期刊文献+
共找到21,962篇文章
< 1 2 250 >
每页显示 20 50 100
Advancements and applications of position-sensitive detector(PSD): a review 被引量:2
1
作者 Shaher Dwik G.Sasikala S.Natarajan 《Optoelectronics Letters》 EI 2024年第6期330-338,共9页
This paper presents a review of the position-sensitive detector(PSD) sensor, covering different types of PSD and recent works related to this field. Furthermore, it explains the theoretical concepts and provides infor... This paper presents a review of the position-sensitive detector(PSD) sensor, covering different types of PSD and recent works related to this field. Furthermore, it explains the theoretical concepts and provides information about its structure and principles of operation. Moreover, it includes the main information about the available commercial PSDs from different companies, along with a comparison between the common modules. The PSD features include high position resolution, fast response, and a wide dynamic range. These features make it suitable for various fields and applications, such as imaging, spectrometry, spectroscopy and others. 展开更多
关键词 Advancements and applications of position-sensitive detector a review PSD
原文传递
Flexible broadband WS_(2)/Si optical position-sensitive detector with high sensitivity and fast speed
2
作者 Yunjie Liu Yupeng Wu +5 位作者 Fuhai Guo Yingming Liu Shirong Zhao Siqi Li Weizhuo Yu Lanzhong Hao 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第6期1217-1224,共8页
Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the application... Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the applications of flexible PSDs have been limited.Therefore,we presented a flexible broadband PSD based on a WS_(2)/Si heterostructure for the first time.A scalable sputtering method was used to deposit WS_(2)thin films onto the etched ultrathin crystalline Si surface.The fabricated flexible PSD device has a broad spectral response in the wavelength range of 450-1350 nm,with a high position sensitivity of~539.8 mV·mm^(−1)and a fast response of 2.3μs,thanks to the strong light absorption,the built-in electrical field at the WS_(2)/Si interface,and facilitated transport.Furthermore,mechanical-bending tests revealed that after 200 mechanical-bending cycles,the WS_(2)/Si PSDs have excellent mechanical flexibility,stability,and durability,demonstrating the great potential in wearable PSDs with competitive performance. 展开更多
关键词 FLEXIBLE position-sensitive detectors WS^(2)heterostructure broad spectral response high sensitivity
在线阅读 下载PDF
Hybrid 2D/3D Graphitic Carbon Nitride-Based High-Temperature Position-Sensitive Detector
3
作者 Xuexia Chen Dongwen Yang +6 位作者 Xun Yang Qing Lou Zhiyu Liu Yancheng Chen Chaofan Lv Lin Dong Chongxin Shan 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第1期275-283,共9页
Ultraviolet position-sensitive detectors(PSDs)are expected to undergo harsh environments,such as high temperatures,for a wide variety of applications in military,civilian,and aerospace.However,no report on relevant PS... Ultraviolet position-sensitive detectors(PSDs)are expected to undergo harsh environments,such as high temperatures,for a wide variety of applications in military,civilian,and aerospace.However,no report on relevant PSDs operating at high temperatures can be found up to now.Herein,we design a new 2D/3D graphitic carbon nitride(g-C_(3)N_(4))/gallium nitride(GaN)hybrid heterojunction to construct the ultraviolet high-temperature-resistant PSD.The g-C_(3)N_(4)/GaN PSD exhibits a high position sensitivity of 355 mV mm^(-1),a rise/fall response time of 1.7/2.3 ms,and a nonlinearity of 0.5%at room temperature.The ultralow formation energy of-0.917 eV atom^(-1)has been obtained via the thermodynamic phase stability calculations,which endows g-C_(3)N_(4)with robust stability against heat.By merits of the strong built-in electric field of the 2D/3D hybrid heterojunction and robust thermo-stability of g-C_(3)N_(4),the g-C_(3)N_(4)/GaN PSD delivers an excellent position sensitivity and angle detection nonlinearity of 315 mV mm^(-1)and 1.4%,respectively,with high repeatability at a high temperature up to 700 K,outperforming most of the other counterparts and even commercial silicon-based devices.This work unveils the high-temperature PSD,and pioneers a new path to constructing g-C_(3)N_(4)-based harsh-environment-tolerant optoelectronic devices. 展开更多
关键词 graphitic carbon nitride high-temperature stability lateral photovoltaic effect position-sensitive detectors two-dimensional materials
在线阅读 下载PDF
Position-sensitive detectors based on two-dimensional materials 被引量:4
4
作者 Wenhui Wang Junpeng Lu Zhenhua Ni 《Nano Research》 SCIE EI CAS CSCD 2021年第6期1889-1900,共12页
Two-dimensional(2D)materials have attracted great attention in optoelectronics because of their unique structure,optical and electrical properties.Designing high-performance photodetectors and implementing their appli... Two-dimensional(2D)materials have attracted great attention in optoelectronics because of their unique structure,optical and electrical properties.Designing high-performance photodetectors and implementing their applications are eager to promote the development of 2D materials.Position-sensitive detector(PSD)is an optical inspection device for the precise measurements of position,distance,angle,and other relevant physical variables.It is a widely used component in the fields of tracking,aerospace,nanorobotics,and so forth.Essentially,PSD is also a photodetector based on the lateral photovoltaic effect(LPE).This article reviews recent progress in high-performance PSD based on 2D materials.The high-sensitive photodetectors and LPE involved in 2D photodetectors are firstly discussed.Then,we introduce the research progress of PSD based on 2D materials and analyze the carrier dynamics in different device structures.Finally,we summarize the functionalities and applications of PSD based on 2D materials,and highlight the challenges and opportunities in this research area. 展开更多
关键词 two-dimensional(2D)materials GRAPHENE PHOTOdetector lateral photovoltaic effect position-sensitive detector HETEROJUNCTION
原文传递
Ultrasensitive graphene-Si position-sensitive detector for motion tracking 被引量:5
5
作者 Wenhui Wang Kaiyang Liu +5 位作者 Jie Jiang Ruxia Du Litao Sun Wei Chen Junpeng Lu Zhenhua Ni 《InfoMat》 SCIE CAS 2020年第4期761-768,共8页
Motion tracking has attracted great attention in the fields of real-time tracking,nanorobotics,and targeted therapy.For achieving more accurate motion tracking,the highly sensitive position-sensitive detector(PSD)is d... Motion tracking has attracted great attention in the fields of real-time tracking,nanorobotics,and targeted therapy.For achieving more accurate motion tracking,the highly sensitive position-sensitive detector(PSD)is desirable.Here,we demonstrate a meliorated PSD based on graphene-Si heterojunction for motion tracking.The position sensitivity of PSD was improved by employing surface engineering of graphene.Through modulating the transport property of graphene,nearly 20-fold increase of sensitivity was achieved under weak light,and at the same time,the detection limit power was reduced to^2 nW.A motion tracking system was developed based on the improved PSD,and human arm swing was tracked,which demonstrated high sensitivity and real-time tracking capabilities of the PSD.In addition,the PSD can support up to^10 kHz high-frequency tracking.This work provides a new strategy for improving the performance of PSD,and promotes the development of two-dimensional materials in novel optoelectronic devices. 展开更多
关键词 GRAPHENE HETEROJUNCTION motion tracking oxygen plasma position-sensitive detectors
原文传递
Ga2O3 solar-blind position-sensitive detectors 被引量:3
6
作者 Kaiyong Li Xun Yang +6 位作者 Yongzhi Tian Yancheng Chen Chaonan Lin Zhenfeng Zhang Zhiyang Xu Jinhao Zang Chongxin Shan 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2020年第11期103-108,共6页
Monoclinic Ga2O3(β-Ga2O3)is a promising material for achieving solar-blind photodetection because of its unique characteristics,including its high breakdown electric field,radiation hardness,thermal and chemical stab... Monoclinic Ga2O3(β-Ga2O3)is a promising material for achieving solar-blind photodetection because of its unique characteristics,including its high breakdown electric field,radiation hardness,thermal and chemical stabilities,and intrinsic visible/solar-blind properties.Until now,several studies have investigated the development of high-performanceβ-Ga2O3 solar-blind photodetectors.However,these photodetectors can only detect the light intensity but not the light position.In this work,fourquadrant position-sensitive detectors(4Q-PSDs)were developed and demonstrated based onβ-Ga2O3.4Q-PSDs,comprising four identical metal-semiconductor-metal-structured photodetector components,demonstrate high uniformity,large signal-tonoise ratio,good ultraviolet/visible rejection ratio,and fast response/recovery time.Subsequently,the position of the illumination beam can be determined by analyzing the output signals of the four photodetector components.This work may indicate the promising application potential of the Ga2O3-based photodetectors in the fields of positioning,aligning,and monitoring the solarblind beams. 展开更多
关键词 gallium oxide solar-blind position-sensitive detectors
原文传递
Ultrasensitive broadband position-sensitive detector based on graphitic carbon nitride 被引量:2
7
作者 Xuexia Chen Xun Yang +6 位作者 Qing Lou Yongzhi Tian Zhiyu Liu Chaofan Lv Yancheng Chen Lin Dong Chong-Xin Shan 《Nano Research》 SCIE EI CSCD 2023年第1期1277-1285,共9页
As a typical two-dimensional material,graphitic carbon nitride(g-CN)has attracted great interest because of its distinctive electronic,optical,and catalytic properties.However,the absence of a feasible route toward la... As a typical two-dimensional material,graphitic carbon nitride(g-CN)has attracted great interest because of its distinctive electronic,optical,and catalytic properties.However,the absence of a feasible route toward large-area and high-quality films hinders its development in optoelectronics.Herein,high-quality g-CN films have been grown on Si substrate via a vapor-phase transport-assisted condensation method.The g-CN/Si heterojunction shows an obvious response to ultraviolet–visible-near infrared photons with a responsivity of 133 A·W−1,which is two orders of magnitude higher than the best value ever reported for g-CN photodetectors.A position-sensitive detector(PSD)has been developed using the lateral photovoltaic effect of the g-CN/Si heterojunction.The PSD shows a wide response spectrum ranging from 300 to 1,100 nm,and a position sensitivity and rise/decay time of 395 mV·mm−1 and 3.1/50μs,respectively.Moreover,the application of the g-CN/Si heterojunction photodetector in trajectory tracking and acoustic detection has been realized for the first time.This work unveils the potential of g-CN for large-area photodetectors,and prospects for their applications in trajectory tracking and acoustic detection. 展开更多
关键词 graphitic carbon nitride(g-CN) position-sensitive detector(PSD) lateral photovoltaic effect(LPE) HETEROJUNCTION trajectory tracking acoustic detection
原文传递
Electrostatic-lenses position-sensitive TOF MCP detector for beam diagnostics and new scheme for mass measurements at HIAF 被引量:12
8
作者 Jun-Hao Liu Zhuang Ge +7 位作者 Qian Wang Geng Wang Li-Na Sheng Wen-Wen Ge Xing Xu Peng Shuai Qi Zeng Bo Wu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期63-73,共11页
A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-ge... A foil–microchannel plate(MCP)detector,which uses electrostatic lenses and possesses both good position and timing resolutions,has been designed and simulated for beam diagnostics and mass measurements at the next-generation heavy-ion-beam facility HIAF in China.Characterized by low energy loss and good performances of timing and position measurements,it would be located at focal planes in fragment separator HFRS for position monitoring,beam turning,Bq measurement,and trajectory reconstruction.Moreover,it will benefit the building-up of a magnetic-rigidity–energy-loss–time-offlight(BqDETOF)method at HFRS for high-precision in-flight particle identification of radioactive isotope beams on an event-by-event basis.Most importantly,the detector can be utilized for in-ring TOF and position measurements,beam-line TOF measurements at two achromatic foci,and position measurements at a dispersive focus of HFRS,thus making it possible to use two complementary mass measurement methods[isochronous mass spectrometry at the storage ring SRing and magnetic-rigidity–time-of-flight(BqTOF)at the beam-line HFRS]in one single experimental run. 展开更多
关键词 MICROCHANNEL plate ELECTROSTATIC lenses detector position-sensitive TIME-OF-FLIGHT Mass measurements HIAF
暂未订购
Preliminary results of a Compton camera based on a single 3D position-sensitive CZT detector 被引量:5
9
作者 Yi-Lin Liu Jian-Qiang Fu +3 位作者 Yu-Lan Li Yuan-Jing Li Xu-Ming Ma Lan Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第10期210-220,共11页
A Compton camera prototype has been developed using a pixelated CZT detector with 4-by-4 pixels.Signals of the detector are read out by a VASTAT ASIC that is controlled by a self-developed DAQ board. The DAQ software ... A Compton camera prototype has been developed using a pixelated CZT detector with 4-by-4 pixels.Signals of the detector are read out by a VASTAT ASIC that is controlled by a self-developed DAQ board. The DAQ software is developed using LabVIEW, and the offline Compton imaging codes are written in C++. The prototype has been successfully calibrated, and its capabilities for source detection, spectroscopy, and Compton imaging have been demonstrated using a Cs-137 source.The angular resolution of the 662 keV line is 36° FWHM for the simple back-projection method and 9.6° FWHM for the MLEM reconstruction method. The system is ready to be extended to 11-by-11 pixels in the future, and a better imaging quality can be expected due to the better relative position resolution. 展开更多
关键词 COMPTON imaging 3D position-sensitive technique CZT detector
在线阅读 下载PDF
Response estimation and evaluation of direct-conversion dual-layer perovskite X-ray detectors:a numerical study with a cascaded signal model
10
作者 Han Cui Yu-Hang Tan +7 位作者 Xin Zhang Hao-Di Wu Ting Su Jiong-Tao Zhu Hai-Rong Zheng Dong Liang Xiang-Ming Sun Yong-Shuai Ge 《Nuclear Science and Techniques》 2026年第2期156-168,共13页
This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation ... This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs. 展开更多
关键词 X-ray imaging Dual-layer flat-panel detector Perovskite X-ray detector
在线阅读 下载PDF
Prototype of front-end electronics based on FPGA-ADC for TOF PET detector applications
11
作者 Song-Qing Liu Bo Wang +2 位作者 Wei-Wei Xu Xin-Sheng Wang Kun Hu 《Nuclear Science and Techniques》 2026年第2期134-142,共9页
Traditional digitizers for signal readout of PET detectors are based on commercial analog-to-digital converters(ADC).However,the cost and power consumption of an entire electronic readout system based on digitizers fo... Traditional digitizers for signal readout of PET detectors are based on commercial analog-to-digital converters(ADC).However,the cost and power consumption of an entire electronic readout system based on digitizers for a PET scanner are high.To address this problem,a soft-core ADC based on a field-programmable gate array(FPGA)was proposed.An FPGA-based ADC(FPGA-ADC)combines low loss and high performance.To achieve good performance,the FPGA-ADC requires three calibrations:time-to-digital converter(TDC)length calibration,TDC alignment calibration,and TDC-to-ADC calibration.A prototype front-end electronics based on FPGA-ADC was built to evaluate the performance of time-of-flight positron emission tomography(TOF PET)detectors.Each PET detector consists of a LYSO crystal single-ended coupled to a silicon photomultiplier(SiPM).The experimental results show that the full-width at half-maximum(FWHM)energy resolution for 511 keV gamma photons after saturation correction of the SiPM was 12.3%.The FWHM coincidence timing resolution(CTR)of the TOF PET detector with the readout of the front-end electronic prototype is 385.2 ps.FPGA-ADCbased front-end electronics are very promising for multichannel,low-cost,highly integrated,and power-efficient readout electronic systems for radiation detector applications. 展开更多
关键词 Front-end electronics Analog-to-digital converter Radiation detector PET FPGA
在线阅读 下载PDF
Unity-based virtual reality for detector and event visualization in JUNO experiment
12
作者 Kai-Xuan Huang Tian-Zi Song +4 位作者 Yu-Ning Su Cheng-Xin Wu Xue-Sen Wang Yu-Mei Zhang Zheng-Yun You 《Nuclear Science and Techniques》 2026年第4期127-138,共12页
Detector and event visualization are crucial components of high-energy physics(HEP)experimental software.Virtual reality(VR)technologies and multimedia development platforms,such as Unity,offer enhanced display effect... Detector and event visualization are crucial components of high-energy physics(HEP)experimental software.Virtual reality(VR)technologies and multimedia development platforms,such as Unity,offer enhanced display effects and flexible extensibility for visualization in HEP experiments.In this study,we present a VR-based method for detector and event displays in the Jiangmen Underground Neutrino Observatory(JUNO)experiment.This method shares the same detector geometry descriptions and event data model as those in the offline software and provides the necessary data conversion interfaces.The VR methodology facilitates an immersive exploration of the virtual environment in JUNO,enabling users to investigate the detector geometry,visualize event data,and tune the detector simulation and event reconstruction algorithms.Additionally,this approach supports applications in data monitoring,physics data analysis,and public outreach initiatives. 展开更多
关键词 Virtual reality Event display UNITY detector geometry JUNO
在线阅读 下载PDF
Preparation and measurement of an^(37)Ar source for liquid xenon detector calibration
13
作者 Xu‑Nan Guo Chang Cai +8 位作者 Fei Gao Yang Lei Kai‑Hang Li Chun‑Lei Su Ze‑Peng Wu Xiang Xiao Ling‑Feng Xie Yi‑Fei Zhao Xiao‑Peng Zhou 《Nuclear Science and Techniques》 2026年第1期202-211,共10页
We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-... We present the preparation and measurement of the radioactive isotope^(37)Ar,which was produced using thermal neutrons from a reactor,as a calibration source for liquid xenon time projection chambers.^(37)Ar is a low-energy calibration source with a half-life of 35.01 days,making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments.Radioactive isotope^(37)Ar was produced by irradiating ^(36)Ar with thermal neutrons.It was subsequently measured in a gaseous xenon time projection chamber(GXe TPC)to validate its radioactivity.Our results demonstrate that^(37)Ar is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors. 展开更多
关键词 ^(37)Ar Gaseous xenon detector LOW-ENERGY Calibration source
在线阅读 下载PDF
Superconducting nanowire single photon detector with efficiency over 90% at 2μm wavelength
14
作者 Zhen Wan Jia Huang +6 位作者 Guangzhao Xu Yu Ding Xiaoyu Liu Yiming Pan Hongxin Xu Hao Li Lixing You 《Chinese Physics B》 2026年第1期306-312,共7页
We here report a high system detection efficiency(SDE)superconducting single-photon detector(SSPD)at 2μm wavelength.The device integrates a SiO_(2)/Ta_(2)O_(5)distributed Bragg reflector(DBR)and a sandwich-structured... We here report a high system detection efficiency(SDE)superconducting single-photon detector(SSPD)at 2μm wavelength.The device integrates a SiO_(2)/Ta_(2)O_(5)distributed Bragg reflector(DBR)and a sandwich-structured double-layer NbN nanowire to enhance the optical absorption efficiency.A cold development technique is implemented to optimize the superconducting nanowires with sub-40-nm linewidths,thus enhancing the intrinsic detection efficiency(IDE).The fabricated SSPD shows an SDE exceeding 90% at 2μm wavelength.Moreover,the detector allows an operational working temperature of 2.2 K provided by a compact GM cryo-cooler.This detector delivers excellent performance at the 2μm wavelength,and its optimized structural design implies promising potential for extending detection toward longer infrared bands.It thus holds value for advancing high-sensitivity quantum technologies,mid-infrared optical communications,and dark matter detection research. 展开更多
关键词 superconducting single-photon detectors(SSPDs) system detection efficiency near infrared
原文传递
How Does Urban Public Transit Accessibility Affect Housing Prices?A Comprehensive Analysis with Geographical Detector Combined and Geographically Weighted Regression
15
作者 TANG Jingjing HAN Huiran +3 位作者 YANG Chengfeng XU Lingyi GENG Hui LI Lei 《Chinese Geographical Science》 2026年第1期127-143,共17页
The accessibility of urban public transit directly influences residents’quality of life,travel behavior,and social equity.Its correlation with housing prices has garnered significant attention across disciplines such... The accessibility of urban public transit directly influences residents’quality of life,travel behavior,and social equity.Its correlation with housing prices has garnered significant attention across disciplines such as geography,economics,and urban planning.Although much existing research focuses on the impact of individual transportation facilities on housing prices,there is a notable gap in comprehensive analyses that assess the influence of overall urban transit accessibility on housing market dynamics.This study selected the main urban area of Hefei,China,as a case to investigate the spatial distribution of housing prices and evaluate public transit accessibility in 2022.Employing techniques such as the optimized parameter geographical detector and local spatial regression models,the study aimed to elucidate the effects and underlying mechanisms of urban transit accessibility on housing prices.The findings revealed that:1)housing prices in Hefei exhibited a clustered spatial pattern,with high prices concentrated in the city center and lower prices in peripheral areas,forming three distinct high-price hotspots with a‘belt-like’distribution;2)public transit accessibility showed a‘coreperiphery’structure,with accessibility declining in a‘circumferential’pattern around the city center.Based on the‘housing price-accessibility’dimension,four categories were identified:high price-high accessibility(37.25%),high price-low accessibility(19.07%),low price-high accessibility(21.95%),and low price-low accessibility(21.73%);3)the impact of transit accessibility on housing prices was spatially heterogeneous,with bus travel showing the strongest explanatory power(0.692),followed by automobile,subway,and bicycle travel.The interaction of these transportation modes generated a synergistic effect on housing price differentiation,with most influencing factors contributing more than 25%.These findings offer valuable insights for optimizing the spatial distribution of public transit infrastructure and improving both urban housing quality and residents’living standards. 展开更多
关键词 public transit accessibility housing prices geographically weighted regression geographical detector Hefei City China
在线阅读 下载PDF
Lattice Anchoring Stabilizesα-FAPbI_(3) Perovskite for High-Performance X-Ray Detectors
16
作者 Yu-Hua Huang Su-Yan Zou +5 位作者 Cong-Yi Sheng Yu-Chuang Fang Xu-Dong Wang Wei Wei Wen-Guang Li Dai-Bin Kuang 《Nano-Micro Letters》 2026年第1期337-354,共18页
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl... Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses. 展开更多
关键词 α-FAPbI_(3)perovskite Conjugated organic cation Lattice anchoring Phase stability X-ray detectors
在线阅读 下载PDF
Ultralow dark current soft X-ray detectors based on lead-free double perovskite Cs_(2)AgBiBr_(6)
17
作者 Long Cheng Lijuan Huang +15 位作者 Mulin Sun Ying Meng Yuan Li Tianyu Liu Pengju Tan Mingzhu Hu Huaqing Yang Xiaolan Ma Shunjie Yu Xiaohu Hou Yong Guan Junfa Zhu Xiaosong Liu Yu Li Shibing Long Qin Hu 《Journal of Semiconductors》 2026年第1期109-116,共8页
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi... Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors. 展开更多
关键词 soft X-ray detector lead-free double perovskite Cs_(2)AgBiBr_(6) ALLOYING IMAGING
在线阅读 下载PDF
VMFD:Virtual Meetings Fatigue Detector Using Eye Polygon Area and Dlib Shape Indicator
18
作者 Hafsa Sidaq Lei Wang +3 位作者 Sghaier Guizani Hussain Haider Ateeq Ur Rehman Habib Hamam 《Computers, Materials & Continua》 2026年第3期672-688,共17页
Numerous sectors,such as education,the IT sector,and corporate organizations,transitioned to virtual meetings after the COVID-19 crisis.Organizations now seek to assess participants’fatigue levels in online meetings ... Numerous sectors,such as education,the IT sector,and corporate organizations,transitioned to virtual meetings after the COVID-19 crisis.Organizations now seek to assess participants’fatigue levels in online meetings to remain competitive.Instructors cannot effectively monitor every individual in a virtual environment,which raises significant concerns about participant fatigue.Our proposed system monitors fatigue,identifying attentive and drowsy individuals throughout the online session.We leverage Dlib’s pre-trained facial landmark detector and focus on the eye landmarks only,offering a more detailed analysis for predicting eye opening and closing of the eyes,rather than focusing on the entire face.We introduce an Eye Polygon Area(EPA)formula,which computes eye activity from Dlib eye landmarks by measuring the polygonal area of the eye opening.Unlike the Eye Aspect Ratio(EAR),which relies on a single distance ratio,EPA adapts to different eye shapes(round,narrow,or wide),providing a more reliable measure for fatigue detection.The VMFD system issues a warning if a participant remains in a fatigued condition for 36 consecutive frames.The proposed technology is tested under multiple scenarios,including low-to high-lighting conditions(50-1400 lux)and both with and without glasses.This study builds an OpenCV application in Python,evaluated using the iBUG 300-W dataset,achieving 97.5%accuracy in detecting active participants.We compare VMFD with conventional methods relying on the EAR and show that the EPA technique performs significantly better. 展开更多
关键词 Fatigue detector human-computer interaction(HCI) eye blink active and inactive behavior online meeting automatic fatigue alert
在线阅读 下载PDF
A new method for position-sensitive measurement of beta surface contamination
19
作者 Yan-Tao Qu Hui Wang +4 位作者 Yang Liu Ling Chen Jie Hou Zhe Liu Ji-Zeng Ma 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第2期49-56,共8页
In this paper, we propose a new method for position-sensitive measurement of beta surface contamination. With a position-sensitive detector of enlarged sensitive detection area, accurate information of the contaminati... In this paper, we propose a new method for position-sensitive measurement of beta surface contamination. With a position-sensitive detector of enlarged sensitive detection area, accurate information of the contamination distribution can be obtained. The positionsensitive detection is based on a large-area plastic scintillator and the wavelength shifting(WLS) fibers and adopts the ‘‘light center of gravity'' method. Optical transmission of the detector is simulated with a preliminary detector model, and feasibility of the detector design and measurement method is evaluated using an experiment system.The simulation and experiment results at different beta-ray incident points on the scintillator surface show that there is a polynomial relationship between the average amplitude ratio of the output pulses from the two parallel WLS fibers in the same fiber layer and the relative distance from the incident point to the WLS fiber. 展开更多
关键词 BETA surface CONTAMINATION position-sensitive measurement WAVELENGTH SHIFTING fibers Plastic scintillator
在线阅读 下载PDF
RAA-DETECTOR布鲁氏菌核酸快速检测方法的建立及应用 被引量:1
20
作者 张雲龙 王靖雷 +8 位作者 朱亚杰 张明洁 康澳 周翔 魏凯 曹洪防 李强 王勇 苏峰 《畜牧兽医学报》 北大核心 2025年第10期5115-5124,共10页
本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试... 本研究旨在建立不依赖于专业设备的布鲁氏菌病高效快速检测体系,实现临床样本40 min内快速检测。首先比对不同布鲁氏菌的基因组,找到布鲁氏菌的核心共有序列,以布鲁氏菌S2菌株基因SEQ NO.6(CN 105018489A)为模板构建阳性质粒,用于后续试验;通过原核表达的方法分别表达CRISPR/AsCas12a和LwaCas13a蛋白;通过重组酶介导的等温核酸扩增技术(RAA)、体外表达技术结合AsCas12a/LwaCas13a的DETECTOR系统,优化高效检测体系、通过无限稀释法等进行检测。结果发现,设计的RAA引物能够有效扩增样本中的DNA片段,DETECTOR得到最佳反应的AsCas12a浓度为200 nmol·L^(-1),gRNA为200 nmol·L^(-1);Cas13a浓度为300 nmol·L^(-1),crRNA浓度为400 nmol·L^(-1);RAA-AsCas12a和RAA-LwaCas13a的检测体系的最佳反应时间为35 min,侧平流式纸条的最佳检测时间为20 min,细菌最低检测浓度为10 Copies·μL^(-1),且具有较好的检测特异性,临床样本的检测试验表明两种方法均有较好的重复性和检测精度,但LwaCas13a的精测精度更高,但二者无显著差异。该研究建立了2种RAA-CRISPR/Cas布鲁氏菌核酸快速检测体系,在临床上可获得较好的应用,RAA-LwaCas13a的检测方法精度更高。 展开更多
关键词 布鲁氏菌 RAA detector系统 SHERLOCK系统 AsCas12a LwaLwaCas13a
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部