期刊文献+
共找到748篇文章
< 1 2 38 >
每页显示 20 50 100
Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion 被引量:7
1
作者 Davide Ippolito Silvia Girolama Drago +2 位作者 Cammillo Talei Franzesi Davide Fior Sandro Sironi 《World Journal of Gastroenterology》 SCIE CAS 2016年第20期4891-4900,共10页
AIM: To assess the diagnostic accuracy of multidetectorrow computed tomography(MDCT) as compared with conventional magnetic resonance imaging(MRI), in identifying mesorectal fascia(MRF) invasion in rectal cancer patie... AIM: To assess the diagnostic accuracy of multidetectorrow computed tomography(MDCT) as compared with conventional magnetic resonance imaging(MRI), in identifying mesorectal fascia(MRF) invasion in rectal cancer patients.METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner(ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 m As. Imaging data were reviewed as axial and as multiplanar reconstructions(MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images(DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed.RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91(41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged(45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value(PPV) 80.4%, negative predictive value(NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant(P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. 展开更多
关键词 Magnetic resonance multi detector computed tomography Rectal cancer Mesorectal fascia multiplanar reconstructions
暂未订购
Multi-detector CT features of acute intestinal ischemia and their prognostic correlations 被引量:10
2
作者 Marco Moschetta Michele Telegrafo +2 位作者 Leonarda Rella Amato Antonio Stabile Ianora Giuseppe Angelelli 《World Journal of Radiology》 CAS 2014年第5期130-138,共9页
Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rate... Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multidetector computed tomography(MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic informationthanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software. 展开更多
关键词 multi-detector COMPUTED tomography BOWEL ISCHEMIA MESENTERIC INFARCTION
暂未订购
Current status of low dose multi-detector CT in the urinary tract 被引量:4
3
作者 Mi Kim Sung Sarabjeet Singh Mannudeep K Kalra 《World Journal of Radiology》 CAS 2011年第11期256-265,共10页
Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems ca... Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems can be illustrated more precisely with the advent of multi-detector row CT through thinner slices,high speed acquisitions,and enhanced longitudinal spatial resolution resulting in improved reformatted coronal images.On the other hand,a significant increase in exposure to ionizing radiation,especially in the radiosensitive organs,such as the gonads,is a concern with the increased utilization of urinary tract CT.In this article,we discuss the strategies and techniques availablefor reducing radiation dose for a variety of urinary tractCT protocols with metabolic clinical examples.We also reviewed CT for hematuria evaluation and related scan parameter optimization such as,reducing the number of acquisition phases,CT angiography of renal donors and lowering tube potential,when possible. 展开更多
关键词 HEMATURIA evaluation Low dose COMPUTEDTOMOGRAPHY multi-detector row COMPUTED TOMOGRAPHY Renal donor COMPUTED TOMOGRAPHY angiography Urinary TRACT imaging
暂未订购
Diagnosis of Congenital Aortic Arch Anomalies in Chinese Children by Multi-Detector Computed Tomography Angiography 被引量:2
4
作者 陈鑫 屈艳娟 +2 位作者 彭志远 鲁锦国 马小静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第3期447-451,共5页
Summary: The purpose of this study was to evaluate the value of multi-detector computed tomography (MDCT) angiography for the diagnosis of congenital aortic arch anomalies and present the radiological images of con... Summary: The purpose of this study was to evaluate the value of multi-detector computed tomography (MDCT) angiography for the diagnosis of congenital aortic arch anomalies and present the radiological images of congenital aortic arch anomalies in Chinese children. MDCT angiography and transthoracic echocardiography (TTE) were applied for the diagnosis of congenital aortic arch anomalies in 362 Chi- nese children between May 2006 and December 2011 (age ranges from 5 days to 12 years; mean age, 3.3 years). Surgery and/or catheter angiography (CA) were conducted in all patients to confirm the final diagnosis. In the 362 Chinese children with congenital heart anomalies, congenital aortic arch anomalies were definitely diagnosed in 198 children and 164 children ruled out by operation and/or (CA). Among the 198 children with anomalies, coarctation of aorta (CoA), interruption of aortic arch (IAA), fight aor- tic arch, aberrant right subclavian artery and double aortic arch were diagnosed in 134, 32, 20, 10 and 2 children respectively, and there were 6 cases with uncommon congenital aortic arch anomalies: 2 had double aortic arch including 1 with five branches of the aortic arch, 2 had isolation of the right sub- clavian artery with two patent ductus arteriosus (PDA), 1 had an isolation of the common carotid artery with a PDA, and 1 had double PDA with a single ventricle and pulmonary artery atresia. Among the 32 children with IAA, 28 were of type A, and 4 were of type B. The diagnostic sensitivity, specificity and accuracy of MDCT angiography for congenital aortic arch anomaiies were 100% (198/198), 98% (161/164) and 99% (359/362), respectively. The diagnostic sensitivity, specificity and accuracy of TTE were 92% (182/198), 81% (133/164) and 87% (315/362), respectively. In conclusion, MDCT angiogra- phy is a reliable, noninvasive imaging technique for the diagnosis of congenital aortic arch anomalies in children. Sometimes, even more information can be obtained from this technique than from conven- tional angiography. 展开更多
关键词 congenital anomalies multi-detector computed tomography angiography aortic arch
暂未订购
Multi-detector computed tomography imaging of large airway pathology:A pictorial review 被引量:1
5
作者 Tejeshwar Singh Jugpal Anju Garg +2 位作者 Gulshan Rai Sethi Mradul Kumar Daga Jyoti Kumar 《World Journal of Radiology》 CAS 2015年第12期459-474,共16页
The tracheobronchial tree is a musculo-cartilagenous framework which acts as a conduit to aerate the lungs and consequently the entire body. A large spectrum of pathological conditions can involve the trachea and bron... The tracheobronchial tree is a musculo-cartilagenous framework which acts as a conduit to aerate the lungs and consequently the entire body. A large spectrum of pathological conditions can involve the trachea and bronchial airways. These may be congenital anomalies, infections, post-intubation airway injuries, foreign body aspiration or neoplasms involving the airway. Appropriate management of airway disease requires an early and accurate diagnosis. In this pictorial essay review, we will comprehensively describe the various airway pathologies and their imaging findings by multi-detector computed tomography. 展开更多
关键词 multi detector computed tomography TRACHEA BRONCHIAL tree AIRWAY ABNORMALITY virtual BRONCHOSCOPY
暂未订购
Contrast enhanced multi-detector CT and MR findings of a well-differentiated pancreatic vipoma 被引量:1
6
作者 Luigi Camera Rosa Severino +5 位作者 Antongiulio Faggiano Stefania Masone Gelsomina Mansueto Simone Maurea Rosa Fonti Marco Salvatore 《World Journal of Radiology》 CAS 2014年第10期840-845,共6页
Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not speci... Pancreatic vipoma is an extremely rare tumor accounting for less than 2% of endocrine pancreatic neoplasms with a reported incidence of 0.1-0.6 per million. While cross-sectional imaging findings are usually not specific, exact localization of the tumor by means of either computed tomography(CT) or magnetic resonance(MR) is pivotal for surgical planning. However, cross-sectional imaging findings are usually not specific and further characterization of the tumor may only be achieved bysomatostatin-receptor scintigraphy(SRS). We report the case of a 70 years old female with a two years history of watery diarrhoea who was found to have a solid, inhomogeneously enhancing lesion at the level of the pancreatic tail at Gadolinium-enhanced MR(Somatom Trio 3T, Siemens, Germany). The tumor had been prospectively overlooked at a contrast-enhanced multi-detector CT(Aquilion 64, Toshiba, Japan) performed after i.v. bolus injection of only 100 cc of iodinated non ionic contrast media because of a chronic renal failure(3.4 mg/mL) but it was subsequently confirmed by SRS. The patient first underwent a successful symptomatic treatment with somatostatin analogues and was then submitted to a distal pancreasectomy with splenectomy to remove a capsulated whitish tumor which turned out to be a well-differentiated vipoma at histological and immuno-histochemical analysis. 展开更多
关键词 PANCREATIC endocrine tumor Vasoactive intestinal peptide multi-detector computed tomography CONTRAST induced nephropathy Magnetic resonance imaging Nephrogenic systemic fibrosis SOMATOSTATIN receptor SCINTIGRAPHY
暂未订购
Relation between Epicardial Adipose Tissue Thickness Assessed by Multidetector Computed Tomography and Significance of Coronary Artery Disease 被引量:1
7
作者 Neveen I. Samy Mohammad Fakhry Walaa Farid 《World Journal of Cardiovascular Diseases》 2020年第2期91-101,共11页
Objective: To evaluate the relation between epicardial adipose tissue (EAT) thickness and also pericoronary fat assessed by Multidetector Computed Tomography (MDCT) with both calcium score and significance of coronary... Objective: To evaluate the relation between epicardial adipose tissue (EAT) thickness and also pericoronary fat assessed by Multidetector Computed Tomography (MDCT) with both calcium score and significance of coronary artery disease. Background: Epicardial adipose tissue (the visceral fat of the heart present under the visceral layer of the pericardium) has the same origin of abdominal visceral fat, which is known to be strongly related to the development of coronary artery atherosclerosis. Multidetector CT (MDCT) provides an accurate and reproducible quantification of EAT due to its high spatial and temporal resolution. Patients and Methods: The current study included 70 patients with low-intermediate probability of coronary artery disease. All patients were subjected to 256 Multidetectors CT to assess EAT thickness, the mean thickness of the pericoronary fat surrounding the three coronary arteries and coronary calcium score. Also coronary CT angiography was done and patients were then divided into 3 groups according to significance of coronary atherosclerosis: Group 1: No atherosclerosis (20 patients), Group 2: Non obstructive atherosclerosis (luminal narrowing less than 50% in diameter) (25 patients), Group3: Obstructive atherosclerosis (luminal narrowing ≥ 50%) (25 patients). Results: The mean EAT thickness and the mean pericoronary fat thickness were significantly higher in patients with obstructive coronary artery disease (CAD) with stenosis > 50% (group 3) compared to other groups with normal coronaries or non obstructive (CAD). ROC curve was used to define the best cut off value of the thickness of both EAT and pericoronary fat in predicting the obstructive CAD group which was ≥7.2 and 12.6 mm for epicardial and pericoronary fat respectively. Also there is a positive correlation between both epicardial adipose tissue and pericoronary fat thickness and the coronary calcium score. Conclusion: EAT thickness and pericoronary fat thickness can be used in predicting the significance of coronary artery disease. 展开更多
关键词 CORONARY Artery Disease multi detector COMPUTED Tomography CORONARY CT ANGIOGRAPHY EPICARDIAL ADIPOSE Tissue Thickness Pericoronary Fat Thickness
暂未订购
Soller slits automatic focusing method for multi-element fluorescence detector 被引量:1
8
作者 Ya-Yun Yang Qian Gao +3 位作者 Song-Qi Gu Hai-Sheng Yu Rui-You Lu Yu-Ying Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第5期179-187,共9页
In X-ray absorption fine structure(XAFS) experiments,Soller slits are widely used as filter devices in order to improve the signal to noise ratio.Performing high accuracy manual focusing operations is a time-consuming... In X-ray absorption fine structure(XAFS) experiments,Soller slits are widely used as filter devices in order to improve the signal to noise ratio.Performing high accuracy manual focusing operations is a time-consuming process;therefore,this work introduces an automatic focusing method for Soller slits in multi-element fluorescence detectors.This method establishes a relation model between the fluorescence intensity distribution and the coordinates of the fluorescence excitation point.According to this relation model,the actual coordinates of the fluorescence excitation point can be deduced from the detected fluorescence intensity distribution and used in focusing operations.This method has proven to be feasible in an XAFS experiment at the BL14W1 beamline of the Shanghai Synchrotron Radiation Facility. 展开更多
关键词 荧光检测器 聚焦方法 狭缝 X射线吸收精细结构 XAFS实验 关系模型 光强度分布 高信噪比
在线阅读 下载PDF
A spontaneous strangulated transomental hernia: Prospective and retrospective multi-detector computed tomography findings
9
作者 Luigi Camera Angela De Gennaro +5 位作者 Margaret Longobardi Stefania Masone Emanuela Calabrese Walter Del Vecchio Giovanni Persico Marco Salvatore 《World Journal of Radiology》 CAS 2014年第2期26-30,共5页
Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-tr... Transomental hernias are among the rarest type of all internal hernias which overall account for less than 6% of small bowel obstructions. Most transomental hernias occurring in adults are either iatrogenic or post-traumatic. More rarely, a spontaneous herniation of small bowel loops may result from senile atrophy of the omentum. We report a case of an 86-year-old male who presented with signs and symptoms of small bowel obstruction but had no past surgical or traumatic abdominal history. At contrast-enhanced multi-detector row computed tomography(CT), a cluster of fluid-filled dilated small bowel loops could be appreciated in the left flank, with associated signs of bowel wall ischemia. Swirling of the mesenteric vessels could also be appreciated and CT findings were prospectively considered consistent with a strangulated small bowel volvulus. At laparotomy, no derotation had to be performed but up to 100 cm of gangrenous small bowel loops had to be resected because of a transomental hernia through a small defect in the left part of the greater omentum. Retrospective reading of CT images was performed and findings suggestive of transomental herniation could then be appreciated. 展开更多
关键词 Small BOWEL OBSTRUCTION Internal HERNIAS Transomental HERNIA multi-detector row computed tomography STRANGULATION
暂未订购
Multidetector computed tomography of temporomandibular joint: A road less travelled
10
作者 Shivani Pahwa Ashu Seith Bhalla +1 位作者 Ajoy Roychaudhary Ongkila Bhutia 《World Journal of Clinical Cases》 SCIE 2015年第5期442-449,共8页
This article reviews the imaging anatomy of temporomandibular joint(TMJ), describes the technique of multi-detector computed tomography(MDCT) of the TMJ, and describes in detail various osseous pathologic afflictions ... This article reviews the imaging anatomy of temporomandibular joint(TMJ), describes the technique of multi-detector computed tomography(MDCT) of the TMJ, and describes in detail various osseous pathologic afflictions affecting the joint. Traumatic injuries affecting the mandibular condyle are most common, followed by joint ankylosis as a sequel to arthritis. The congenital anomalies are less frequent, hemifacial microsomia being the most commonly encountered anomaly involving the TMJ. Neoplastic afflictions of TMJ are distinctly uncommon, osteochondroma being one of the most common lesions. MDCT enables comprehensive evaluation of osseous afflictions of TMJ, and is a valuable tool for surgical planning. Sagittal, coronal and 3D reformatted images well depict osseous TMJ lesions, and their relationship to adjacent structures. 展开更多
关键词 TEMPOROMANDIBULAR JOINT TEMPOROMANDIBULAR JOINT TRAUMA CONGENITAL anomalies of TEMPOROMANDIBULAR JOINT TEMPOROMANDIBULAR JOINT ARTHRITIS multi-detector computed tomography
暂未订购
Multi-Detector Row Computed Tomography Urography (MDCTU) in the Evaluation of Microscopic Hematuria in Adults
11
作者 Mohamed A. Mahmoud Mustafa Z. Mahmoud +3 位作者 Mohammed A. Ali Omer Mohamed E. M. Garalnabi Ahmed Abukonna Maram A. Fagiri 《Open Journal of Radiology》 2015年第1期20-27,共8页
Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, o... Multi-detector row computed tomography urography (MDCTU) becomes the imaging modality of choice for evaluation of the kidneys and urinary tract. The aim of this study was to discuss and illustrate the role of MDCTU, on a 32-row CT scanner in the evaluation a variety of entities that were frequently associated with microscopic hematuria in adults. This prospective cohort study was performed in the period of August 2013 to October 2014. Fifty positive participants to microscopic hematuria were examined at the radiology department of Alnilin Diagnostic Medical Center and Antalya Medical Center. Computed tomography urography (CTU) scanning was performed using two powerful performances, high speed multi-detector row on 32-row CT scanners (Siemens Healthcare Global, Somatom Emotion Duo Eco). Statistical analysis was done through the standard Statistical Package for the Social Sciences (SPSS Inc., Chicago, IL, USA) version 15 for windows. MDCTU established the correct cause of microscopic hematuria in (44;88%) of participants. In (6;12%) of participants, no cause of hematuria was identified based on the standard of references. The causes of hematuria in (41;82%) participants were diseases in the upper urinary tract, while urinary bladder neoplasms (2;4%) and diverticulum (1;2%) were the causes of hematuria (3;6%) in the lower urinary tract. Thirty two-row MDCTU scanner demonstrated satisfactory results in the investigation of microscopic hematuria, being able to demonstrate a wide spectrum of diseases affecting the urinary tract is the main advantage of the technique. 展开更多
关键词 HEMATURIA Imaging Three-Dimensional multi-detector COMPUTED Tomography UROLOGIC Diseases
暂未订购
Design of Digital Multi-Radian Phase Detector on J-TEXT
12
作者 李俊 杨州军 +2 位作者 高丽 刘明海 庄革 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第10期974-977,共4页
A real time system used to detect phase difference between two sinusoidal signals is proposed in this paper. The system is designed to process the phase signal of the far-infrared (FIR) hydrogen cyanide (HCN) inte... A real time system used to detect phase difference between two sinusoidal signals is proposed in this paper. The system is designed to process the phase signal of the far-infrared (FIR) hydrogen cyanide (HCN) interferometer on J-TEXT. It is based on zero-crossing detection and makes use of the digital circuit. Compared with a traditional zero-crossing phase detector, it doesn't need to sacrifice the time resolution to expand the phase range. The phase difference is divided into two parts, the integer part and the fraction part. In each detecting cycle, they are detected separately. It outputs digital signals that are more stable for transmission. A prototype was built on J-TEXT using discrete components. A practical method is proposed to deal with the counting error caused by the deviation of electronic components in manufacture. Reasonable results were obtained on the prototype. The phase resolution reaches 2π/64 in test, and can still be improved by raising the clock frequency. 展开更多
关键词 phase detector multi-radian DIGITAL HCN interferometer
在线阅读 下载PDF
Optimization of Contrast Material Dose for Abdominal Multi-Detector Row CT: Predicting Patient Lean Body Weight by Using Preliminary Transverse CT Images
13
作者 Antonino Guerrisi Daniele Marin +4 位作者 Huiman Barnhart Lisa Ho Thomas L. Toth Carlo Catalano Rendon C. Nelson 《Advances in Computed Tomography》 2014年第1期1-10,共10页
Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detec... Estimated LBW could be used to determine the contrast material dose and rate during MDCT. The aim of this study is to test the accuracy of a technique for estimation of lean body weight (LBW) from a single multi-detector row computed tomographic (MDCT) abdominal image, using a bioelectrical body composition analyzer scale as the reference standard. CT images of 21 patients with previously measured LBW (mLBW) were processed using computer-assisted, vendor-specific software (Advantage Windows 4.2;GE Healthcare, Inc). For each transverse image, a fat-fraction was automatically measured as the number of fat pixels (-200 to -50 HU) divided by the total number of pixels having an attenuation value ≥-200 HU. Estimated LBW (eLBW) of five single contiguous sections was calculated in each of three abdominal regions (upper abdomen, mid abdomen and pelvis) by multiplying TBW by (1 – fat-fraction). Bland-Altman plot with limits of agreement was used to assess agreement between mLBW and eLBW. The mean mLBW for all patients was 56 kg (range, 39 - 75 kg). Mean differences and limits of agreement between mLBW and eLBW measurements for the upper abdomen, mid abdomen and pelvis reported were -8.9 kg (-25.6 kg, +7.5 kg), -10.6 kg (-27.7 kg, +6.4 kg), and +0.5 kg (-12.8 kg, +13.8 kg) respectively. eLBW deriving directly from a transverse CT image of the pelvis can accurately predict mLBW. 展开更多
关键词 LEAN Body WEIGHT multi-detector CT CONTRAST DOSE
暂未订购
Usefulness of an Anisotropic Diffusion Method in Cerebral CT Perfusion Study Using Multi-Detector Row CT
14
作者 Kenya Murase Takafumi Nanjo +2 位作者 Yoshifumi Sugawara Masaaki Hirata Teruhito Mochizuki 《Open Journal of Medical Imaging》 2015年第3期106-116,共11页
Purpose: To present an application of the anisotropic diffusion (AD) method to improve the accuracy of the functional images of perfusion parameters such as cerebral blood flow (CBF), cerebral blood volume (CBV) and m... Purpose: To present an application of the anisotropic diffusion (AD) method to improve the accuracy of the functional images of perfusion parameters such as cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) generated from cerebral CT perfusion studies using multi-detector row CT (MDCT). Materials and Methods: Continuous scans (1 sec/rotation ×60 sec) consisting of four 5-mm-thick contiguous slices were acquired after an intravenous injection of iodinated contrast material in 6 patients with cerebrovascular disease using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. New image data were generated by thinning out the above original images at an interval of 2 sec or 3 sec. The thinned-out images were then interpolated by linear interpolation to generate the same number of images as originally acquired. The CBF, CBV and MTT images were generated using deconvolution analysis based on singular value decomposition. Results: When using the AD method, the correlation coefficient between the MTT values obtained from the original and thinned-out images was significantly improved. Furthermore, the coefficients of variation of the CBF, CBV and MTT values in the white matter significantly decreased as compared to not using the AD method. Conclusion: Our results suggest that the AD method is useful for improving the accuracy of the functional images of perfusion parameters and for reducing radiation exposure in cerebral CT perfusion studies using MDCT. 展开更多
关键词 ANISOTROPIC Diffusion Method CEREBRAL CT PERFUSION STUDY multi-detector Row CT Radiation Exposure
暂未订购
A Multi-Detector Security Architecture with Local Feature-Level Fusion for Multimodal Biometrics
15
作者 Sorin Soviany Sorin Puscoci Cristina Soviany 《通讯和计算机(中英文版)》 2013年第9期1200-1218,共19页
关键词 生物特征识别 特征级融合 多探测器 安全架构 多模态 生物识别系统 识别模型 生物识别技术
在线阅读 下载PDF
Predictive Factors of the Presence and Number of Noncalcified Coronary Plaque in Japanese Patients with Zero Coronary Artery Calcium Score Using 64-Slice Multi-Detector Computed Tomography
16
作者 Yoshiki Noda Ryo Matsutera +8 位作者 Yoshinori Yasuoka Kiyoshi Kume Hidenori Adachi Susumu Hattori Ryo Araki Motohiro Kosugi Yasuaki Kohama Tetsufumi Nakashima Tatsuya Sasaki 《Advances in Computed Tomography》 2013年第3期112-120,共9页
Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Result... Background: Factors that can predict the presence and number of noncalcified coronary plaques (NCP) in Japanese patients with zero coronary artery calcium scores (CACS) essentially remain undefined. Methods and Results: We assessed independent predictors of the presence and number of segments with NCP in 111 Japanese patients with zero CACS who underwent 64-slice multi-detector computed tomography at our hospital. Thirty five patients (32%) had NCP, and 24 patients (22%) had ≥ 2 NCPs. Multiple logistic regression analysis revealed that significant predictors for the presence of NCP were age (odds ratio [OR]: 1.06, 95% confidence interval [CI] 1.01 - 1.11, p = 0.021), male (OR: 3.61, 95% CI 1.40 - 9.35, p = 0.008) and diabetes mellitus (OR: 3.10, 95% CI 1.02 - 9.45, p = 0.046), and those for the presence of ≥ 2 NCPs were age (OR: 1.08, 95% CI 1.02 - 1.15, p = 0.007) and a current smoking habit (OR: 5.09, 95% CI 1.00 - 25.74, p = 0.049). Multiple linear regression analysis identified advanced age, male gender and diabetes mellitus as independent predictors of the number of NCPs. A novel score calculated from the above four predictors showed moderate accuracy for a diagnosis of NCP and ≥ 2 NCPs, with areas under receiver operating curves of 0.738 and 0.736, respectively. Conclusions: Male Japanese patients with zero CACS, advanced age, diabetes mellitus and a current smoking habit might have NCPs. 展开更多
关键词 ZERO CORONARY Artery Calcium Score NUMBER of Noncalcified CORONARY PLAQUE 64-Slice multi-detector Computed Tomography Japanese Patients
暂未订购
Coronary Artery Anomalies Detected by Multi-Detector Computed Tomography: A Single Centre Experience
17
作者 Basma Hammad Eman El-sharkawy +6 位作者 Yasser Morsi Noha Shabaan Salah Eltahan Mohamed Elshafi Shady Abohashem Tanveer Mir Mostafa Elwany 《World Journal of Cardiovascular Diseases》 2023年第6期261-274,共14页
Background: Coronary artery anomalies (CAA) prevalence represents less than 1% of congenital heart diseases. It includes anomalies in origin, course, and termination. Its detection has been easier with advances i... Background: Coronary artery anomalies (CAA) prevalence represents less than 1% of congenital heart diseases. It includes anomalies in origin, course, and termination. Its detection has been easier with advances in imaging techniques using multi-detector computed tomography (MDCT). MDCT helps not only detection of the anomalous origin, but it allows delineation of the course and termination of the arteries, differentiation between benign and malignant courses, and guiding therapeutic interventions. Results: There were consecutive patients with a low-to-intermediate probability of coronary artery disease scanned with 128 MDCT. Each patient underwent a non-contrast prospective gating acquisition for coronary calcium scoring followed by contrast-enhanced helical retrospective gated scans for the detection of coronary artery origin, course, termination, and detection of concomitant atherosclerosis. We scanned 1000 patients with a mean age of 57.5 ± 8.3, and 68% were males. Thirty-two anomalies were noted (3.2%) including;nineteen (1.9%) anomalous origin from the opposite sinus, three (0.3%) anomalous left coronary arteries from the pulmonary artery (ALCAPA), one (0.1%) super dominant left anterior descending artery (LAD) giving origin to the posterior descending artery (PDA), three single coronary arteries (0.3%)in which the left main (LM) and right coronary arteries were originating with a common stem from the right coronary sinus (RCS)and the LM took a pre-pulmonic course. Along with six (0.6%) dual LAD including five (0.5%) patients with type I (short LAD and long diagonal), there was one (0.1%) type 4 with an extra LAD originating from the RCS with a pre-pulmonic course. Conclusions: MDCT allows easy detection of coronary anomalies with high spatial resolution and overcomes limitations in conventional invasive coronary angiography. Based on our study we recommend the use of MDCT as an efficient and feasible modality for the diagnosis of coronary anomalies once this pathology is clinically suspected. 展开更多
关键词 Coronary Artery Anomalies Spatial Resolution multi-detector Computed Tomography
暂未订购
MDCT胆囊癌T分期诊断性能对术前护理评估的应用价值
18
作者 朱慧 《河北北方学院学报(自然科学版)》 2026年第2期29-32,共4页
目的探讨多排螺旋CT胆囊癌分期诊断性能对术前护理评估的应用价值。方法回顾性分析151例经手术证实的T1(n=49)或T2(n=102)期胆囊癌患者的多排螺旋计算机体层摄影(multi-detector spiral computer tomography,MDCT)资料,通过ROC曲线分析... 目的探讨多排螺旋CT胆囊癌分期诊断性能对术前护理评估的应用价值。方法回顾性分析151例经手术证实的T1(n=49)或T2(n=102)期胆囊癌患者的多排螺旋计算机体层摄影(multi-detector spiral computer tomography,MDCT)资料,通过ROC曲线分析评估MDCT胆囊癌T分期的诊断性能,并计算敏感度、特异度、准确度等指标。结果不同T分期的ROC曲线下面积范围为0.69~0.80(中位数0.77)。参与诊断的影像科医生总体诊断准确率为78%(95%CI:71%~84%),经验丰富的医生敏感度较高但特异度较低(P<0.001),观察者间一致性一般(κ=0.36)。不同形态肿瘤(息肉型、息肉伴壁增厚型、壁增厚型)的诊断准确率分别为63%、78%和87%。结论MDCT诊断胆囊癌T1和T2分期的准确性有限,且存在观察者间差异。护理人员应了解这一局限性,在术前准备、患者教育和多学科协作中充分考虑影像学评估的不确定性。 展开更多
关键词 多排螺旋计算机体层摄影 胆囊癌 T分期 护理评估 术前准备
暂未订购
Multi-h CPM信号的减少状态多符号差分非相干检测
19
作者 钟声 谢顺钦 +1 位作者 张健 杨春 《电视技术》 北大核心 2014年第9期165-169,共5页
针对多指数连续相位调制(Multi-h CPM)载波恢复困难且实现复杂度高的难题,提出了一种适用于Multi-h CPM信号的减少状态多符号差分非相干检测算法。该算法利用多符号差分信息进行分支度量计算的同时引入参考相位信号,实现了具有残留载波... 针对多指数连续相位调制(Multi-h CPM)载波恢复困难且实现复杂度高的难题,提出了一种适用于Multi-h CPM信号的减少状态多符号差分非相干检测算法。该算法利用多符号差分信息进行分支度量计算的同时引入参考相位信号,实现了具有残留载波频偏校正的非相干序列检测,并且结合逐幸存处理技术,利用幸存路径上的假设判决信息减少了网格状态数。通过计算和搜索接收信号所有可能调制指数序列所对应的分支度量信息实现了调制指数的估计与同步。计算机仿真结果表明,与相干最大似然序列检测相比,该算法能够以较小的性能损失获得其实现复杂度的降低,而且当存在残留载波频偏时,该算法的检测性能也较为稳健。 展开更多
关键词 多指数连续相位调制 减少状态 多符号差分 非相干检测 逐幸存处理
在线阅读 下载PDF
不同格网尺度下生态系统服务价值空间分异及影响因素分析--以秦岭西安段为例 被引量:6
20
作者 马超群 弋志强 +2 位作者 员学锋 张硕蒙 张莎莎 《水土保持研究》 北大核心 2025年第1期389-399,共11页
[目的]探究生态系统服务价值空间分异的尺度效应,为秦岭地区的生态保护和经济发展决策提供参考。[方法]运用改进当量因子法,计算了2020年秦岭西安段5 km,3 km,2 km,1 km和0.5 km共5个格网尺度水平上的生态系统服务价值;采用空间自相关... [目的]探究生态系统服务价值空间分异的尺度效应,为秦岭地区的生态保护和经济发展决策提供参考。[方法]运用改进当量因子法,计算了2020年秦岭西安段5 km,3 km,2 km,1 km和0.5 km共5个格网尺度水平上的生态系统服务价值;采用空间自相关分析和冷热点分析归纳了不同尺度下地均ESV空间分异特征;并利用地理探测器对各尺度下的影响因素作用强度进行定量分析。[结果](1)地均ESV总体上呈北低南高的分布格局,具有小分散、大集聚的空间分布特征,并随尺度降低,其局部越丰富,但整体性降低;(2)2 km尺度适合进行宏观分析和做整体性布局规划,1 km尺度适合进行水域变化对区域ESV影响的研究;(3)格网尺度越小,各影响因素内部差异增加,其整体性特征减少,局部特征差异凸显,空间分异性增强;(4)人类活动带来的土地利用方式转变显著影响区域生态系统服务价值,多因素耦合作用显著影响区域地均ESV空间分异,随尺度降低,其影响减弱。[结论]秦岭西安段的生态保护要重点关注区域土地利用性质的转变,可继续加强退耕还林政策,管控建设用地的规模,在兼顾生态保护的基础上,制定经济发展的布局规划。 展开更多
关键词 生态系统服务价值 空间分异 地理探测器 多尺度 秦岭西安段
在线阅读 下载PDF
上一页 1 2 38 下一页 到第
使用帮助 返回顶部