Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyze...Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyzed the fracture surface characteristics induced by supercritical carbon dioxide(SC-CO_(2))and water in open-hole and perforation completion conditions under triaxial stresses.A simple calculation method was proposed to quantitatively analyze the fracture surface area and roughness in macro-level based on three-dimensional(3D)scanning data.In micro-level,scanning electron micrograph(SEM)was used to analyze the features of fracture surface.The results showed that the surface area of the induced fracture increases with perforation angle for both SC-CO_(2)and water fracturing,and the surface area of SC-CO_(2)-induced fracture is 6.49%e58.57%larger than that of water-induced fracture.The fractal dimension and surface roughness of water-induced fractures increase with the increase in perforation angle,while those of SC-CO_(2)-induced fractures decrease with the increasing perforation angle.A considerable number of microcracks and particle peeling pits can be observed on SC-CO_(2)-induced fracture surface while there are more flat particle surfaces in water-induced fracture surface through SEM images,indicating that fractures tend to propagate along the boundary of the particle for SC-CO_(2)fracturing while water-induced fractures prefer to cut through particles.These findings are of great significance for analyzing fracture mechanism and evaluating fracturing stimulation performance.展开更多
This paper deals with detailed corrosion analysis of explanted devices. The study of total 6 different types of orthopedic metallic implant was carried out after collecting the clinical report from the doctors, who pe...This paper deals with detailed corrosion analysis of explanted devices. The study of total 6 different types of orthopedic metallic implant was carried out after collecting the clinical report from the doctors, who performed these implantations. The clinical report covered the purpose of implantation, body part where implantation was done, and physiological reasons of removal of implant. The metallurgical investigation to study corrosion and any other mechanical damage to the implant surface during their service period was done using the Scanning Electron Micrography. SEM presented in this paper reveals the presence of in-vitro corrosion and mechanical damage as well, which are corroborating well with clinical reports.展开更多
Permanent waving is very popular in Japan. Polypeptide chains (main chains) form the principal components of hair, and they are lined up longitudinally. Hair relaxation is also called straight permanent waving, and th...Permanent waving is very popular in Japan. Polypeptide chains (main chains) form the principal components of hair, and they are lined up longitudinally. Hair relaxation is also called straight permanent waving, and there are methods that change curly or wavy hair into straight hair. Hair damage as a result of winding, combing, and using high-temperature hairdressing irons is also often seen. By using scanning electron micrographs (SEM) we showed broken hairs and hair damage caused by permanent wave solutions. The hair damage is obvious when comparisons are made with the condition of the hair surface, condition of the cuticle, etc. Hair swelling by permanent wave solutions, manipulations such as winding, etc., inadequate rinsing with water, procedures on injured hair at the outset, etc., are considered possible reasons for any of these types of injury.展开更多
基金National Natural Science Foundation of China(Grant No.51804318)the China Postdoctoral Science Foundation Founded Project(Grant No.2019M650963)National Key Basic Research and Development Program of China(Grant No.2014CB239203).
文摘Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyzed the fracture surface characteristics induced by supercritical carbon dioxide(SC-CO_(2))and water in open-hole and perforation completion conditions under triaxial stresses.A simple calculation method was proposed to quantitatively analyze the fracture surface area and roughness in macro-level based on three-dimensional(3D)scanning data.In micro-level,scanning electron micrograph(SEM)was used to analyze the features of fracture surface.The results showed that the surface area of the induced fracture increases with perforation angle for both SC-CO_(2)and water fracturing,and the surface area of SC-CO_(2)-induced fracture is 6.49%e58.57%larger than that of water-induced fracture.The fractal dimension and surface roughness of water-induced fractures increase with the increase in perforation angle,while those of SC-CO_(2)-induced fractures decrease with the increasing perforation angle.A considerable number of microcracks and particle peeling pits can be observed on SC-CO_(2)-induced fracture surface while there are more flat particle surfaces in water-induced fracture surface through SEM images,indicating that fractures tend to propagate along the boundary of the particle for SC-CO_(2)fracturing while water-induced fractures prefer to cut through particles.These findings are of great significance for analyzing fracture mechanism and evaluating fracturing stimulation performance.
文摘This paper deals with detailed corrosion analysis of explanted devices. The study of total 6 different types of orthopedic metallic implant was carried out after collecting the clinical report from the doctors, who performed these implantations. The clinical report covered the purpose of implantation, body part where implantation was done, and physiological reasons of removal of implant. The metallurgical investigation to study corrosion and any other mechanical damage to the implant surface during their service period was done using the Scanning Electron Micrography. SEM presented in this paper reveals the presence of in-vitro corrosion and mechanical damage as well, which are corroborating well with clinical reports.
文摘Permanent waving is very popular in Japan. Polypeptide chains (main chains) form the principal components of hair, and they are lined up longitudinally. Hair relaxation is also called straight permanent waving, and there are methods that change curly or wavy hair into straight hair. Hair damage as a result of winding, combing, and using high-temperature hairdressing irons is also often seen. By using scanning electron micrographs (SEM) we showed broken hairs and hair damage caused by permanent wave solutions. The hair damage is obvious when comparisons are made with the condition of the hair surface, condition of the cuticle, etc. Hair swelling by permanent wave solutions, manipulations such as winding, etc., inadequate rinsing with water, procedures on injured hair at the outset, etc., are considered possible reasons for any of these types of injury.