A jet inner-loop bioreactor (JIBR) was used to treat synthetic sanitary sewage with low, medium and high COD load. The experimental results show that it could meet discharge standard at 20\|30 min of HRT (hydraulic re...A jet inner-loop bioreactor (JIBR) was used to treat synthetic sanitary sewage with low, medium and high COD load. The experimental results show that it could meet discharge standard at 20\|30 min of HRT (hydraulic retention time) for low COD concentration and 60\|120 min of HRT for medium and high COD concentration. The maximal COD volume loading and COD sludge loading of 27 kg\5m -3 \5d -1 and 5 kg/d per kg MLSS were acheived respectively, that were 10\|20 times higher than those of traditional wastewater treatment processes. The BOD 5 removal efficiency was more than 90% and NH + 4 —N more than 85%. The study on the activity showed that the oxygen consumption rate of the activated sludge in the JIBR was 39.13 mg\5L -1 \5h -1 , which was 1.7 times higher than that of the SBR(Sequencing Batch Reactor) and the dominant bacteria in jet inner\|loop bioreactor was Pseudomonas species.展开更多
针对微特电机驱动控制系统中,双有源桥(dual active bridge,DAB)变换器在高频调制过程中易产生较大电流应力,导致器件温升高、寿命衰减及负载扰动下系统稳定性下降等问题,本文提出一种改进型双移相优化调制策略。该方法基于双有源桥拓扑...针对微特电机驱动控制系统中,双有源桥(dual active bridge,DAB)变换器在高频调制过程中易产生较大电流应力,导致器件温升高、寿命衰减及负载扰动下系统稳定性下降等问题,本文提出一种改进型双移相优化调制策略。该方法基于双有源桥拓扑,建立双移相调制下的功率传输模型与电流应力数学模型,采用拉格朗日乘数法求解最优移相比组合,并进一步推导多功率场景下的电流应力解析表达式;在控制器设计方面,引入电感电流内环补偿机制,提高系统对电机驱动过程中负载变化的动态响应能力。MATLAB/Simulink仿真结果表明,该方法在典型微特电机负载工况下能有效降低变换器的电流应力,缩短暂态响应时间,并改善输出电压纹波,对提升微特电机控制系统的稳态与暂态性能具有良好效果,为高效能电机驱动供电模块的优化设计提供理论依据。展开更多
文摘A jet inner-loop bioreactor (JIBR) was used to treat synthetic sanitary sewage with low, medium and high COD load. The experimental results show that it could meet discharge standard at 20\|30 min of HRT (hydraulic retention time) for low COD concentration and 60\|120 min of HRT for medium and high COD concentration. The maximal COD volume loading and COD sludge loading of 27 kg\5m -3 \5d -1 and 5 kg/d per kg MLSS were acheived respectively, that were 10\|20 times higher than those of traditional wastewater treatment processes. The BOD 5 removal efficiency was more than 90% and NH + 4 —N more than 85%. The study on the activity showed that the oxygen consumption rate of the activated sludge in the JIBR was 39.13 mg\5L -1 \5h -1 , which was 1.7 times higher than that of the SBR(Sequencing Batch Reactor) and the dominant bacteria in jet inner\|loop bioreactor was Pseudomonas species.
文摘针对微特电机驱动控制系统中,双有源桥(dual active bridge,DAB)变换器在高频调制过程中易产生较大电流应力,导致器件温升高、寿命衰减及负载扰动下系统稳定性下降等问题,本文提出一种改进型双移相优化调制策略。该方法基于双有源桥拓扑,建立双移相调制下的功率传输模型与电流应力数学模型,采用拉格朗日乘数法求解最优移相比组合,并进一步推导多功率场景下的电流应力解析表达式;在控制器设计方面,引入电感电流内环补偿机制,提高系统对电机驱动过程中负载变化的动态响应能力。MATLAB/Simulink仿真结果表明,该方法在典型微特电机负载工况下能有效降低变换器的电流应力,缩短暂态响应时间,并改善输出电压纹波,对提升微特电机控制系统的稳态与暂态性能具有良好效果,为高效能电机驱动供电模块的优化设计提供理论依据。