期刊文献+
共找到9,374篇文章
< 1 2 250 >
每页显示 20 50 100
Researches on Low-Carbon Development Pathways for Provincial Power Systems from the Perspective of Carbon Emission Factor
1
作者 Yang Li Xianfu Gong +3 位作者 Sifan Chen Yi Lei Donghui Zhang Yue Xing 《Energy Engineering》 2026年第4期382-403,共22页
This paper develops an innovative computational model for assessing the Carbon Emission Factor(CEF)of provincial power systems that incorporates inter-provincial electricity transfers and hybrid generation portfolios ... This paper develops an innovative computational model for assessing the Carbon Emission Factor(CEF)of provincial power systems that incorporates inter-provincial electricity transfers and hybrid generation portfolios combining conventional and renewable sources.A key contribution lies in evaluating how deep regulation of thermal power plants influence the carbon intensity of coal-fired generation and coal-fired generation together with high penetration renewables.Furthermore,the study quantitatively analyzes the role of renewable energy consumption and the prospective application of Carbon Capture and Storage(CCS)in reducing system-wide CEF.Based on this framework,the paper proposes phased carbon emission targets for Guangdong’s power system for key milestone years(2030,2045,2060),along with targeted implementation strategies.Results demonstrate that in renewable-dominant systems,deep regulation of thermal units,load peak-shaving,and deployment of flexible resources such as energy storage are effective in cutting carbon intensity.To achieve the defined targets—0.367 kg/kWh by 2030,0.231 kg/kWh by 2045,and 0.032 kg/kWh by 2060—the following innovation-focused policy is recommended:in early stage,mainly on expansion of renewable capacity and inter-provincial transmission infrastructure along with energy storage deployment;in mid-term,mainly on enhancement of electricity market mechanisms to promote green power trading and demand-side flexibility;and in late-stage,mainly on systematic retirement of conventional coal assets coupled with large-scale CCS adoption and carbon sink mechanisms. 展开更多
关键词 Carbon emission factor power system renewable energy consumption thermal power flexibility CCS demand-side response
在线阅读 下载PDF
Research on Power Factor Improvement of a PM Vernier In-wheel Motor with Collaborative Design of PM and Armature Flux Linkage
2
作者 Zixuan Xiang Lei Peng +2 位作者 Xiaoyong Zhu Jiaqiang Wei Zhe Yue 《CES Transactions on Electrical Machines and Systems》 2026年第1期44-54,共11页
This paper proposes a collaborative design method for enhancing the power factor and torque of electric motors.First,the intrinsic relationship between flux linkage analysis of the permanent magnet(PM)and armature fie... This paper proposes a collaborative design method for enhancing the power factor and torque of electric motors.First,the intrinsic relationship between flux linkage analysis of the permanent magnet(PM)and armature field and the power factor is explored.Then,the connection between flux linkage and harmonics is established,clarifying the mechanism for improving power factor and torque.Improvements are focused on the PM and permeance.Regarding the PM structure,employing a Y-shaped PM structure effectively increases PM utilization,reduces leakage flux at the outer ends,and enhances the PM flux linkage.Concerning permeance,stator tooth design is optimized to cooperatively improve permeance harmonics,reduce the non-working flux linkage of the armature field,and enhance the fundamental modulation wave of the armature field responsible for torque generation.This improves the power factor while maintaining motor torque.Finally,through PM structural design,the motor torque performance is optimized.Furthermore,the performance of the Y-shaped PM motor is evaluated.A prototype was manufactured and tested.Theoretical analysis and experimental results demonstrate the effectiveness of the proposed method to a significant extent. 展开更多
关键词 Permanent magnet vernier motor Flux linkage power factor TORQUE
在线阅读 下载PDF
Regional Power Grid Carbon Emission Change Risk Assessment Based on Dynamic Carbon Emission Factors
3
作者 Huiyuan Yang Aihong Tang +6 位作者 Kanjun Zhang Ting Wang Hubing Zhou Xinran Li Hengxuan Li Wenhao Wang Jiao Peng 《CSEE Journal of Power and Energy Systems》 2026年第1期437-447,共11页
Under the“dual carbon”goals,it is imperative to incorporate carbon emissions-related factors into research of power grid risk assessment to meet the green transformation needs of the power grid.Therefore,this paper ... Under the“dual carbon”goals,it is imperative to incorporate carbon emissions-related factors into research of power grid risk assessment to meet the green transformation needs of the power grid.Therefore,this paper conducts a study on the risk assessment of carbon emissions changes in regional power grids based on dynamic carbon emission factors,aiming to quantitatively analyze the impact of random disturbances such as equipment failures or fluctuations in renewable energy generation on the carbon emission intensity of regional power grids.First,carbon emission change risk indicators are constructed from three dimensions:the probability,frequency,and magnitude of carbon emission changes.Second,a dynamic carbon emission factor calculation model is proposed to reflect the spatiotemporal change of carbon emissions in the regional power grid,considering output of different types of generators and the components of inter-area power transmission.Finally,with the premise of ensuring safe and stable operation of power grid,a quantitative assessment model for carbon emission change risks is proposed under the objective of minimizing the electricity loss.The sampling convergence conditions of the model are also derived.The results from the MRTS79 case study demonstrate the proposed method can effectively quantify and analyze the risk of carbon emissions changes in regional power grids,validating the effectiveness of the proposed model. 展开更多
关键词 Carbon emission factors optimal power flow quantification of carbon emission risk risk assessment sequential Monte Carlo method
原文传递
China’s development path for intermittent renewable energy power generation:The influence of diffusion factors
4
作者 Lu Zhang Ruiyu Zhang +2 位作者 Xiangcheng Zhang Baichen Xie Xianpeng Chen 《Chinese Journal of Population,Resources and Environment》 2025年第2期193-204,共12页
With the proposed carbon-neutrality targets,intermittent renewable energy will become increasingly significant for the power sector in the future.It is vital to study its development paths,particularly for wind power ... With the proposed carbon-neutrality targets,intermittent renewable energy will become increasingly significant for the power sector in the future.It is vital to study its development paths,particularly for wind power and photovoltaics,while considering constraints on diffusion potential.Using learning curves,dynamic programming,and Bass models,this study analyzes technological diffusion trends to determine the most cost-effective development route for intermittent renewable energy power generation in China by 2060.This study simplifies reality by examining the individual diffusion processes of wind and photovoltaic power,focusing on the self-diffusion characteristics of the two technologies.The study assumes that self-diffusion is the primary driver of future development and describe the influence of multiple factors.The study finds that supportive policies are key drivers of development in the early stages of intermittent renewable energy deployment,especially for photovoltaics.The current diffusion scale of photovoltaics has a greater positive impact on its future development than that of wind power due to lower costs.In the long term,the phased goal for 2030 is projected to be met ahead of schedule,and the majority of future intermittent renewable energy output is expected to come from photovoltaics.The rapid development phases of photovoltaic and wind power conclude at similar times,but the maximum diffusion potential of photovoltaics is higher than that of wind power.Investment constraints and technological levels affect the initial and middle phases of the development path,but their effects are limited.The capacity of the power grid remains the key constraint in the entire research field. 展开更多
关键词 Development path Intermittent renewable energy power generation Diffusion factor
在线阅读 下载PDF
Optimal reactive power planning in an industrial microgrid:a case study of Urmia Petrochemical plant
5
作者 Maryam Majidzadeh Mostafa Esmaeeli +2 位作者 Hadi Afkar Sajjad Golshannavaz Zhiyi Li 《Global Energy Interconnection》 2026年第1期208-218,共11页
In real industrial microgrids(MGs),the length of the primary delivery feeder to the connection point of the main substation is sometimes long.This reduces the power factor and increases reactive power absorption along... In real industrial microgrids(MGs),the length of the primary delivery feeder to the connection point of the main substation is sometimes long.This reduces the power factor and increases reactive power absorption along the primary delivery feeder from the external network.Besides,the giant induction electro-motors as the working horse of industries requires remarkable amounts of reactive power for electro-mechanical energy conversions.To reduce power losses and operating costs of the MG as well as to improve the voltage quality,this study aims at providing an insightful model for optimal placement and sizing of reactive power compensation capacitors in an industrial MG.In the presented model,the objective function considers voltage profile and network power factor improvement at the MG connection point.Also,it realizes power flow equations within which all operational security constraints are considered.Various reactive power compensation strategies including distributed group compensation,centralized compensation at the main substation,and distributed compensation along the primary delivery feeder are scrutinized.A real industrial MG,say as Urmia Petrochemical plant,is considered in numerical validations.The obtained results in each scenario are discussed in depth.As seen,the best performance is obtained when the optimal location and sizing of capacitors are simultaneously determined at the main buses of the industrial plants,at the main substation of the MG,and alongside the primary delivery feeder.In this way,74.81%improvement in power losses reduction,1.3%lower active power import from the main grid,23.5%improvement in power factor,and 37.5%improvement in network voltage deviation summation are seen in this case compared to the base case. 展开更多
关键词 Reactive power compensation Shunt capacitor Optimal placement and sizing Voltage profile improvement power factor correction
在线阅读 下载PDF
基于DIgSILENT/PowerFactory跨区域电网PSS选址及有效性验证
6
作者 时光 王海云 王维庆 《现代建筑电气》 2013年第6期4-8,共5页
基于DIgSILENT/PowerFactory模态分析功能,得出了发生机电振荡时局部和区域模态各电机参与因子的模态柱状图、向量图,以辨识PSS最佳安装位置。通过特征值分析和时域仿真,验证了系统安装PSS后的稳定性,对复杂系统PSS安装地址的选取至关... 基于DIgSILENT/PowerFactory模态分析功能,得出了发生机电振荡时局部和区域模态各电机参与因子的模态柱状图、向量图,以辨识PSS最佳安装位置。通过特征值分析和时域仿真,验证了系统安装PSS后的稳定性,对复杂系统PSS安装地址的选取至关重要。 展开更多
关键词 DIGSILENT powerfactory PSS 机电振荡 模态分析 参与因子
在线阅读 下载PDF
Period-doubling bifurcation in two-stage power factor correction converters using the method of incremental harmonic balance and Floquet theory 被引量:5
7
作者 Wang Fa-Qiang Zhang Hao Ma Xi-Kui 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第2期153-162,共10页
In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correcti... In this paper, period-doubling bifurcation in a two-stage power factor correction converter is analyzed by using the method of incremental harmonic balance (IHB) and Floquet theory. A two-stage power factor correction converter typically employs a cascade configuration of a pre-regulator boost power factor correction converter with average current mode control to achieve a near unity power factor and a tightly regulated post-regulator DC-DC Buck converter with voltage feedback control to regulate the output voltage. Based on the assumption that the tightly regulated postregulator DC-DC Buck converter is represented as a constant power sink and some other assumptions, the simplified model of the two-stage power factor correction converter is derived and its approximate periodic solution is calculated by the method of IHB. And then, the stability of the system is investigated by using Floquet theory and the stable boundaries are presented on the selected parameter spaces. Finally, some experimental results are given to confirm the effectiveness of the theoretical analysis. 展开更多
关键词 two-stage power factor correction converter incremental harmonic balance Floquet theory period-doubling bifurcation
原文传递
Fast-scale border collision bifurcation in SEPIC power factor pre-regulators 被引量:3
8
作者 刘芳 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第7期2394-2404,共11页
In this paper we report a kind of fast-scale instability occurring in the single-ended primary inductance converter (SEPIC) power factor pre-regulator, which is designed to operate in discontinuous conduction mode. ... In this paper we report a kind of fast-scale instability occurring in the single-ended primary inductance converter (SEPIC) power factor pre-regulator, which is designed to operate in discontinuous conduction mode. Main results are given by exact cycle-by-cycle computer simulations as well as theoretical analysis. It is found that the instability phenomenon manifests itself as a fast-scale bifurcation at the switching period, which implies the occurrence of border collision bifurcation, or is related to the transition of the regular operating mode of the SEPIC. According to the theoretical analysis and simulation results, the effects of parameters on system stability, and the locations of the bifurcation points are confirmed. Moreover, the effects of such an instability on power factor and switching stress are also discussed. Finally, the occurrence of the asymmetric bifurcation locations is investigated. The results show that this work provides a convenient means of predicting stability boundaries which can facilitate the selection of the practical parameters. 展开更多
关键词 fast-scale instability border collision bifurcation SEPIC power factor pre-regulator discontinuous current mode
原文传递
A novel arc welding inverter with unit power factor based on DSP control 被引量:3
9
作者 陈树君 曾华 +2 位作者 杜利 殷树言 陈永刚 《China Welding》 EI CAS 2006年第1期53-56,共4页
A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stag... A novel inverter power source is developed characterized with constant output current and unit power factor input. Digital signal processor ( DSP ) is used to realize power factor correction and control of back-stage inverter bridge of the arc welding inverter. The fore-stage adopts double closed loop proportion and integration (PI) rectifier technique and the back- stage adopts digital pulse width modulation ( PWM) technique. Simulated waves can be obtained in Matlab/Simulink and validated by experiments. Experiments of the prototype showed that the total harmonic distortion (THD) can be controlled within 10% and the power factor is approximate to 1. 展开更多
关键词 arc welding inverter power factor correction (PFC) digital signal processor (DSP) HARMONIC
在线阅读 下载PDF
Unexpected low thermal conductivity and large power factor in Dirac semimetal Cd3As2 被引量:1
10
作者 张成 周通 +8 位作者 梁斯航 曹钧植 袁翔 刘彦闻 沈瑶 王奇思 赵俊 杨中芹 修发贤 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期378-383,共6页
Thermoelectrics has long been considered as a promising way of power generation for the next decades. So far, extensive efforts have been devoted to the search of ideal thermoelectric materials, which require both hig... Thermoelectrics has long been considered as a promising way of power generation for the next decades. So far, extensive efforts have been devoted to the search of ideal thermoelectric materials, which require both high electrical conductivity and low thermal conductivity. Recently, the emerging Dirac semimetal Cd3As2, a three-dimensional analogue of graphene, has been reported to host ultra-high mobility and good electrical conductivity as metals. Here, we report the observation of unexpected low thermal conductivity in Cd3As2, one order of magnitude lower than the conventional metals or semimetals with a similar electrical conductivity, despite the semimetal band structure and high electron mobility. The power factor also reaches a large value of 1.58 mW.m 1 .K-2 at room temperature and remains non-saturated up to 400 K. Corroborating with the first-principles calculations, we find that the thermoelectric performance can be well-modulated by the carrier concentration in a wide range. This work demonstrates the Dirac semimetal Cd3As2 as a potential candidate of thermoelectric materials. 展开更多
关键词 Dirac semimetal thermal conductivity power factor thermoelectric material
原文传递
Power Transformer No-Load Loss Prediction with FEM Modeling and Building Factor Optimization 被引量:2
11
作者 Ehsan Hajipour Pooya Rezaei +1 位作者 Mehdi Vakilian Mohsen Ghafouri 《Journal of Electromagnetic Analysis and Applications》 2011年第10期430-438,共9页
Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for t... Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for the transformer manufacturer. In this paper an effective and novel method is proposed to determine all components of the iron core losses applying a combination of the empirical and numerical techniques. In this method at the first stage all computable components of the core losses are calculated, using Finite Element Method (FEM) modeling and analysis of the transformer iron core. This method takes into account magnetic sheets anisotropy, joint losses and stacking holes. Next, a Quadratic Programming (QP) optimization technique is employed to estimate the incomputable components of the core losses. This method provides a chance for improvement of the core loss estimation over the time when more measured data become available. The optimization process handles the singular deviations caused by different manufacturing machineries and labor during the transformer manufacturing and overhaul process. Therefore, application of this method enables different companies to obtain different results for the same designs and materials employed, using their historical data. Effectiveness of this method is verified by inspection of 54 full size distribution transformer measurement data. 展开更多
关键词 BUILDING factor CORE LOSSES FINITE ELEMENT Method power Transformer
暂未订购
A new high-performance AC/DC power factor correction switching converter based on one-cycle control technology and active floating-charge technology 被引量:3
12
作者 高潮 《Journal of Chongqing University》 CAS 2008年第2期119-124,共6页
A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t... A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value. 展开更多
关键词 AC/DC converter floating charge technology active power factor correction switching converter
在线阅读 下载PDF
Economical Optimization of Grid Power Factor Using Predictive Data 被引量:1
13
作者 Chaojiong Huang Jason Gu +2 位作者 Haiying Liu Yuansheng Lu Jun Luo 《IEEE/CAA Journal of Automatica Sinica》 EI CSCD 2019年第1期258-267,共10页
We present an electrical grid optimization method for economical benefit. After simplifying an IEEE feeder diagram, we build a compact smart grid system including a photovoltaic-inverter system, a shunt capacitor, an ... We present an electrical grid optimization method for economical benefit. After simplifying an IEEE feeder diagram, we build a compact smart grid system including a photovoltaic-inverter system, a shunt capacitor, an on-load tapchanger(OLTC) and transmission lines. The system power factor(PF) regulation and reactive power dispatching are indispensable to improve power quality. Our control method uses predictive weather and load data to decide engaging or tripping the shunt capacitor, or reactive power injection by the photovoltaic-inverter system, ultimately to keep the system PF in a good range. From the perspective of economics, the economical model is considered as a decision maker in our predictive data control method.Capacitor-only control strategy is a common photovoltaic(PV)regulation method, which is treated as a baseline case. Simulations with GridLAB-D on profiled loads and residential loads have been carried out. The comparison results with baseline control strategy and our predictive data control method show the appreciable economical benefit of our method. 展开更多
关键词 GRID OPTIMIZATION GridLAB-D inverter power factor PREDICTIVE DATA control SHUNT CAPACITOR
在线阅读 下载PDF
Performance Evaluation of a Permanent Magnet Electric-Drive- Reconfigured Onboard Charger with Active Power Factor Correction 被引量:4
14
作者 Feng Yu Zhihao Zhu +1 位作者 Jingfeng Mao Juping Gu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第1期72-80,共9页
This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase perm... This paper presents a comprehensive charging operation for an electric-drive-reconfigured onboard charger(EDROC)with active power factor correction(APFC).The charging topology exclusively utilizes the three-phase permanent magnet synchronous motor(PMSM)propulsion system as a three-channel boost-type converter in which only a contactor and a small diode bridge are added.First,the operation scenario of the EDROC is introduced.Second,the relationship between electromagnetic torque and rotor position is investigated.Third,the current ripple cancellation of the EDROC is discussed in detail.Moreover,to implement the single-phase APFC along with charging voltage/current regulation of propulsion battery,control strategies including current balancing and synchronous/interleaving PWM strategies are incorporated.Finally,200W proof-of-concept prototype-based tests are conducted under different operation scenarios. 展开更多
关键词 Active power factor correction current balancing electric-drive-reconfigured electromagnetic torque INTERLEAVING onboard charger.
在线阅读 下载PDF
Carbon Emission Factors Prediction of Power Grid by Using Graph Attention Network 被引量:2
15
作者 Xin Shen Jiahao Li +3 位作者 YujunYin Jianlin Tang Weibin Lin Mi Zhou 《Energy Engineering》 EI 2024年第7期1945-1961,共17页
Advanced carbon emission factors of a power grid can provide users with effective carbon reduction advice,which is of immense importance in mobilizing the entire society to reduce carbon emissions.The method of calcul... Advanced carbon emission factors of a power grid can provide users with effective carbon reduction advice,which is of immense importance in mobilizing the entire society to reduce carbon emissions.The method of calculating node carbon emission factors based on the carbon emissions flow theory requires real-time parameters of a power grid.Therefore,it cannot provide carbon factor information beforehand.To address this issue,a prediction model based on the graph attention network is proposed.The model uses a graph structure that is suitable for the topology of the power grid and designs a supervised network using the loads of the grid nodes and the corresponding carbon factor data.The network extracts features and transmits information more suitable for the power system and can flexibly adjust the equivalent topology,thereby increasing the diversity of the structure.Its input and output data are simple,without the power grid parameters.We demonstrated its effect by testing IEEE-39 bus and IEEE-118 bus systems with average error rates of 2.46%and 2.51%. 展开更多
关键词 Predict carbon factors graph attention network prediction algorithm power grid operating parameters
在线阅读 下载PDF
An Improved Non-isolated LED Converter with Power Factor Correction and Average Current Mode Control 被引量:1
16
作者 Renbo Xu Hongjian Li +1 位作者 Yongzhi Li Changqian Zhang 《Circuits and Systems》 2011年第3期242-248,共7页
A new type of high power LED drivers is proposed by adopting an improved two-stages non-isolated configuration. In order to improve power factor and achieve accurate average current control under universal input volta... A new type of high power LED drivers is proposed by adopting an improved two-stages non-isolated configuration. In order to improve power factor and achieve accurate average current control under universal input voltages ranging from 100 Vrms to 240 Vrms, the power factor correction and average current mode control methods operating in continuous current conduction mode are designed and implemented. With the LUMILEDS emitter type LEDs, a laboratory prototype is built and measured. And from the measured results, it could be concluded that the proposed driver has many better performances such as high power factor, low current harmonic, accurate average current control and switch protection. 展开更多
关键词 High power LED power factor CORRECTION AVERAGE Current Mode Control
暂未订购
Intelligent power factor compensation equipment of three phase low voltage loads 被引量:1
17
作者 罗安 董密 +1 位作者 Richard Dzudzor 《Journal of Central South University of Technology》 2002年第1期64-69,共6页
An intelligent power factor correction scheme is presented for three phase low power factor loads. This new scheme is able to perform individual phase sensing of parameters by monitoring at all times to sense a change... An intelligent power factor correction scheme is presented for three phase low power factor loads. This new scheme is able to perform individual phase sensing of parameters by monitoring at all times to sense a change in system parameters and affects individual phase correction by applying the exact amount of reactive components needed for each phase, and can also reduce negative sequence current caused by the load to improve system balance. An optimization criterion is used for the proper calculation of reactive power steps in a power compensation installation of capacitor banks. The criterion is enabled by sampling measurements performed on the electrical plant examined within specific interval of time. 展开更多
关键词 power factor correction individual phase sensing negative sequence current system balance
在线阅读 下载PDF
Power Factor Correction Rectifier with a Variable Frequency Voltage Source in Vehicular Application 被引量:1
18
作者 Amine Toumi Mohamed Radhouan Hachicha +1 位作者 Moez Ghariani Rafik Neji 《Intelligent Control and Automation》 2014年第1期1-11,共11页
This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in t... This paper presents a PFCVF (Power Factor Correction) rectifier that uses a variable frequency source for alternators for electric and hybrid vehicles application. In such application, the frequency of the signal in the alternator changes according to the vehicle speed, more over the loading effect on the alternator introduces harmonic currents and increases the alternator apparent power requirements. To overcome these problems and aiming more stability and better design of the alternator, a new third harmonic injection technique is proposed. This technique allows to preserve a good THD (Total Harmonic Distortion) of the input source at any frequency and to decrease losses in semiconductors switches, thereby allowing more stability and reducing the apparent power requirements. A comparative study between the standard and the new technique is made and highlights the effectiveness of the new design. A detailed analysis of the proposed topology is presented and simulations as well as experimental results are shown. 展开更多
关键词 ASYNCHRONOUS Machine Control-Oriented Vector of Rotor Flux PWM BOOST Converter HARMONIC Injection power factor Correction THREE-PHASE RECTIFIER JUNCTION Temperature
暂未订购
Analysis of Starting Performance of High PowerFactor Induction Motor with Floating Windingin Parallel Connection with Capacitors
19
作者 ZHANG Qi XIE Guo dong (School of Automation, Shanghai University) 《Advances in Manufacturing》 SCIE CAS 1999年第4期299-303,共5页
In this paper, by using a matrix technique, a dynamic model of high power factor induction motor with floating winding in parallel connection with capacitors is established. Then, the starting performance of this mot... In this paper, by using a matrix technique, a dynamic model of high power factor induction motor with floating winding in parallel connection with capacitors is established. Then, the starting performance of this motor is analyzed by computer simulation. By comparison of the tested and computed results, which are in good agreement, the dynamic model and simulative method are verified. 展开更多
关键词 high power factor starting performance computer simulation
在线阅读 下载PDF
Isolated single stage high power factor AC/DC converter
20
作者 王卫 贲洪奇 高国安 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期334-337,共4页
The problem of harmonic pollution has brought wide attention with the increase of power customers. The adoption of the technology of active power factor correction (APFC) with advanced high frequency power converter i... The problem of harmonic pollution has brought wide attention with the increase of power customers. The adoption of the technology of active power factor correction (APFC) with advanced high frequency power converter is a more efficient solution to the problem of harmonic pollution. A single stage isolated high power factor AC/DC converter, which features wide range DC output, high power factor, lower harmonic pollution in input current, and phase shift PWM full bridge circuit can achieve soft switching. The principle of the circuit topology and the reasons of voltage surges across the power switch are analyzed. Experiment results illustrate that this circuit has the advantages of high power factor and lower harmonic distortion. 展开更多
关键词 single stage power factor correction CONVERTER voltage surge
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部