Adsorption/desorption in a new Zn(Ⅱ)-TiO2 adsorption system was investigated at different particle concentrations (Cp). TEM, SEM and XRD analyses revealed that the TiO2 particles were an aggregation of nano-sized...Adsorption/desorption in a new Zn(Ⅱ)-TiO2 adsorption system was investigated at different particle concentrations (Cp). TEM, SEM and XRD analyses revealed that the TiO2 particles were an aggregation of nano-sized (approximately 10 nm) pure anatase-type TiO2. Adsorption experiments were carried out with particle concentrations of 100, 400 and 1000 mg/L, and their adsorption isotherms were found to decline successively, showing an obvious Cp effect. Desorption experiments indicated that adsorption in this system was irreversible, and the irreversibility increased with increasing Cp. These phenomena could be explained by the MEA (metastable equilibrium adsorption) theory and the Cp effect could be modeled well with an MEA-Freundlich-type Cp effect isotherm equation. This study may heln understand environmental behavior of contaminants on ultrafine natural particles.展开更多
In order to reveal the influence of forced ventilation on the dispersion of droplets ejected from roadheader-mounted external sprayer,the paper studies the air-flowing field and the droplet distribution under the cond...In order to reveal the influence of forced ventilation on the dispersion of droplets ejected from roadheader-mounted external sprayer,the paper studies the air-flowing field and the droplet distribution under the condition of gentle breeze and normal forced ventilation in heading face using the particle tracking technology of computational fluid dynamics(CFD).The results show that air-flowing tendency in the same section presents great comparability in the period of gentle breeze and forced ventilation,and the difference mainly embodies in the different wind velocity.The influence of ventilation on the dispersion of droplets is faint under the gentle breeze condition.The droplet can be evenly distributed around the cutting head.However,under the normal forced ventilation,a large number of droplets will drift to the return air side.At the same time,droplet clusters are predominantly presented in the lower part of windward side and the middle of the leeward side around the cutting head.In contrast,the droplet concentration in other parts around cutting head decreases a lot and the droplets are unable to form close-grained mist curtain.So the dust escape channel is formed.In addition,the simulation results also reveal that the disturbance of air flow on the droplet distribution can be effectively relieved when using ventilation duct with Coanda effect(VDCE).Field experiment results show that the dust suppression efficiency of total dust and respirable dust increases respectively by 10.5%and 9.3%when using VDCE,which proves that it can weaken the influence of airflow on droplet dispersion.展开更多
基金Project supported by the National Natural Science Foundation of China(No.20537020)the "Hundred Talent Scientist Program" of the Chinese Academy of Sciences.
文摘Adsorption/desorption in a new Zn(Ⅱ)-TiO2 adsorption system was investigated at different particle concentrations (Cp). TEM, SEM and XRD analyses revealed that the TiO2 particles were an aggregation of nano-sized (approximately 10 nm) pure anatase-type TiO2. Adsorption experiments were carried out with particle concentrations of 100, 400 and 1000 mg/L, and their adsorption isotherms were found to decline successively, showing an obvious Cp effect. Desorption experiments indicated that adsorption in this system was irreversible, and the irreversibility increased with increasing Cp. These phenomena could be explained by the MEA (metastable equilibrium adsorption) theory and the Cp effect could be modeled well with an MEA-Freundlich-type Cp effect isotherm equation. This study may heln understand environmental behavior of contaminants on ultrafine natural particles.
基金supported by the Program for Postgraduates Research Innovation in University of Jiangsu Province of China (No.CXLX13_955)the National Natural Science Foundation of China (No.51104153)
文摘In order to reveal the influence of forced ventilation on the dispersion of droplets ejected from roadheader-mounted external sprayer,the paper studies the air-flowing field and the droplet distribution under the condition of gentle breeze and normal forced ventilation in heading face using the particle tracking technology of computational fluid dynamics(CFD).The results show that air-flowing tendency in the same section presents great comparability in the period of gentle breeze and forced ventilation,and the difference mainly embodies in the different wind velocity.The influence of ventilation on the dispersion of droplets is faint under the gentle breeze condition.The droplet can be evenly distributed around the cutting head.However,under the normal forced ventilation,a large number of droplets will drift to the return air side.At the same time,droplet clusters are predominantly presented in the lower part of windward side and the middle of the leeward side around the cutting head.In contrast,the droplet concentration in other parts around cutting head decreases a lot and the droplets are unable to form close-grained mist curtain.So the dust escape channel is formed.In addition,the simulation results also reveal that the disturbance of air flow on the droplet distribution can be effectively relieved when using ventilation duct with Coanda effect(VDCE).Field experiment results show that the dust suppression efficiency of total dust and respirable dust increases respectively by 10.5%and 9.3%when using VDCE,which proves that it can weaken the influence of airflow on droplet dispersion.