期刊文献+
共找到301篇文章
< 1 2 16 >
每页显示 20 50 100
Operando quantitatively analyses of polarizations in all-vanadium flow batteries 被引量:1
1
作者 Zhenyu Wang Jing Sun +8 位作者 Jiadong Shen Zixiao Guo Xiaosa Xu Jin Li Jiayou Ren Yiju Li Tianshuai Wang Xinzhuang Fan Tianshou Zhao 《Journal of Energy Chemistry》 2025年第6期178-184,I0005,共8页
All-vanadium flow batteries(VFBs)are one of the most promising large-scale energy storage technologies.Conducting an operando quantitative analysis of the polarizations in VFBs under different conditions is essential ... All-vanadium flow batteries(VFBs)are one of the most promising large-scale energy storage technologies.Conducting an operando quantitative analysis of the polarizations in VFBs under different conditions is essential for developing high power density batteries.Here,we employ an operando decoupling method to quantitatively analyze the polarizations in each electrochemical and chemical reaction of VFBs under different catalytic conditions.Results show that the reduction reaction of V^(3+)presents the largest activation polarization,while the reduction reaction of VO_(2)^(+)primarily contributes to concentration polarizations due to the formation of the intermediate product V_(2)O_(3)^(3+).Additionally,it is found that the widely used electrode catalytic methods,incorporating oxygen functional groups and electrodepositing Bi,not only enhance the reaction kinetics but also exacerbate concentration polarizations simultaneously,especially during the discharge process.Specifically,in the battery with the high oxygen-containing electrodes,the negative side still accounts for the majority of activation loss(75.3%)at 200 mA cm^(-2),but it comes down to 36,9% after catalyzing the negative reactions with bismuth.This work provides an effective way to probe the limiting steps in flow batteries under various working conditions and offers insights for effectively enhancing battery performance for future developments. 展开更多
关键词 Vanadium flow battery quantitative analysis Polarization Oxygen functional groups BISMUTH
在线阅读 下载PDF
Quantitative insight into fracture distribution during supercritical CO_(2)fracturing in tight sandstone formation 被引量:1
2
作者 Bing Yang Hai Huang +5 位作者 Qian-Qian Ren Hai-Zhu Wang Bin Wang Jun Ni Yong Zheng Wen-Tong Zhang 《Petroleum Science》 2025年第4期1670-1685,共16页
Supercritical CO_(2)(SC-CO_(2))fracturing stands out a promising waterless stimulation technique in the development of unconventional resources.While numerous studies have delved into the inducedfracture mechanism of ... Supercritical CO_(2)(SC-CO_(2))fracturing stands out a promising waterless stimulation technique in the development of unconventional resources.While numerous studies have delved into the inducedfracture mechanism of SC-CO_(2),the small scale of rock samples and synthetic materials used in many studies have limited a comprehensive understanding of fracture propagation in unconventional formations.In this study,cubic tight sandstone samples with dimensions of 300 mm were employed to conduct SC-CO_(2)fractu ring experiments under true-triaxial stre ss conditions.The spatial morphology and quantitative attributes of fracture induced by water and SC-CO_(2)fracturing were compared,while the impact of in-situ stress on fracture propagation was also investigated.The results indicate that the SCCO_(2)fracturing takes approximately ten times longer than water fracturing.Furthermore,under identical stress condition,the breakdown pressure(BP)for SC-CO_(2)fracturing is nearly 25%lower than that for water fracturing.A quantitative analysis of fracture morphology reveals that water fracturing typically produces relatively simple fracture pattern,with the primary fracture distribution predominantly controlled by bedding planes.In contrast,SC-CO_(2)fracturing results in a more complex fracture morphology.As the differential of horizontal principal stress increases,the BP for SC-CO_(2)fractured rock exhibits a downward trend,and the induced fracture morphology becomes more simplified.Moreover,the presence of abnormal in-situ stress leads to a further increase in the BP for SC-CO_(2)fracturing,simultaneously enhancing the development of a more conductive fracture network.These findings provide critical insights into the efficiency and behavior of SC-CO_(2)fracturing in comparison to traditional water-based fracturing,offering valuable implication for its potential applications in unconventional reservoirs. 展开更多
关键词 Supercritical CO_(2) True-triaxial fracturing Tight sandstone Fracture propagation quantitative analysis
原文传递
Quantitative Strengthening Evaluation of Mg-Zn-Y Alloys Containing Icosahedral Quasi-Crystalline Phase
3
作者 Wang Yingnan Meng Xiaokai Guo Junhong 《稀有金属材料与工程》 北大核心 2025年第3期612-617,共6页
Mg-4.8Zn-0.8Y,Mg-18Zn-3Y,Mg-15Zn-5Y,Mg-30Zn-5Y and Mg-42Zn-7Y(wt%)alloys containing icosahedral quasicrystalline phases were prepared using the ordinary solidification method.The impact of Mg matrix porosity on the te... Mg-4.8Zn-0.8Y,Mg-18Zn-3Y,Mg-15Zn-5Y,Mg-30Zn-5Y and Mg-42Zn-7Y(wt%)alloys containing icosahedral quasicrystalline phases were prepared using the ordinary solidification method.The impact of Mg matrix porosity on the tensile strength and hardness of the alloys was studied.The porosity of the Mg matrix was quantitatively assessed using scanning electron microscope and Image-Pro Plus 6.0 software.Tensile tests were conducted at room temperature.Results show that the maximum tensile strength of the alloy is 175.56 MPa,with a corresponding Mg matrix porosity of 76.74%.Through fitting analysis,it is determined that the maximum tensile strength is achieved when the porosity of the Mg matrix is 64.87%.The microhardness test results indicate a gradual decrease in alloy hardness with increasing the porosity of Mg matrix.This study provides an effective quantitative analysis method for enhancing the mechanical properties of magnesium alloys. 展开更多
关键词 Mg-Zn-Y alloy Mg matrix porosity mechanical properties quantitative analysis
原文传递
MITRE ATT&CK-Driven Threat Analysis for Edge-IoT Environment and a Quantitative Risk Scoring Model
4
作者 Tae-hyeon Yun Moohong Min 《Computer Modeling in Engineering & Sciences》 2025年第11期2707-2731,共25页
The dynamic,heterogeneous nature of Edge computing in the Internet of Things(Edge-IoT)and Industrial IoT(IIoT)networks brings unique and evolving cybersecurity challenges.This study maps cyber threats in Edge-IoT/IIoT... The dynamic,heterogeneous nature of Edge computing in the Internet of Things(Edge-IoT)and Industrial IoT(IIoT)networks brings unique and evolving cybersecurity challenges.This study maps cyber threats in Edge-IoT/IIoT environments to the Adversarial Tactics,Techniques,and Common Knowledge(ATT&CK)framework by MITRE and introduces a lightweight,data-driven scoring model that enables rapid identification and prioritization of attacks.Inspired by the Factor Analysis of Information Risk model,our proposed scoring model integrates four key metrics:Common Vulnerability Scoring System(CVSS)-based severity scoring,Cyber Kill Chain–based difficulty estimation,Deep Neural Networks-driven detection scoring,and frequency analysis based on dataset prevalence.By aggregating these indicators,the model generates comprehensive risk profiles,facilitating actionable prioritization of threats.Robustness and stability of the scoring model are validated through non-parametric correlation analysis using Spearman’s and Kendall’s rank correlation coefficients,demonstrating consistent performance across diverse scenarios.The approach culminates in a prioritized attack ranking that provides actionable guidance for risk mitigation and resource allocation in Edge-IoT/IIoT security operations.By leveraging real-world data to align MITRE ATT&CK techniques with CVSS metrics,the framework offers a standardized and practically applicable solution for consistent threat assessment in operational settings.The proposed lightweight scoring model delivers rapid and reliable results under dynamic cyber conditions,facilitating timely identification of attack scenarios and prioritization of response strategies.Our systematic integration of established taxonomies with data-driven indicators strengthens practical risk management and supports strategic planning in next-generation IoT deployments.Ultimately,this work advances adaptive threat modeling for Edge/IIoT ecosystems and establishes a robust foundation for evidence-based prioritization in emerging cyber-physical infrastructures. 展开更多
关键词 MITRE ATT&CK edge environment IOT threat analysis quantitative analysis deep neural network CVSS risk assessment scoring model
在线阅读 下载PDF
Noninvasive prediction of Ki-67 expression in pancreatic cancer via contrast-enhanced ultrasound quantitative parameters:A diagnostic model study
5
作者 Zi-Yi Yang Wei-Na Wan +3 位作者 Lei Zhao Si-Nong Li Zhe Liu Liang Sang 《World Journal of Gastrointestinal Oncology》 2025年第6期253-269,共17页
BACKGROUND The expression level of Ki-67 and the degree of differentiation in pancreatic cancer determine tumor aggressiveness and patient prognosis,which holds significant implications for clinical decision-making.A ... BACKGROUND The expression level of Ki-67 and the degree of differentiation in pancreatic cancer determine tumor aggressiveness and patient prognosis,which holds significant implications for clinical decision-making.A major challenge in preoperative pancreatic ductal adenocarcinoma management is predicting tumor malignancy.Contrast-enhanced ultrasound(CEUS),a dynamic imaging technique based on blood pool visualization,can reveal lesion vasculature and provide quantitative perfusion data reflecting angiogenesis.By tracking contrast agent kinetics,CEUS offers non-invasive insights into tumor vascularization,helping assess malig-nancy potential.AIM To investigate the correlation between Ki-67 and pancreatic cancer differentiation using CEUS quantitative parameters and evaluated their diagnostic accuracy.METHODS This retrospective study analyzed pancreatic cancer patients who underwent CEUS and pathological confirmation.Pathological differentiation,clinical data,and quantitative CEUS parameters[maximum intensity(IMAX),rise time(RT),rise slope 50%(Rs50),rise slope 10%-90%(Rs1090),etc.]were collected.Based on Ki-67 expression(<50%vs≥50%),patients were divided into low-and high-expression groups.The study evaluated correlations between Ki-67 expression,differentiation degree,and CEUS quantitative parameters to assess tumor aggressiveness.RESULTS Among 54 patients(25 high Ki-67,29 low Ki-67),significant differences(P<0.05)were observed in Rs50,IMAX,wash-out area under the curve(WoutAUC),wash-in and out area under curve,and Rs1090 between high and low Ki-67 groups.High-expression patients showed elevated Rs50,IMAX,WoutAUC,and area under the curve(AUC),while RT and falling slope 50%(Fs50)were lower.Rs1090 demonstrated the highest diagnostic accuracy(AUC=0.863,sensitivity=0.92,specificity=0.759).Fs50 was effective in low Ki-67 detection(AUC=0.838).No correlation was found between enhancement patterns and Ki-67 or differentiation.CONCLUSION CEUS parameters(Rs50,IMAX,WoutAUC,Rs1090)strongly correlate with Ki-67,aiding non-invasive pancreatic cancer assessment.Rs1090/IMAX predict high Ki-67;Fs50 identifies low Ki-67,supporting CEUS for tumor aggressiveness evaluation. 展开更多
关键词 Contrast-enhanced ultrasound Pancreatic cancer quantitative analysis Ki-67 index Pathological differentiation degree
暂未订购
Cryptocurrency Volatility and Its Impact on Emerging Markets: Quantitative Analysis
6
作者 Xinyang Kray Wang 《Economics World》 2025年第2期106-112,共7页
Cryptocurrency,a booming decentralised asset designed based on the blockchain architecture,is particularly important to the market at the present time by studying the volatility risk of cryptocurrencies.In this paper,... Cryptocurrency,a booming decentralised asset designed based on the blockchain architecture,is particularly important to the market at the present time by studying the volatility risk of cryptocurrencies.In this paper,we empirically analyse the volatility risk of cryptocurrencies through quantitative analysis models,comprehensively using the Markov state transition GARCH model with skewed distribution(Skew-MSGARCH)and the autoregressive conditional volatility density ARJI model introducing the Poisson jump factor,and selecting the earliest developed and the most mature currency price volatility daily return series,to deeply explore the volatility risk of digital cryptocurrencies.risk.Finally,it can be seen through in-depth analyses that the expectation factor and information inducement are the main reasons leading to the exacerbation of the volatility risk of digital cryptocurrencies.It is recommended that this situation be optimised and improved in terms of the value function of digital cryptocurrencies themselves and the implementation of systematic risk management and regulatory innovation.As an important component of the digital economy,blockchain technology can effectively regulate and improve the volatility of digital cryptocurrencies under macroeconomic policies,thereby maintaining the security and stability of emerging financial markets. 展开更多
关键词 cryptocurrency VOLATILITY emerging markets quantitative analysis
在线阅读 下载PDF
Quantitative Analysis of the Policy of Centralized Drug Procurement Based on PMC Index Model
7
作者 Duan Xiaoxiang Wang Shuling 《Asian Journal of Social Pharmacy》 2025年第3期222-235,共14页
Objective To quantitatively analyze the policy of centralized drug procurement centralized drug procurement in order to provide reference for the subsequent policy formulation and improvement.Methods Text mining metho... Objective To quantitatively analyze the policy of centralized drug procurement centralized drug procurement in order to provide reference for the subsequent policy formulation and improvement.Methods Text mining method was used to process 15 centralized drugs procurement policies issued at the national level during 2015-2022,and a PMC index evaluation model of centralized drug procurement policies was established.Then,15 centralized drug procurement policies were quantitatively analyzed from the overall and comparative perspective through an evaluation model.Results and Conclusion The average PMC index of 15 centralized drug procurement policies was 6.95,which was acceptable on the whole.Among them,eight were excellent and seven were acceptable.As to the first-order variables,the centralized drugs procurement policy still lacks incentives and constraints.The comparative results show that there are differences in the content and structure of policies,but they are strongly related to each other.Chinese centralized drug procurement policy has been basically formed,which is closely related to medical insurance and medical policies.However,it is still necessary to pay attention to the structure of the policy to ensure the elaboration of the policy content. 展开更多
关键词 centralized drug procurement PMC index POLICY quantitative analysis
暂未订购
Quantitative Effects of Velocity and Residual Pressure Level on Aerodynamic Noise of Ultra-High-Speed Maglev Trains
8
作者 Lanxi Zhang Yuming Peng Yudong Wu 《Fluid Dynamics & Materials Processing》 2025年第1期205-220,共16页
The challenge of aerodynamic noise is a key obstacle in the advancement of low-pressure tube ultra-high-speed maglev transportation,demanding urgent resolution.This study utilizes a broadband noise source model to per... The challenge of aerodynamic noise is a key obstacle in the advancement of low-pressure tube ultra-high-speed maglev transportation,demanding urgent resolution.This study utilizes a broadband noise source model to perform a quantitative analysis of the aerodynamic noise produced by ultra-high-speed maglev trains operating in low-pressure environments.Initially,an external flow field calculation model for the ultra-high-speed maglev train is presented.Subsequently,numerical simulations based on the broadband noise source model are used to examine the noise characteristics.The impact of the train speed and pressure level on noise generation is investigated accordingly.Subsequently,a correlation formula is derived.The results reveal that the amplitude of sound source changes in the streamlined region of the head and tail cars of the train is large,and the amplitude of changes for the middle car is smaller.The noise source strength increases with speed,with a quadrupole noise source becoming dominant when the train speed exceeds 600 km/h.At a speed of 1000 km/h,the noise source intensity from the streamlined area at the rear of the train overcomes that at the front.Furthermore,the noise source decreases as the pressure level in the tube decreases.When the pressure level drops to 0.01 atm,the quadrupole noise source intensity of a train running at 600 km/h significantly weakens and falls below that of the dipole noise source. 展开更多
关键词 Low-pressure tube aerodynamic noise train speed quantitative analysis
在线阅读 下载PDF
Ultra-simplified design and quantitative analysis for the optical system of compact laser-induced breakdown spectroscopy
9
作者 Jiujiang YAN Ke LIU +3 位作者 Jinxiu MA Yang LI Kailong LI Hongwei WEI 《Plasma Science and Technology》 2025年第3期87-93,共7页
Optimization and simplification of optical systems represent a milestone in advancing the development of handheld and portable laser-induced breakdown spectroscopy(LIBS)systems towards smaller,more integrated forms.Th... Optimization and simplification of optical systems represent a milestone in advancing the development of handheld and portable laser-induced breakdown spectroscopy(LIBS)systems towards smaller,more integrated forms.This research,for the first time,conducted a comprehensive optimization design and comparative analysis of three compact LIBS system optical paths:the paraxial optical path(OP),the off-axis OP,and the reflective OP.The differences in spectral intensity and stability among these paths were revealed,providing a scientific basis for selecting the optimal OP for LIBS systems.The research found that the paraxial OP excels in spectral performance and quantitative analysis accuracy,making it the preferred choice for compact LIBS systems.Specifically,the paraxial OP significantly enhances spectral intensity,achieving a 6 times improvement over the off-axis OP and an even more remarkable 150 times increase compared to the reflective OP,greatly enhancing detection sensitivity.Additionally,the relative standard deviation,spectral stability index,maintains a consistently low level,ranging from 10.9%to 13.4%,significantly outperforming the other two OPs and ensuring the reliability of analytical results.In the field of quantitative analysis,the paraxial OP also demonstrates higher accuracy,precision,and sensitivity,comparing to other OPs.The quantitative analysis models for Si,Cu,and Ti elements exhibit excellent fitting,providing users with high-quality quantitative analysis results that are of great significance for applications in material science,environmental monitoring,industrial inspection,and other fields.In summary,this study not only confirms the enormous application potential of the paraxial OP in compact LIBS systems but also provides valuable practical experience and theoretical support for the miniaturization and integration of LIBS systems.Looking ahead,with continuous technological advancements,the design of the paraxial OP is expected to further propel the widespread adoption of LIBS technology in portable,on-site detection applications. 展开更多
关键词 compact LIBS optical path design spectral stability quantitative analysis
在线阅读 下载PDF
High-precision quantitative analysis of 3-nitro-1,2,4-triazol-5-one(NTO)concentration based on ATR-FTIR spectroscopy and machine learning
10
作者 Zhe Zhang Zhuowei Sun +4 位作者 Haoming Zou Xijuan Lv Ziyang Guo Shuai Zhao Qinghai Shu 《Defence Technology(防务技术)》 2025年第10期131-141,共11页
3-Nitro-1,2,4-triazol-5-one(NTO)is a typical high-energy,low-sensitivity explosive,and accurate concentration monitoring is critical for crystallization process control.In this study,a high-precision quantitative anal... 3-Nitro-1,2,4-triazol-5-one(NTO)is a typical high-energy,low-sensitivity explosive,and accurate concentration monitoring is critical for crystallization process control.In this study,a high-precision quantitative analytical model for NTO concentration in ethanol solutions was developed by integrating real-time ATR-FTIR spectroscopy with chemometric and machine learning techniques.Dynamic spectral data were obtained by designing multi-concentration gradient heating-cooling cycle experiments,abnormal samples were eliminated using the isolation forest algorithm,and the effects of various preprocessing methods on model performance were systematically evaluated.The results show that partial least squares regression(PLSR)exhibits superior generalization ability compared to other models.Vibrational bands corresponding to C=O and–NO_(2)were identified as key predictors for concentration estimation.This work provides an efficient and reliable solution for real-time concentration monitoring during NTO crystallization and holds significant potential for process analytical applications in energetic material manufacturing. 展开更多
关键词 ATR-FTIR spectroscopy Machine learning quantitative analysis
在线阅读 下载PDF
Qualitative and quantitative analysis of four different polarity fractions from Huang-Lian-Jie-Du-Decoction by HPLC-DAD-ESI-MS/MS and their related neuroprotective effects 被引量:6
11
作者 杨阳 赵海誉 +4 位作者 王宏洁 宋建芳 杨健 司南 边宝林 《Journal of Chinese Pharmaceutical Sciences》 CAS CSCD 2013年第4期334-341,共8页
Huang-Lian-Jie-Du-Decoction (HLJDD) has been widely used for the treatment of Alzheimer's disease (AD) in clinic. However, the relationship between its chemical profile and neuroprotective bioactivity was not cle... Huang-Lian-Jie-Du-Decoction (HLJDD) has been widely used for the treatment of Alzheimer's disease (AD) in clinic. However, the relationship between its chemical profile and neuroprotective bioactivity was not clearly clarified yet. In present study, the water extract of HLJDD and subsequent three polarity fractions divided by different reagents were investigated. A total of 17 chromatographic peaks were confirmed by comparison with standards and their UV, MS spectra. Among them, 11 major compounds were determined by HPLC-DAD method with good linear regression relationship (r2, 0.9994-0.9999), precisions (inter-day precision RSD, 0.79%-1.07%; intra-day precision RSD, 1.59%-2.10%), repeatability (RSD, 1.66%-3.67%), stability (RSD, 1.26%-4.77%) and recovery (95.24%-105.41%, RSD, 0.29%-2.69%). Furthermore, PC12 cells and primary neurons cells were used for the neuroprotective effective assessment of aforementioned four samples from HLJDD. 3"he total aqueous extract and n-butanol extract of HLJDD presented more significant effects than the other two parts. According to their quality and quantity determination results, iridoids and alkaloids have a positive correlation with the neuroprotective effectiveness of HLJDD. 展开更多
关键词 Huang-Lian-Jie-Du-Decoction Qualitative and quantitative analysis Neuroprotective effects
原文传递
Quantitative analysis of astragaloside IV in traditional Chinese medicine‘Huang-Qi-Si-Wu' Capsules by HPLC/UV 被引量:6
12
作者 张艳利 杨兴鑫 李晓妮 《Journal of Chinese Pharmaceutical Sciences》 CAS 2010年第3期223-228,共6页
A reliable and accurate HPLC/UV method was developed for the quantitative determination of astragaloside IV in 'Huang-Qi-Si-Wu' Capsules, a widely used prescription of traditional Chinese medicines (TCM). The chro... A reliable and accurate HPLC/UV method was developed for the quantitative determination of astragaloside IV in 'Huang-Qi-Si-Wu' Capsules, a widely used prescription of traditional Chinese medicines (TCM). The chromatographic separation conditions employed for HPLC/UV were optimized using a Hypersil-ODS column (250 mm^4.6 mm, 5.0 pm) with isocratic elution. Acetonitrile-water (32:68, v/v) were used as the mobile phase pumped at a flow rate of 1.0 mL/min and a detection wavelength at 203 nm was used. The method was fully validated with respect to linearity, precision, accuracy, specificity and robustness. The validated method was applied successfully to the quantification of astragaloside IV in the extract of 'Huang-Qi- Si-Wu' Capsules from different production batches. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis and quality control of 'Huang-Qi-Si-Wu' Capsules and other related botanical drugs. 展开更多
关键词 HPLC/UV quantitative analysis Astragaloside IV Radix Astragali 'Huang-Qi-Si-Wu' Capsules
原文传递
Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer 被引量:26
13
作者 Ying-Shi Sun Xiao-Yan Zhang +4 位作者 Yong Cui Lei Tang Xiao-Ting Li Ying Chen Xiao-Peng Zhang 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2013年第6期722-728,共7页
Objective: This study investigated the capability of dual-energy spectral computed tomography (CT) to quantitatively evaluate lung perfusion defects that are induced by central lung cancer. Methods: Thirty-two pat... Objective: This study investigated the capability of dual-energy spectral computed tomography (CT) to quantitatively evaluate lung perfusion defects that are induced by central lung cancer. Methods: Thirty-two patients with central lung cancer underwent CT angiography using spectral imaging. A univariate general linear model was conducted to analyze the variance of iodine concentration/CT value with three factors of lung fields. A paired t-test was used to compare iodine concentrations and CT values between the distal end of lung cancer and the corresponding area in the contralateral normal lung. Results: Iodine concentrations increased progressively in the far, intermediate and near ground sides in the normal lung fields at 0.60±0.28, 0.93±0.27 and 1.25±0.38 mg/mL, respectively (P〈0.001). The same trend was observed for the CT values [-(840.64±49.08), -(812.66±50.85) and -(760.83±89.17) HU, P〈0.001]. The iodine concentration (0.70±0.42 mg/mL) of the lung field in the distal end of lung cancer was significantly lower than the corresponding area in the contralateral normal lung (1.19±0.62 mg/mL) (t=-7.23, P〈0.001). However, the CT value of lung field in the distal end of lung cancer was significantly higher than the corresponding area in the contralateral normal lung [-(765.29±93.34) HU vs. -(800.07±76.18) HU, t=3.564, P=0.001]. Conclusions: Spectral CT imaging based on the spectral differentiation of iodine is feasible and can quantitatively evaluate pulmonary perfusion and identify perfusion defects that are induced by central lung cancer. Spectral CT seems to be a promising technique for the simultaneous evaluation of both morphological and functional lung information. 展开更多
关键词 SPECTRAL computed tomography (CT) quantitative analysis PERFUSION lung cancer
暂未订购
Qualitative and Quantitative Analysis of Alkaloids in Cortex Phellodendri by HPLC-ESI-MS/MS and HPLC-DAD 被引量:20
14
作者 ZHU Shuang-lai DOU Sheng-shan +6 位作者 LIU Xin-ru LIU Run-hui ZHANG Wei-dong HUANG Hong-lin ZHANG Yi HU Yao-hua WANG Shu-ping 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第1期38-44,共7页
A combined method of high performance liquid chromatograph-elecrtrospray-ionization mass spectrometer(HPLC-ESI-MS/MS) coupled with a photodiode array detector(HPLC-DAD) and principal component analysis(PCA) was ... A combined method of high performance liquid chromatograph-elecrtrospray-ionization mass spectrometer(HPLC-ESI-MS/MS) coupled with a photodiode array detector(HPLC-DAD) and principal component analysis(PCA) was applied to the qualitative and quantitative analyses of alkaloids in Cortex Phellodendri(CP) samples, and to the differentiation of two species of CP, Cortex Phellodendri Chinensis(CPC) and Cortex Phellodendri Amurensis(CPA). Twenty-two peaks appeared in the HPLC-MS base peak chromatogram of CP detected by the HPLC-ESI-MS/MS analysis, and the alkaloids were identified according to the MSn data, the known MS fragmentation rules and the literature data. Five alkaloids including berberine, palmatine, jatrorrhizine, phellodendrine and magnoflorine were simultaneously determinated by the HPLC-DAD. Berberine was the primary component in all CP samples, and the contents of berberine and palmatine were exploited to be two critical parameters for effective discrimination between the two species of CP. The average content of berberine in CPC(58.75 mg/g) was higher than that in CPA(9.16 mg/g), while the content of palmatine was less, only 0.25 mg/g in CPC and 4.19 mg/g in CPA. With the use of PCA, samples datasets were separated successfully into two different clusters corresponding to the two species, and berberine, pahnatine, phellodendrine and magnoflorine contribute most to the above mentioned calssifying . The proposed method oroved to be a useful tool in the aualitv control of Chinese herbal medicines. 展开更多
关键词 Cortex Phellodendri ALKALOID HPLC-ESI-MS/MS quantitative analysis Qualitative analysis Principal component analysis
在线阅读 下载PDF
Quantitative Assessment of Hydrocarbon Expulsion of Petroleum Systems in the Niuzhuang Sag, Bohai Bay Basin, East China 被引量:14
15
作者 PANGXiongqi LISumei +1 位作者 JINZhijunt BAIGuoping 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2004年第3期615-625,共11页
Based on a detailed survey of the distribution and organic geochemical characteristics of potential source rocks in the South Slope of the Niuzhuang Sag, Bohai Bay Basin, eastern China, a new approach to assess the am... Based on a detailed survey of the distribution and organic geochemical characteristics of potential source rocks in the South Slope of the Niuzhuang Sag, Bohai Bay Basin, eastern China, a new approach to assess the amount of hydrocarbons generated and expelled has been developed. The approach is applicable to evaluate hydrocarbons with different genetic mechanisms. The results show that the models for hydrocarbon generation and expulsion vary with potential source rocks, depending on thermal maturity, types of organic matter and paleoenvironment. Hydrocarbons are mostly generated and expelled from source rocks within the normal oil window. It was calculated that the special interval (algal-rich shales of the ES4 member formed in brackish environments) in the South Slope of the Niuzhuang Sag has a much higher potential of immature oil generation than the other intervals in the area. This suggests that hydrocarbons can definitely be generated in early diagenesis, especially under certain special geological settings. The proportion of hydrocarbons generated and expelled from the ES4 shales in the early diagenetic stage is up to 26.75% and 17.36%, respectively. It was also observed that laminated shales have a much higher expulsion efficiency than massive mudstones. In contrast, the special interval of the ES4 shales proposed from previous studies is probably not the whole rock for oil in the South Slope of the Niuzhuang Sag because of the small proportion of the gross volume and corresponding low percentage of hydrocarbons generated and expelled. A much lower expulsion efficiency of the source rock during the early stage relative to that within the normal oil window has been calculated. Our results indicate that the ES4 mudstones rather than the shales deposited in the Niuzhuang and Guangli Sag are the main source rocks for the oil discovered. 展开更多
关键词 Immature oil expulsion efficiency petroleum potential quantitative analysis source rock
在线阅读 下载PDF
Quantitative evaluation of diffusion-weighted magnetic resonance imaging of focal hepatic lesions 被引量:21
16
作者 Xi-Jie Sun Xian-Yue Quan +1 位作者 Fan-Heng Huang Yi-Kai Xu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第41期6535-6537,共3页
AIM: To explore the quantitative analysis of diffusionweighted magnetic resonance imaging (DWMRI) in differential diagnosis of focal hepatic lesions.METHODS: DWMRI was performed in 149 hepatic lesions, including hepat... AIM: To explore the quantitative analysis of diffusionweighted magnetic resonance imaging (DWMRI) in differential diagnosis of focal hepatic lesions.METHODS: DWMRI was performed in 149 hepatic lesions, including hepatocellular carcinoma (34 cases),hepatic metastases (37 cases), cavernous hemangioma (42 cases), hepatic cyst (36 cases). Apparent diffusion coefficient (ADC) values were evaluated using four different b values in different sequences. The ratio of ADC values of lesion/liver in hepatocellular carcinoma and hepatic metastases was also calculated.RESULTS: The mean ADC values of hepatic lesions were as follows: hepatocellular carcinoma (0.95 ± 0.11) × 10-3 mm2/s, hepatic metastasis (1.13 ± 0.21)× 10-3 mm2/s, cavernous hemangioma (1.86±0.36)×10-3 mm2/s,hepatic cyst(3.14±0.31)×10-3 mm2/s. The ratio of ADC values in lesion/liver in hepatocellular carcinoma was 0.91 ±0.11, being significantly different from that in hepatic metastasis (1.21 ± 0.18, P< 0.05).CONCLUSION: ADC values and quantitative analysis of focal hepatic lesions are of significant values in differential diagnosis of focal hepatic lesions. 展开更多
关键词 Diffusion-weighed magnetic resonance imaging Hepatic lesion quantitative analysis
暂未订购
Quantitative determination of AI-2 quorum-sensing signal of bacteria using high performance liquid chromatography–tandem mass spectrometry 被引量:10
17
作者 Fang Xu Xiangning Song +2 位作者 Peijie Cai Guoping Sheng Hanqing Yu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第2期204-209,共6页
Autoinducer 2(AI-2), an important bioactive by-product of the Lux S-catalyzed S-ribosylhomocysteine cleavage reaction in the activated-methyl-cycle, has been suggested to serve as a universal intra- and inter-specie... Autoinducer 2(AI-2), an important bioactive by-product of the Lux S-catalyzed S-ribosylhomocysteine cleavage reaction in the activated-methyl-cycle, has been suggested to serve as a universal intra- and inter-species signaling molecule. The development of reliable and sensitive methods for quantitative determination of AI-2 is highly desired.However, the chemical properties of AI-2 cause difficulty in its quantitative analysis.Herein, we report a high performance liquid chromatography-tandem mass spectrometric method that enables reproducible and sensitive measurement of AI-2 concentrations in complex matrixes. 4,5-Dimethylbenzene-1,2-diamine(DMBDM), an easy-to-obtain commercial reagent, was used for the derivatization treatment. The assay was linear in the concentration range of 1.0–1000 ng/m L(R^2= 0.999) and had a lower limit of quantification of0.58 ng/m L. The method exhibited several advantages, e.g., high selectivity, wide linear response range, and good sensitivity. Furthermore, the effectiveness of the method was further validated through measuring AI-2 concentrations in the cell-free culture supernatant from Escherichia coli wild type. 展开更多
关键词 Autoinducer-2 Quorum sensing Signal transduction HPLC–MS/MS quantitative analysis Escherichia coli wild type
原文传递
Change of choline compounds in sodium selenite-induced apoptosis of rats used as quantitative analysis by in vitro 9.4T MR spectroscopy 被引量:14
18
作者 Zhen Cao Lin-Ping Wu +3 位作者 Yun-Xia Li Yu-Bo Guo Yao-Wen Chen Ren-Hua Wu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第24期3891-3896,共6页
AIM: To study liver cell apoptosis caused by the toxicity of selenium and observe the alteration of choline compounds using in vitro 9.4T high resolution magnetic resonance spectroscopy. METHODS: Twenty male Wistar ra... AIM: To study liver cell apoptosis caused by the toxicity of selenium and observe the alteration of choline compounds using in vitro 9.4T high resolution magnetic resonance spectroscopy. METHODS: Twenty male Wistar rats were randomly divided into two groups. The rats in the treatment group were intraperitoneally injected with sodium selenite and the control group with distilled water. All rats were sacrifi ced and the livers were dissected. 1H-MRS data were collected using in vitro 9.4T high resolution magnetic resonance spectrometer. Spectra were processed using XWINNMR and MestRe-c 4.3. HE and TUNEL staining was employed to detect and confi rm the change of liver cells. RESULTS: Good 1H-MR spectra of perchloric acid extract from liver tissue of rats were obtained. The conventional metabolites were detected and assigned. Concentrations of different ingredient choline compounds in treatment group vs control group were as follows: total choline compounds,5.08 ± 0.97 mmol/L vs 3.81 ± 1.16 mmol/L (P = 0.05); and free choline,1.07 ± 0.23 mmol/L vs 0.65 ± 0.20 mmol/L (P = 0.00). However,there was no statistical signif icance between the two groups. The hepatic sinus and cellular structure of hepatic cells in treatmentgroup were abnormal. Apoptosis of hepatic cells was confi rmed by TUNEL assay. CONCLUSION: High dose selenium compounds can cause the rat liver lesion and induce cell apoptosis in vivo. High resolution 1H-MRS in vitro can detect diversified metabolism. The changing trend for different ingredient of choline compounds is not completely the same at early period of apoptosis. 展开更多
关键词 Apoptosis of liver cell Choline compounds Sodium selenite In vitro ^1H-MRS quantitative analysis
暂未订购
Discrimination of Metastatic from Non-metastatic Mesorectal Lymph Nodes in Rectal Cancer Using Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging 被引量:17
19
作者 于小平 文露 +2 位作者 侯静 王晖 卢强 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第4期594-600,共7页
Preoperative detection of lymph nodes(LNs) metastasis is always highly challenging for radiologists nowadays. The utility of quantitative dynamic contrast-enhanced magnetic resonance imaging(QDCE-MRI) in identifyi... Preoperative detection of lymph nodes(LNs) metastasis is always highly challenging for radiologists nowadays. The utility of quantitative dynamic contrast-enhanced magnetic resonance imaging(QDCE-MRI) in identifying LNs metastasis is not well understood. In the present study, 59 patients with histologically proven rectal carcinoma underwent preoperative QDCE-MRI. The short axis diameter ratio, long axis diameter ratio, short-to-long axis diameter ratio and QDEC-MRI parameters(Ktrans, Kep, fPV and Ve) values were compared between the non-metastatic(n=44) and metastatic(n=35) LNs groups based on pathological examination. Compared with the non-metastatic group, the metastatic group exhibited significantly higher short axis diameter(7.558±0.668 mm vs. 5.427±0.285 mm), Ktrans(0.483±0.198 min-1 vs. 0.218±0.116 min^-1) and Ve(0.399±0.118 vs. 0.203±0.096) values(all P〈0.05). The short-to-long axis diameter ratio, long axis diameter ratio, Kep and fPV values did not show significant differences between the two groups. In conclusion, our results showed that for LNs larger than 5 mm in rectal cancer, there are distinctive differences in the Ktrans and Ve values between the metastatic and non-metastatic LNs, suggesting that QDCE-MRI may be potentially helpful in identifying LNs status. 展开更多
关键词 rectal cancer lymph node dynamic contrast-enhanced magnetic resonance imaging quantitative analysis sensitivity and specificity
暂未订购
Quantitative Analysis of Moisture Effect on Black Soil Reflectance 被引量:8
20
作者 LIU Huan-Jun ZHANG Yuan-Zhi +4 位作者 ZHANG Xin-Le ZHANG Bai SONG Kai-Shan WANG Zong-Ming TANG Na 《Pedosphere》 SCIE CAS CSCD 2009年第4期532-540,共9页
Several studies have demonstrated that soil reflectance decreases with increasing soil moisture content, or increases when the soil moisture reaches a certain content; however, there are few analyses on the quantitati... Several studies have demonstrated that soil reflectance decreases with increasing soil moisture content, or increases when the soil moisture reaches a certain content; however, there are few analyses on the quantitative relationship between soil reflectance and its moisture, especially in the case of black soils in northeast China. A new moisture adjusting method was developed to obtain soil reflectance with a smaller moisture interval to describe the quantitative relationship between soil reflectance and moisture. For the soil samples with moisture contents ranging from air-dry to saturated, the changes in soil reflectance with soil moisture can be depicted using a cubic equation. Both moisture threshold (MT) and moisture inflexion (MI) of soil reflectance can also be determined by the equation. When the moisture range was smaller than MT, soil reflectance can be simulated with a linear model. However, for samples with different soil organic matter (OM), the parameters of the linear model varied regularly with the OM content. Based on their relationship, the soil moisture can be estimated from soil reflectance in the black soil region. 展开更多
关键词 black soil quantitative analysis remote sensing soil moisture spectral reflectance
在线阅读 下载PDF
上一页 1 2 16 下一页 到第
使用帮助 返回顶部