Reliability allocation of computerized numerical controlled(CNC)lathes is very important in industry.Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate componen...Reliability allocation of computerized numerical controlled(CNC)lathes is very important in industry.Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components,which is not applicable in some conditions.Aiming at solving the problem of CNC lathes reliability allocating,a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA)is presented.Firstly,conventional reliability allocation methods are introduced.Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated.Subsequently,a cubic transformed function is established in order to overcome these limitations.Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence.Designers can choose appropriate transform amplitudes according to their requirements.Finally,a CNC lathe and a spindle system are used as an example to verify the new allocation method.Seven criteria are considered to compare the results of the new method with traditional methods.The allocation results indicate that the new method is more flexible than traditional methods.By employing the new cubic transformed function,the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods.展开更多
Dipole coupled nanomagnets controlled by the static Zeeman field can form various magnetic logic interconnects.However, the corner wire interconnect is often unreliable and error-prone at room temperature. In this stu...Dipole coupled nanomagnets controlled by the static Zeeman field can form various magnetic logic interconnects.However, the corner wire interconnect is often unreliable and error-prone at room temperature. In this study, we address this problem by making it into a reliable type with trapezoid-shaped nanomagnets, the shape anisotropy of which helps to offer the robustness. The building method of the proposed corner wire interconnect is discussed,and both its static and dynamic magnetization properties are investigated. Static micromagnetic simulation demonstrates that it can work correctly and reliably. Dynamic response results are reached by imposing an ac microwave field on the proposed corner wire. It is found that strong ferromagnetic resonance absorption appears at a low frequency. With the help of a very small ac field with the peak resonance frequency, the required static Zeeman field to switch the corner wire is significantly decreased by ~21 m T. This novel interconnect would pave the way for the realization of reliable and low power nanomagnetic logic circuits.展开更多
基金Supported by National Natural Science Foundation of China(Grant Nos.51135003,51205050,U1234208)Key National Science&Technology Special Project on"High-Grade CNC Machine Tools and Basic Manufacturing Equipments"(Grant No.2013ZX04011011)+1 种基金Research Fund for the Doctoral Program of Higher Education of China(Grant No.20110042120020)Fundamental Research Funds for the Central
文摘Reliability allocation of computerized numerical controlled(CNC)lathes is very important in industry.Traditional allocation methods only focus on high-failure rate components rather than moderate failure rate components,which is not applicable in some conditions.Aiming at solving the problem of CNC lathes reliability allocating,a comprehensive reliability allocation method based on cubic transformed functions of failure modes and effects analysis(FMEA)is presented.Firstly,conventional reliability allocation methods are introduced.Then the limitations of direct combination of comprehensive allocation method with the exponential transformed FMEA method are investigated.Subsequently,a cubic transformed function is established in order to overcome these limitations.Properties of the new transformed functions are discussed by considering the failure severity and the failure occurrence.Designers can choose appropriate transform amplitudes according to their requirements.Finally,a CNC lathe and a spindle system are used as an example to verify the new allocation method.Seven criteria are considered to compare the results of the new method with traditional methods.The allocation results indicate that the new method is more flexible than traditional methods.By employing the new cubic transformed function,the method covers a wider range of problems in CNC reliability allocation without losing the advantages of traditional methods.
基金Supported by the National Natural Science Foundation of China under Grant No 61302022
文摘Dipole coupled nanomagnets controlled by the static Zeeman field can form various magnetic logic interconnects.However, the corner wire interconnect is often unreliable and error-prone at room temperature. In this study, we address this problem by making it into a reliable type with trapezoid-shaped nanomagnets, the shape anisotropy of which helps to offer the robustness. The building method of the proposed corner wire interconnect is discussed,and both its static and dynamic magnetization properties are investigated. Static micromagnetic simulation demonstrates that it can work correctly and reliably. Dynamic response results are reached by imposing an ac microwave field on the proposed corner wire. It is found that strong ferromagnetic resonance absorption appears at a low frequency. With the help of a very small ac field with the peak resonance frequency, the required static Zeeman field to switch the corner wire is significantly decreased by ~21 m T. This novel interconnect would pave the way for the realization of reliable and low power nanomagnetic logic circuits.