Lightning stroke is one of the important causes of the accidents that occur on transmission lines.With the development of power system,the proportion of outages on transmission lines because of lightning stroke also i...Lightning stroke is one of the important causes of the accidents that occur on transmission lines.With the development of power system,the proportion of outages on transmission lines because of lightning stroke also increases.And according to the lightning accidents results,the lightning stroke characteristics is related to the time factors tightly.In order to analyze the correlativity between the lightning flashover amount and the time factors,about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000-2007 are investigated in this paper.The correlativity between the lightning flashover amount and the time factors is analyzed.According to the lightning stroke accidents investigation records,the lightning flashover amount of transmission line increases from the year of 2000 to 2007.In each year lightning flashovers mostly happen in the month of June,July and August.Similarly in each day the flashover amount also varies with the time of day obviously.These lightning flashovers mainly occur during 14:00-21:00 in the afternoon.The analysis results in this paper have a good agreement with the meteorological observations and lightning detection data of lightning location system(LLS).And these results provide good reference for the lightning protection work in power system.展开更多
This paper systematically studies the flashover probability of wind turbine blade lightning arrester and the impact of strong electromagnetic pulses on the local and surrounding wind turbines during lightning strikes....This paper systematically studies the flashover probability of wind turbine blade lightning arrester and the impact of strong electromagnetic pulses on the local and surrounding wind turbines during lightning strikes.The research results indicate that the flashover probability of direct lightning strikes by the wind turbine blade lightning arrester is almost negligible,and the strong electromagnetic pulse of wind turbine blade during lightning strikes has a serious impact on the electronic equipment of the machine,while the impact on the surrounding wind turbine is relatively small.At the same time,the calculation formula for the reflection of lightning current on the carbon brush between the wind turbine hub and the engine compartment during the flashing of the wind turbine blades is provided,and the calculation method for calculating the spatial gradient distribution of electromagnetic field intensity using Biot-Savart Law theorem is applied.The limitations of using wind turbine blades for lightning protection are pointed out,and a technical route for achieving wind turbine lightning safety is proposed,which can be used as a reference for wind turbine lightning protection technicians.展开更多
基金Supported by Eleventh—five Year Science and Teehnology Program of SGCC(SGKJ[2007]787).
文摘Lightning stroke is one of the important causes of the accidents that occur on transmission lines.With the development of power system,the proportion of outages on transmission lines because of lightning stroke also increases.And according to the lightning accidents results,the lightning stroke characteristics is related to the time factors tightly.In order to analyze the correlativity between the lightning flashover amount and the time factors,about 425 times lightning flashover on 187 lines in 10 power supply companies of 220 kV and 500 kV transmission lines during 2000-2007 are investigated in this paper.The correlativity between the lightning flashover amount and the time factors is analyzed.According to the lightning stroke accidents investigation records,the lightning flashover amount of transmission line increases from the year of 2000 to 2007.In each year lightning flashovers mostly happen in the month of June,July and August.Similarly in each day the flashover amount also varies with the time of day obviously.These lightning flashovers mainly occur during 14:00-21:00 in the afternoon.The analysis results in this paper have a good agreement with the meteorological observations and lightning detection data of lightning location system(LLS).And these results provide good reference for the lightning protection work in power system.
基金Research Project on Lightning Protection Technology for 35 kV Collector Lines in Wuxuan Qinglan Wind Farm(SFC/WXY-ZX-FW-23-008)Strong Electromagnetic Pulse Protection(Lightning)Effect in Guangdong Yuedian Zhuhai Biqing Bay Sea Wind Field and Real-time Monitoring Technology Research and Development Project of Grounding ResistanceResearch and Application Demonstration Project of Lightning Protection Technology for Offshore and Island Wind Field of China General Nuclear New Energy South China Branch.
文摘This paper systematically studies the flashover probability of wind turbine blade lightning arrester and the impact of strong electromagnetic pulses on the local and surrounding wind turbines during lightning strikes.The research results indicate that the flashover probability of direct lightning strikes by the wind turbine blade lightning arrester is almost negligible,and the strong electromagnetic pulse of wind turbine blade during lightning strikes has a serious impact on the electronic equipment of the machine,while the impact on the surrounding wind turbine is relatively small.At the same time,the calculation formula for the reflection of lightning current on the carbon brush between the wind turbine hub and the engine compartment during the flashing of the wind turbine blades is provided,and the calculation method for calculating the spatial gradient distribution of electromagnetic field intensity using Biot-Savart Law theorem is applied.The limitations of using wind turbine blades for lightning protection are pointed out,and a technical route for achieving wind turbine lightning safety is proposed,which can be used as a reference for wind turbine lightning protection technicians.