Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy...Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a single Ir-192 brachytherapy source in Brachytherapy center by using MCNP5 Monte Carlo measurements. The room was based on the design specifications for the HDR 192 Ir treatment was modeled. The estimated dose rate range for HDR 192 Ir and public buildings is (0.45 - 0.64): (micro sivert) μSv/hour. Dose rates measured data for the current setup Brachytherapy HDR unit was approved and agreed quiet well with recommendation of International Atomic Energy Agency. The measured dose rate for public areas and controlled areas, compared with the reference value of 7.5 μSv/h and 0.5 μSv/h and concluded that we have enough shielding to the source but an over estimate with experimental measurements had been seen.展开更多
ITER blanket design has progressed significantly since 2001, which resulted in a reduction in cost and an increase in performance with respect to FDR 2001. One of the most important improvements is the new coolant flo...ITER blanket design has progressed significantly since 2001, which resulted in a reduction in cost and an increase in performance with respect to FDR 2001. One of the most important improvements is the new coolant flow configuration in the shield block ( SB ) . In the current design TM, the cooling circuit in the SB is a matrix of radial holes which are arranged in eight poloidal rows. The rows are fed in parallel by front headers and back drilled collectors, and merge in four couples through the front header. These four couples of rows are linked in series by transverse holes. In the current design, a special shape of flow driver is mounted inside the radial hole, and coolant flows through clearance between the driver and drilled radial hole, which allows achieving a high coolant velocity,展开更多
One of the most important safety features of nuclear facilities is the shielding material used to protect the operating personnel from radiation exposure. The most common materials used in radiation shielding are conc...One of the most important safety features of nuclear facilities is the shielding material used to protect the operating personnel from radiation exposure. The most common materials used in radiation shielding are concretes. In this study, a Monte Carlo N-Particle eXtended code is used to calculate the gamma-ray attenuation coefficients and dose rates for a new concrete material composed of MnFe_2O_4 nanoparticles, which is then compared with the theoretical and experimental results obtained for a SiO_2 nanoparticle concrete material. According to the results, the average relative differences between the simulations and the theoretical and experimental results for the linear attenuation coefficient(l) in the SiO_2 nanoparticle materials are 6.4% and 5.5%, respectively. By increasing the SiO_2 content up to 1.5% and the temperature of MnFe_2O_4 up to 673 K, l is increased for all energies. In addition, the photon dose rate decreases up to 9.2% and3.7% for MnFe_2O_4 and SiO_2 for gamma-ray energies of0.511 and 1.274 MeV, respectively. Therefore, it was concluded that the addition of SiO_2 and MnFe_2O_4 nanoparticles to concrete improves its nuclear properties and could lead to it being more useful in radiation shielding.展开更多
文摘Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a single Ir-192 brachytherapy source in Brachytherapy center by using MCNP5 Monte Carlo measurements. The room was based on the design specifications for the HDR 192 Ir treatment was modeled. The estimated dose rate range for HDR 192 Ir and public buildings is (0.45 - 0.64): (micro sivert) μSv/hour. Dose rates measured data for the current setup Brachytherapy HDR unit was approved and agreed quiet well with recommendation of International Atomic Energy Agency. The measured dose rate for public areas and controlled areas, compared with the reference value of 7.5 μSv/h and 0.5 μSv/h and concluded that we have enough shielding to the source but an over estimate with experimental measurements had been seen.
文摘ITER blanket design has progressed significantly since 2001, which resulted in a reduction in cost and an increase in performance with respect to FDR 2001. One of the most important improvements is the new coolant flow configuration in the shield block ( SB ) . In the current design TM, the cooling circuit in the SB is a matrix of radial holes which are arranged in eight poloidal rows. The rows are fed in parallel by front headers and back drilled collectors, and merge in four couples through the front header. These four couples of rows are linked in series by transverse holes. In the current design, a special shape of flow driver is mounted inside the radial hole, and coolant flows through clearance between the driver and drilled radial hole, which allows achieving a high coolant velocity,
文摘One of the most important safety features of nuclear facilities is the shielding material used to protect the operating personnel from radiation exposure. The most common materials used in radiation shielding are concretes. In this study, a Monte Carlo N-Particle eXtended code is used to calculate the gamma-ray attenuation coefficients and dose rates for a new concrete material composed of MnFe_2O_4 nanoparticles, which is then compared with the theoretical and experimental results obtained for a SiO_2 nanoparticle concrete material. According to the results, the average relative differences between the simulations and the theoretical and experimental results for the linear attenuation coefficient(l) in the SiO_2 nanoparticle materials are 6.4% and 5.5%, respectively. By increasing the SiO_2 content up to 1.5% and the temperature of MnFe_2O_4 up to 673 K, l is increased for all energies. In addition, the photon dose rate decreases up to 9.2% and3.7% for MnFe_2O_4 and SiO_2 for gamma-ray energies of0.511 and 1.274 MeV, respectively. Therefore, it was concluded that the addition of SiO_2 and MnFe_2O_4 nanoparticles to concrete improves its nuclear properties and could lead to it being more useful in radiation shielding.