In order to study the differences in vertical component between onshore and offshore motions,the vertical-to-horizontal peak ground acceleration ratio(V/H PGA ratio) and vertical-to-horizontal response spectral ratio(...In order to study the differences in vertical component between onshore and offshore motions,the vertical-to-horizontal peak ground acceleration ratio(V/H PGA ratio) and vertical-to-horizontal response spectral ratio(V/H) were investigated using the ground motion recordings from the K-NET network and the seafloor earthquake measuring system(SEMS).The results indicate that the vertical component of offshore motions is lower than that of onshore motions.The V/H PGA ratio of acceleration time histories at offshore stations is about 50%of the ratio at onshore stations.The V/H for offshore ground motions is lower than that for onshore motions,especially for periods less than 0.8 s.Furthermore,based on the results in statistical analysis for offshore recordings in the K-NET,the simplified V/H design equations for offshore motions in minor and moderate earthquakes are proposed for seismic analysis of offshore structures.展开更多
1 Active Disturbance Rejection Control(ADRC):a brief survey Since its inception,Active Disturbance Rejection Control(ADRC)has re-centered feedback controller design around two fundamental ideas—along with a consequen...1 Active Disturbance Rejection Control(ADRC):a brief survey Since its inception,Active Disturbance Rejection Control(ADRC)has re-centered feedback controller design around two fundamental ideas—along with a consequential design simplification:real-time estimation and online cancellation of the“total disturbance”conceived as the lumped effect of unknown internal dynamics and external inputs.The simplified design then proceeds in a customary fashion for the ideally remaining system model,which is devoid of the total disturbance.展开更多
The Building Standard Law of Japan and related Enforcement Order and Notifications have been substantially revised since the year 2000 to introduce a performance-based regulatory and deregulation system for building c...The Building Standard Law of Japan and related Enforcement Order and Notifications have been substantially revised since the year 2000 to introduce a performance-based regulatory and deregulation system for building control systems. Up to then,time-history analyses were mandatory for isolated buildings and had to be specially approved by the Minster of the Ministry of Construction (MOC).Simplified design procedures based on the equivalent linear method for seismically isolated buildings have been issued as'Notification 2009-Structnral calculation procedure for buildings with seismic isolation'from MOC,and are now integrated into the Ministry of Land,Infrastructure,and Transportation (MLIT).Along with Notification 2009,'Notification 1446 of year 2000-Standard for specifications and test methods for seismic isolation devices'was also issued.Buildings with heights equal to or less than 60m and that are designed according to these Notifications,including base isolated buildings,only need approval from local building officials,and no longer require the special approval of the Minister of MLIT.This paper summarizes:1) some statistics related to buildings with seismic isolation completed up to the end of 2001; 2) simplified design procedures required by Notification 2009 of year 2000;and 3) performance of seismic isolation devices required by Notification 1446 of year 2000.展开更多
基金Project(2011CB013605)supported by the National Basic Research Development Program of China(973 Program)Projects(51178071,51008041)supported by the National Natural Science Foundation of ChinaProject(NCET-12-0751)supported by the New Century Excellent Talents Program in University of Ministry of Education of China
文摘In order to study the differences in vertical component between onshore and offshore motions,the vertical-to-horizontal peak ground acceleration ratio(V/H PGA ratio) and vertical-to-horizontal response spectral ratio(V/H) were investigated using the ground motion recordings from the K-NET network and the seafloor earthquake measuring system(SEMS).The results indicate that the vertical component of offshore motions is lower than that of onshore motions.The V/H PGA ratio of acceleration time histories at offshore stations is about 50%of the ratio at onshore stations.The V/H for offshore ground motions is lower than that for onshore motions,especially for periods less than 0.8 s.Furthermore,based on the results in statistical analysis for offshore recordings in the K-NET,the simplified V/H design equations for offshore motions in minor and moderate earthquakes are proposed for seismic analysis of offshore structures.
文摘1 Active Disturbance Rejection Control(ADRC):a brief survey Since its inception,Active Disturbance Rejection Control(ADRC)has re-centered feedback controller design around two fundamental ideas—along with a consequential design simplification:real-time estimation and online cancellation of the“total disturbance”conceived as the lumped effect of unknown internal dynamics and external inputs.The simplified design then proceeds in a customary fashion for the ideally remaining system model,which is devoid of the total disturbance.
文摘The Building Standard Law of Japan and related Enforcement Order and Notifications have been substantially revised since the year 2000 to introduce a performance-based regulatory and deregulation system for building control systems. Up to then,time-history analyses were mandatory for isolated buildings and had to be specially approved by the Minster of the Ministry of Construction (MOC).Simplified design procedures based on the equivalent linear method for seismically isolated buildings have been issued as'Notification 2009-Structnral calculation procedure for buildings with seismic isolation'from MOC,and are now integrated into the Ministry of Land,Infrastructure,and Transportation (MLIT).Along with Notification 2009,'Notification 1446 of year 2000-Standard for specifications and test methods for seismic isolation devices'was also issued.Buildings with heights equal to or less than 60m and that are designed according to these Notifications,including base isolated buildings,only need approval from local building officials,and no longer require the special approval of the Minister of MLIT.This paper summarizes:1) some statistics related to buildings with seismic isolation completed up to the end of 2001; 2) simplified design procedures required by Notification 2009 of year 2000;and 3) performance of seismic isolation devices required by Notification 1446 of year 2000.