期刊文献+
共找到2,638篇文章
< 1 2 132 >
每页显示 20 50 100
A Composite Multi-Port Hybrid DC Circuit Breaker with DC Power Flow and Fault Current Limitation Abilities
1
作者 Xiaoya Chen Chao Zhang +5 位作者 Xufeng Yuan Wei Xiong Zhiyang Lu Huajun Zheng Yutao Xu Zhukui Tan 《Energy Engineering》 2026年第3期306-325,共20页
To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distributio... To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization. 展开更多
关键词 DC power grid DC power flow control fault current limiting fault isolation hybrid DC circuit breaker
在线阅读 下载PDF
The Overcurrent Limiting Method of GF-SVG in a Wind Farm Based on Adaptive Virtual Reactance
2
作者 Jikai Chen Jiawei Wang +3 位作者 Jiayang Zhang Shuangshuang Yao Qianxin Li Haoru Li 《Energy Engineering》 2025年第9期3703-3718,共16页
As a new dynamic reactive power compensator,the grid-forming Static Var Generator(GF-SVG)can not only provide reactive power-voltage support,but also has inertial support capability.It has been experimentally deployed... As a new dynamic reactive power compensator,the grid-forming Static Var Generator(GF-SVG)can not only provide reactive power-voltage support,but also has inertial support capability.It has been experimentally deployed in many wind farms.However,studies have shown that when the three-phase short-circuit fault occurs in the wind farm,the transient overcurrent during the fault occurrence and fault clearance is suppressed,making it difficult for GF-SVG to use traditional fixed virtual impedance.Aiming at the problem,firstly,the influence of virtual reactance on control stability is analyzed using the GF-SVG’s current open-loop transfer function.Secondly,based on the existing current limitation strategies of GF-SVG,an adaptive virtual reactance current limitation strategy suitable for symmetrical faults of the power grid is proposed,which limits GF-SVG’s transient overcurrent during fault occurrence and fault clearance stage to the tolerance range of GF-SVG’s power devices.Based on the GF-SVG’s active power loop and reactive power loop small signal models,the availability of the proposed adaptive virtual reactance in suppressing the DC voltage drop of GF-SVG is analyzed,and shortening the transient overvoltage recovery time of the wind farm after the fault clearance is also discussed.Finally,electromagnetic simulation proves the effectiveness and correctness of the proposed adaptive current limitation method. 展开更多
关键词 GF-SVG wind farm current limitation virtual reactance STABILITY
在线阅读 下载PDF
Transient Power Angle Control for a Droop-controlled Voltage Source Converter Considering Fault Current Limitation
3
作者 Pingjuan Ge Fan Xiao +3 位作者 Chunming Tu Qi Guo Zekun Xiao Weijie Xie 《CSEE Journal of Power and Energy Systems》 2025年第5期2283-2292,共10页
Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging asp... Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging aspects of VSCs under fault conditions.Therefore,fault current limitation and power angle stability are essential conditions for the safe operation of a VSC.Thus,the transient characteristics of a VSC are analyzed to guide transient control.Then,a transient control method for a VSC,considering both fault current limitation and power angle stability,is proposed.With the proposed method,power angle stability is realized by optimizing the P-f controller.On the basis of power angle control,the Q-U controller and inner current controller are improved to effectively suppress the fault current.Finally,relevant tests are performed to verify the proposed method. 展开更多
关键词 Fault current limitation transient control strategy transient stability analysis voltage source converter
原文传递
Impacts of Reactive Power Control Dynamics on Transient Stability of Grid-forming Converters Considering Current Saturation:Analysis and Enhancement
4
作者 Jinming Xu Hanxu Diao +3 位作者 Zihan Ling Jiarong Kan Yunhu Luo Shaojun Xie 《CSEE Journal of Power and Energy Systems》 2026年第1期56-70,共15页
The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited ... The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy. 展开更多
关键词 current limit grid-forming converter reactive power control transient stability
原文传递
Investigation on the Arc Ignition Characteristics and Energy Absorption of Liquid Metal Current Limiter Based on Self-Pinch Effect 被引量:3
5
作者 琚兴宝 孙海顺 +1 位作者 杨倬 张俊民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期531-537,共7页
The GaInSn liquid metal current limiter based on the fluid pinch effect has broad application prospects due to its particular properties. However, the limited rated current and abil- ity of power dissipation are the c... The GaInSn liquid metal current limiter based on the fluid pinch effect has broad application prospects due to its particular properties. However, the limited rated current and abil- ity of power dissipation are the critical problems for its wide application. Firstly, the temperature distribution of the liquid metal current limiter (LMCL) was obtained by experiments with a rated current of 1 kA and the arc ignition phenomenon was observed with 1.5 kA, which indicates that the rated current is mainly limited by the arc rather than the high temperature compared to the traditional switchgears. Furthermore, an improved method is proposed by adding the paralleled pure resistance, impedance or another LMCL element to protect the setup from the fault energy concentration in the setup. The problem of a slower arc voltage increasing rate can be solved by adding a paralleled impedance with suitable parameters. Finally, the current limiting properties based on the improved method were investigated and the alternating oscillating current was found between two paralleled LMCL elements owing to their deviation of arc ignition in reality. 展开更多
关键词 ARC liquid metal current limiter fluid pinch effect
在线阅读 下载PDF
The Continuation Power Flow Considering Both Generator Excitation Current Limits and Armature Current Limits 被引量:4
6
作者 ZHAO Jinquan QIAN Tianneng 《中国电机工程学报》 EI CSCD 北大核心 2012年第22期I0016-I0016,10,共1页
在传统连续潮流算法中,发电机无功限制采用定上、下限值来处理,随着有功负荷增加,无功限值通常不变,得到的电压稳定裕度偏大。根据同步发电机的无功出力特性,提出同时计及发电机励磁电流约束和电枢电流约束的连续潮流模型和方法。当相... 在传统连续潮流算法中,发电机无功限制采用定上、下限值来处理,随着有功负荷增加,无功限值通常不变,得到的电压稳定裕度偏大。根据同步发电机的无功出力特性,提出同时计及发电机励磁电流约束和电枢电流约束的连续潮流模型和方法。当相应参数越限时,将发电机节点转换为励磁恒定模型或者电枢电流恒定模型进行计算。所提PV、PEq、PIa节点类型双向转换逻辑可在潮流迭代内进行发电机限制模式的转换,模拟实际系统无功能力的变化。分岔点类型识别模块可以识别崩溃点类型及关键约束。通过新英格兰39节点算例的仿真,证明所提算法是有效的。 展开更多
关键词 发电机励磁 连续潮流 电枢电流 电流限制 功率限制 负荷裕度 稳定评估 CPF
原文传递
Water Dissociation Phenomena on a Bipolar Membrane──Current-voltage Curve in Relation with IonicTransport and Limiting Current Density 被引量:1
7
作者 XU Tong-wen YANG Wei-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期457-464,共8页
The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer ... The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer exists at the junction of a bipolar membrane, which is coincided with the viewpoint of the most literatures, but we also consider that the thickness and conductivity of this layer is not only related with the increase of the applied voltage but also with the limiting current density. Below the limiting current density, the thickness of the depletion layer keeps a constant and the conductivity decreases with the increase of the applied voltage; while above the limiting current density, the depletion thickness will increase with the increase of the applied voltage and the conductivity keeps a very low constant. Based on the data reported in the literatures and independent determinations, the limiting current density was calculated and the experimental curves Ⅰ-Ⅴ in the two directions were com 展开更多
关键词 Bipolar membrane Water dissociation Ionic transport limiting current density
在线阅读 下载PDF
Current self-limitation in a transverse nanosecond discharge with a slotted cathode 被引量:1
8
作者 N A ASHURBEKOV K O IMINOV +1 位作者 O A POPOV G S SHAKHSINOV 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第3期69-74,共6页
A high-voltage transverse pulsed nanosecond discharge with a slotted hollow cathode was found to be a source of high-energy (few kV) ribbon electron beams. Conditions for the formation and extinction of electron bea... A high-voltage transverse pulsed nanosecond discharge with a slotted hollow cathode was found to be a source of high-energy (few kV) ribbon electron beams. Conditions for the formation and extinction of electron beams were experimentally studied in discharges in helium at pressures of 1-100 Torr. It was found that interaction of fast electrons with a non-uniform electric field near the slotted cathode led to limitation of the magnitude of the discharge current. A physical model was developed to describe the discharge current self-limitation that was in satisfactory agreement with the experimental results. Some technical solutions that are expected to increase the upper current limits in transverse nanosecond discharge are discussed. 展开更多
关键词 nanosecond discharge electron beams upper current limitation slotted cathode
在线阅读 下载PDF
Study of the Fast-Closing Switch Used for Fault Current Limiters in Power System 被引量:1
9
作者 邹积岩 董恩源 陈金祥 《Journal of Shanghai University(English Edition)》 CAS 2002年第1期92-96,共5页
This paper presents a new type of fault current limiter (FCL) based on fast closing switch, which is composed of a capacitor bank and a reactor in series. The main control component is a fast closing switch connecte... This paper presents a new type of fault current limiter (FCL) based on fast closing switch, which is composed of a capacitor bank and a reactor in series. The main control component is a fast closing switch connected in parallel with the capacitors, which is driven by the electromagnetic repulsion force. It can response the order within 1 ms. When fault occurs, the switch closes and the capacitors are bypassed, and the fault current is limited by the reactor. Simulation analysis and experiment show that the electromagnetic repulsion force actuator can meet the demand of fast closing switch, it is feasible to develop the FCL with low cost and high reliability. 展开更多
关键词 fault current limiter (FCL) electromagnetic repulsion force fast closing switch simulation.
在线阅读 下载PDF
A novel fault current limiter topology design based on liquid metal current limiter 被引量:1
10
作者 Jinjin LI Xiongying DUAN +4 位作者 Weiying XIE Zhihui HUANG Minfu LIAO Dequan WANG Xiaotao HAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第8期113-123,共11页
The liquid metal current limiter(LMCL)is regarded as a viable solution for reducing the fault current in a power grid.But demonstrating the liquid metal arc plasma self-pinching process of the resistive wall,and reduc... The liquid metal current limiter(LMCL)is regarded as a viable solution for reducing the fault current in a power grid.But demonstrating the liquid metal arc plasma self-pinching process of the resistive wall,and reducing the erosion of the LMCL are challenging,not only theoretically,but also practically.In this work,a novel LMCL is designed with a resistive wall that can be connected to the current-limiting circuit inside the cavity.Specifically,a novel fault current limiter(FCL)topology is put forward where the novel LMCL is combined with a fast switch and current-limiting reactor.Further,the liquid metal self-pinch effect is modeled mathematically in three dimensions,and the gas-liquid two-phase dynamic diagrams under different short-circuit currents are obtained by simulation.The simulation results indicate that with the increase of current,the time for the liquid metal-free surface to begin depressing is reduced,and the position of the depression also changes.Different kinds of bubbles formed by the depressions gradually extend,squeeze,and break.With the increase of current,the liquid metal takes less time to break,but breaks still occur at the edge of the channel,forming arc plasma.Finally,relevant experiments are conducted for the novel FCL topology.The arcing process and current transfer process are analyzed in particular.Comparisons of the peak arc voltage,arcing time,current limiting efficiency,and electrode erosion are presented.The results demonstrate that the arc voltage of the novel FCL topology is reduced by more than 4.5times and the arcing time is reduced by more than 12%.The erosions of the liquid metal and electrodes are reduced.Moreover,the current limiting efficiency of the novel FCL topology is improved by 1%–5%.This work lays a foundation for the topology and optimal design of the LMCL. 展开更多
关键词 liquid metal current limiter(LMCL) arc plasma fault current limiter(FCL)topology
在线阅读 下载PDF
Relation between space-charge-limiting current and electric field enhancement factor at curved surface cathode 被引量:1
11
作者 刘国治 杨占峰 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期394-398,共5页
A two-dimensional solution of space-charge-limiting current for a high current vacuum diode with a spherical cathode is presented. The relation between space-charge-limiting current and electric field enhancement fact... A two-dimensional solution of space-charge-limiting current for a high current vacuum diode with a spherical cathode is presented. The relation between space-charge-limiting current and electric field enhancement factor at the cathode surface for the diode with a curved surface cathode is also discussed. It is shown that compared with the current given by the conventional Child-Langmuir law, which describes the one-dimensional space-charege-limiting current, the two-dimensional space-charge-limiting current in such a diode is enhanced due to the electric-field enhancement along the cathode surface. Among practical parameter ranges, enhancement factor ηb approximately satisfies ηb Aβn, where β is the electric field enhancement factor at the cathode surface, and n is a constant between 1 and 2, which is confirmed to be universal for the diodes with curved surface cathodes. 展开更多
关键词 DIODE space-charge-limiting current intense electron beam
原文传递
A Fault Current Limiting Hybrid DC Circuit Breaker 被引量:1
12
作者 Lei Huang Qian Zhang +1 位作者 Wenlei Liu Ruixue Liu 《Energy Engineering》 EI 2022年第2期621-636,共16页
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g... Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB. 展开更多
关键词 Fault current limiting hybrid DC circuit breaker(FCL-HCB) high voltage direct current(HVDC)grid fault current limiting fault current interruption DC circuit breaker
在线阅读 下载PDF
Space-charge limiting currents for magnetically focused intense relativistic electron beams
13
作者 李建清 莫元龙 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第9期2716-2720,共5页
The self-consistent differential equations, which describe a laminar-flow equilibrium state in a magnetically focused intense relativistic electron beam propagating inside a conducting waveguide, are presented. The ca... The self-consistent differential equations, which describe a laminar-flow equilibrium state in a magnetically focused intense relativistic electron beam propagating inside a conducting waveguide, are presented. The canonical angular momentum, Pe, defined under the conditions at the source, uniquely determines the possible solutions of these equations. By numerically solving these equations, the space-charge limited current and the externally applied magnetic field are obtained in a solid beam and a hollow beam in two cases of Pθ= 0 (magnetically shielded source) and Pθ= const. (immersed source) separately. It is shown that the hollow beam is more beneficial to the propagation of the intense relativistic beam through a drift tube than the solid beam. 展开更多
关键词 space-charge limiting current intense relativistic beam laminar-flow equilibrium state
原文传递
Identifying Diffusion Limiting Current to Unravel the Intrinsic Kinetics of Electrode Reactions Affected by Mass Transfer at Rotating Disk Electrode
14
作者 Mian-le Xu Wei Chen +3 位作者 Ling-wen Liao Zhen Wei Jun Cai Yan-xia Chen 《Chinese Journal of Chemical Physics》 SCIE EI CAS CSCD 2022年第5期797-804,I0012,共9页
Rotating disk electrode systems are widely used to study the kinetics of electrocatalytic reactions that may suffer from insufficient mass transfer of the reactants.Kinetic current density at certain overpotential cal... Rotating disk electrode systems are widely used to study the kinetics of electrocatalytic reactions that may suffer from insufficient mass transfer of the reactants.Kinetic current density at certain overpotential calculated by the Koutecky-Levich equation is commonly used as the metrics to evaluate the activity of electrocatalysts.However,it is frequently found that the diffusion limiting current density is not correctly identified in the literatures.Instead of kinetic current density,the measured current density normalized by diffusion limiting current density(j/jL)has also been frequently under circumstance where its validity is not justified.By taking oxygen reduction reaction/hydrogen oxidation reaction/hydrogen evolution reaction as examples,we demonstrate that identifying the actual diffusion limiting current density for the same reaction under otherwise identical conditions from the experimental data is essential to accurately deduce kinetic current density.Our analysis reveals that j/jLis a rough activity metric which can only be used to qualitatively compare the activity trend under conditions that the mass transfer conditions and the roughness factor of the electrode are exactly the same.In addition,if one wants to use j/jLto compare the intrinsic activity,the concentration overpotential should be eliminated. 展开更多
关键词 limiting current Kinetic current Mass transfer Activity metrics
在线阅读 下载PDF
An Active Inrush Current Limiter Based on SCR Phase Shift Control for EV Charging Systems 被引量:1
15
作者 Cedric Reymond Sebastien Jacques +1 位作者 Ghafour Benabdelaziz Jean-Charles Lebunetel 《Journal of Energy and Power Engineering》 2016年第4期247-257,共11页
This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems... This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems. In particular, a strategy, based on SCR (silicon controlled rectifier) phase, shift control in a mixed rectifier bridge with diodes and thyristors, is proposed. The challenge is to help designers optimize the triggering delay of SCRs to both limit the peak value of inrush current spikes and optimize the charge duration of the DC-link capacitor. A mathematical model (Mathcad engineering tool) has been defined to point out, the interest of a variable triggering delay to control SCRs to meet the expectations described previously. Experimental measurements using an industrial evaluation board of the AC-DC converter demonstrate the robustness of the method. 展开更多
关键词 EV charger AC-DC converter inrush current limiter SCR phase shift control.
在线阅读 下载PDF
TREATMENT OF INDUSTRIAL WASTEWATER FROM AN ALUMINA PLANT BY MEMBRANE (Ⅰ) ——Measurement of Limiting Current Density of Electrodialysis
16
作者 Zhou Kanggen Zhang Qixiou Luo Aiping (Department of Metallurgical Science and Engineering, Central South University of Technology, Changhsha 410083, China) Fu Chunsheng Shang Jihong Li Ming Huang Weiqing ① Zhu Xiaoqing ①(Department of Tech 《Journal of Central South University》 SCIE EI CAS 1999年第2期82-85,共4页
In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations ... In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations of limit current density, voltage drop of the unit membrane pair at the limiting current and desalination ratio at the limiting current were obtained. 展开更多
关键词 MEMBRANE separation ELECTRODIALYSIS limitING current density ALUMINA production wastewater TREATMENT
在线阅读 下载PDF
Placement optimization of Multi-Type fault current limiters based on genetic algorithm
17
作者 Guofeng Jin Jie Tan +2 位作者 Lingling Liu Chuan Wang Tiejiang Yuan 《Global Energy Interconnection》 EI CAS CSCD 2021年第5期501-512,共12页
The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial... The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization. 展开更多
关键词 Fault current limiter Genetic algorithm MULTI-OBJECTIVE Circuit breaker loss Short-circuit current PLACEMENT
在线阅读 下载PDF
Hybrid Operation of Fault Current Limiter and Thyristor Controlled Braking Resistor 被引量:1
18
作者 Masaki Yagami Junji Tamura 《Journal of Energy and Power Engineering》 2012年第4期601-608,共8页
The effectiveness of a combination of fault current limiter and thyristor controlled braking resistor on power system stability enhancement and damping turbine shaft torsional oscillations has been studied. If both de... The effectiveness of a combination of fault current limiter and thyristor controlled braking resistor on power system stability enhancement and damping turbine shaft torsional oscillations has been studied. If both devices operate at the same bus, the stabilization control scheme can be carried out continuously and with flexibility. As a result, the fault currents are limited, and the generator disturbances and the turbine shaft torsional oscillations are converged quickly. In this paper, the effectiveness of the combination of both devices has been demonstrated by considering 3LG (three-lines-to-ground) fault in a two-machine infinite bus system. Also, temperature rise effect of both devices with various resistance values and weights has been demonstrated. Simulation results indicate a significant power system stability enhancement and damping turbine shaft torsional oscillations as well as with allowable temperature rise. 展开更多
关键词 Fault current limiter thyristor controlled braking resistor fault current power system stability turbine shaft torsional oscillation temperature rise effect.
在线阅读 下载PDF
Bias Current Influence on the Characteristic of the Magnetic-controlled Switcher Type Fault Current Limiter
19
作者 潘艳霞 姜建国 《Journal of Shanghai Jiaotong university(Science)》 EI 2009年第3期359-364,共6页
A novel magnetic-controlled switcher type fault current limiter (FCL) for high voltage electric network is presented. The current limiting principle of the FCL and the bias current influence on the characteristic of... A novel magnetic-controlled switcher type fault current limiter (FCL) for high voltage electric network is presented. The current limiting principle of the FCL and the bias current influence on the characteristic of the FCL axe discussed. The experiments on the 220 V/50 A test model show that the FCL can limit the fault current swiftly and effectively. Under the normal state, the bias current adjustment can change the FCL voltage loss; under the fault state, the steady fault current can be easily adjusted to the preset level by bias current regulating. The experimental result is in accordance with the principle analysis and the FCL has the advantages of flexible control strategy and simple and reliable structure. 展开更多
关键词 fault current limiter (FCL) bias current fault current power systems
原文传递
Current Limiting Characteristic Analysis of Magnetic-controlled Switcher Type Fault Current Limiter
20
作者 潘艳霞 姜建国 《Journal of Donghua University(English Edition)》 EI CAS 2008年第6期626-631,共6页
A novel magnetic-controlled switcher type fault current limiter (FCL) based on the topology of the saturated iron core high temperature superconducting FCL is proposed. The magnetic field distribution of the FCL iron ... A novel magnetic-controlled switcher type fault current limiter (FCL) based on the topology of the saturated iron core high temperature superconducting FCL is proposed. The magnetic field distribution of the FCL iron core is analyzed by FEA software ANSYS. The current limiting characteristic is investigated by both 3-D field-circuit coupled simulation and Matlab. The experiments on the 220 V/50 A test model show that the FCL can limit the fault current swiftly and effectively,and the FCL has the advantages of simple and reliable structure, flexible control strategy. The simulation and experimental results prove that the theoretical expectation and current limiting performance is satisfactory for practical use. 展开更多
关键词 fault current limiter FCL ANSYS finite-element analysis (FEA) SUPERCONDUCTING
在线阅读 下载PDF
上一页 1 2 132 下一页 到第
使用帮助 返回顶部