with actual temperature log indicates that simulation result is in general quite similar to the actual temperature log. We found that the total production rate, production time, porosity, thickness of pay zones, and geothermal gradient, all have effects on the downhole temperature distribution.展开更多
We built a three-dimensional irregular network model which can adequately describe reservoir rock pore-throat structures. We carried out numerical simulations to study the NMR T2 distribution of water-saturated rocks....We built a three-dimensional irregular network model which can adequately describe reservoir rock pore-throat structures. We carried out numerical simulations to study the NMR T2 distribution of water-saturated rocks. The results indicate that there is a good correlation between T2 distribution and the pore radius frequency histogram. The total T2 distribution can be partitioned into pore body and pore throat parts. The effect of parameters including throat radius, pore-throat ratio, and coordination number of the micro- pore structure on the T2 distribution can be evaluated individually. The result indicates that: 1 ) with the increase of the pore throat radius, the T2 distribution moves toward longer relaxation times and its peak intensity increases; 2) with the increase of the pore-throat ratio, the T2 distribution moves towards longer T2 with the peak intensity increasing and the overlap between pore body T2 and pore throat T2 decreasing; 3) With the increase of connectivity, the short T2 component increases and peak signal intensity decreases slightly.展开更多
Based on the convection and diffusion mechanisms of radon migration, in this paper we deduce the two-dimensional differential equation for radon transportation in the overburden above active fault zones with an unlimi...Based on the convection and diffusion mechanisms of radon migration, in this paper we deduce the two-dimensional differential equation for radon transportation in the overburden above active fault zones with an unlimited extension along the strike. Making use of the finite difference method, the radon concentration distribution in the overburden above active faults is calculated and modeled. The active fault zone parameters, such as the depth and the width of the fault zone, and the value of radon concentration, can be inverted from the measured radon concentration curve. These realize quantitative interpretation for radon concentration anomalies. The inversion results are in good agreement with the actual fault zone parameters.展开更多
With the growing complexity and decentralization of network systems,the attack surface has expanded,which has led to greater concerns over network threats.In this context,artificial intelligence(AI)-based network intr...With the growing complexity and decentralization of network systems,the attack surface has expanded,which has led to greater concerns over network threats.In this context,artificial intelligence(AI)-based network intrusion detection systems(NIDS)have been extensively studied,and recent efforts have shifted toward integrating distributed learning to enable intelligent and scalable detection mechanisms.However,most existing works focus on individual distributed learning frameworks,and there is a lack of systematic evaluations that compare different algorithms under consistent conditions.In this paper,we present a comprehensive evaluation of representative distributed learning frameworks—Federated Learning(FL),Split Learning(SL),hybrid collaborative learning(SFL),and fully distributed learning—in the context of AI-driven NIDS.Using recent benchmark intrusion detection datasets,a unified model backbone,and controlled distributed scenarios,we assess these frameworks across multiple criteria,including detection performance,communication cost,computational efficiency,and convergence behavior.Our findings highlight distinct trade-offs among the distributed learning frameworks,demonstrating that the optimal choice depends strongly on systemconstraints such as bandwidth availability,node resources,and data distribution.This work provides the first holistic analysis of distributed learning approaches for AI-driven NIDS and offers practical guidelines for designing secure and efficient intrusion detection systems in decentralized environments.展开更多
Resilient smart urban water distribution networks are essential to ensure smooth urban operation and maintain daily water services.However,the dynamics and complexity of smart water distribution networks make its re-s...Resilient smart urban water distribution networks are essential to ensure smooth urban operation and maintain daily water services.However,the dynamics and complexity of smart water distribution networks make its re-silience study face many challenges.The introduction of digital twin technology provides an innovative solution for the resilience study of smart water distribution networks,which can more effectively support the network’s real-time monitoring and intelligent control.This paper proposes a digital twin architecture of smart water dis-tribution networks,laying the foundation for the resilience assessment of water distribution networks.Based on this,a performance evaluation model based on user satisfaction is proposed,which can more intuitively and effectively reflect the performance of urban water supply services.Meanwhile,we propose a method to quantify the importance of water distribution pipes’residual resilience,considering the time value to optimize the re-covery sequence of failed pipes and develop targeted preventive maintenance strategies.Finally,to validate the effectiveness of the proposed method,this paper applies it to a water distribution network.The results show that the proposed method can significantly improve the resilience and enhance the overall resilience of smart urban water distribution networks.展开更多
The stochastic extended finite-fault simulation method(EXSIM)is a widely used tool in seismological research,with applications in ground motion prediction and simulation,seismic hazard analysis,and engineering studies...The stochastic extended finite-fault simulation method(EXSIM)is a widely used tool in seismological research,with applications in ground motion prediction and simulation,seismic hazard analysis,and engineering studies.However,recent studies have revealed a significant limitation:EXSIM tends to overpredict ground motions in the low-to-intermediate frequency range,particularly for large thrust earthquakes that are often characterized by a double-corner-frequency source model.To address this issue and enhance simulation accuracy,this study introduces two key improvements:(1)a novel asperity-distributed stress-drop composite fault model and(2)a hybrid application of EXSIM with the composite fault model.The proposed method is validated through its application to the 2013 M_(w)6.7 Lushan earthquake that occurred in China and six thrust earthquakes with an M_(w)≥6.5 in Japan.By comparing the simulated ground motions with recorded data,the results demonstrate that the improved method achieves consistent accuracy across the high-and low-frequency spectrum(combined goodness-of-fit:CGOF<0.35).This study significantly broadens the applicability of stochastic finite-fault simulations,enabling more reliable predictions for a wider range of seismic scenarios,including complex thrust faulting events.展开更多
Distribution transformers play a vital role in power distribution systems,and their reliable operation is crucial for grid stability.This study presents a simulation-based framework for active fault diagnosis and earl...Distribution transformers play a vital role in power distribution systems,and their reliable operation is crucial for grid stability.This study presents a simulation-based framework for active fault diagnosis and early warning of distribution transformers,integrating Sample Ensemble Learning(SEL)with a Self-Optimizing Support Vector Machine(SO-SVM).The SEL technique enhances data diversity and mitigates class imbalance,while SO-SVM adaptively tunes its hyperparameters to improve classification accuracy.A comprehensive transformer model was developed in MATLAB/Simulink to simulate diverse fault scenarios,including inter-turn winding faults,core saturation,and thermal aging.Feature vectors were extracted from voltage,current,and temperature measurements to train and validate the proposed hybrid model.Quantitative analysis shows that the SEL–SO-SVM framework achieves a classification accuracy of 97.8%,a precision of 96.5%,and an F1-score of 97.2%.Beyond classification,the model effectively identified incipient faults,providing an early warning lead time of up to 2.5 s before significant deviations in operational parameters.This predictive capability underscores its potential for preventing catastrophic transformer failures and enabling timely maintenance actions.The proposed approach demonstrates strong applicability for enhancing the reliability and operational safety of distribution transformers in simulated environments,offering a promising foundation for future real-time and field-level implementations.展开更多
Severe ground-level ozone(O_(3))pollution over major Chinese cities has become one of the most challenging problems,which have deleterious effects on human health and the sustainability of society.This study explored ...Severe ground-level ozone(O_(3))pollution over major Chinese cities has become one of the most challenging problems,which have deleterious effects on human health and the sustainability of society.This study explored the spatiotemporal distribution characteristics of ground-level O_(3) and its precursors based on conventional pollutant and meteorological monitoring data in Zhejiang Province from 2016 to 2021.Then,a high-performance convolutional neural network(CNN)model was established by expanding the moment and the concentration variations to general factors.Finally,the response mechanism of O_(3) to the variation with crucial influencing factors is explored by controlling variables and interpolating target variables.The results indicated that the annual average MDA8-90th concentrations in Zhejiang Province are higher in the northern and lower in the southern.When the wind direction(WD)ranges from east to southwest and the wind speed(WS)ranges between 2 and 3 m/sec,higher O_(3) concentration prone to occur.At different temperatures(T),the O_(3) concentration showed a trend of first increasing and subsequently decreasing with increasing NO_(2) concentration,peaks at the NO_(2) concentration around 0.02mg/m^(3).The sensitivity of NO_(2) to O_(3) formation is not easily affected by temperature,barometric pressure and dew point temperature.Additionally,there is a minimum IRNO_(2) at each temperature when the NO_(2) concentration is 0.03 mg/m^(3),and this minimum IRNO_(2) decreases with increasing temperature.The study explores the response mechanism of O_(3) with the change of driving variables,which can provide a scientific foundation and methodological support for the targeted management of O_(3) pollution.展开更多
文摘In modern ZnO varistors,traditional aging mechanisms based on increased power consumption are no longer relevant due to reduced power consumption during DC aging.Prolonged exposure to both AC and DC voltages results in increased leakage current,decreased breakdown voltage,and lower nonlinearity,ultimately compromising their protective performance.To investigate the evolution in electrical properties during DC aging,this work developed a finite element model based on Voronoi networks and conducted accelerated aging tests on commercial varistors.Throughout the aging process,current-voltage characteristics and Schottky barrier parameters were measured and analyzed.The results indicate that when subjected to constant voltage,current flows through regions with larger grain sizes,forming discharge channels.As aging progresses,the current focus increases on these channels,leading to a decline in the varistor’s overall performance.Furthermore,analysis of the Schottky barrier parameters shows that the changes in electrical performance during aging are non-monotonic.These findings offer theoretical support for understanding the aging mechanisms and condition assessment of modern stable ZnO varistors.
基金supported by Integrated Distribution Network Planning and Operational Enhancement Using Flexibility Domains Under Deep Human-Vehicle-Charger-Road-Grid Coupling(U22B20105).
文摘Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energy and load forecasting in active distribution networks(ADN),this paper proposes a multi-timescale coordinated optimal dispatch strategy that incorporates TSEH clusters.It utilizes the thermal storage characteristics and short-term regulation capabilities of TSEH,along with the rapid and gradual response characteristics of resources in active distribution grids,to develop a coordinated optimization dispatch mechanism for day-ahead,intraday,and real-time stages.It provides a coordinated optimized dispatch technique across several timescales for active distribution grids,taking into account the integration of TSEH clusters.The proposed method is validated on a modified IEEE 33-node system.Simulation results demonstrate that the participation of TSEH in collaborative optimization significantly reduces the total system operating cost by 8.71%compared to the scenario without TSEH.This cost reduction is attributed to a 10.84%decrease in interaction costs with the main grid and a 47.41%reduction in network loss costs,validating effective peak shaving and valley filling.The multi-timescale framework further enhances economic efficiency,with overall operating costs progressively decreasing by 3.91%(intraday)and 4.59%(real-time),and interaction costs further reduced by 5.34%and 9.25%,respectively.Moreover,the approach enhances system stability by effectively suppressing node voltage fluctuations and ensuring all voltages remain within safe operating limits during real-time operation.Therefore,the proposed approach achieves rational coordination of diverse resources,significantly improving the economic efficiency and stability of ADNs.
文摘Theauthor proposes a dual layer source grid load storage collaborative planning model based on Benders decomposition to optimize the low-carbon and economic performance of the distribution network.The model plans the configuration of photovoltaic(3.8 MW),wind power(2.5 MW),energy storage(2.2 MWh),and SVC(1.2 Mvar)through interaction between upper and lower layers,and modifies lines 2–3,8–9,etc.to improve transmission capacity and voltage stability.The author uses normal distribution and Monte Carlo method to model load uncertainty,and combines Weibull distribution to describe wind speed characteristics.Compared to the traditional three-layer model(TLM),Benders decomposition-based two-layer model(BLBD)has a 58.1%reduction in convergence time(5.36 vs.12.78 h),a 51.1%reduction in iteration times(23 vs.47 times),a 8.07%reduction in total cost(12.436 vs.13.528 million yuan),and a 9.62%reduction in carbon emissions(12,456 vs.13,782 t).After optimization,the peak valley difference decreased from4.1 to 2.9MW,the renewable energy consumption rate reached 93.4%,and the energy storage efficiency was 87.6%.Themodel has been validated in the IEEE 33 node system,demonstrating its superiority in terms of economy,low-carbon,and reliability.
基金supported by the Provincial Industrial Science and Technology Project of State Grid Jiangsu Electric Power Co.,Ltd.of China,grant number JC2024118.
文摘The dense integration of residential distributed photovoltaic(PV)systems into three-phase,four-wire low-voltage(LV)distribution networks results in reverse power flow and three-phase imbalance,leading to voltage violations that hinder the growth of rural distributed PV systems.Traditional voltage droop-based control methods regulate PV power output solely based on local voltage measurements at the point of PV connection.Due to a lack of global coordination and optimization,their efficiency is often subpar.This paper presents a centralized coordinated active/reactive power control strategy for PV inverters in rural LV distribution feeders with high PV penetration.The strategy optimizes residential PV inverter reactive and active power control to enhance voltage quality.It uses sensitivity coefficients derived from the inverse Jacobian matrix to assign adjustment weights to individual PV units and iteratively optimize their power outputs.The control sequence prioritizes reactive power increases;if the coefficients are below average or the inverters reach capacity,active power is curtailed until voltage issues are resolved.A simulation based on a real 37-node rural distribution network shows that the proposed method significantly reduces PV curtailment.Typical daily results indicate a curtailment rate of 1.47%,which is significantly lower than the 15.4%observed with the voltage droop-based control method.The total daily PV power output(measured every 15 min)increases from 5.55 to 6.41 MW,improving PV hosting capacity.
基金supported by the Science and Technology Project of Sichuan Electric Power Company“Power Supply Guarantee Strategy for Urban Distribution Networks Considering Coordination with Virtual Power Plant during Extreme Weather Event”(No.521920230003).
文摘Ensuring reliable power supply in urban distribution networks is a complex and critical task.To address the increased demand during extreme scenarios,this paper proposes an optimal dispatch strategy that considers the coordination with virtual power plants(VPPs).The proposed strategy improves systemflexibility and responsiveness by optimizing the power adjustment of flexible resources.In the proposed strategy,theGaussian Process Regression(GPR)is firstly employed to determine the adjustable range of aggregated power within the VPP,facilitating an assessment of its potential contribution to power supply support.Then,an optimal dispatch model based on a leader-follower game is developed to maximize the benefits of the VPP and flexible resources while guaranteeing the power balance at the same time.To solve the proposed optimal dispatch model efficiently,the constraints of the problem are reformulated and resolved using the Karush-Kuhn-Tucker(KKT)optimality conditions and linear programming duality theorem.The effectiveness of the strategy is illustrated through a detailed case study.
基金Supported by Yunnan Fundamental Research Projects(Nos.202301AT070469,202301AT070275)Supported by Yunnan Major Scientific and Technological Projects(No.202202AG050002).
文摘Smelting with oxygen bottom blowing is one of the main methods used in the frame of copper pyrometallurgy.With this approach,feed materials and oxygen-enriched air are introduced in reversed order to enhance multiphaseflow within the furnace.Understanding the flow structure and temperature distribution in this setup is crucial foroptimizing production.In this study,gas-liquid interactions,and temperature profiles under varying air-injectionconditions are examined by means of numerical simulation for a 3.2 m×20 m furnace.The results indicate that thehigh-velocity regions are essentially distributed near the lance within the reaction region and the flue gas outlet,while low-velocity regions are located close to the furnace walls on both side of the reaction region.Dead regionsappear in the sedimentation region,with gas velocities surpassing those of the molten phase.As the injection rateincreases from 0.50 to 0.80 Nm3/s,the stabilization time of the average liquid surface velocity decreases from 2.6 sto 1.9 s,exhibiting a similar trend to the gas holdup.During stabilization,the average liquid surface velocity risesfrom 0.505 to 0.702 m/s.The average turbulent kinetic energy(TKE)of the fluid in the molten bath increases from0.095 to 0.162 m^(2)/s^(2).The proportion of the area distribution with TKE greater than 0.10 m^(2)/s^(2) and the gas holdupat steady state both rise with an increase in the injection quantity.The maximum splashing height of the melt growsfrom approximately 0.756 to 1.154 m,with the affected area expanding from 14.239 to 20.498 m^(2).Under differentworking conditions with varying injection quantities,the average temperature changes in melt zone and flue gaszone of the furnace are small.The temperature in the melt and in the flue-gas zone spans the interval 1200℃–1257℃,and 1073℃–1121℃,respectively.The temperature distribution of the melt and flue gas reveals a patterncharacterized by elevated temperatures in the reaction zone,gradually transitioning to lower temperatures in thesedimentation region.
基金supported by the National Natural Science Foundation of China(No.52274026)the National Key Research and Development Program(No.2022YFC2806504)the CNOOC Research Project(No.KJGG-2022-17-04 and NO.KJGG-2022-17-05).
文摘Effective isolation between the cement sheath and the sandstone is crucial for the development and production of oil and gas wells in sandstone formations.In this study,a cement-sandstone composite(CSC)was prepared,and based onμ-CT three-dimensional reconstruction imaging and finite element analysis(FEA)techniques,the stress distribution and potential failure mechanism at the cement-sandstone bonding interface under axial loading were analyzed.The key findings are as follows:(1)stress concentrations are highly likely to form at the gap between the cement and sandstone interface and around interfacial voids,with Von Mises stress reaching critical levels of 18.0-20.0 MPa at these locations,significantly exceeding the stress magnitudes in well-bonded regions;(2)the phenomenon of local stress concentration driven by interfacial defects can be identified as the main basis for predicting damage location in interfacial debonding and continuous shear under axial load;(3)ensuring tight cementation at the cement-sandstone interface and minimizing interfacial voids are paramount for preventing stress-induced failure;(4)the critical Von Mises stress value of 20 MPa at the interface defect can be used as a benchmark for material selection and designed to ensure long-term integrity in oil and gas well applications subjected to similar axial loads.These findings contribute to a more accurate understanding of the failure mechanism of the cement-sandstone interface and to the precise design of material properties,thereby ensuring the long-term integrity of oil and gas well applications subjected to similar axial loads.
基金financially supported by the National Natural Science Foundation of China(Nos.11102139 and 11472195)the Natural Science Foundation of Hubei Province of China(No.2014CFB713)
文摘The evolution of misfit dislocation network at γ/γ' phase interfaces and the stress distribution characteristics of Ni-based single-crystal superalloys under different temperatures of 0, 100 and 300 K are studied by molecular dynamics (MD) simulation. It was found that a closed three-dimensional misfit dislocation network appears on the γ/γ' phase interfaces, and the shape of the dislocation network is independent of the lattice mismatch. Under the influence of the temperature, the dislocation network gradually becomes irregular, a/2 [110] dislocations in the γ matrix phase emit and partly cut into the γ' phase with the increase in temperature. The dislocation evolution is related to the local stress field, a peak stress occurs at γ/γ' phase interface, and with the increase in temperature and relaxation times, the stress in the γ phase gradually increases, the number of dislocations in the γ phase increases and cuts into γ' phase from the interfaces where dislocation network is damaged. The results provide important information for understanding the temperature dependence of the dislocation evolution and mechanical properties of Ni-based single-crystal superalloys.
文摘In order to improve the voltage quality of rural power distribution network, the series capacitor in distribution lines is proposed. The principle of series capacitor compensation technology to improve the quality of rural power distribution lines voltage is analyzed. The real rural power distribution network simulation model is established by Power System Power System Analysis Software Package (PSASP). Simulation analysis the effect of series capacitor compensation technology to improve the voltage quality of rural power distribution network, The simulation results show that the series capacitor compensation can effectively improve the voltage quality and reduce network losses and improve the transmission capacity of rural power distribution network.
基金Project(IRT0853) supported by Changjiang Scholars and Innovative Research Team in UniversityProject(DB03086) supported by Talents Fund of Xi’an University of Architecture and TechnologyProject(50978213) supported by National Natural Science Foundation
文摘The improved weighted-least-square model was used for state simulation of water distribution networks. And DFP algorithm was applied to get the model solution. In order to fit DFP algorithm,the initial model was transformed into a non-constrained optimization problem using mass conservation. Then,through one dimensional optimization and scale matrix establishment,the feasible direction of iteration was obtained,and the values of state variables could be calculated. After several iterations,the optimal estimates of state variables were worked out and state simulation of water distribution networks was achieved as a result. A program of DFP algorithm is developed with Delphi 7 for verification. By running on a designed network,which is composed of 55 nodes,94 pipes and 40 loops,it is proved that DFP algorithm can quickly get the convergence. After 36 iterations,the root mean square of all nodal head errors is reduced by 90.84% from 5.57 to 0.51 m,and the maximum error is only 1.30 m. Compared to Marquardt algorithm,the procedure of DFP algorithm is more stable,and the initial values have less influences on calculation accuracy. Therefore,DFP algorithm can be used for real-time simulation of water distribution networks.
文摘This paper proposes to use the power system simulation software CYME to plan, model and simulate for an actual distribution network for improving the reliability and efficiency, enhancing the efficiency and capacity, simulating the abnormal condition of distribution network, and presenting operation program of safe, reliable and having simulation record statements. The modeling simulation results show that the software module has lots of advantages including high accuracy, ideal reliability, powerful practicality in simulation and analysis of distribution network, it only need to create once model, the model can sufficiently satisfy multifarious types of simulation analysis required for the distribution network planning.
文摘Based on the computational fluid dynamics (CFD) method, a quenching tank with two agitator systems and two flow-equilibrating devices was selected to simulate flow distribution using Fluent software. A numerical example was used to testify the validity of the quenching tank model. In order to take tank parameters (agitation speed, position of directional flow baffle and coordinate position in quench zone) into account, an approach that combines the artificial neural network (ANN) with CFD method was developed to study the flow distribution in the quenching tank. The flow rate of the quenching medium shows a very good agreement between the ANN predicted results and the Fluent simulated data. Methods for the optimal design of the quenching tank can be used as technical support for industrial production.
基金sponsored by the National Nature Science Foundation of China (Grant No. 40830424).
文摘An improved numerical simulation method is presented to calculate the downhole temperature distribution for multiple pay zones in producing oil wells. Based on hydrodynamics and heat transfer theory, a 2-D temperature field model in cylindrical coordinates is developed. In the model, we considered general heat conduction as well as the heat convection due to fluid flow from porous formation to the borehole. We also take into account the fluid velocity variation in the wellbore due to multiple pay zones. We present coupled boundary conditions at the interfaces between the wellbore and adjacent formation, the wellbore and pay zone, and the pay zone and adjacent formation. Finally, an alternating direction implicit difference method (ADI) is used to solve the temperature model for the downhole temperature distribution. The comparison of modeled temperature curve with actual temperature log indicates that simulation result is in general quite similar to the actual temperature log. We found that the total production rate, production time, porosity, thickness of pay zones, and geothermal gradient, all have effects on the downhole temperature distribution.
文摘We built a three-dimensional irregular network model which can adequately describe reservoir rock pore-throat structures. We carried out numerical simulations to study the NMR T2 distribution of water-saturated rocks. The results indicate that there is a good correlation between T2 distribution and the pore radius frequency histogram. The total T2 distribution can be partitioned into pore body and pore throat parts. The effect of parameters including throat radius, pore-throat ratio, and coordination number of the micro- pore structure on the T2 distribution can be evaluated individually. The result indicates that: 1 ) with the increase of the pore throat radius, the T2 distribution moves toward longer relaxation times and its peak intensity increases; 2) with the increase of the pore-throat ratio, the T2 distribution moves towards longer T2 with the peak intensity increasing and the overlap between pore body T2 and pore throat T2 decreasing; 3) With the increase of connectivity, the short T2 component increases and peak signal intensity decreases slightly.
文摘Based on the convection and diffusion mechanisms of radon migration, in this paper we deduce the two-dimensional differential equation for radon transportation in the overburden above active fault zones with an unlimited extension along the strike. Making use of the finite difference method, the radon concentration distribution in the overburden above active faults is calculated and modeled. The active fault zone parameters, such as the depth and the width of the fault zone, and the value of radon concentration, can be inverted from the measured radon concentration curve. These realize quantitative interpretation for radon concentration anomalies. The inversion results are in good agreement with the actual fault zone parameters.
基金supported by the Research year project of the KongjuNational University in 2025 and the Institute of Information&Communications Technology Planning&Evaluation(IITP)grant funded by the Korea government(MSIT)(No.RS-2024-00444170,Research and International Collaboration on Trust Model-Based Intelligent Incident Response Technologies in 6G Open Network Environment).
文摘With the growing complexity and decentralization of network systems,the attack surface has expanded,which has led to greater concerns over network threats.In this context,artificial intelligence(AI)-based network intrusion detection systems(NIDS)have been extensively studied,and recent efforts have shifted toward integrating distributed learning to enable intelligent and scalable detection mechanisms.However,most existing works focus on individual distributed learning frameworks,and there is a lack of systematic evaluations that compare different algorithms under consistent conditions.In this paper,we present a comprehensive evaluation of representative distributed learning frameworks—Federated Learning(FL),Split Learning(SL),hybrid collaborative learning(SFL),and fully distributed learning—in the context of AI-driven NIDS.Using recent benchmark intrusion detection datasets,a unified model backbone,and controlled distributed scenarios,we assess these frameworks across multiple criteria,including detection performance,communication cost,computational efficiency,and convergence behavior.Our findings highlight distinct trade-offs among the distributed learning frameworks,demonstrating that the optimal choice depends strongly on systemconstraints such as bandwidth availability,node resources,and data distribution.This work provides the first holistic analysis of distributed learning approaches for AI-driven NIDS and offers practical guidelines for designing secure and efficient intrusion detection systems in decentralized environments.
基金the financial support for this research from the Program for the Program for young backbone teachers in Universities of Henan Province(No.2021GGJS007).
文摘Resilient smart urban water distribution networks are essential to ensure smooth urban operation and maintain daily water services.However,the dynamics and complexity of smart water distribution networks make its re-silience study face many challenges.The introduction of digital twin technology provides an innovative solution for the resilience study of smart water distribution networks,which can more effectively support the network’s real-time monitoring and intelligent control.This paper proposes a digital twin architecture of smart water dis-tribution networks,laying the foundation for the resilience assessment of water distribution networks.Based on this,a performance evaluation model based on user satisfaction is proposed,which can more intuitively and effectively reflect the performance of urban water supply services.Meanwhile,we propose a method to quantify the importance of water distribution pipes’residual resilience,considering the time value to optimize the re-covery sequence of failed pipes and develop targeted preventive maintenance strategies.Finally,to validate the effectiveness of the proposed method,this paper applies it to a water distribution network.The results show that the proposed method can significantly improve the resilience and enhance the overall resilience of smart urban water distribution networks.
基金National Key Research and Development Program of China under Grant No.2022YFC3003601National Natural Science Foundation of China under Grant No.52478570+1 种基金Heilongjiang Provincial Natural Science Foundation Outstanding Youth Program under Grant No.J020245002the Key Research and Development Program of Xinjiang Production and Construction Corps under Grant No.2024AB077。
文摘The stochastic extended finite-fault simulation method(EXSIM)is a widely used tool in seismological research,with applications in ground motion prediction and simulation,seismic hazard analysis,and engineering studies.However,recent studies have revealed a significant limitation:EXSIM tends to overpredict ground motions in the low-to-intermediate frequency range,particularly for large thrust earthquakes that are often characterized by a double-corner-frequency source model.To address this issue and enhance simulation accuracy,this study introduces two key improvements:(1)a novel asperity-distributed stress-drop composite fault model and(2)a hybrid application of EXSIM with the composite fault model.The proposed method is validated through its application to the 2013 M_(w)6.7 Lushan earthquake that occurred in China and six thrust earthquakes with an M_(w)≥6.5 in Japan.By comparing the simulated ground motions with recorded data,the results demonstrate that the improved method achieves consistent accuracy across the high-and low-frequency spectrum(combined goodness-of-fit:CGOF<0.35).This study significantly broadens the applicability of stochastic finite-fault simulations,enabling more reliable predictions for a wider range of seismic scenarios,including complex thrust faulting events.
文摘Distribution transformers play a vital role in power distribution systems,and their reliable operation is crucial for grid stability.This study presents a simulation-based framework for active fault diagnosis and early warning of distribution transformers,integrating Sample Ensemble Learning(SEL)with a Self-Optimizing Support Vector Machine(SO-SVM).The SEL technique enhances data diversity and mitigates class imbalance,while SO-SVM adaptively tunes its hyperparameters to improve classification accuracy.A comprehensive transformer model was developed in MATLAB/Simulink to simulate diverse fault scenarios,including inter-turn winding faults,core saturation,and thermal aging.Feature vectors were extracted from voltage,current,and temperature measurements to train and validate the proposed hybrid model.Quantitative analysis shows that the SEL–SO-SVM framework achieves a classification accuracy of 97.8%,a precision of 96.5%,and an F1-score of 97.2%.Beyond classification,the model effectively identified incipient faults,providing an early warning lead time of up to 2.5 s before significant deviations in operational parameters.This predictive capability underscores its potential for preventing catastrophic transformer failures and enabling timely maintenance actions.The proposed approach demonstrates strong applicability for enhancing the reliability and operational safety of distribution transformers in simulated environments,offering a promising foundation for future real-time and field-level implementations.
基金supported by the National Key Research and Development Program of China (Nos.2022YFC3702000 and 2022YFC3703500)the Key R&D Project of Zhejiang Province (No.2022C03146).
文摘Severe ground-level ozone(O_(3))pollution over major Chinese cities has become one of the most challenging problems,which have deleterious effects on human health and the sustainability of society.This study explored the spatiotemporal distribution characteristics of ground-level O_(3) and its precursors based on conventional pollutant and meteorological monitoring data in Zhejiang Province from 2016 to 2021.Then,a high-performance convolutional neural network(CNN)model was established by expanding the moment and the concentration variations to general factors.Finally,the response mechanism of O_(3) to the variation with crucial influencing factors is explored by controlling variables and interpolating target variables.The results indicated that the annual average MDA8-90th concentrations in Zhejiang Province are higher in the northern and lower in the southern.When the wind direction(WD)ranges from east to southwest and the wind speed(WS)ranges between 2 and 3 m/sec,higher O_(3) concentration prone to occur.At different temperatures(T),the O_(3) concentration showed a trend of first increasing and subsequently decreasing with increasing NO_(2) concentration,peaks at the NO_(2) concentration around 0.02mg/m^(3).The sensitivity of NO_(2) to O_(3) formation is not easily affected by temperature,barometric pressure and dew point temperature.Additionally,there is a minimum IRNO_(2) at each temperature when the NO_(2) concentration is 0.03 mg/m^(3),and this minimum IRNO_(2) decreases with increasing temperature.The study explores the response mechanism of O_(3) with the change of driving variables,which can provide a scientific foundation and methodological support for the targeted management of O_(3) pollution.