期刊文献+
共找到220篇文章
< 1 2 11 >
每页显示 20 50 100
Ferrara ring segments implantation for treating keratoconus 被引量:1
1
作者 Mohammed Ali Abu Ameerh Ghada Ismail Hamad +3 位作者 Osama H. Ababneh Almutez M. Gharaibeh Rola M. Al Refai Muawyah D. Al Bdour 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第5期586-590,共5页
AIM: To investigate the efficacy of Ferrara rings (FR) implantation in the treatment of keratoconus.METHODS: It was a retrospective case series descriptive study. The sample was comprised of 50 patients 79 eyes diagno... AIM: To investigate the efficacy of Ferrara rings (FR) implantation in the treatment of keratoconus.METHODS: It was a retrospective case series descriptive study. The sample was comprised of 50 patients 79 eyes diagnosed with progressive keratoconus. This included 24 (48%) males and 26 (52%) females between the age of 13 and 44 years. All participants underwent surgical implantation of FR in the period between January 2009 and September 2010 at Jordan University Hospital. Thorough ophthalmologic examinations were applied to measure vital variables for each pathological condition before and after surgery. RESULTS: Findings indicated an overall significant postoperative improvement in both uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) throughout follow up visits. Moreover, results illustrated a significant decrease in spherical equivalent (SE) and keratometric readings (lower, higher and the average). CONCLUSION: Surgical intervention strategies are being frequently developed to meet the needs of patients with keratoconus. The implantation of Ferrara rings has proven to be a safe and feasible alternative procedure for the treatment of mild-moderate keratoconus especially for patients with contact lenses intolerance. We have found that this procedure has improved visual outcomes in all eyes studied. Nevertheless, further research is needed to investigate long term outcomes. 展开更多
关键词 CORNEA KERATOCONUS Ferrara rings intracorneal ring segments.
原文传递
Preliminary results of a new intrastromal corneal ring segment as a tissue saving procedure in photorefractive keratectomy to correct moderate to high myopia 被引量:2
2
作者 Sandro Coscarelli Pablo Rodrigues +1 位作者 Guilherme Rocha Leonardo Torquetti 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第12期1955-1960,共6页
AIM:To evaluate the clinical results after implantation of a new intrastromal corneal ring segment(ICRS)associated with photorefractive keratectomy(PRK)to correct high myopia(HM)patients with thin corneas.METHODS:We e... AIM:To evaluate the clinical results after implantation of a new intrastromal corneal ring segment(ICRS)associated with photorefractive keratectomy(PRK)to correct high myopia(HM)patients with thin corneas.METHODS:We evaluated 42 eyes of 23 HM patients that had ICRS implantation followed by PRK.The mean age of patients was 29.1±7.12 y(range 18 to 40 years old).Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),keratometry,spherical equivalent,pachymetry,and aberrometry were compared using ANOVA with repeated measurements evaluated preoperatively and at last follow-up visit after the procedures.The refractive predictability and simulated/real corneal ablation were also assessed.RESULTS:The mean follow-up time after PRK was 6.8±1.6 mo.The mean preoperative UCVA improved from 20/800 preoperative to 20/100 after ICRS and 20/35 after PRK.The mean preoperative BCVA was 20/25(range from 20/30 to 20/20)and remained unchanged after ICRS implantation.Following the PRK the mean BCVA was 20/25(range from 20/30 to 20/20).The mean spherical equivalent decreased from-7.25±1.12(range-5.00 to-9.00)preoperatively to-3.32±1.0(range-2.00 to-5.00)postoperatively(P<0.001)after ICRS implantation and decreased from-2.44±1.51 preoperatively to 0.32±0.45(range-0.625 to 0.875)postoperatively(P<0.001)after PRK.The change in BCVA and topographic astigmatism was statistically significant(P<0.0001).CONCLUSION:ICRS in HM associated with PRK can be a tissue saving procedure and an alternative surgical option for correction of moderate to high myopia. 展开更多
关键词 high myopia intrastromal corneal ring segments photorefractive keratectomy
原文传递
Clinical outcomes after intrastromal corneal ring segments reoperation in keratoconus patients 被引量:1
3
作者 Lconardo Torquetti Guilherme Ferrara +3 位作者 Franklin Almeida Leandro Cunha Paulo Ferrara Jesus Merayo-Lloves 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第6期796-800,共5页
AIM:To evaluate the clinical outcomes after Ferrara intrastromal corneal ring segments(ICRS)reoperation in patients with keratoconus.METHODS:A total of 37 keratoconus eyes implanted with intrastromal corneal ring segm... AIM:To evaluate the clinical outcomes after Ferrara intrastromal corneal ring segments(ICRS)reoperation in patients with keratoconus.METHODS:A total of 37 keratoconus eyes implanted with intrastromal corneal ring segments,which had an ICRS exchange,addition,reposition or removal were evaluated.Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),keratometry(K),asphericity(Q)and pachymetry at the thinnest point(PTP)of the cornea were evaluated using a corneal tomography(Oculus Pentacam,USA)RESULTS:The mean follow-up time after the reoperation was 30.5±9.7 months.The mean UCVA improved from 20/300 to 20/80(P=0.005);the mean BCVA improved from 20/160 to 20/50(P=0.0002),the mean keratometry reduced from 49.33±4.19D to 46.16±3.90D(P=0.0001),the mean pachymetry at the thinnest point increased from 450±42.9μm to 469±40.8μm(P=0.0001).The asphericity increased from-0.84±0.74 to-0.35±0.81(P=0.15)and the spherical equivalent reduced from-4.64±4.87D to-3.04±3.45D(P=0.137).The changes in the asphericity and spherical equivalent were not statistically significant.CONCLUSION:Ferrara ICRS implantation showed to be a reversible and readjustable surgical procedure for keratoconus treatment.Good outcomes can be obtained even after removal,addition,reposition or exchange of ICRS. 展开更多
关键词 KERATOCONUS intrastromal corneal ring segments REOPERATION
原文传递
Investigation of the efficiency of intrastromal ring segments with cross-linking using different sequence and timing for keratoconus 被引量:1
4
作者 Xuan-Li Liu Ping-Hua Li +1 位作者 Pierre Fournie Francois Malecaze 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期703-708,共6页
· AIM: To evaluate and compare the efficacy and stability of intrastromal corneal ring segment(ICRs)implantation with cross-linking(CXL) using different sequence and timing.· METHODS: In this single retrospe... · AIM: To evaluate and compare the efficacy and stability of intrastromal corneal ring segment(ICRs)implantation with cross-linking(CXL) using different sequence and timing.· METHODS: In this single retrospective study, 86 keratoconic eyes subjected the ICRs implantation. We analyzed only 41 eyes that had complete follow-ups.They were divided into three groups: ICRs implantation was applied only(group normal), ICRs first followed by CXL immediately(group CXL-S), CXL first followed by ICRs long after(group CXL-B). The visual acuity,refractive results, keratometry were compared preoperatively and 1y postoperatively. Their differences among the three groups were also analyzed.·RESULTS: Group normal comprised 25 eyes, group CXL-S 8 eyes, and group CXL-B 8 eyes. There were improvements in the mean uncorrected distance visual acuity(UDVA) and the mean corrected distance visual acuity(CDVA) compared preoperatively and 1y postoperatively [UDVA: 0.31(P =0.030) logarithmic minimum angle of resolution(log MAR) group normal, 0.4(P =0.020) group CXL-S, 0.45(P =0.001) group CXL-B;CDVA : 0. 21 log MAR( P = 0. 013) group normal, 0. 30(P =0.036) group CXL-S; 0.26(P =0.000) group CXL-B].The refractive and topographic outcomes also showed improvements. In terms of comparisons among the three groups, all the P values were above 0.05, showing no significant difference. But only group CXL-B had improvement in UDVA and CDVA for all the patients.·CONCLUSION: With safety and good visual outcomes,ICRs implantation is a viable alternative for keratoconus.No significant difference was found among these three groups. 展开更多
关键词 KERATOCONUS intrastromal corneal ring segment cross-linking
原文传递
Evaluation of a new nomogram for Ferrara ring segment implantation in keratoconus
5
作者 Joaquín Fernández Cristina Peris-Martínez +3 位作者 Antonio Pérez-Rueda Sidi Mohamed Hamida Abdelkader María JoséRoig-Revert David P.Pinero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第9期1371-1383,共13页
AIM:To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data.METHODS:This prospecti... AIM:To evaluate the short-term clinical outcomes of Ferrara rings in keratoconus using an optimized nomogram developed after several years of research and retrospective analysis of clinical data.METHODS:This prospective longitudinal non-comparative clinical trial evaluated 88 eyes of 88 patients(age 18-62 y)with keratoconus diagnosis from two Spanish centers.Ferrara ring segment(AJL Ophthalmic)implantation was performed in all cases,using the mechanical procedure in 25 eyes(28.4%)and a femtosecond laser-assisted procedure in 63 eyes(71.6%).The ring segments implanted in each case were selected using a new optimized nomogram that considered variables such as anterior corneal asphericity and astigmatism or the discrepancy among astigmatism and coma orientations.Visual,refractive,corneal topographic,aberrometric,and pachymetric changes after surgery were evaluated during a 3-month follow-up.RESULTS:The implants induced a significant refractive change as well as an improvement in uncorrected(UDVA)and corrected distance visual acuity(CDVA;P<0.001).Postoperative CDVA of 0.10 log MAR or better was achieved in 28.4%and 46.5%of eyes,respectively.Two eyes(2.3%)lost two or more lines of CDVA whereas a total of 53.5%of eyes gained lines of CDVA.A significant central anterior and posterior corneal flattening was induced(P≤0.003),with a significant reduction of anterior(P<0.001)and posterior corneal astigmatisms(P=0.048),and a change in anterior asphericity(P<0.001).Total primary coma(6 mm pupil)change was also statistically significant(preoperative 3.66±3.04μm vs postoperative 2.33±2.26μm,P<0.001).No significant differences were found in the effect of ring segments between cases implanted using the mechanical and femtosecond techniques(P≥0.101).CONCLUSION:The implantation of Ferrara rings based on the nomogram evaluated is safe and effective for promoting a visual rehabilitation in keratoconus,with a relevant control of primary coma aberration. 展开更多
关键词 intracorneal ring segment Ferrara ring segment femtosecond KERATOCONUS coma aberration
原文传递
Double intrastromal corneal ring segment implantation: a new approach for improved clinical outcomes in keratoconus patients
6
作者 Sandro Coscarelli Reinaldo de Oliveira Sieiro +2 位作者 Victoria Moreira Fernandes Sandro P.Coscarelli Leonardo Torquetti 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第11期2023-2030,共8页
AIM:To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment(ICRS)model followed by an additional short-arc ICRS implant in keratoconus patients.METHODS:This retrospec... AIM:To evaluate the clinical outcomes after subsequent implantation of a new intrastromal corneal ring segment(ICRS)model followed by an additional short-arc ICRS implant in keratoconus patients.METHODS:This retrospective single-arm cohort study evaluated 25 eyes of 21 keratoconus patients implanted with the new ICRS followed by 140-arch length ICRS(140-ICRS)implantation.Uncorrected distance visual acuity(UDVA,logMAR),corrected distance visual acuity(CDVA,logMAR),sphere,astigmatism,keratometry,spherical equivalent(SE),and asphericity were compared preoperatively and postoperatively after both ICRS implantation.RESULTS:The average follow-up time after 140-ICRS implantation was 6.40±2.20mo.The mean preoperative UDVA improved from 1.27±0.14 preoperative to 0.52±0.26 after both ICRS implantation(P=0.03).The mean sphere value reduced from-5.34±2.74 preoperatively to-2.06±1.84 postoperatively(P<0.001)after the first ICRS implantation and decreased to-0.59±1.54 postoperatively(P<0.001)after 140-ICRS implantation.The mean preoperative astigmatism was-3.72±1.56 and improved to-2.82±1.08 after the first ICRS implantation,and following the 140-ICRS implantation,the mean astigmatism was-1.37±0.67(P=0.001).The SE and asphericity changes were statistically significant(P<0.001).The researchers did not find intraoperative or postoperative complications for both procedures.CONCLUSION:The combination of 2 different ICRSs can efficiently regularize the cornea,reduce the SE,and improve visual acuity in selected keratoconus patients. 展开更多
关键词 KERATOCONUS CORNEA intrastromal corneal ring segments refractive surgery
原文传递
Clinical outcomes after implantation of a new intrastromal corneal ring with 140-degree of arc in patients with corneal ectasia 被引量:3
7
作者 Jordana Sandes Larissa R.S.Stival +5 位作者 Marcos Pereira de Avila Paulo Ferrara Guilherme Ferrara Leopoldo Magacho Luana P.N.Araujo Leonardo Torquetti 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第5期802-806,共5页
AIM:To evaluate the clinical and tomographic outcomes after implantation of a new intrastromal corneal ring segment(ICRS) with 140-degrees of arc in eyes with corneal ectasia.METHODS:We evaluated patients with cor... AIM:To evaluate the clinical and tomographic outcomes after implantation of a new intrastromal corneal ring segment(ICRS) with 140-degrees of arc in eyes with corneal ectasia.METHODS:We evaluated patients with corneal ectasia implanted with Ferrara 140° ICRS from April 2010 to February 2015.Outcome measures included preoperative and postoperative corrected distance visual acuity(CDVA),keratometry simulated(K) reading,tomographic astigmatism and asphericity.All patients were evaluated using the Pentacam Scheimpflug system.RESULTS:The study evaluated 58 eyes.The mean followup was 16.81±10.8 mo.The CDVA(logM AR) improved from 0.5±0.20(20/60) to 0.3±0.21(20/40)(P〈0.01).The average K reduced from 49.87±7.01 to 47.34±4.90 D(P〈0.01).The asphericity changed from-0.60±0.86 to-0.23±0.67 D(P〈0.01).The mean preoperative tomographic astigmatism decreased from-8.0±3.45 to-4.53±2.52 D(P〈0.01).CONCLUSION:The new ICRS model with 140-degrees of arc effectively improve the visual acuity and reduce the high astigmatism usually found in patients with corneal ectasia. 展开更多
关键词 KERATOCONUS intrastromal corneal ring segment corneal ectasia
原文传递
Studies on the key parameters in segmental lining design 被引量:2
8
作者 Zhenchang Guan Tao Deng +1 位作者 Gang Wang Yujing Jiang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第6期674-683,共10页
The uniform ring model and the shell-spring model for segmental lining design are reviewed in thisarticle. The former is the most promising means to reflect the real behavior of segmental lining, while thelatter is th... The uniform ring model and the shell-spring model for segmental lining design are reviewed in thisarticle. The former is the most promising means to reflect the real behavior of segmental lining, while thelatter is the most popular means in practice due to its simplicity. To understand the relationship and thedifference between these two models, both of them are applied to the engineering practice of FuzhouMetro Line I, where the key parameters used in both models are described and compared. The effectiveratio of bending rigidity h reflecting the relative stiffness between segmental lining and surroundingground and the transfer ratio of bending moment x reflecting the relative stiffness between segment andjoint, which are two key parameters used in the uniform ring model, are especially emphasized. Thereasonable values for these two key parameters are calibrated by comparing the bending momentscalculated from both two models. Through case studies, it is concluded that the effective ratio of bendingrigidity h increases significantly with good soil properties, increases slightly with increasing overburden,and decreases slightly with increasing water head. Meanwhile, the transfer ratio of bending moment xseems to only relate to the properties of segmental lining itself and has a minor relation with the groundconditions. These results could facilitate the design practice for Fuzhou Metro Line I, and could alsoprovide some references to other projects with respect to similar scenarios. 展开更多
关键词 segmental lining Uniform ring model Shell-spring model Effective ratio of bending rigidity Transfer ratio of bending moment
在线阅读 下载PDF
基于改进YOLOv8的树木年轮实例分割及信息检测方法
9
作者 王品博 王雨晨 +1 位作者 王双永 周海宾 《木材科学与技术》 北大核心 2025年第3期7-18,共12页
在气候学、生态学、考古学等诸多领域,树木年轮蕴含的环境变迁与历史演替信息具有不可替代的研究价值。为解决传统年轮检测方法存在效率低、易受人为因素干扰等问题,研究提出DCW-YOLOv8年轮实例分割模型,运用可扩张残差(Dilation-wise R... 在气候学、生态学、考古学等诸多领域,树木年轮蕴含的环境变迁与历史演替信息具有不可替代的研究价值。为解决传统年轮检测方法存在效率低、易受人为因素干扰等问题,研究提出DCW-YOLOv8年轮实例分割模型,运用可扩张残差(Dilation-wise Residual,DWR)注意力模块、轻量级通用上采样算子(Content-Aware ReAssembly of Features,CARAFE)、动态非单调聚焦机制边界框损失函数(Weighted Interpolation of Sequential Evidence for Intersection over Union,Wise-IoU)组合改进,并设计一种依据模型掩码获取年轮数量与宽度信息的检测方法。消融试验和前沿模型对比试验结果表明,DCWYOLOv8模型掩码平均精度mAP@0.50、mAP@0.50∶0.95提升,达到86.4%、53.6%,优于同类算法;注意力可视化比较结果表明,DCW-YOLOv8对年轮特征注意力更强;年轮信息检测结果表明,年轮数量检测准确率达到86.2%,年轮宽度检测误差在±0.5 mm范围内的占70%,总体平均误差为0.295 mm。研究提出的DCW-YOLOv8模型为年轮自动化检测提供新的思路和方法。 展开更多
关键词 树木年轮 深度学习 实例分割 年轮宽度 年轮数量
在线阅读 下载PDF
新型管片接头盾构隧道衬砌结构整环足尺试验研究 被引量:1
10
作者 赵明应 何应道 +3 位作者 吴鑫林 张肇一 白海文 柳献 《城市轨道交通研究》 北大核心 2025年第5期143-148,共6页
[目的]目前,我国的盾构隧道结构存在管片局部削弱、接缝变形大、施工效率低及不利于自动化拼装等问题,因此,有必要对采用新型管片接头的盾构隧道结构力学性能进行研究。[方法]介绍了试验概况、加载方案及测试系统;基于新型管片接头的力... [目的]目前,我国的盾构隧道结构存在管片局部削弱、接缝变形大、施工效率低及不利于自动化拼装等问题,因此,有必要对采用新型管片接头的盾构隧道结构力学性能进行研究。[方法]介绍了试验概况、加载方案及测试系统;基于新型管片接头的力学性能,对盾构隧道衬砌结构力学性能进行分析,并开展新型管片接头盾构隧道衬砌结构整环足尺试验。[结果及结论]采用新型管片接头的盾构隧道衬砌结构在各工况下的收敛变形、接缝变形量及连接件受力均满足设计要求;管片结构整体变形呈现左右不对称的特点,管片结构右腰的变形量和内力均大于左腰;管片结构在弹性阶段的刚度为2.21×10^(4)N/mm;由于正弯矩接头连接件的受力相较于负弯矩接头更加不利,因此在施工运营过程中,应重点关注管片结构顶底位置的接缝受力情况。 展开更多
关键词 盾构隧道 管片接头 整环足尺试验
在线阅读 下载PDF
基于点云法向量与聚类算法的盾构隧道断面连续提取方法研究
11
作者 吴勇 李文海 +4 位作者 黄江华 卢泳 鲍艳 吴旭 倪树新 《建筑结构》 北大核心 2025年第15期124-128,共5页
三维激光扫描技术在隧道变形检测领域已获得广泛研究和应用,而隧道断面的提取质量直接决定了检测的精度。目前,基于点云数据提取断面的方法存在提取位置噪声过多、去噪效果欠佳的问题。鉴于隧道狭长的结构特点,提出了一种基于点云法向... 三维激光扫描技术在隧道变形检测领域已获得广泛研究和应用,而隧道断面的提取质量直接决定了检测的精度。目前,基于点云数据提取断面的方法存在提取位置噪声过多、去噪效果欠佳的问题。鉴于隧道狭长的结构特点,提出了一种基于点云法向量与聚类算法的盾构隧道断面连续提取方法。该方法根据隧道噪声点与管片点云法向量差异明显的特性,快速剔除噪声点,利用K-means聚类算法进行管环分割,通过约束断面提取位置,实现盾构隧道高质量横断面连续提取。以北京某地铁盾构隧道为试验对象,成功实现了隧道管环分割及断面逐环连续提取。试验结果表明,该方法能够快速、准确地识别断面提取位置,并且满足精度要求。 展开更多
关键词 盾构隧道 点云法向量 聚类算法 管环分割 断面提取
在线阅读 下载PDF
基于激光跟踪仪的环形拼接主镜初始装调方法研究
12
作者 杨慧 戴懿纯 +4 位作者 谭旭 王昆延 王斌 杨德华 金振宇 《光子学报》 北大核心 2025年第8期127-137,共11页
针对中国巨型太阳望远镜(CGST)子镜对准过程中面外自由度误差调整至光学测量系统捕捉范围和面内自由度误差控制在不影响成像质量范围的问题,对CGST的初始装调展开研究。CGST的主镜采用独特的环形拼接结构,根据其子镜面外自由度和面内自... 针对中国巨型太阳望远镜(CGST)子镜对准过程中面外自由度误差调整至光学测量系统捕捉范围和面内自由度误差控制在不影响成像质量范围的问题,对CGST的初始装调展开研究。CGST的主镜采用独特的环形拼接结构,根据其子镜面外自由度和面内自由度的调整特点和影响方式,分别给出了面外和面内自由度的装调要求。针对这些要求,探讨了采用激光跟踪仪进行初始装调的可能性。建立了测量模型并根据主要的测量误差进行了误差分析,同时在实验系统上对该测量方法进行了初步的实验验证。预估结果表明,激光跟踪仪能够将绕X轴旋转的面外倾斜装调至±0.57',绕Y轴旋转的面外倾斜装调至±0.33',沿Z轴的面外平移装调至±64.58μm,沿X轴和Y轴方向的面内平移可装调至±56.89μm、±52.78μm,面内旋转可装调至±0.57'。该结果能够较好地实现子镜面外自由度的装调要求,而面内自由度装调要求较高,目前利用激光跟踪仪很难进一步提升沿Y轴方向的面内平移和面内旋转的装调精度,需要结合其他测量方法研究精度更高的装调方案。该研究可为CGST的装调工作提供参考,并为后续子镜共焦和共相的实施以及提升共相控制效果提供技术支撑。 展开更多
关键词 中国巨型太阳望远镜 环形拼接望远镜 初始装调 子镜对准 面外自由度 面内自由度 激光跟踪仪
在线阅读 下载PDF
考虑接头转动的盾构隧道椭圆化环变形行为研究
13
作者 邹洋 叶艺超 +2 位作者 唐钱龙 彭立敏 雷明锋 《中南大学学报(自然科学版)》 北大核心 2025年第9期3797-3809,共13页
提出一种考虑椭圆化特征的管片环变形计算模型,基于线性叠加原理,推导均布条件下考虑接头转动的管片椭圆化环变形修正计算表达式,并将模型计算结果与实验结果进行对比分析,最终建立接头非均布非对称条件的管片椭圆化环变形通用计算方法... 提出一种考虑椭圆化特征的管片环变形计算模型,基于线性叠加原理,推导均布条件下考虑接头转动的管片椭圆化环变形修正计算表达式,并将模型计算结果与实验结果进行对比分析,最终建立接头非均布非对称条件的管片椭圆化环变形通用计算方法。研究结果表明:接头的数量与分布形式对管片环变形行为均有影响,特别是拱腰处的接头对变形的影响显著;相比于管片接头均布对称条件,接头均布非对称、对称非均布以及非均布非对称时的最大环变形量分别减少了6%、21%和33%,且最大减少量均出现在拱顶;与封顶块处于正上方相比,当封顶块处在斜上方时,拱顶、拱腰、拱底的最大环变形量分别减少了15.04%、37.33%和23.57%,盾构错缝拼装能明显降低盾构管片结构的收敛变形值。该模型综合考虑了接头转动、椭圆化特征、接头分布等因素的影响,并通过实测结果证明了该方法的适用性与有效性。 展开更多
关键词 盾构隧道 管片接头 接头非对称 椭圆化 环变形
在线阅读 下载PDF
单层双列背绕式直线感应电机反相供电下电感参数特性研究
14
作者 李彦飞 李子欣 +2 位作者 张航 赵聪 李耀华 《电工技术学报》 北大核心 2025年第22期7140-7152,共13页
单层双列背绕式直线感应电机具有加工难度低、容错性高、组装方便等优点,在高速电磁驱动领域应用前景广阔。然而,该电机背部间隙内绕组磁场耦合强烈,加之分段供电运行模式下静态纵向端部效应明显,导致电机参数分析难度较大。该文分析了... 单层双列背绕式直线感应电机具有加工难度低、容错性高、组装方便等优点,在高速电磁驱动领域应用前景广阔。然而,该电机背部间隙内绕组磁场耦合强烈,加之分段供电运行模式下静态纵向端部效应明显,导致电机参数分析难度较大。该文分析了反相供电方式降低背部间隙绕组漏感的原理,并通过建立反相供电下考虑定子段间气隙在内的等效磁路模型,解析推导了电机气隙磁通密度及电感参数,搭建有限元仿真模型及实验原理样机开展验证,仿真与实验结果表明了分析的正确性。 展开更多
关键词 单层双列直线电机 背绕式绕组 分段供电 反相供电 段间气隙 电感参数
在线阅读 下载PDF
盾构法隧道通用楔形管片排版及纠偏算法的研究
15
作者 黄捷 《工程建设与设计》 2025年第15期83-86,共4页
针对盾构法隧道通用楔形管片在区间隧道中设置人行联络通道时,要在局部采用特殊环所带来的排版复杂性和纠偏控制难题,分析当前通用管片排版在直线和曲线段的拟合能力。通过引入基于相对旋转角的人行联络通道特殊环排版算法,结合掘进过... 针对盾构法隧道通用楔形管片在区间隧道中设置人行联络通道时,要在局部采用特殊环所带来的排版复杂性和纠偏控制难题,分析当前通用管片排版在直线和曲线段的拟合能力。通过引入基于相对旋转角的人行联络通道特殊环排版算法,结合掘进过程中地质扰动引起的轴线偏离问题,研究利用前后环管片的相对转角进行动态纠偏。结果表明,该排版策略不仅提升了通用楔形管片对线路几何特征的适应能力,还有效实现特殊环的合理过渡,提高隧道轴线回归设计路线精度。 展开更多
关键词 盾构法隧道 通用楔形管片 特殊环 排版 纠偏 算法
在线阅读 下载PDF
平洞内压力钢管立式组圆及安装技术
16
作者 孙学良 《四川水力发电》 2025年第4期38-41,共4页
通常,大型压力钢管的组圆是将瓦片运输至洞内在洞内进行立式组圆,首先采用埋弧自动焊焊接其外纵缝,然后拼焊相邻瓦片的加劲环,最后采用埋弧自动焊焊接其内纵缝。待在安装洞内完成3~10节压力钢管的组对和焊接后,其所有的纵缝和80%以上的... 通常,大型压力钢管的组圆是将瓦片运输至洞内在洞内进行立式组圆,首先采用埋弧自动焊焊接其外纵缝,然后拼焊相邻瓦片的加劲环,最后采用埋弧自动焊焊接其内纵缝。待在安装洞内完成3~10节压力钢管的组对和焊接后,其所有的纵缝和80%以上的环缝均采用埋弧自动焊焊接以提高压力钢管洞内组圆与焊接的效率。阐述了叶巴滩水电站在平洞内采用的压力钢管立式组圆及安装技术。 展开更多
关键词 压力钢管 瓦片 组圆台车 滚轮台车 加劲环 纵缝 立式组圆 组对 叶巴滩水电站
在线阅读 下载PDF
盾构隧道管片结构病害治理措施
17
作者 孙磊 《城市道桥与防洪》 2025年第7期252-256,共5页
近年来,我国城市轨道交通建设实现跨越式发展,目前已成为全球地铁运营里程最长的国家。然而,随着地铁运营时间的增加、周边地下空间的开发利用以及外部环境的不断变化,隧道管片结构往往会出现收敛变形、裂缝、渗漏水等病害。为保障地铁... 近年来,我国城市轨道交通建设实现跨越式发展,目前已成为全球地铁运营里程最长的国家。然而,随着地铁运营时间的增加、周边地下空间的开发利用以及外部环境的不断变化,隧道管片结构往往会出现收敛变形、裂缝、渗漏水等病害。为保障地铁隧道结构的安全与稳定,针对上述常见病害,采取针对性治理措施并分析治理效果。依托某工程实例,采用堵漏、裂缝修补、微扰动注浆、钢环永久加固等综合整治措施,提出了“微扰动注浆+钢环加固”组合技术路径,详细介绍了各项施工工艺及治理细节。 展开更多
关键词 盾构隧道 管片结构 病害治理 微扰动注浆 钢环加固
在线阅读 下载PDF
基于远程接管技术的气象运维系统优化研究
18
作者 孙平 张博涛 《计算机技术与发展》 2025年第12期98-106,共9页
为了提高气象业务系统的运维效率,增强系统的可用性和安全性,同时降低运维方面的成本,该文提出了一种基于远程接管技术的气象运维系统模型。该模型为提升气象运维系统的连续性与稳定性、缩短响应时间、降低人工与交通成本提供了新的解... 为了提高气象业务系统的运维效率,增强系统的可用性和安全性,同时降低运维方面的成本,该文提出了一种基于远程接管技术的气象运维系统模型。该模型为提升气象运维系统的连续性与稳定性、缩短响应时间、降低人工与交通成本提供了新的解决思路,不仅是实现气象业务自动化管理的重要支撑,也是增强行业服务能力的关键技术路径之一。它利用一个自定义的视频图像区域分割传输算法来实现,通过检测图像区域变化,可以进行差异化传输,从而达到节省带宽资源的目的。然后,把令牌桶和漏桶两种算法结合起来,用于流量控制,确保数据传输能够保持平稳。还设计了一个多通道环形存储区的数据结构,使用无锁并发机制以及异步数据流处理,以便提升气象观测数据的访问效率。在实验对比分析之后,发现该模型在提升运维效率和系统稳定性方面表现出了明显的优势。该文围绕远程接管技术在气象运维中的应用展开分析,重点阐述其关键技术改进与对比实验结果,并进一步提出未来气象运维系统的优化方向。 展开更多
关键词 远程接管技术 气象运维系统 环形数据区 分割传输算法 漏桶算法
在线阅读 下载PDF
盾构隧道纵向等效弯曲刚度的简化计算模型及影响因素分析 被引量:43
19
作者 钟小春 张金荣 +1 位作者 秦建设 朱伟 《岩土力学》 EI CAS CSCD 北大核心 2011年第1期132-136,共5页
盾构法隧道在国内的应用越来越广泛,早期建造的盾构隧道在工后沉降较大时出现较大的纵向变形问题,考虑隧道结构特征的设计模型及其刚度计算逐渐得到重视。在考虑管片螺栓等结构特征基础上,建立可考虑环缝张开的三维纵向结构计算模型。... 盾构法隧道在国内的应用越来越广泛,早期建造的盾构隧道在工后沉降较大时出现较大的纵向变形问题,考虑隧道结构特征的设计模型及其刚度计算逐渐得到重视。在考虑管片螺栓等结构特征基础上,建立可考虑环缝张开的三维纵向结构计算模型。研究结果表明,与管片环接缝相关的影响因素,如螺栓的数量、螺栓的预紧力以及管片环宽度对纵向弯曲刚度有效率影响较大,随着纵向螺栓数量和管片环宽度的增加而线性增加,随着螺栓预紧力的增加而非线性快速增加,而管片环的横向弯曲刚度有效率影响较小。研究成果为盾构隧道纵向设计提供了关键参数。 展开更多
关键词 盾构隧道 纵向弯曲刚度有效率 管片环宽度 螺栓预紧力
原文传递
上一页 1 2 11 下一页 到第
使用帮助 返回顶部