Cu_(2)ZnSn(S,Se)_(4)(CZTSSe)is considered to be the most potential light-absorbing material to replace CuInGaSe_(2)(CIGS),but the actual photoelectric conversion efficiency of such cells is much lower than that of CIG...Cu_(2)ZnSn(S,Se)_(4)(CZTSSe)is considered to be the most potential light-absorbing material to replace CuInGaSe_(2)(CIGS),but the actual photoelectric conversion efficiency of such cells is much lower than that of CIGS.One of the reasons is the high recombination rate of carriers at the interface.In this paper,in order to reduce the carrier recombination,a new solar cell structure with double absorber layers of Al-doped ZnO(AZO)/intrinsic(i)-ZnO/CdS/CZTS_(x1)Se_(1−x1)(CZTSSe_(1))/CZTS_(x2)Se_(1−x2)(CZTSSe_(2))/Mo was proposed,and the optimal conduction band offsets(CBOs)of CdS/CZTSSe_(1) interface and CZTSSe_(1)/CZTSSe_(2) interface were determined by changing the S ratio in CZTSSe_(1) and CZTSSe_(2),and the effect of thickness of CZTSSe_(1) on the performance of the cell was studied.The efficiencies of the optimized single and double absorber layers reached 17.97%and 23.4%,respectively.Compared with the single absorber layer structure,the proposed structure with double absorber layers has better cell performance.展开更多
Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibratio...Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibration ratiometric fluorescent sensing platform has been designed for sensitive visual detection of levofloxacin(LEV)based on fluorescent europium metal-organic framework(Eu-MOF)probe.Specifically,the Eu-MOF was facilely synthesized via directly mixing Eu^(3+)with 1,10-phenanthroline-2,9-dicarboxylic acid(PDA)ligand at room temperature,which exhibited well-stable red fluorescence at 612 nm.Upon the addition of target LEV,the significant fluorescence quenching from Eu^(3+)was observed owing to the inner filter effect between the Eu-MOF and LEV.While the intrinsic fluorescence for LEV at 462nm was gradually enhanced,thereby realizing the self-calibration ratiometric fluorescence responses to LEV.Through this strategy,LEV can be detected down to 27 nmol/L.Furthermore,a test paper-based Eu-MOF integrated with the smartphone assisted RGB color analysis was exploited for the quantitative monitoring of LEV through the multi-color changes from red to blue,thus achieved portable,convenient and visual detection of LEV in honey and milk samples.Therefore,the developed strategy could provide a useful tool for supporting the practical on-site test in food samples.展开更多
AIM:To compare the visual and optical outcomes following femtosecond laser in situ keratomileusis(FS-LASIK)using an aberration neutral profile with asymmetric offset(AO)and pupil center(PC)treatments.METHODS:In this r...AIM:To compare the visual and optical outcomes following femtosecond laser in situ keratomileusis(FS-LASIK)using an aberration neutral profile with asymmetric offset(AO)and pupil center(PC)treatments.METHODS:In this randomized double-blind clinical trial study,48(24 cases)and 38 eyes(19 cases)underwent myopic astigmatism and hyperopic astigmatism LASIK.One eye of each individual was randomly assigned to AO centration and the fellow eye underwent the PC-centered method.The clinical outcomes including uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),safety and efficacy indexes,subjective spherical equivalent(SE)and corneal high-order aberrations(HOAs)were measured at baseline and 6mo postoperatively.RESULTS:In the myopic group,the mean preoperative SE and astigmatism were-4.12±0.87(-2.88 to-6.00)diopter(D)and-0.88±0.79(0 to-2.75)D,respectively.In the hyperopic group,the mean preoperative SE and astigmatism were 0.93±0.59(-0.25 to 2.25)D and-0.73±1.00(0 to-4.25)D,respectively.At 6mo postoperatively,the safety and efficacy indexes were similar for centration in myopic and hyperopic LASIK groups.In the myopic group,significant changes were found in horizontal trefoil(P=0.041)and oblique trefoil(P=0.031)in favor of AO centration treatment.CONCLUSION:Femtosecond-LASIK is a safe and efficacious procedure for treatment of myopic and hyperopic astigmatism.AO-centered and PC-centered approaches provide similar visual and refractive outcomes.Myopic astigmatism LASIK with AO centration leads to slightly better corneal aberration outcomes.展开更多
To efficiently search out the optimal cam contour,a software integrated optimization method considering cam mechanism’s kinematic and dynamic characteristics was presented,and its effectiveness was demonstrated by a ...To efficiently search out the optimal cam contour,a software integrated optimization method considering cam mechanism’s kinematic and dynamic characteristics was presented,and its effectiveness was demonstrated by a case study of the cam contour optimization for an offset press open-close gripper mechanism.The acceleration curve and the residual vibration model of the follower were separately studied.A symmetric harmonic trapezoidal curve was designed to control the follower’s acceleration,and single-DOF lumped parameter torsional vibration model was proposed to describe the follower’s residual vibration.Accordingly,corresponding motion curve design software and Simulink vibration model of the follower were developed respectively,and they were integrated into an automatic optimization platform with iSIGHT.The multi-objective optimization with objectives of minimizing both the acceleration and the residual vibration of the follower was completed within the platform by using NSGA-II algorithm.An appropriate point with lower acceleration and residual vibration was chosen from Pareto front as an optimal solution of the follower’s motion curve.Based on the follower’s new motion curve,the actual cam contour was generated by inverse kinematic simulation in COSMOSMotion.The offset press that installed our new designed cam exhibited a lower vibration than the previous machine,and the maximum measured acceleration of the offset press at a printing speed of 15000 r/h is reduced by 7.7%.展开更多
This work addresses the cut order planning(COP)problem for multi-color garment production,which is the first step in the clothing industry.First,a multi-objective optimization model of multicolor COP(MCOP)is establish...This work addresses the cut order planning(COP)problem for multi-color garment production,which is the first step in the clothing industry.First,a multi-objective optimization model of multicolor COP(MCOP)is established with production error and production cost as optimization objectives,combined with constraints such as the number of equipment and the number of layers.Second,a decoupled multi-objective optimization algorithm(DMOA)is proposed based on the linear programming decoupling strategy and non-dominated sorting in genetic algorithmsⅡ(NSGAII).The size-combination matrix and the fabric-layer matrix are decoupled to improve the accuracy of the algorithm.Meanwhile,an improved NSGAII algorithm is designed to obtain the optimal Pareto solution to the MCOP problem,thereby constructing a practical intelligent production optimization algorithm.Finally,the effectiveness and superiority of the proposed DMOA are verified through practical cases and comparative experiments,which can effectively optimize the production process for garment enterprises.展开更多
An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results ...An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results indicate: (1) a large region of low total pressure exists at the lower part of the inlet exit caused by the counter-rotating vortices in the S-shaped duct; (2) the performances of the inlet at Mach number 1.000 reach almost the highest, so the propulsion system could work efficiently in terms of aerodynamics; (3) the total pressure recovery increases slowly at first and then remains unvaried as the Mach number rises from 0.6 to 1.0, however, it does in an opposite manner in the conventional diverter-equipped S-shaped inlet; (4) the performances of the inlet are generally insensitive to angles of attack from -4° to 9.4° and yaw angles from 0° to 8° at Mach number 0.850, and angles of attack from -2° to 6° and yaw angles from 0° to 5° at Mach number 1.534.展开更多
Based on a physical understanding of nonlinearity and mismatch, a novel offset-cancellation technique for low voltage CMOS differential amplifiers is proposed. The technique transfers the offset voltage from the outpu...Based on a physical understanding of nonlinearity and mismatch, a novel offset-cancellation technique for low voltage CMOS differential amplifiers is proposed. The technique transfers the offset voltage from the output to other parts of the differential amplifier and can greatly reduce the input-referred offset voltage without extra power consumption. A 1.8V CMOS differential amplifier is implemented in 0.18μm CMOS process using the proposed technique. The simulation results show that the technique could reduce the input-referred offset voltage of the amplifier by 40% with a 20% load transistor mismatch and a 10% input differential transistor mismatch. Moreover, the proposed technique consumes the least power and achieves the highest integration among various offset-cancellation techniques.展开更多
The forward modeling procedure used in this article is formulated with the volume integral equation based on the tensor Green's function. The electromagnetic components responses are first calculated in the frequency...The forward modeling procedure used in this article is formulated with the volume integral equation based on the tensor Green's function. The electromagnetic components responses are first calculated in the frequency domain and then transformed to the time domain by digital filtering. The valley and hill topography with a layered earth is stimulated by a horizontal electric dipole (HED) transmitter, which is common in field surveys, and the TEM responses are calculated at the transmitter and receivers. The topography effects on the long offset electromagnetic transient (LOTEM) responses are discussed in detail. The results show that both valley and hill topography has significant effect on the LOTEM measurement. If the HED is located in the bottom of a valley, the distortion of the observed anomalous field at distance is severe. A valley at the receiver locations show a strong effect but are localized in space and time. In general, hill-shaped topography shows smaller effects no matter where its located. When the topography is located between source and receivers, the influence is negligible. We conclude that the location of the source is much more important than the receivers and it is critical to put the transmitter in an open flat area in the field survey.展开更多
The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appeara...The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appearance of harmonic peaks, the frequency difference δf between drive mode and sense mode must be less than 1/(2Qy). In order to eliminate the effects of the quadrature error and the offset error, as well as the inherent non- linearity in the capacitance-type sensors, a closed-loop feedback control circuit with quadrature correction is designed. The experimental results indicate that the quadrature error and offset error are corrected. By comparing with open-loop detection, the closed-loop feedback control circuit with quadrature correction decreases the non-linearity of the scale factor from 16. 02% to 0. 35 %, widens the maximum rate capability from ± 270 (°)/s to ± 370 (°)/s and increases the stability of zero bias from 155. 2 (°)/h to 60. 6 (°)/h.展开更多
基金supported by the Science and Technology Innovation Development Program(No.70304901).
文摘Cu_(2)ZnSn(S,Se)_(4)(CZTSSe)is considered to be the most potential light-absorbing material to replace CuInGaSe_(2)(CIGS),but the actual photoelectric conversion efficiency of such cells is much lower than that of CIGS.One of the reasons is the high recombination rate of carriers at the interface.In this paper,in order to reduce the carrier recombination,a new solar cell structure with double absorber layers of Al-doped ZnO(AZO)/intrinsic(i)-ZnO/CdS/CZTS_(x1)Se_(1−x1)(CZTSSe_(1))/CZTS_(x2)Se_(1−x2)(CZTSSe_(2))/Mo was proposed,and the optimal conduction band offsets(CBOs)of CdS/CZTSSe_(1) interface and CZTSSe_(1)/CZTSSe_(2) interface were determined by changing the S ratio in CZTSSe_(1) and CZTSSe_(2),and the effect of thickness of CZTSSe_(1) on the performance of the cell was studied.The efficiencies of the optimized single and double absorber layers reached 17.97%and 23.4%,respectively.Compared with the single absorber layer structure,the proposed structure with double absorber layers has better cell performance.
基金supported by the National Natural Science Foundation of China(Nos.32260247 and 22064010)the Natural Science Foundation of Jiangxi Province(Nos.20232BAB215071 and 20224BAB213009).
文摘Developing an accurate and visual sensing strategy for trace levels of fluoroquinolone residues that pose threat to food safety and human health is highly desired but remains challenging.Herein,a target selfcalibration ratiometric fluorescent sensing platform has been designed for sensitive visual detection of levofloxacin(LEV)based on fluorescent europium metal-organic framework(Eu-MOF)probe.Specifically,the Eu-MOF was facilely synthesized via directly mixing Eu^(3+)with 1,10-phenanthroline-2,9-dicarboxylic acid(PDA)ligand at room temperature,which exhibited well-stable red fluorescence at 612 nm.Upon the addition of target LEV,the significant fluorescence quenching from Eu^(3+)was observed owing to the inner filter effect between the Eu-MOF and LEV.While the intrinsic fluorescence for LEV at 462nm was gradually enhanced,thereby realizing the self-calibration ratiometric fluorescence responses to LEV.Through this strategy,LEV can be detected down to 27 nmol/L.Furthermore,a test paper-based Eu-MOF integrated with the smartphone assisted RGB color analysis was exploited for the quantitative monitoring of LEV through the multi-color changes from red to blue,thus achieved portable,convenient and visual detection of LEV in honey and milk samples.Therefore,the developed strategy could provide a useful tool for supporting the practical on-site test in food samples.
基金Supported by Noor Ophthalmology Research Center.
文摘AIM:To compare the visual and optical outcomes following femtosecond laser in situ keratomileusis(FS-LASIK)using an aberration neutral profile with asymmetric offset(AO)and pupil center(PC)treatments.METHODS:In this randomized double-blind clinical trial study,48(24 cases)and 38 eyes(19 cases)underwent myopic astigmatism and hyperopic astigmatism LASIK.One eye of each individual was randomly assigned to AO centration and the fellow eye underwent the PC-centered method.The clinical outcomes including uncorrected visual acuity(UCVA),best-corrected visual acuity(BCVA),safety and efficacy indexes,subjective spherical equivalent(SE)and corneal high-order aberrations(HOAs)were measured at baseline and 6mo postoperatively.RESULTS:In the myopic group,the mean preoperative SE and astigmatism were-4.12±0.87(-2.88 to-6.00)diopter(D)and-0.88±0.79(0 to-2.75)D,respectively.In the hyperopic group,the mean preoperative SE and astigmatism were 0.93±0.59(-0.25 to 2.25)D and-0.73±1.00(0 to-4.25)D,respectively.At 6mo postoperatively,the safety and efficacy indexes were similar for centration in myopic and hyperopic LASIK groups.In the myopic group,significant changes were found in horizontal trefoil(P=0.041)and oblique trefoil(P=0.031)in favor of AO centration treatment.CONCLUSION:Femtosecond-LASIK is a safe and efficacious procedure for treatment of myopic and hyperopic astigmatism.AO-centered and PC-centered approaches provide similar visual and refractive outcomes.Myopic astigmatism LASIK with AO centration leads to slightly better corneal aberration outcomes.
基金the Foshan Science and Technology Innovation Team Project(No.FS0AA-KJ919-4402-0060)the National Natural Science Foundation of China(No.62263018)。
文摘To efficiently search out the optimal cam contour,a software integrated optimization method considering cam mechanism’s kinematic and dynamic characteristics was presented,and its effectiveness was demonstrated by a case study of the cam contour optimization for an offset press open-close gripper mechanism.The acceleration curve and the residual vibration model of the follower were separately studied.A symmetric harmonic trapezoidal curve was designed to control the follower’s acceleration,and single-DOF lumped parameter torsional vibration model was proposed to describe the follower’s residual vibration.Accordingly,corresponding motion curve design software and Simulink vibration model of the follower were developed respectively,and they were integrated into an automatic optimization platform with iSIGHT.The multi-objective optimization with objectives of minimizing both the acceleration and the residual vibration of the follower was completed within the platform by using NSGA-II algorithm.An appropriate point with lower acceleration and residual vibration was chosen from Pareto front as an optimal solution of the follower’s motion curve.Based on the follower’s new motion curve,the actual cam contour was generated by inverse kinematic simulation in COSMOSMotion.The offset press that installed our new designed cam exhibited a lower vibration than the previous machine,and the maximum measured acceleration of the offset press at a printing speed of 15000 r/h is reduced by 7.7%.
基金Supported by the Natural Science Foundation of Zhejiang Province(No.LQ22F030015).
文摘This work addresses the cut order planning(COP)problem for multi-color garment production,which is the first step in the clothing industry.First,a multi-objective optimization model of multicolor COP(MCOP)is established with production error and production cost as optimization objectives,combined with constraints such as the number of equipment and the number of layers.Second,a decoupled multi-objective optimization algorithm(DMOA)is proposed based on the linear programming decoupling strategy and non-dominated sorting in genetic algorithmsⅡ(NSGAII).The size-combination matrix and the fabric-layer matrix are decoupled to improve the accuracy of the algorithm.Meanwhile,an improved NSGAII algorithm is designed to obtain the optimal Pareto solution to the MCOP problem,thereby constructing a practical intelligent production optimization algorithm.Finally,the effectiveness and superiority of the proposed DMOA are verified through practical cases and comparative experiments,which can effectively optimize the production process for garment enterprises.
基金National Basic Research Program of China (5130802)
文摘An investigation on the ventral diverterless high offset S-shaped inlet is carried out at Mach numbers from 0.600 to 1.534, angles of attack from -4° to 9.4°, and yaw angles from 0° to 8°. Results indicate: (1) a large region of low total pressure exists at the lower part of the inlet exit caused by the counter-rotating vortices in the S-shaped duct; (2) the performances of the inlet at Mach number 1.000 reach almost the highest, so the propulsion system could work efficiently in terms of aerodynamics; (3) the total pressure recovery increases slowly at first and then remains unvaried as the Mach number rises from 0.6 to 1.0, however, it does in an opposite manner in the conventional diverter-equipped S-shaped inlet; (4) the performances of the inlet are generally insensitive to angles of attack from -4° to 9.4° and yaw angles from 0° to 8° at Mach number 0.850, and angles of attack from -2° to 6° and yaw angles from 0° to 5° at Mach number 1.534.
文摘Based on a physical understanding of nonlinearity and mismatch, a novel offset-cancellation technique for low voltage CMOS differential amplifiers is proposed. The technique transfers the offset voltage from the output to other parts of the differential amplifier and can greatly reduce the input-referred offset voltage without extra power consumption. A 1.8V CMOS differential amplifier is implemented in 0.18μm CMOS process using the proposed technique. The simulation results show that the technique could reduce the input-referred offset voltage of the amplifier by 40% with a 20% load transistor mismatch and a 10% input differential transistor mismatch. Moreover, the proposed technique consumes the least power and achieves the highest integration among various offset-cancellation techniques.
基金supported by National Natural Science Foundation of China (Nos. 40727001, 40774073, and 40774074)the National Basic Research Programs of China (973 Program) (No. 2007CB209607)the Doctoral Program of Higher Research and Special funds (No. 20070489001)
文摘The forward modeling procedure used in this article is formulated with the volume integral equation based on the tensor Green's function. The electromagnetic components responses are first calculated in the frequency domain and then transformed to the time domain by digital filtering. The valley and hill topography with a layered earth is stimulated by a horizontal electric dipole (HED) transmitter, which is common in field surveys, and the TEM responses are calculated at the transmitter and receivers. The topography effects on the long offset electromagnetic transient (LOTEM) responses are discussed in detail. The results show that both valley and hill topography has significant effect on the LOTEM measurement. If the HED is located in the bottom of a valley, the distortion of the observed anomalous field at distance is severe. A valley at the receiver locations show a strong effect but are localized in space and time. In general, hill-shaped topography shows smaller effects no matter where its located. When the topography is located between source and receivers, the influence is negligible. We conclude that the location of the source is much more important than the receivers and it is critical to put the transmitter in an open flat area in the field survey.
文摘The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appearance of harmonic peaks, the frequency difference δf between drive mode and sense mode must be less than 1/(2Qy). In order to eliminate the effects of the quadrature error and the offset error, as well as the inherent non- linearity in the capacitance-type sensors, a closed-loop feedback control circuit with quadrature correction is designed. The experimental results indicate that the quadrature error and offset error are corrected. By comparing with open-loop detection, the closed-loop feedback control circuit with quadrature correction decreases the non-linearity of the scale factor from 16. 02% to 0. 35 %, widens the maximum rate capability from ± 270 (°)/s to ± 370 (°)/s and increases the stability of zero bias from 155. 2 (°)/h to 60. 6 (°)/h.