An integrated laser diode driver(LDD) driving an edge-emitting laser diode was designed and fabricated by 0.35 μm BiCMOS technology. This paper proposes a scheme which combines the automatic power control loop and te...An integrated laser diode driver(LDD) driving an edge-emitting laser diode was designed and fabricated by 0.35 μm BiCMOS technology. This paper proposes a scheme which combines the automatic power control loop and temperature com-pensation for modulation current in order to maintain constant extinction ratio and average optical power. To implement tem-perature compensation for modulation current,a novel circuit which generates a PTAT current by using the injecting base current of a bipolar transistor in saturation region,and alternates the amplifier feedback loop(closed or not) to control the state of the current path is presented. Simulation results showed that programmed by choice of external resistors,the IC can provide modu-lation current from 5 mA to 85 mA with temperature compensation adjustments and independent bias current from 4 mA to 100 mA. Optical test results showed that clear eye-diagrams can be obtained at 155 Mbps,with the output optical power being nearly constant,and the variation of extinction ratio being lower than 0.7 dB.展开更多
It is need to establish site project department during the construction of electric power project.The head office should design and build the main structure,continually improve structure of project department,meantime...It is need to establish site project department during the construction of electric power project.The head office should design and build the main structure,continually improve structure of project department,meantime,positively apply principle of automatic control to improve the site management of electric power construction.In this article,the application strategy of principle of automatic control is analyzed focusing on the site work of electric power construction.展开更多
In order to optimize the allocation of power resources, ensure the safe and stable operation of the power system, maintain the coordinated development of the power grid and grid-connected power plants, and minimize li...In order to optimize the allocation of power resources, ensure the safe and stable operation of the power system, maintain the coordinated development of the power grid and grid-connected power plants, and minimize line losses. The power dispatching institution shall issue the bus voltage curve to the grid-connected power plants on a quarterly basis, which shall be used as the basis for the assessment of reactive auxiliary services. In order to maintain the target voltage value issued by the power grid, the power plant adopts automatic voltage control device (AVC), and realizes the automation and intelligence of power plant voltage adjustment by adjusting and controlling the reactive power of the excitation system to respond to the target voltage value of the power grid system.展开更多
This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multipl...This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.展开更多
Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the to...Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the topology, synchronization between nodes has become a critical issue which needs to be studied. The existing synchronization methods largely depend on the complex communication protocol. Therefore, this paper has proposed a method of automatic measurement and compensation of synchronization delay, and analyzed its operating principle and implementation procedure in detail. The results obtained from the experiments prove the proposed method to be correct, effective and practicable.展开更多
The application frequency of electric power automation technology is higher and higher. When electric power enterprises carry out automation construction, according to the actual development status, they carry out the...The application frequency of electric power automation technology is higher and higher. When electric power enterprises carry out automation construction, according to the actual development status, they carry out the distribution of new energy, which can improve the development level of China's electric power industry. Vigorously carry out the power supply and distribution automation control work;provide more development strategies for the power supply and distribution industry, aiming to provide technical basis for the future development of the power industry;improve the service level of the industry, but also provide technical power for social development.展开更多
Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal fac...Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal face and, on this basis, established an automatic control model of powered supports for the coal plough face. We introduced the working principle of the powered support control system of the plough at the mining face. We established three advanced characteristics of this control system: response speed, reliability and easy maintenance of the system. As well, we briefly introduced, the principal function of primary and subordinate controllers and the realization of the communication system by a Single Bus. Ten controllers were constructed and tested in our laboratorium. The results show that the control model is practical and meets actual conditions. It provides a theoretical basis for designing a comouter control system for a oowered support system of a plough at a mining face.展开更多
Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid...Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid planning and construction, and will make a heavy impact on the safe and reliable operation of power systems. To deal with the diff iculties of large scale wind power dispatch, this paper presents a new automatic generation control (AGC) scheme that involves the participation of wind farms. The scheme is based on ultra-short-term wind power forecast. The author establishes a generation output distribution optimization mode for the power system with wind farms and verif ies the feasibility of the scheme by an example.展开更多
Vehicle hydraulic pump station, often work environment is poor, the environment temperature difference is very big, the natureof the hydraulic oil is affected by temperature is very big, a lot of damage, PLC automatic...Vehicle hydraulic pump station, often work environment is poor, the environment temperature difference is very big, the natureof the hydraulic oil is affected by temperature is very big, a lot of damage, PLC automatic control scheme and design of pumping station, the oiltemperature automatic control system realized the automation of the oil temperature control, greatly improving the pump station of the outdoorenvironment to adapt to the performance.展开更多
The increasing use of renewable energy in the power system results in strong stochastic disturbances and degrades the control performance of the distributed power grids.In this paper,a novel multi-agent collaborative ...The increasing use of renewable energy in the power system results in strong stochastic disturbances and degrades the control performance of the distributed power grids.In this paper,a novel multi-agent collaborative reinforcement learning algorithm is proposed with automatic optimization,namely,Dyna-DQL,to quickly achieve an optimal coordination solution for the multi-area distributed power grids.The proposed Dyna framework is combined with double Q-learning to collect and store the environmental samples.This can iteratively update the agents through buffer replay and real-time data.Thus the environmental data can be fully used to enhance the learning speed of the agents.This mitigates the negative impact of heavy stochastic disturbances caused by the integration of renewable energy on the control performance.Simulations are conducted on two different models to validate the effectiveness of the proposed algorithm.The results demonstrate that the proposed Dyna-DQL algorithm exhibits superior stability and robustness compared to other reinforcement learning algorithms.展开更多
An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS)...An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS) to mitigate the voltage fluctuations caused by environmental disturbances. Only AVC is used when small environ- mental disturbances happen, while BESC is incorporated with AVC to restrain the voltage fluctuations when large disturbances happen. An adjustable parameter determining the allowed amplitudes of voltage fluctuations is introduced to realize the above switching process. A benchmark low voltage distribution system including ]?VGS is established by using the commercial software Dig SILENT. Simulation results show that the voltage under AVCCS satisfies the IEEE Standard 1547, and the installed battery capacity is also reduced. Meanwhile, the battery's service life is ex- tended by avoiding frequent charges/discharges in the control process.展开更多
This paper presents the design and implementation of a digitally calibrated CMOS wideband radio frequency(RF) root-mean-square(RMS) power detector for high accuracy RF automatic gain control(AGC).The proposed RMS powe...This paper presents the design and implementation of a digitally calibrated CMOS wideband radio frequency(RF) root-mean-square(RMS) power detector for high accuracy RF automatic gain control(AGC).The proposed RMS power detector demonstrates accurate power detection in the presence of process,supply voltage, and temperature(PVT) variations by employing a digital calibration scheme.It also consumes low power and occupies a small chip area.The measurement results show that the scheme improves the accuracy of the detector to better than 0.3 dB over the PVT variations and wide operating frequency range from 0.2 to 0.8 GHz.Implemented in a 0.18μm CMOS process and occupying a small die area of 263×214μm^2,the proposed digitally calibrated CMOS RMS power detector only consumes 1.6 mA in power detection mode and 2.1 mA in digital calibration mode from a 1.8 V supply voltage.展开更多
Quickly getting back the synchronism of a disturbed interconnected multi-area power system due to variations in loading condition is recognized as prominent issue related to automatic generation control(AGC).In this r...Quickly getting back the synchronism of a disturbed interconnected multi-area power system due to variations in loading condition is recognized as prominent issue related to automatic generation control(AGC).In this regard,AGC system based on fuzzy logic,i.e.,so-called FLAGC can introduce an effectual performance to suppress the dynamic oscillations of tie-line power exchanges and frequency in multi-area interconnected power system.Apart from that,simultaneous coordination scheme based on particle swarm optimization(PSO)along with real coded genetic algorithm(RCGA)is suggested to coordinate FLAGCs of the all areas.To clarify the high efficiency of aforementioned strategy,two different interconnected multi-area power systems,i.e.,three-area hydro-thermal power system and five-area thermal power system have been taken into account for relevant studies.The potency of this strategy has been thoroughly dealt with by considering the step load perturbation(SLP)in both the under study power systems.To sum up,the simulation results have plainly revealed dynamic performance of FLAGC as compared with conventional AGC(CAGC)in each power system in order to damp out the power system oscillations.展开更多
This paper proposes a new structure to lower the power consumption of a variable gain amplifier(VGA) and keep the linearity of the VGA unchanged.The structure is used in a high rate amplitude-shift keying(ASK) bas...This paper proposes a new structure to lower the power consumption of a variable gain amplifier(VGA) and keep the linearity of the VGA unchanged.The structure is used in a high rate amplitude-shift keying(ASK) based IF-stage.It includes an automatic gain control(AGC) loop and ASK demodulator.The AGC mainly consists of sixstage VGAs.The IF-stage is realized in 0.18μm CMOS technology.The measurement results show that the power consumption of the whole system is very low.The system consumes 730μA while operating at 1.8 V.The minimum ASK signal the system could detect is 0.7 mV(peak to peak amplitude).展开更多
基金Project (No. 2006AA01Z226) supported by the Hi-Tech Researchand Development Program (863) of China
文摘An integrated laser diode driver(LDD) driving an edge-emitting laser diode was designed and fabricated by 0.35 μm BiCMOS technology. This paper proposes a scheme which combines the automatic power control loop and temperature com-pensation for modulation current in order to maintain constant extinction ratio and average optical power. To implement tem-perature compensation for modulation current,a novel circuit which generates a PTAT current by using the injecting base current of a bipolar transistor in saturation region,and alternates the amplifier feedback loop(closed or not) to control the state of the current path is presented. Simulation results showed that programmed by choice of external resistors,the IC can provide modu-lation current from 5 mA to 85 mA with temperature compensation adjustments and independent bias current from 4 mA to 100 mA. Optical test results showed that clear eye-diagrams can be obtained at 155 Mbps,with the output optical power being nearly constant,and the variation of extinction ratio being lower than 0.7 dB.
文摘It is need to establish site project department during the construction of electric power project.The head office should design and build the main structure,continually improve structure of project department,meantime,positively apply principle of automatic control to improve the site management of electric power construction.In this article,the application strategy of principle of automatic control is analyzed focusing on the site work of electric power construction.
文摘In order to optimize the allocation of power resources, ensure the safe and stable operation of the power system, maintain the coordinated development of the power grid and grid-connected power plants, and minimize line losses. The power dispatching institution shall issue the bus voltage curve to the grid-connected power plants on a quarterly basis, which shall be used as the basis for the assessment of reactive auxiliary services. In order to maintain the target voltage value issued by the power grid, the power plant adopts automatic voltage control device (AVC), and realizes the automation and intelligence of power plant voltage adjustment by adjusting and controlling the reactive power of the excitation system to respond to the target voltage value of the power grid system.
文摘This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.
文摘Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the topology, synchronization between nodes has become a critical issue which needs to be studied. The existing synchronization methods largely depend on the complex communication protocol. Therefore, this paper has proposed a method of automatic measurement and compensation of synchronization delay, and analyzed its operating principle and implementation procedure in detail. The results obtained from the experiments prove the proposed method to be correct, effective and practicable.
文摘The application frequency of electric power automation technology is higher and higher. When electric power enterprises carry out automation construction, according to the actual development status, they carry out the distribution of new energy, which can improve the development level of China's electric power industry. Vigorously carry out the power supply and distribution automation control work;provide more development strategies for the power supply and distribution industry, aiming to provide technical basis for the future development of the power industry;improve the service level of the industry, but also provide technical power for social development.
基金Project 104030 supported by the Ministry of Education of the People’s Republic of China
文摘Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal face and, on this basis, established an automatic control model of powered supports for the coal plough face. We introduced the working principle of the powered support control system of the plough at the mining face. We established three advanced characteristics of this control system: response speed, reliability and easy maintenance of the system. As well, we briefly introduced, the principal function of primary and subordinate controllers and the realization of the communication system by a Single Bus. Ten controllers were constructed and tested in our laboratorium. The results show that the control model is practical and meets actual conditions. It provides a theoretical basis for designing a comouter control system for a oowered support system of a plough at a mining face.
文摘Since wind power has the features of being intermittent and unpredictable, and usually needs transmission over long distances, grid integration of large-scale wind power will exert signif icant influence on power grid planning and construction, and will make a heavy impact on the safe and reliable operation of power systems. To deal with the diff iculties of large scale wind power dispatch, this paper presents a new automatic generation control (AGC) scheme that involves the participation of wind farms. The scheme is based on ultra-short-term wind power forecast. The author establishes a generation output distribution optimization mode for the power system with wind farms and verif ies the feasibility of the scheme by an example.
文摘Vehicle hydraulic pump station, often work environment is poor, the environment temperature difference is very big, the natureof the hydraulic oil is affected by temperature is very big, a lot of damage, PLC automatic control scheme and design of pumping station, the oiltemperature automatic control system realized the automation of the oil temperature control, greatly improving the pump station of the outdoorenvironment to adapt to the performance.
基金supported by the National Natural Sci-ence Foundation of China(No.52277108)Guangdong Provincial Department of Science and Technology(No.2022A0505020015).
文摘The increasing use of renewable energy in the power system results in strong stochastic disturbances and degrades the control performance of the distributed power grids.In this paper,a novel multi-agent collaborative reinforcement learning algorithm is proposed with automatic optimization,namely,Dyna-DQL,to quickly achieve an optimal coordination solution for the multi-area distributed power grids.The proposed Dyna framework is combined with double Q-learning to collect and store the environmental samples.This can iteratively update the agents through buffer replay and real-time data.Thus the environmental data can be fully used to enhance the learning speed of the agents.This mitigates the negative impact of heavy stochastic disturbances caused by the integration of renewable energy on the control performance.Simulations are conducted on two different models to validate the effectiveness of the proposed algorithm.The results demonstrate that the proposed Dyna-DQL algorithm exhibits superior stability and robustness compared to other reinforcement learning algorithms.
基金Supported by National Basic Research Program of China ("973" Program,No. 2009CB219701 and No. 2010CB234608)Tianjin Municipal Science and Technology Development Program (No. 09JCZDJC25000)Specialized Research Fund for Doctor Discipline of Ministry of Education of China (No. 20090032110064)
文摘An improved automatic voltage coordination control strategy (AVCCS) based on ;automatic voltage control (AVC) and battery energy storage control (BESC) is proposed for photovoltaic grid-connected system (PVGS) to mitigate the voltage fluctuations caused by environmental disturbances. Only AVC is used when small environ- mental disturbances happen, while BESC is incorporated with AVC to restrain the voltage fluctuations when large disturbances happen. An adjustable parameter determining the allowed amplitudes of voltage fluctuations is introduced to realize the above switching process. A benchmark low voltage distribution system including ]?VGS is established by using the commercial software Dig SILENT. Simulation results show that the voltage under AVCCS satisfies the IEEE Standard 1547, and the installed battery capacity is also reduced. Meanwhile, the battery's service life is ex- tended by avoiding frequent charges/discharges in the control process.
基金supported by the National High Technology Research and Development Program of China(No.2009AA011608)the Chinese National Major Science and Technology Projects Program(No.2009ZX01031-002-011-001)
文摘This paper presents the design and implementation of a digitally calibrated CMOS wideband radio frequency(RF) root-mean-square(RMS) power detector for high accuracy RF automatic gain control(AGC).The proposed RMS power detector demonstrates accurate power detection in the presence of process,supply voltage, and temperature(PVT) variations by employing a digital calibration scheme.It also consumes low power and occupies a small chip area.The measurement results show that the scheme improves the accuracy of the detector to better than 0.3 dB over the PVT variations and wide operating frequency range from 0.2 to 0.8 GHz.Implemented in a 0.18μm CMOS process and occupying a small die area of 263×214μm^2,the proposed digitally calibrated CMOS RMS power detector only consumes 1.6 mA in power detection mode and 2.1 mA in digital calibration mode from a 1.8 V supply voltage.
文摘Quickly getting back the synchronism of a disturbed interconnected multi-area power system due to variations in loading condition is recognized as prominent issue related to automatic generation control(AGC).In this regard,AGC system based on fuzzy logic,i.e.,so-called FLAGC can introduce an effectual performance to suppress the dynamic oscillations of tie-line power exchanges and frequency in multi-area interconnected power system.Apart from that,simultaneous coordination scheme based on particle swarm optimization(PSO)along with real coded genetic algorithm(RCGA)is suggested to coordinate FLAGCs of the all areas.To clarify the high efficiency of aforementioned strategy,two different interconnected multi-area power systems,i.e.,three-area hydro-thermal power system and five-area thermal power system have been taken into account for relevant studies.The potency of this strategy has been thoroughly dealt with by considering the step load perturbation(SLP)in both the under study power systems.To sum up,the simulation results have plainly revealed dynamic performance of FLAGC as compared with conventional AGC(CAGC)in each power system in order to damp out the power system oscillations.
基金supported by the National High-Tech Research and Development Program of China(Nos.2008AA010703,2009AA011606)the National Natural Science Foundation of China(No.60976023)
文摘This paper proposes a new structure to lower the power consumption of a variable gain amplifier(VGA) and keep the linearity of the VGA unchanged.The structure is used in a high rate amplitude-shift keying(ASK) based IF-stage.It includes an automatic gain control(AGC) loop and ASK demodulator.The AGC mainly consists of sixstage VGAs.The IF-stage is realized in 0.18μm CMOS technology.The measurement results show that the power consumption of the whole system is very low.The system consumes 730μA while operating at 1.8 V.The minimum ASK signal the system could detect is 0.7 mV(peak to peak amplitude).