A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample ...A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.展开更多
Absorption and refraction of the inner transition F2 ←→F3 of the closed four level N-type atom have been investigated under a weak field. The outer transitions F1←→F3 and F2←→F4 are resonantly interacted with dr...Absorption and refraction of the inner transition F2 ←→F3 of the closed four level N-type atom have been investigated under a weak field. The outer transitions F1←→F3 and F2←→F4 are resonantly interacted with drive field with frequency ωc and Rabi frequency Ωc, and saturation field with ωs and Ωs, respectively. For the suitable Rabi frequencies Ωc and Ωs, we obtain the Mellow absorption spectrum of probe field. The reason is that the drive field excites the atom to the upper level F3 and simultaneously the saturation field takes the atom out of the lower level F2, leading to the stimulated emission. Meanwhile, due to the dynamic energy splitting induced by the drive and saturation fields, the two- and four-peaked absorption spectra are observed. At the zero off-resonance detuning of probe field, we also find the transfer of dispersion from negative to positive with an increment of Ωs. Finally, the refractive index enhancement is predicted for a wide spectral region.展开更多
Accurate estimation of the peak seismic responses of structures is important in earthquake resistant design. The internal force distributions and the seismic responses of structures are quite complex, since ground mot...Accurate estimation of the peak seismic responses of structures is important in earthquake resistant design. The internal force distributions and the seismic responses of structures are quite complex, since ground motions are multidirectional. One key issue is the uncertainty of the incident angle between the directions of ground motion and the reference axes of the structure. Different assumed seismic incidences can result in different peak values within the scope of design spectrum analysis for a given structure and earthquake ground motion record combination. Using time history analysis to determine the maximum structural responses excited by a given earthquake record requires repetitive calculations to determine the critical incident angle. This paper presents a transformation approach for relatively accurate and rapid determination of the maximum peak responses of a linear structure subjected to three-dimensional excitations within all possible seismic incident angles. The responses can be deformations, internal forces, strains and so on. An irregular building structure model is established using SAP2000 program. Several typical earthquake records and an artificial white noise are applied to the structure model to illustrate the variation of the maximum structural responses for different incident angles. Numerical results show that for many structural parameters, the variation can be greater than 100%. This method can be directly applied to time history analysis of structures using existing computer software to determine the peak responses without carrying out the analyses for all possible incident angles. It can also be used to verify and/or modify aseismic designs by using response spectrum analysis.展开更多
Contactless measurement of wind flow has been utilized in many fields, such as weather forecasting, hurricane tracking, and aeronautic alarm. In this paper, a novel multi-laser beams measuring system (MLBM) for high...Contactless measurement of wind flow has been utilized in many fields, such as weather forecasting, hurricane tracking, and aeronautic alarm. In this paper, a novel multi-laser beams measuring system (MLBM) for high precision detection of wind field based on optical scintillations and small perturbation theory was proposed and verified. According to the fluctuation intensity of laser backscatter received by two detectors, peak delay technique was adopted to determine the velocity of wind flow. Detailed procedure to deal with backscatter signals was also presented. Then, practical experiments and measurement results showed high precision of the proposed system for wind measurement with a relative error as 3.21%. Consequently, the MLBM system possesses obvious potential application in engineering project.展开更多
针对燃煤机组锅炉主再热汽温控制中存在的滞后性、多变量耦合及动态工况适应难题,文章提出一种融合数字孪生技术与最小二乘支持向量机(Least Squares Support Vector Machine,LS-SVM)的汽温寻优方法。通过构建锅炉三维数字孪生模型实现...针对燃煤机组锅炉主再热汽温控制中存在的滞后性、多变量耦合及动态工况适应难题,文章提出一种融合数字孪生技术与最小二乘支持向量机(Least Squares Support Vector Machine,LS-SVM)的汽温寻优方法。通过构建锅炉三维数字孪生模型实现设备状态实时映射,结合LS-SVM建立多变量动态预测模型,并引入多目标微分进化算法(MODE)进行参数优化。实际应用表明,该方法使主汽温波动范围从±7℃缩小至±2.5℃,再热汽温预测误差稳定在±1.5℃以内,年节约燃煤成本超400万元,为火电机组深度调峰与能效提升提供技术支撑。展开更多
The mechanical behavior and microstructures of an Al-Zn-Mg-Cu-Cr aluminum alloy during multi-stage hot deformation were investigated by thermal stimulation test, optical microscopy, and transmission electron microscop...The mechanical behavior and microstructures of an Al-Zn-Mg-Cu-Cr aluminum alloy during multi-stage hot deformation were investigated by thermal stimulation test, optical microscopy, and transmission electron microscopy. The true stress vs true strain curves and the microstructure evolution of two hot deformation procedures were gained. The flow stress of the alloy studied decreases with increasing the deforming passes and declining the temperature, and the larger the temperature decline between adjacent stages, the larger the peak stress fall is. The stress-strain behavior mainly result from the dynamic recovery during deformation, the static recovery and recrystallization in the delay time, and the second phases precipitated from the matrix at high temperature.展开更多
The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resista...The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).展开更多
文摘A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 10334010 10304001, 10521002, 10434020, 10328407 and 90501007). We are grateful to Professor Zhang J X for her helpful discussions.
文摘Absorption and refraction of the inner transition F2 ←→F3 of the closed four level N-type atom have been investigated under a weak field. The outer transitions F1←→F3 and F2←→F4 are resonantly interacted with drive field with frequency ωc and Rabi frequency Ωc, and saturation field with ωs and Ωs, respectively. For the suitable Rabi frequencies Ωc and Ωs, we obtain the Mellow absorption spectrum of probe field. The reason is that the drive field excites the atom to the upper level F3 and simultaneously the saturation field takes the atom out of the lower level F2, leading to the stimulated emission. Meanwhile, due to the dynamic energy splitting induced by the drive and saturation fields, the two- and four-peaked absorption spectra are observed. At the zero off-resonance detuning of probe field, we also find the transfer of dispersion from negative to positive with an increment of Ωs. Finally, the refractive index enhancement is predicted for a wide spectral region.
基金Supported by: U.S. Federal Highway Administration Under Grant No. DTFH61-98-C-00094 U.S. National Science Foundation Under Grant No. CMS-9701471
文摘Accurate estimation of the peak seismic responses of structures is important in earthquake resistant design. The internal force distributions and the seismic responses of structures are quite complex, since ground motions are multidirectional. One key issue is the uncertainty of the incident angle between the directions of ground motion and the reference axes of the structure. Different assumed seismic incidences can result in different peak values within the scope of design spectrum analysis for a given structure and earthquake ground motion record combination. Using time history analysis to determine the maximum structural responses excited by a given earthquake record requires repetitive calculations to determine the critical incident angle. This paper presents a transformation approach for relatively accurate and rapid determination of the maximum peak responses of a linear structure subjected to three-dimensional excitations within all possible seismic incident angles. The responses can be deformations, internal forces, strains and so on. An irregular building structure model is established using SAP2000 program. Several typical earthquake records and an artificial white noise are applied to the structure model to illustrate the variation of the maximum structural responses for different incident angles. Numerical results show that for many structural parameters, the variation can be greater than 100%. This method can be directly applied to time history analysis of structures using existing computer software to determine the peak responses without carrying out the analyses for all possible incident angles. It can also be used to verify and/or modify aseismic designs by using response spectrum analysis.
基金supported by National Science Foundation of China (NSFC) under Grant No.60425101-1Foundation for Innovative Research Groups of NSFC under Grant No.60721001
文摘Contactless measurement of wind flow has been utilized in many fields, such as weather forecasting, hurricane tracking, and aeronautic alarm. In this paper, a novel multi-laser beams measuring system (MLBM) for high precision detection of wind field based on optical scintillations and small perturbation theory was proposed and verified. According to the fluctuation intensity of laser backscatter received by two detectors, peak delay technique was adopted to determine the velocity of wind flow. Detailed procedure to deal with backscatter signals was also presented. Then, practical experiments and measurement results showed high precision of the proposed system for wind measurement with a relative error as 3.21%. Consequently, the MLBM system possesses obvious potential application in engineering project.
文摘针对燃煤机组锅炉主再热汽温控制中存在的滞后性、多变量耦合及动态工况适应难题,文章提出一种融合数字孪生技术与最小二乘支持向量机(Least Squares Support Vector Machine,LS-SVM)的汽温寻优方法。通过构建锅炉三维数字孪生模型实现设备状态实时映射,结合LS-SVM建立多变量动态预测模型,并引入多目标微分进化算法(MODE)进行参数优化。实际应用表明,该方法使主汽温波动范围从±7℃缩小至±2.5℃,再热汽温预测误差稳定在±1.5℃以内,年节约燃煤成本超400万元,为火电机组深度调峰与能效提升提供技术支撑。
基金supported by the National Key Basic Research and Development Program of China(No.G1999064908)
文摘The mechanical behavior and microstructures of an Al-Zn-Mg-Cu-Cr aluminum alloy during multi-stage hot deformation were investigated by thermal stimulation test, optical microscopy, and transmission electron microscopy. The true stress vs true strain curves and the microstructure evolution of two hot deformation procedures were gained. The flow stress of the alloy studied decreases with increasing the deforming passes and declining the temperature, and the larger the temperature decline between adjacent stages, the larger the peak stress fall is. The stress-strain behavior mainly result from the dynamic recovery during deformation, the static recovery and recrystallization in the delay time, and the second phases precipitated from the matrix at high temperature.
文摘The multi-radiation of X-rays was investigated with special attention to their energy spectrum in a Mather-type plasma focus device (operated with argon gas). The analysis is based on the effect of anomalous resistances. To study the energy spectrum, a four-channel diode X-ray spectrometer was used along with a special set of filters. The filters were suitable for detection of medium range X-rays as well as hard X-rays with energy exceeding 30 keV. The results indicate that the anomalous resistivity effect during the post pinch phase may cause multi-radiation of X-rays with a total duration of 300 ± 50 ns. The significant contribution of Cu-Kα was due to the medium range X-rays, nonetheless, hard X-rays with energies greater than 15 keV also participate in the process. The total emitted X-ray energy in the forms of Cu-K and Cu-K/3 was around 0.14 ± 0.02 (J/Sr) and 0.04 ±0.01 (J/Sr), respectively. The total energy of the emitted hard X-ray (〉 15 keV) was around 0.12± 0.02 (J/Sr).