The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems.As groundwater flows ...The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems.As groundwater flows through an aquifer,its composition and temperature may variation dependent on the aquifer condition through which it flows.Thus,hydrologic investigations can also provide useful information about the subsurface geology of a region.But because such studies investigate processes that follow under the Earth's shallow,obtaining the information necessary to answer these questions is not continuously easy.Springs,which discharge groundwater table directly,afford to study subsurface hydrogeological processes.The present study of estimation of aquifer factors such as transmissivity(T)and storativity(S)are vital for the evaluation of groundwater resources.There are several methods to estimate the accurate aquifer parameters(i.e.hydrograph analysis,pumping test,etc.).In initial days,these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory.The simultaneous information on the hydraulic behavior of the well(borehole)that provides on this method,the reservoir and the reservoir boundaries,are important for efficient aquifer and well data management and analysis.The most common in-situ test is pumping test performed on wells,which involves the measurement of the fall and increase of groundwater level with respect to time.The alteration in groundwater level(drawdown/recovery)is caused due to pumping of water from the well.Theis(1935)was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer.It is essential to know the transmissivity(T=Kb,where b is the aquifer thickness;pumping flow rate,Q=TW(dh/dl)flow through an aquifer)and storativity(confined aquifer:S=bS_s,unconfined:S=S_y),for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer.The determination of aquifer's parameters is an important basis for groundwater resources evaluation,numerical simulation,development and protection as well as scientific management.For determining aquifer's parameters,pumping test is a main method.A case study shows that these techniques have been fast speed and high correctness.The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation.展开更多
The determination of aquifer parameters is the basis for groundwater resource evaluation,development and protection as well as scientific management. Pumping test is a main method to determine the aquifer parameters.H...The determination of aquifer parameters is the basis for groundwater resource evaluation,development and protection as well as scientific management. Pumping test is a main method to determine the aquifer parameters.However,the analytic methods can’t be used to describe the heterogeneous and spatial variant of the parameters in detail.The aquifer parameters derived from analytic methods may lead much uncertainty of groundwater resource evaluation.展开更多
Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady R...Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady Reynolds-averaged Navier-Stokes equations with the SST turbulence model were used to model the transient flow within the entire flow passage of a reversible pump-turbine with and without misaligned guide vanes during turbine model start-up. The unstable S-curve and its improvement by using misaligned guide vane were verified by model test and simulation. The transient flow calculations were used to clarify the variations of pressure pulse and internal flow behavior in the entire flow passage. The use of misaligned guide vanes can eliminate the S-curve characteristics of a pump-turbine, and can significantly increase the pressure pulse amplitude in the entire flow passage and the runner radial forces during start-up. The MGV only decreased the pulse amplitude on the guide vane suction side when the rotating speed was less than 50% rated speed. The hydraulic reason is that the MGV dramatically changed the flow patterns inside the entire flow passage, and destroyed the symmetry of the flow distribution inside the guide vane and runner.展开更多
The traditional testing method of a hydraulic pump requires a large amount of test data from a variety of pump working conditions. The test is usually time-consuming and energy-consu- ming. And the accurate characteri...The traditional testing method of a hydraulic pump requires a large amount of test data from a variety of pump working conditions. The test is usually time-consuming and energy-consu- ming. And the accurate characteristic curves of the pump were hardly obtained due to a limited a- mount and discreteness of the test data. In order to simplify the test procedure and improve the test accuracy, a novel method for measuring hydraulic pump operating characteristic based on multi-ele- ment nonlinear regression (NLMR) modeling is proposed in this paper. The main idea of this model- ing method is establishing a mathematical model to predict the performance parameters of the hy- draulic pump, only a small amount of test data is needed. Consequently, the pump operating charac- teristics in any working conditions are obtained. And the test results of the pump are easily charac- terized in the graphs, charts, tables and so on. The evaluations of the model are carried out and dis- cussed in this paper. The result shows that the test error of the novel method can be controlled to be about 0. 1%. Compared with the traditional test method, the proposed method reduces greatly the test time and the random error of the test data, and improves the efficiency and accuracy of the pump test.展开更多
In the mixed-flow pump design, the shape of the flow passage can directly affect the flow capacity and the internal flow, thus influencing hydraulic performance, cavitation performance and operation stability of the m...In the mixed-flow pump design, the shape of the flow passage can directly affect the flow capacity and the internal flow, thus influencing hydraulic performance, cavitation performance and operation stability of the mixed-flow pump. However, there is currently a lack of experimental research on the influence mechanism. Therefore, in order to analyze the effects of subtle variations of the flow passage on the mixed-flow pump performance, the frustum cone surface of the end part of inlet contraction flow passage of the mixed-flow pump is processed into a cylindrical surface and a test rig is built to carry out the hydraulic performance experiment. In this experiment, parameters, such as the head, the efficiency, and the shaft power, are measured, and the pressure fluctuation and the noise signal are also collected. The research results suggest that after processing the inlet flow passage, the head of the mixed-flow pump significantly goes down; the best efficiency of the mixed-flow pump drops by approximately 1.5%, the efficiency decreases more significantly under the large flow rate; the shaft power slightly increases under the large flow rate, slightly decreases under the small flow rate. In addition, the pressure fluctuation amplitudes on both the impeller inlet and the diffuser outlet increase significantly with more drastic pressure fluctuations and significantly lower stability of the internal flow of the mixed-flow pump. At the same time, the noise dramatically increases. Overall speaking, the subtle variation of the inlet flow passage leads to a significant change of the mixed-flow pump performance, thus suggesting a special attention to the optimization of flow passage. This paper investigates the influence of the flow passage variation on the mixed-flow pump performance by experiment, which will benefit the optimal design of the flow passage of the mixed-flow pump.展开更多
Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft su...Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft suction box and a siphon-type discharge passage with a vacuum breaker as the cutoff device was developed , which possesses such advantages as simple structure , reliable cutoff , and high energy performance.Taking some pumping stations as the case studies , in the light of the specified operation conditions , the hydraulic optimal design of the shaft-type tubular pumping system was determined and the optimized shape of the system was recommended.The performance prediction based on the computational fluid dynamics methodology was determined and the model test verification was conducted.The results show that the predicted data agree with the experimental head and efficiency so that both methods can be used to determine the performance of a real pumping station.Finally , the in-situ measurements of a pumping station during the commissioning period further verified that the shaft-type tubular pumping station with a siphon discharge passage is of higher efficiency , more reliable and stable.展开更多
文摘The origin and movement of groundwater are the fundamental questions that address both the temporal and spatial aspects of ground water run and water supply related issues in hydrological systems.As groundwater flows through an aquifer,its composition and temperature may variation dependent on the aquifer condition through which it flows.Thus,hydrologic investigations can also provide useful information about the subsurface geology of a region.But because such studies investigate processes that follow under the Earth's shallow,obtaining the information necessary to answer these questions is not continuously easy.Springs,which discharge groundwater table directly,afford to study subsurface hydrogeological processes.The present study of estimation of aquifer factors such as transmissivity(T)and storativity(S)are vital for the evaluation of groundwater resources.There are several methods to estimate the accurate aquifer parameters(i.e.hydrograph analysis,pumping test,etc.).In initial days,these parameters are projected either by means of in-situ test or execution test on aquifer well samples carried in the laboratory.The simultaneous information on the hydraulic behavior of the well(borehole)that provides on this method,the reservoir and the reservoir boundaries,are important for efficient aquifer and well data management and analysis.The most common in-situ test is pumping test performed on wells,which involves the measurement of the fall and increase of groundwater level with respect to time.The alteration in groundwater level(drawdown/recovery)is caused due to pumping of water from the well.Theis(1935)was first to propose method to evaluate aquifer parameters from the pumping test on a bore well in a confined aquifer.It is essential to know the transmissivity(T=Kb,where b is the aquifer thickness;pumping flow rate,Q=TW(dh/dl)flow through an aquifer)and storativity(confined aquifer:S=bS_s,unconfined:S=S_y),for the characterization of the aquifer parameters in an unknown area so as to predict the rate of drawdown of the groundwater table/potentiometric surface throughout the pumping test of an aquifer.The determination of aquifer's parameters is an important basis for groundwater resources evaluation,numerical simulation,development and protection as well as scientific management.For determining aquifer's parameters,pumping test is a main method.A case study shows that these techniques have been fast speed and high correctness.The results of parameter's determination are optimized so that it has important applied value for scientific research and geology engineering preparation.
文摘The determination of aquifer parameters is the basis for groundwater resource evaluation,development and protection as well as scientific management. Pumping test is a main method to determine the aquifer parameters.However,the analytic methods can’t be used to describe the heterogeneous and spatial variant of the parameters in detail.The aquifer parameters derived from analytic methods may lead much uncertainty of groundwater resource evaluation.
基金supported by the National Natural Science Foundation of China(51009077)State Key Laboratory of Hydroscience and Engineering(2014-KY-05)
文摘Experimental studies of a model pump-turbine S-curve characteristics and its improvement by misaligned guide vanes (MGV) were extended to prototype pump turbine through 3-D transient flow simulations. The unsteady Reynolds-averaged Navier-Stokes equations with the SST turbulence model were used to model the transient flow within the entire flow passage of a reversible pump-turbine with and without misaligned guide vanes during turbine model start-up. The unstable S-curve and its improvement by using misaligned guide vane were verified by model test and simulation. The transient flow calculations were used to clarify the variations of pressure pulse and internal flow behavior in the entire flow passage. The use of misaligned guide vanes can eliminate the S-curve characteristics of a pump-turbine, and can significantly increase the pressure pulse amplitude in the entire flow passage and the runner radial forces during start-up. The MGV only decreased the pulse amplitude on the guide vane suction side when the rotating speed was less than 50% rated speed. The hydraulic reason is that the MGV dramatically changed the flow patterns inside the entire flow passage, and destroyed the symmetry of the flow distribution inside the guide vane and runner.
基金Supported by the National Science & Technology Pillar Program During the 12th Five-Year Plan Period(2014BAF08B06)the Research Foundation of Beijing Institute of Technology20110601061)
文摘The traditional testing method of a hydraulic pump requires a large amount of test data from a variety of pump working conditions. The test is usually time-consuming and energy-consu- ming. And the accurate characteristic curves of the pump were hardly obtained due to a limited a- mount and discreteness of the test data. In order to simplify the test procedure and improve the test accuracy, a novel method for measuring hydraulic pump operating characteristic based on multi-ele- ment nonlinear regression (NLMR) modeling is proposed in this paper. The main idea of this model- ing method is establishing a mathematical model to predict the performance parameters of the hy- draulic pump, only a small amount of test data is needed. Consequently, the pump operating charac- teristics in any working conditions are obtained. And the test results of the pump are easily charac- terized in the graphs, charts, tables and so on. The evaluations of the model are carried out and dis- cussed in this paper. The result shows that the test error of the novel method can be controlled to be about 0. 1%. Compared with the traditional test method, the proposed method reduces greatly the test time and the random error of the test data, and improves the efficiency and accuracy of the pump test.
基金Supported by National Natural Science Foundation of China(Grant No.51176088)
文摘In the mixed-flow pump design, the shape of the flow passage can directly affect the flow capacity and the internal flow, thus influencing hydraulic performance, cavitation performance and operation stability of the mixed-flow pump. However, there is currently a lack of experimental research on the influence mechanism. Therefore, in order to analyze the effects of subtle variations of the flow passage on the mixed-flow pump performance, the frustum cone surface of the end part of inlet contraction flow passage of the mixed-flow pump is processed into a cylindrical surface and a test rig is built to carry out the hydraulic performance experiment. In this experiment, parameters, such as the head, the efficiency, and the shaft power, are measured, and the pressure fluctuation and the noise signal are also collected. The research results suggest that after processing the inlet flow passage, the head of the mixed-flow pump significantly goes down; the best efficiency of the mixed-flow pump drops by approximately 1.5%, the efficiency decreases more significantly under the large flow rate; the shaft power slightly increases under the large flow rate, slightly decreases under the small flow rate. In addition, the pressure fluctuation amplitudes on both the impeller inlet and the diffuser outlet increase significantly with more drastic pressure fluctuations and significantly lower stability of the internal flow of the mixed-flow pump. At the same time, the noise dramatically increases. Overall speaking, the subtle variation of the inlet flow passage leads to a significant change of the mixed-flow pump performance, thus suggesting a special attention to the optimization of flow passage. This paper investigates the influence of the flow passage variation on the mixed-flow pump performance by experiment, which will benefit the optimal design of the flow passage of the mixed-flow pump.
基金support by the 11th Five Year Key Project of China’s National Scientific Supporting Plan(Grant No.2006BAB04A03)the Hydraulic Engineering Project from the Water Resources Department of Jiangsu Province(Grant No.2010023)
文摘Based on the characteristics of large flow rate , low head , short annual operation time , and high reliability of the city flood-control pumping stations , a new-type shaft tubular pumping system featuring a shaft suction box and a siphon-type discharge passage with a vacuum breaker as the cutoff device was developed , which possesses such advantages as simple structure , reliable cutoff , and high energy performance.Taking some pumping stations as the case studies , in the light of the specified operation conditions , the hydraulic optimal design of the shaft-type tubular pumping system was determined and the optimized shape of the system was recommended.The performance prediction based on the computational fluid dynamics methodology was determined and the model test verification was conducted.The results show that the predicted data agree with the experimental head and efficiency so that both methods can be used to determine the performance of a real pumping station.Finally , the in-situ measurements of a pumping station during the commissioning period further verified that the shaft-type tubular pumping station with a siphon discharge passage is of higher efficiency , more reliable and stable.