期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Case Study on Synchronous Construction Technology for Secondary Lining of Large-diameter Single track Shiel Shield-bored ored Tunnel
1
作者 WANG Zhenfei ZHAI Jinying(Translated) 《Chinese Railways》 2023年第2期29-34,共6页
The synchronous construction of the secondary lining during the boring of large-diameter shield faces challenges such as the design of the lining jumbo,the high requirements on the performance for the lining jumbo,the... The synchronous construction of the secondary lining during the boring of large-diameter shield faces challenges such as the design of the lining jumbo,the high requirements on the performance for the lining jumbo,the organization of the construction activities in the small and confined area,the horizontal transportation for shield boring and high safety management requirements.A super-long invert lining construction jumbo,as well as the matching California switch,is developed,which provides solution for the confliction between the invert lining construction and the horizontal transportation.The procedure and method for the synchronous operation of the shield boring and the secondary lining are developed by referring to the synchronous construction of the secondary lining during the boring of the TBMs in hard rocks.Due to the adoption of the synchronous operation of the shield boring and the secondary lining,the construction period is shortened and the construction cost is reduced.The paper can provide reference for the synchronous construction of the secondary lining in similar projects in the future. 展开更多
关键词 large-diameter shield-bored tunnel synchronous construction of secondary lining super-long invert lining construction jumbo California switch "arch+side wall"lining jumbo
原文传递
A G-band terahertz monolithic integrated amplifier in 0.5-μm InP double heterojunction bipolar transistor technology 被引量:2
2
作者 李欧鹏 张勇 +4 位作者 徐锐敏 程伟 王元 牛斌 陆海燕 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期448-452,共5页
Design and characterization of a G-band(140–220 GHz) terahertz monolithic integrated circuit(TMIC) amplifier in eight-stage common-emitter topology are performed based on the 0.5-μm In Ga As/In P double heteroju... Design and characterization of a G-band(140–220 GHz) terahertz monolithic integrated circuit(TMIC) amplifier in eight-stage common-emitter topology are performed based on the 0.5-μm In Ga As/In P double heterojunction bipolar transistor(DHBT). An inverted microstrip line is implemented to avoid a parasitic mode between the ground plane and the In P substrate. The on-wafer measurement results show that peak gains are 20 dB at 140 GHz and more than 15-dB gain at 140–190 GHz respectively. The saturation output powers are-2.688 dBm at 210 GHz and-2.88 dBm at 220 GHz,respectively. It is the first report on an amplifier operating at the G-band based on 0.5-μm InP DHBT technology. Compared with the hybrid integrated circuit of vacuum electronic devices, the monolithic integrated circuit has the advantage of reliability and consistency. This TMIC demonstrates the feasibility of the 0.5-μm InGaAs/InP DHBT amplifier in G-band frequencies applications. 展开更多
关键词 terahertz amplifier InP double heterojunction bipolar transistor inverted microstrip line monolithic integrated circuit
原文传递
A unified power electronic controller for wind driven grid connected wound rotor induction generator using line commutated inverter
3
作者 D. R. BINU BEN JOSE N. AMMASAI GOUNDEN Raavi SRI NAGA RAMESH 《Frontiers in Energy》 SCIE CSCD 2013年第1期39-48,共10页
The implementation of a simple power converter for a wound rotor induction generator employing a three phase diode bridge rectifier and a line commutated inverter in the rotor circuit for super synchronous speeds has ... The implementation of a simple power converter for a wound rotor induction generator employing a three phase diode bridge rectifier and a line commutated inverter in the rotor circuit for super synchronous speeds has been proposed. The detailed working of the system in power smoothing mode and maximum power point tracking mode is presented. The current flow in the rotor circuit is controlled (by controlling the firing angle of the line commutated inverter) for controlling the stator power in both the modes. An 8 bit PIC microcontroller has been programmed to vary the firing angle of the line commutated inverter. Experiments have been carried out on a 3- phase, 3.73 kW, 400V, 50Hz, 4-pole, 1500r/rain wound rotor induction generator and the results obtained with the generator supplying power in both the modes are furnished. The complete scheme has been modeled using MATLAB/SIMULINK blocks and a simulation study has been conducted. The experimental waveforms are compared with the simulation results and a very close agreement between them is observed. 展开更多
关键词 SMOOTHING line commutated inverter MPPT power wound rotor induction generator
原文传递