Aim: To assess the quality of high-resolution CT section planes(HRCT), multi-planar reformation(MPR) and 3-dimensional volume rendered computer tomography(3D-CTVR) were here used in the fine differential diagnosis of ...Aim: To assess the quality of high-resolution CT section planes(HRCT), multi-planar reformation(MPR) and 3-dimensional volume rendered computer tomography(3D-CTVR) were here used in the fine differential diagnosis of ossicular chain in the case of conductive hearing loss with intact tympanic membrane.Methods: Here, 17 cases of otosclerosis and 22 cases of ossicular chain deformity were selected. All patients had normal external ear canals,intact tympanic membranes, conductive hearing loss, type A tympanograms, and negative Gelle's tests. The respective radiological reports of the status of the ossicles via 3 protocols were compared to surgical findings. The quantitative assessments of the representation of different segments of the ossicular chain were based on a 3-point scoring system.Results: MPR and CTVR imaging both showed the integrity of whole ossicular chain well. MPR and CTVR imaging were found to be superior to section planes with respect to showing the superstructure of the stapes and malformations(P > 0.05).Conclusion: CTVR and MPR imaging were found to be better able to show the whole ossicular chain in the conductive hearing loss with normal tympanic membranes. Furthermore, the use of these techniques can have profound contributive value in the differential diagnosis of otosclerosis and ossicular chain absence or malformation.展开更多
A new type of displacement pile, the X-section cast-in-place concrete (XCC) pile, has recently been developed in China. Extensive field tests and laboratory experi- ments are undertaken to evaluate its performance a...A new type of displacement pile, the X-section cast-in-place concrete (XCC) pile, has recently been developed in China. Extensive field tests and laboratory experi- ments are undertaken to evaluate its performance and quantify the non-uniform deforma- tion effect (NUDE) of the X-shaped cross section during installation. This paper develops a simplified theoretical model that attempts to capture the NUDE. Based on the theory of complex variable plane elasticity, closed-form solutions of the stress and displacement for the X-shaped cavity boundary value problem are given. Subsequently, the analytical solution is used to evaluate the NUDE, the concrete filling index (CFI), and the perimeter reduction coefficient of the XCC pile cross section. The computed results are compared with field test results, showing reasonable agreement. The present simplified theoretical model reveals the deformation mechanism of the X-shaped cavity and facilitates applica- tion of the newly developed XCC pile technique in geotechnical engineering.展开更多
This paper presents the fully differential cross sections (FDCS) for 102eV electron impact single ionization of helium for both the coplanar and perpendicular plane asymmetric geometries within the framework of dyna...This paper presents the fully differential cross sections (FDCS) for 102eV electron impact single ionization of helium for both the coplanar and perpendicular plane asymmetric geometries within the framework of dynamically screened three-Coulomb-wave theory. Comparisons are made with the experimental data and those of the three-Coulomb wave function model and second-order distorted-wave Born method. The angular distribution and relative heights of the present FDCS is found to be in very good agreement with the experimental data in the perpendicular plane geometry. It is shown that dynamical screening effects are significant in this geometry. Three-body coupling is expected to be weak in the coplanar geometry, although the precise absolute value of the cross section is still sensitive to the interaction details.展开更多
文摘Aim: To assess the quality of high-resolution CT section planes(HRCT), multi-planar reformation(MPR) and 3-dimensional volume rendered computer tomography(3D-CTVR) were here used in the fine differential diagnosis of ossicular chain in the case of conductive hearing loss with intact tympanic membrane.Methods: Here, 17 cases of otosclerosis and 22 cases of ossicular chain deformity were selected. All patients had normal external ear canals,intact tympanic membranes, conductive hearing loss, type A tympanograms, and negative Gelle's tests. The respective radiological reports of the status of the ossicles via 3 protocols were compared to surgical findings. The quantitative assessments of the representation of different segments of the ossicular chain were based on a 3-point scoring system.Results: MPR and CTVR imaging both showed the integrity of whole ossicular chain well. MPR and CTVR imaging were found to be superior to section planes with respect to showing the superstructure of the stapes and malformations(P > 0.05).Conclusion: CTVR and MPR imaging were found to be better able to show the whole ossicular chain in the conductive hearing loss with normal tympanic membranes. Furthermore, the use of these techniques can have profound contributive value in the differential diagnosis of otosclerosis and ossicular chain absence or malformation.
基金supported by the National Natural Science Foundation of China(No.51420105013)the State Key Laboratory for Geomechanics and Deep Underground Engineering,China University of Mining and Technology(No.SKLGDUEK1713)the Fundamental Research Funds for the Central Universities(Nos.106112017CDJXY200003 and 106112017CDJPT200001)
文摘A new type of displacement pile, the X-section cast-in-place concrete (XCC) pile, has recently been developed in China. Extensive field tests and laboratory experi- ments are undertaken to evaluate its performance and quantify the non-uniform deforma- tion effect (NUDE) of the X-shaped cross section during installation. This paper develops a simplified theoretical model that attempts to capture the NUDE. Based on the theory of complex variable plane elasticity, closed-form solutions of the stress and displacement for the X-shaped cavity boundary value problem are given. Subsequently, the analytical solution is used to evaluate the NUDE, the concrete filling index (CFI), and the perimeter reduction coefficient of the XCC pile cross section. The computed results are compared with field test results, showing reasonable agreement. The present simplified theoretical model reveals the deformation mechanism of the X-shaped cavity and facilitates applica- tion of the newly developed XCC pile technique in geotechnical engineering.
基金Project supported by the Natural Science Foundation of Shanxi Province,China (Grant No 20051008)the Science Foundation for Returnee of Shanxi Province of China (Grant No 02-16)
文摘This paper presents the fully differential cross sections (FDCS) for 102eV electron impact single ionization of helium for both the coplanar and perpendicular plane asymmetric geometries within the framework of dynamically screened three-Coulomb-wave theory. Comparisons are made with the experimental data and those of the three-Coulomb wave function model and second-order distorted-wave Born method. The angular distribution and relative heights of the present FDCS is found to be in very good agreement with the experimental data in the perpendicular plane geometry. It is shown that dynamical screening effects are significant in this geometry. Three-body coupling is expected to be weak in the coplanar geometry, although the precise absolute value of the cross section is still sensitive to the interaction details.