期刊文献+
共找到114篇文章
< 1 2 6 >
每页显示 20 50 100
Design of insulation support system of 120 keV positive ion source accelerator
1
作者 Wen DENG Yahong XIE +5 位作者 Yuming GU Yunfei JIANG Longbin LIU Fang WANG Jianglong WEI Chundong HU 《Plasma Science and Technology》 2025年第1期128-133,共6页
In order to support the physical research on the EAST tokamak,a new positive ion source with designed beam energy of 120 keV was proposed to be developed.Accelerator structure is one of the key components of the ion s... In order to support the physical research on the EAST tokamak,a new positive ion source with designed beam energy of 120 keV was proposed to be developed.Accelerator structure is one of the key components of the ion source.Through the finite element analysis method,the electrostatic analyses of insulators and grid plates were carried out,the material and structure parameters of insulators were determined.The maximum electric field around each insulator is about 4 kV/mm,and the maximum electric field between grids is about 14 kV/mm,which can meet the 120 keV withstand voltage holding.The insulation system for the positive ion source accelerator with 120 keV is designed,and the connection and basic parameters of insulators and support flanges are analyzed and determined. 展开更多
关键词 positive ion source ACCELERATOR insulation support system electrostatic simulation
在线阅读 下载PDF
The development of data acquisition and processing application system for RF ion source 被引量:3
2
作者 Xiaodan ZHANG Xiaoying WANG +3 位作者 Chundong HU Caichao JIANG Yahong XlE Yuanzhe ZHAO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第7期124-129,共6页
As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and... As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi- threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments. 展开更多
关键词 RF ion source data acquisition data processing TCP LZO algorithm
在线阅读 下载PDF
The development of data acquisition and control system for extraction power supply of prototype RF ion source 被引量:1
3
作者 Meichu HUANG Chundong HU +4 位作者 Yuanzhe ZHAO Caichao JIANG Yahong XIE Shiyong CHEN Qinglong CUI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第8期104-111,共8页
A 16 kV/20 A power supply was developed for the extraction grid of prototype radio frequency(RF) ion source of neutral beam injector. To acquire the state signals of extraction grid power supply(EGPS) and control ... A 16 kV/20 A power supply was developed for the extraction grid of prototype radio frequency(RF) ion source of neutral beam injector. To acquire the state signals of extraction grid power supply(EGPS) and control the operation of the EGPS, a data acquisition and control system has been developed. This system mainly consists of interlock protection circuit board, photoelectric conversion circuit, optical fibers, industrial compact peripheral component interconnect(CPCI) computer and host computer. The human machine interface of host computer delivers commands and data to program of the CPCI computer, as well as offers a convenient client for setting parameters and displaying EGPS status. The CPCI computer acquires the status of the power supply. The system can turn-off the EGPS quickly when the faults of EGPS occur. The system has been applied to the EGPS of prototype RF ion source. Test results show that the data acquisition and control system for the EGPS can meet the requirements of the operation of prototype RF ion source. 展开更多
关键词 RF ion source data acquisition control system TCP/IP protocol beam extraction
在线阅读 下载PDF
Design and test of cesium atomic concentration detection system based on TDLAS
4
作者 LIANG Lizhen LIU Shanhu +2 位作者 WU Yong WEI Jianglong XIE Yahong 《Optoelectronics Letters》 2025年第3期167-171,共5页
In order to better build the neutral beam injector with negative ion source(NNBI),the pre-research on key technologies has been carried out for the comprehensive research facility for fusion technology(CRFFT).Cesium s... In order to better build the neutral beam injector with negative ion source(NNBI),the pre-research on key technologies has been carried out for the comprehensive research facility for fusion technology(CRFFT).Cesium seeding into negative-ion sources is a prerequisite to obtain the required negative hydrogen ion.The performance of ion source largely depends on the cesium conditions in the source.It is very necessary to quantitatively measure the amount of cesium in the source during the plasma on and off periods(vacuum stage). 展开更多
关键词 atomic concentration tdlas CESIUM detection system ion source negative hydrogen ionthe negative ion source nnbi neutral beam injector
原文传递
Comprehensive research facility for negative ion source neutral beam injection at CRAFT:design and first
5
作者 Jianglong WEI Yahong XIE +40 位作者 Yuanlai XIE Caichao JIANG Yuanzhe ZHAO Yongjian XU Yuming GU Wei YI Wei LIU Lyuyang BU Dezhi YAN Zhimin LIU Sheng LIU Junjun PAN Shiyong CHEN Ling YU Qinglong CUI Shihua SONG Yuqing CHEN Ji WANG Ling LIU Shengmin PAN Bin GUO Zhigang ZHU Na WANG Junwei XIE Yuwen YANG Tengsai ZHU Lixin YANG Yufan LI Ning TANG Qianxu WANG Huihui HONG Bo LIU Yuqian LI Yang LI Yu GU Xufeng PENG Shanhu LIU Yong WU Xiancai MENG Chundong HU Lizhen LIANG 《Plasma Science and Technology》 2025年第4期1-11,共11页
Neutral beam injection(NBI)has been proven as a reliable heating and current drive method for fusion plasma.For the high-energy NBI system(particle energy>150 ke V)of large-scale fusion devices,the negative ion sou... Neutral beam injection(NBI)has been proven as a reliable heating and current drive method for fusion plasma.For the high-energy NBI system(particle energy>150 ke V)of large-scale fusion devices,the negative ion source neutral beam injection(NNBI)system is inevitable,which can obtain an acceptable neutralization efficiency(>55%).But the NNBI system is very complex and challengeable.To explore and master the key NNBI technology for future fusion reactor in China,an NNBI test facility is under development in the framework of the Comprehensive Research Facility for Fusion Technology(CRAFT).The initial goal of CRAFT NNBI facility is to achieve a 2 MW hydrogen neutral beam at the energy of 200–400 ke V for lasting 100 s.In the first operation of the CRAFT NNBI facility,a negative ion source with dual RF drivers was developed and tested.By using the 50 keV accelerator,the long-pulse and highcurrent extractions of negative hydrogen ions have been achieved and the typical values were 55.4 keV,7.3 A(~123 A/m^(2)),105 s and 55.0 keV,14.7 A(~248 A/m^(2)),30 s,respectively.By using the 200 keV accelerator,the megawatt-class negative hydrogen beam has also been achieved(135.9 keV,8.9 A,8 s).The whole process of the gas neutralization of negative ion beam,electric removal of residual ions,and beam transport have been demonstrated experimentally. 展开更多
关键词 beam acceleration magnetic confinement fusion negative ion source neutral beam injection(Some figures may appear in colour only in the online journal)
在线阅读 下载PDF
Synchronous Output Control System of Two Megawatt Hot Cathode Bucket Ion Sources for NBI
6
作者 赵远哲 吴德云 +5 位作者 胡纯栋 张小丹 崔庆龙 张睿 林宇莲 盛鹏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第3期247-250,共4页
Synchronous output of one beam line's two megawatt hot cathode bucket ion sources is required when Neutral Beam Injector (NBI) works on the Experimental Advanced Supercon- ducting Tokamak (EAST). Neutral Beam Inj... Synchronous output of one beam line's two megawatt hot cathode bucket ion sources is required when Neutral Beam Injector (NBI) works on the Experimental Advanced Supercon- ducting Tokamak (EAST). Neutral Beam Injector Control System (NBICS) realizes synchronous output and asynchronous output of two ion sources with network communication and hardware triggers. And the synchronous time can be set by operator. In synchronous mode, two megawatt hot cathode bucket ion sources can produce neutral beams at any relative time with higher energy than two sources' asynchronous output. Two megawatt hot cathode bucket ion sources' synchronous output makes an important contribution to NBI system of 4-8 MW with 10-100 s pulse length and provides more and better parameters for EAST physical experiments. 展开更多
关键词 EAST NBI synchronous output ion source MEGAWATT
在线阅读 下载PDF
Simulation and fabrication of vertical channel transistors with self-aligned high-κ metal gates using ion implantation for source/drain doping
7
作者 Penghui Sun Yongkui Zhang Jun Luo 《Journal of Semiconductors》 2025年第12期62-70,共9页
In vertical channel transistors(VCTs),source/drain ion implantation(I/I)represents a significant technical challenge due to inherent three-dimensional structural constraints,which induce complications such as difficul... In vertical channel transistors(VCTs),source/drain ion implantation(I/I)represents a significant technical challenge due to inherent three-dimensional structural constraints,which induce complications such as difficulties in dummy gate forma-tion and shadowing effects of I/I.This article systematically investigates the impact of different implantation conditions on the performance of VCTs with and without dummy gates through TCAD simulation.It reveals the significant role of the lightly doped regions(LDRs)naturally formed due to ion implantation in source/drain of VCTs.Furthermore,it was found that VCT with-out dummy gates can achieve an approximately 27%increase in on-state current(Ion)under the same implantation conditions,and can greatly simplify the process flow and reduce costs.Finally,N-type and P-type VCTs were successfully fabricated using this implantation method. 展开更多
关键词 vertical channel transistor source/drain ion implantation on-state current dummy gates
在线阅读 下载PDF
Power Law Distributions in the Experiment for Adjustment of the Ion Source of the NBI System
8
作者 韩筱璞 胡纯栋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第6期3102-3104,共3页
The experiential adjustment process in an experiment on the ion source of the neutral beam injector system for the HT-7 Tokamak is reported in this paper. With regard to the data obtained in the same condition, in arr... The experiential adjustment process in an experiment on the ion source of the neutral beam injector system for the HT-7 Tokamak is reported in this paper. With regard to the data obtained in the same condition, in arranging the arc current intensities of every shot with a decay rank, the distributions of the arc current intensity correspond to the power laws, and the distribution obtained in the condition with the cryo-pump corresponds to the double Pareto distribution. Using the similar study method, the distributions of the arc duration are close to the power laws too. These power law distributions are formed rather naturally instead of being the results of purposeful seeking. 展开更多
关键词 power law distribution adjustment experiment ion source double Pareto distribution
在线阅读 下载PDF
Development of data acquisition and over-current protection systems for a suppressor-grid current with a neutral-beam ion source
9
作者 刘伟 胡纯栋 +5 位作者 刘胜 宋士花 汪金新 王艳 赵远哲 梁立振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期154-158,共5页
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin... Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission. 展开更多
关键词 neutral beam injection high-current ion source suppression grid current data acquisition and protection system
在线阅读 下载PDF
A NEW ELECTRON IMPACT STORAGE ION SOURCE 被引量:1
10
作者 徐贞林 田锡惠 《Transactions of Tianjin University》 EI CAS 1995年第2期138+133-137,共6页
A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the o... A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the overall performance of the instrument has been improved greatly with a mass resolving power up to 3 500. The conditions of the second order of the focus are given and the storage ability is proved. The competer simulations and experiment results are given, too. 展开更多
关键词 electron impact ion source time of flight mass spectrometer
在线阅读 下载PDF
Commissioning of a high-resolution collinear laser spectroscopy apparatus with a laser ablation ion source 被引量:8
11
作者 Shi-Wei Bai Xiao-Fei Yang +13 位作者 Shu-Jing Wang Yong-Chao Liu Peng Zhang Yin-Shen Liu Han-Rui Hu Yang-Fan Guo Jin Wang Ze-Yu Du Zhou Yan Yun-Kai Zhang Yan-Lin Ye Qi-Te Li Yu-Cheng Ge Chuang-Ye He 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第1期98-106,共9页
Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Io... Collinear laser spectroscopy is a powerful tool for studying the nuclear spins,electromagnetic moments,and charge radii of exotic nuclei.To study the nuclear properties of unstable nuclei at the Beijing Radioactive Ion-beam Facility(BRIF)and the future High Intensity Heavy-ion Accelerator Facility(HIAF),we developed a collinear laser spectroscopy apparatus integrated with an offline laser ablation ion source and a laser system.The overall performance of this state-of-the-art technique was evaluated,and the system was commissioned using a bunched stable ion beam.The high-resolution optical spectra for the 4s ^(2)S_(1/2)→4p^(2)P_(3/2)(D2)ionic transition of ^(40;42;44;48)Ca isotopes were successfully measured.The extracted isotope shifts relative to ^(40)Ca showed excellent agreement with the literature values.This system is now ready for use at radioactive ion beam facilities such as the BRIF and paves the way for the further development of higher-sensitivity collinear resonance ionization spectroscopy techniques. 展开更多
关键词 Nuclear properties Collinear laser spectroscopy Laser-ablation ion source Photon detection Isotope shift
在线阅读 下载PDF
Energy properties and spatial plume profile of ionic liquid ion sources based on an array of porous metal strips 被引量:7
12
作者 Xinyu LIU Xiaoming KANG +1 位作者 Hanwen DENG Yiming SUN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第12期128-139,共12页
An ionic liquid ion source(ILIS)is a kind of high brightness ion source capable of providing high-speed positive or negative ion beams.This paper presents a miniaturized ILIS based on an array of porous metal strips.T... An ionic liquid ion source(ILIS)is a kind of high brightness ion source capable of providing high-speed positive or negative ion beams.This paper presents a miniaturized ILIS based on an array of porous metal strips.The porous emitter array,integrated with seven 10 mm long strips,is fabricated using wire electrical discharge machining(WEDM)combined with electrochemical etching.The assembled ILIS is 30 mm×30 mm×17.5 mm in size and weighs less than 25 g.A series of experiments,including anⅠ-Ⅴcharacteristic test,a retarding potential analyzer(RPA)test,and a spatial plume distribution test,have been conducted in vacuo to characterize the performance of the ILIS.Results show that the emitted current is up to about 800μA and ion transparency is as high as 94%.Besides,RPA curves reveal that the total fragmentation rate of the emitted particles accounts for 48.8%in positive mode and 59.8%in negative mode.Further,with the increase in applied acceleration voltage,the voltage loss rises while the energy efficiency decreases.It is also found that the plume perpendicular to the strips has a higher divergence than the one parallel to the strips.A numerical simulation by COMSOL reveals that the electric field distribution between the two electrodes results in such a spatial plume profile. 展开更多
关键词 ELECTROSPRAY ionic liquid ion source retarding potential analyzer energy distribution spatial plume profile
在线阅读 下载PDF
The Development of a Megawatt-Level High Current Ion Source 被引量:6
13
作者 HU Chundong XIE Yahong NBI team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第1期75-77,共3页
Neutral beam injection is one of the main plasma heating methods in nuclear fusion devices. In order to support the scientific study of the Experimental Advanced Superconducting Tokamak (EAST), a megawatt-level high... Neutral beam injection is one of the main plasma heating methods in nuclear fusion devices. In order to support the scientific study of the Experimental Advanced Superconducting Tokamak (EAST), a megawatt-level high current ion source is designed and manufactured in the ASIPP, and the progress and preliminary test results will be presented in this paper. 展开更多
关键词 NBI ion source MEGAWATT high current
在线阅读 下载PDF
Laser ion source for heavy ion inertial fusion 被引量:3
14
作者 Masahiro Okamura 《Matter and Radiation at Extremes》 SCIE EI CAS 2018年第2期61-66,共6页
The proposed heavy ion inertial fusion(HIF)scenarios require ampere class low charge state ion beams of heavy species.The laser ion source(LIS)is recognized as one of the promising candidates of ion beam providers,sin... The proposed heavy ion inertial fusion(HIF)scenarios require ampere class low charge state ion beams of heavy species.The laser ion source(LIS)is recognized as one of the promising candidates of ion beam providers,since it can deliver high brightness heavy ion beams to accelerators.The design of LIS for the HIF depends on the accelerator structure and accelerator complex following the source.In this article,we discuss the specifications and design of an appropriate LIS assuming two major types of the accelerators:radio frequency(RF)high quality factor cavity type and non-resonant induction core type.We believe that a properly designed LIS would satisfy the requirements of both types,while some issues need to be verified experimentally. 展开更多
关键词 Inertial fusion ACCELERATOR ion source Laser ablation Heavy ion source
在线阅读 下载PDF
R&D progress of high power ion source on EAST-NBI 被引量:4
15
作者 谢亚红 胡纯栋 +8 位作者 刘胜 谢远来 许永建 梁立振 蒋才超 盛鹏 顾玉明 李军 刘智民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第1期158-161,共4页
The neutral beam injector (NBI) system was designed and developed mainly for the plasma heating on the Experimental Advanced Superconducting Tokamak (EAST). The high power ion source is the key part of the NBI. A ... The neutral beam injector (NBI) system was designed and developed mainly for the plasma heating on the Experimental Advanced Superconducting Tokamak (EAST). The high power ion source is the key part of the NBI. A hot cathode ion source was used on the EAST-NBI. The ion source was conditioned on the ion source test bed with hydrogen gas and achieved the designed parameters. The deuterium gas was used when it moved to the EAST-NBI. The main performance of the ion source on EAST is presented in this paper. The highest beam power of 4.5 MW in NBI-1 and 2.75 MW in NBI-2 was achieved. The total neutral beam power is about 4.5 MW. The long pulse beam of 100 s is injected into the EAST plasma too. 展开更多
关键词 ion source neutral beam injector EAST toakmak
在线阅读 下载PDF
Hefei utility negative ions test equipment with RF source:commissioning and first results 被引量:3
16
作者 Jianglong WEI Yahong XIE +8 位作者 Caichao JIANG Lizhen LIANG Qinglong CUl Shiyong CHEN Yongjian XU Yan WANG Li ZHANG Yuanlai XIE Chundong HU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第12期125-131,共7页
In order to study the key technology and physics of RF driven negative ion source for neutral beam injector in China, the Hefei utility negative ions test equipment with RF source was developed at Institute of Plasma ... In order to study the key technology and physics of RF driven negative ion source for neutral beam injector in China, the Hefei utility negative ions test equipment with RF source was developed at Institute of Plasma Physics, Chinese Academy of Sciences(ASIPP). Its negative ion source can be equipped with single or double RF drivers. There is a plasma expansion chamber with depth of 19 mm and an enhanced filter field. A three electrodes negative ion accelerator was employed to extract and accelerate the negative ions, which are plasma grid,extraction grid and ground grid. And there are several diagnostic tools for the plasma and beam parameters measurement. The characteristics of plasma generation, negative ion production and extraction were studied on the test equipment. The negative ion beam was extracted from the RF driven negative ion source for the first time. The detailed structure and main results are presented in this article. 展开更多
关键词 neutral beam injection negative ion source CFETR negative ions extraction
在线阅读 下载PDF
Interaction between plasma and electromagnetic field in ion source of 10 cm ECR ion thruster 被引量:3
17
作者 Hao Mou Yi-Zhou Jin +2 位作者 Juan Yang Xu Xia Yu-Liang Fu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第7期404-412,共9页
Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal th... Through diagnosing the plasma density and calculating the intensity of microwave electric field,four 10 cm electron cyclotron resonance(ECR)ion sources with different magnetic field structures are studied to reveal the inside interaction between the plasma,magnetic field and microwave electric field.From the diagnosing result it can be found that the plasma density distribution is controlled by the plasma generation and electron loss volumes associated with the magnetic field and microwave power level.Based on the cold plasma hypothesis and diagnosing result,the microwave electric field intensity distribution in the plasma is calculated.The result shows that the plasma will significantly change the distribution of the microwave electric field intensity to form a bow shape.From the boundary region of the shape to the center,the electric field intensity varies from higher to lower and the diagnosed density inversely changes.If the bow and its inside lower electric field intensity region are close to the screen grid,the performance of ion beam extracting will be better.The study can provide useful information for the creating of 10 cm ECR ion source and understanding its mechanism. 展开更多
关键词 electron cyclotron resonance plasma plasma diagnosing ion source
原文传递
Diagnosing the Fine Structure of Electron Energy Within the ECRIT Ion Source 被引量:3
18
作者 金逸舟 杨涓 +2 位作者 汤明杰 罗立涛 冯冰冰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第7期744-750,共7页
The ion source of the electron cyclotron resonance ion thruster (ECRIT) extracts ions from its ECR plasma to generate thrust, and has the property of low gas consumption (2 seem, standard-state cubic centimeter per... The ion source of the electron cyclotron resonance ion thruster (ECRIT) extracts ions from its ECR plasma to generate thrust, and has the property of low gas consumption (2 seem, standard-state cubic centimeter per minute) and high durability. Due to the indispensable effects of the primary electron in gas discharge, it is important to experimentally clarify the electron energy structure within the ion source of the ECRIT through analyzing the electron energy distribution function (EEDF) of the plasma inside the thruster. In this article the Langmuir probe diagnosing method was used to diagnose the EEDF, from which the effective electron temperature, plasma density and the electron energy probability function (EEPF) were deduced. The experimental results show that the magnetic field influences the curves of EEDF and EEPF and make the effective plasma parameter nonuniform. The diagnosed electron temperature and density from sample points increased from 4 eV/2 ×10^16 m-3 to 10 eV/4×10^16 m-3 with increasing distances from both the axis and the screen grid of the ion source. Electron temperature and density peaking near the wall coincided with the discharge process. However, a double Maxwellian electron distribution was unexpectedly observed at the position near the axis of the ion source and about 30 mm from the screen grid. Besides, the double Maxwellian electron distribution was more likely to emerge at high power and a low gas flow rate. These phenomena were believed to relate to the arrangements of the gas inlets and the magnetic field where the double Maxwellian electron distribution exits. The results of this research may enhance the understanding of the plasma generation process in the ion source of this type and help to improve its performance. 展开更多
关键词 ion source plasma diagnostic electron energy distribution function
在线阅读 下载PDF
Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source 被引量:2
19
作者 关明智 胡强 +6 位作者 高配峰 王省哲 杨通军 吴巍 辛灿杰 吴北民 马力祯 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期135-139,共5页
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin... A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further 展开更多
关键词 of on IS as NBTI Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance ion source in for Cu
原文传递
Diagnosis of Hydrogen Plasma in a Miniature Penning Ion Source by Double Probes 被引量:2
20
作者 金大志 杨中海 +1 位作者 肖坤祥 戴晶怡 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期48-51,共4页
Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron dens... Parameters of hydrogen plasma in a miniature Penning discharge ion source, including the electron temperature and the electron density, were measured by using double probes. The results indicate that the electron density increases and the electron temperature decreases with the increase in gas pressure and the discharge current. The electron temperature is about 5 - 9 eV and the electron density is 6.0× 10^13 ~ 1.2 × 10^14 m^-3 while the discharge current is in a range of 50 - 120 μA. 展开更多
关键词 Penning discharge ion source hydrogen plasma DIAGNOSIS double probes
在线阅读 下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部