Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research...Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research interest due to their higher arsenic content,research on freshwater fish is limited due to the challenges in quantifying and identifying arsenic species present at trace levels.We describe here a sensitivemethod and its application to the quantification of arsenic species in freshwater fish.Arsenic species from fish tissues were extracted using a methanol/water mixture(1:1 vol.ratio)and ultrasound sonication.Anion-exchange high-performance liquid chromatography(HPLC)enabled separation of arsenobetaine(AsB),inorganic arsenite(iAs^(Ⅲ)),dimethylarsinic acid(DMA),monomethylarsonic acid(MMA),inorganic arsenate(iAs^(Ⅴ)),and three new arsenic species.Inductively coupled plasma mass spectrometry(ICPMS)provided highly sensitive and specific detection of arsenic.A limit of detection of 0.25μg/kg(wet weight fish tissue)was achieved for the five target arsenic species:AsB,iAs^(Ⅲ),DMA,MMA,and iAs^(Ⅴ).A series of experimentswere conducted to ensure the accuracy and validity of the analytical method.The method was successfully applied to the determination of arsenic species in lakewhitefish,northern pike,and walleye,with AsB,DMA,and iAs^(Ⅴ) being frequently detected.Three new arsenic species were detected,but their chromatographic retention times did not match with those of any available arsenic standards.Future research is necessary to elucidate the identity of these new arsenic species detected in freshwater fish.展开更多
This work continues the studies on searching for plasma media with the inverse electron energy distribution function(EEDF)and providing recommendations for setting up subsequent experiments.The inverse EEDF is a distr...This work continues the studies on searching for plasma media with the inverse electron energy distribution function(EEDF)and providing recommendations for setting up subsequent experiments.The inverse EEDF is a distribution function that increases with an increase in energy at zero electron energy.The inverse EEDF plays a central role in the problem of negative conductivity.Based on the previously obtained criterion for the formation of an inverse EEDF in a spatially inhomogeneous plasma,a heuristic method is proposed that allows one to avoid resource-intensive calculations for spatially two-dimensional(2D)kinetic modeling on a large array of different glow discharges.It is shown that the conditions for EEDF inversion can be realized in two-chamber discharge structures due to violating the known Boltzmann distribution for electron density.The theoretical conclusions are validated by numerical modeling of lowpressure two-chamber inductively-coupled plasma(ICP)discharges in the COMSOL Multiphysics environment.As a result,areas of conditions with inverse EEDF were found for subsequent detailed kinetic analysis and experimental studies.展开更多
Objective The macula lagena in birds is located at the apical end of the cochlea and contains many tiny otoliths. The macula lagena is innervated and has neural projections to the brainstem, but its physiological func...Objective The macula lagena in birds is located at the apical end of the cochlea and contains many tiny otoliths. The macula lagena is innervated and has neural projections to the brainstem, but its physiological function is still unclear. It remains disputable that it is because otoliths in the lagena are rich in elements Fe and Zn that birds can obtain geomagnetic information for homing. To clarify this issue, we carried out a study to determine whether or not otoliths in the lagena of homing pigeons are richer in magnetic elements than those in the saccule and the utricle. Methods The contents of ferromagnetic elements (Fe, Co, Ni) and other metal elements in lagenal otoliths of adult homing pigeons were precisely analyzed with inductively coupled plasma mass spectrometry (ICP-MS) of high sensitivity, and then they were compared with those in saccular and utricular otoliths (all the contents were normalized to Ca). Results In adult homing pigeons, the contents of ferromagnetic elements (Fe, Co, Ni) in lagenal otoliths were less than 0.7% (normalized to Ca element) and were the same order in magnitude as those in saccular and utricular otoliths. The content of Fe in lagenal otoliths was not significantly different from that in utricular otoliths and was even lower than that in saccular otoliths. The content of Co in lagenal otoliths was lower than that in saccular otoliths and higher than that in utricular otoliths. The content of Ni in lagenal otoliths was not significantly different from that in saccular otoliths and was higher than that in utricular otoliths. The contents of other metal elements Na, Mg, K, Al, Mn and Pb in lagenal otoliths were not significantly different from those in utricular and saccular otoliths. The contents of metal elements Zn, Ba and Cu in lagenal otoliths were lower than those in saccular otoliths. Conclusion The contents of magnetic elements in lagenal otoliths of homing pigeons are not much higher than those in utricular and saccular otoliths, which does not support the hypothesis that birds depend on high contents of Fe and Zn in lagenal otoliths for sensation of geomagnetic information. Similarities in morphology, element ingredient and element content between lagenal otoliths and utricular otoliths suggest that the two types of otolithic organs may play similar roles in sensing gravitational and acceleration signals.展开更多
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss...The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.展开更多
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ...A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
A study of Cl2/BCl3-based inductively coupled plasma (ICP) was conducted using thick photoresist mask for anisotropic etching of 50μm diameter holes in a GaAs wafer at a relatively high average etching rate for etc...A study of Cl2/BCl3-based inductively coupled plasma (ICP) was conducted using thick photoresist mask for anisotropic etching of 50μm diameter holes in a GaAs wafer at a relatively high average etching rate for etching depths of more than 150μm. Plasma etch characteristics with ICP process pressure and the percentage of BCI3 were studied in greater detail at a constant ICP coil/bias power. The measured peak-to-peak voltage as a function of pressure was used to estimate the minimum energy of the ions bombarding the substrate. The process pressure was found to have a substantial influence on the energy of heavy ions. Various ion species in plasma showed minimum energy variation from 1.85 eV to 7.5 eV in the pressure range of 20 mTorr to 50 mTorr. The effect of pressure and the percentage of BCl3 on the etching rate and surface smoothness of the bottom surface of the etched hole were studied for a fixed total flow rate. The etching rate was found to decrease with the percentage of BCl3, whereas the addition of BCl3 resulted in anisotropic holes with a smooth veil free bottom surface at a pressure of 30 mTorr and 42% BC13. In addition, variation of the etching yield with pressure and etching depth were also investigated.展开更多
Amorphous spherical silica powders were prepared by inductively coupled thermal plasma treatment at a radio frequency of 36.2 MHz. The effects of the added content of hydrogen and nitrogen into argon(serving as the sh...Amorphous spherical silica powders were prepared by inductively coupled thermal plasma treatment at a radio frequency of 36.2 MHz. The effects of the added content of hydrogen and nitrogen into argon(serving as the sheath gas), as well as the carrier gas flow rate, on the spheroidization rate of silica powders, were investigated. The prepared silica powders before and after plasma treatment were examined by scanning electron microscopy, X-ray diffraction, and laser granulometric analysis. Results indicated that the average size of the silica particles increased, and the transformation of crystals into the amorphous state occurred after plasma treatment. Discharge image processing was employed to analyze the effect of the plasma temperature field on the spheroidization rate. The spheroidization rate of the silica powder increased with the increase of the hydrogen content in the sheath gas. On the other hand, the spheroidization rate of the silica power first increased and then decreased with the increase of the nitrogen content in the sheath gas. Moreover, the amorphous content increased with the increase of the spheroidization rate of the silica powder.展开更多
CubeSats have attracted more research interest recently due to their lower cost and shorter production time.A promising technology for CubeSat application is atmosphere-breathing electric propulsion,which can capture ...CubeSats have attracted more research interest recently due to their lower cost and shorter production time.A promising technology for CubeSat application is atmosphere-breathing electric propulsion,which can capture the atmospheric particles as propulsion propellant to maintain longterm mission at very low Earth orbit.This paper designs an atmosphere-breathing electric propulsion system for a 3 U CubeSat,which consists of an intake device and an electric thruster based on the inductively coupled plasma.The capture performance of intake device is optimized considering both particles capture efficiency and compression ratio.The plasma source is also analyzed by experiment and simulation.Then,the thrust performance is also estimated when taking into account the intake performance.The results show that it is feasible to use atmosphere-breathing electric propulsion technology for CubeSats to compensate for aerodynamic drag at lower Earth orbit.展开更多
ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance ...ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance of ZrN films was investigated. When the ICP power is below 300 W, the ZrN films show a columnar structure. With the increase of ICP power, the texture coefficient (To) of the (111) plane, the nanohardness and elastic modulus of the films increase and reach the maximum at a power of 300 W. As the ICP Power exceeds 300 W, the films exhibit a ZrN and ZrNx mixed crystal structure without columnar grain while the nanohardness and elastic modulus of the films decrease. All the ZrN coated samples show a higher corrosion resistance than that of the bare M2 steel substrate in 3.5% NaCl electrolyte. The nanohardness and elastic modulus mostly depend on the crystalline structure and Tc of ZrN(111).展开更多
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with...The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.展开更多
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements...A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.展开更多
The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these pa...The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these parameters were determined by the "trial and error" method, resulting in wastes of time and funds. In this paper, a new approach of regression orthogonal design with plasma simulation experiments is proposed to investigate the sensitivity of the structural parameters on the uniformity of plasma characteristics. The tool for simulating plasma is CFD-ACE+, which is commercial multi-physical modeling software that has been proven to be accurate for plasma simulation. The simulated experimental results are analyzed to get a regression equation on three structural parameters. Through this equation, engineers can compute the uniformity of the electron number density rapidly without modeling by CFD-ACE+. An optimization performed at the end produces good results.展开更多
An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in e...An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2504, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001-0.169 gg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method.展开更多
The ion density distribution in the reaction chamber was diagnosed by a Langmuir probe. The rules of the ion density distribution were obtained under the pressures of 9 Pa, 13 Pa, 27 Pa and 53 Pa in the reaction chamb...The ion density distribution in the reaction chamber was diagnosed by a Langmuir probe. The rules of the ion density distribution were obtained under the pressures of 9 Pa, 13 Pa, 27 Pa and 53 Pa in the reaction chamber, different radio-frequency powers and different positions. The result indicates that the ion density decreases as the pressure increases, and increases as the power decreases. The ion density of axial position z =0 achieves 5.8×1010 on the center of coil under the power of 200 w and pressure of 9 Pa in the reaction chamber.展开更多
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ...An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.展开更多
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud...An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.展开更多
In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte...In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods.展开更多
An investigation was made into polystyrene (PS) grafted onto nanometre silicon carbide (SIC) particles. In our experiment, the grafting polymerization reaction was induced by a radio frequency (RF) inductively c...An investigation was made into polystyrene (PS) grafted onto nanometre silicon carbide (SIC) particles. In our experiment, the grafting polymerization reaction was induced by a radio frequency (RF) inductively coupled plasma (ICP) treatment of the nanometre powder. FTIR (Fourier transform infrared spectrum) and XPS (X-ray photoelectron spectroscopy) results reveal that PS is grafted onto the surface of silicon carbide powder. An analysis is presented on the effectiveness of this approach as a function of plasma operating variables including the plasma treating power, treating time, and grafting reaction temperature and time.展开更多
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter...The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented.展开更多
An innovative application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) technique in illustrating elemental distributions on stainless steel sheets was presented. The technique proved to...An innovative application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) technique in illustrating elemental distributions on stainless steel sheets was presented. The technique proved to be a systematic and accurate ap- proach in producing visual images or maps of elemental distributions at cross-sectional surface of a stainless steel sheet. Two stain- less steel sheets served as research objects: 3 mm×l 300 mm hot-rolled stainless steel plate and 1 mm×l 260 mm cold-rolled plate. The cross-sectional surfaces of the two samples at 1/4 position along the width direction were scanned (raster area -44 mm2 and 11 mm2) with a focused laser beam (wavelength 213 nm, diameter of laser crater 100 μm, and laser power 1.6 mJ) in a laser abla- tion chamber. The laser ablation system was coupled to a quadrupole ICP-MS, which made the detection of ion intensities of 27A1+, 44Ca+, 47Ti-, 55Mn+ and 56Fe+ within an area of interest possible. One-dimensional (ID) content line distribution maps and two- dimensional (2D) contour maps for specific positions or areas were plotted to indicate the element distribution of a target area with high accuracy. Statistic method was used to analyze the acquired data by calculating median contents, maximum segregation, sta- tistic segregation and content-frequency distribution.展开更多
基金supported by Alberta Health,Alberta Innovates,the Canada Research Chairs Program,the Canadian Institutes of Health Research,and the Natural Sciences and Engineering Research Council of Canada。
文摘Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research interest due to their higher arsenic content,research on freshwater fish is limited due to the challenges in quantifying and identifying arsenic species present at trace levels.We describe here a sensitivemethod and its application to the quantification of arsenic species in freshwater fish.Arsenic species from fish tissues were extracted using a methanol/water mixture(1:1 vol.ratio)and ultrasound sonication.Anion-exchange high-performance liquid chromatography(HPLC)enabled separation of arsenobetaine(AsB),inorganic arsenite(iAs^(Ⅲ)),dimethylarsinic acid(DMA),monomethylarsonic acid(MMA),inorganic arsenate(iAs^(Ⅴ)),and three new arsenic species.Inductively coupled plasma mass spectrometry(ICPMS)provided highly sensitive and specific detection of arsenic.A limit of detection of 0.25μg/kg(wet weight fish tissue)was achieved for the five target arsenic species:AsB,iAs^(Ⅲ),DMA,MMA,and iAs^(Ⅴ).A series of experimentswere conducted to ensure the accuracy and validity of the analytical method.The method was successfully applied to the determination of arsenic species in lakewhitefish,northern pike,and walleye,with AsB,DMA,and iAs^(Ⅴ) being frequently detected.Three new arsenic species were detected,but their chromatographic retention times did not match with those of any available arsenic standards.Future research is necessary to elucidate the identity of these new arsenic species detected in freshwater fish.
基金supported by the National Key R&D Program of China(No.2022YFE0204100)National Natural Science Foundation of China(Nos.12205067 and 12375199)the Fundamental Research Funds for the Central University(No.HIT.D?J.2023178)。
文摘This work continues the studies on searching for plasma media with the inverse electron energy distribution function(EEDF)and providing recommendations for setting up subsequent experiments.The inverse EEDF is a distribution function that increases with an increase in energy at zero electron energy.The inverse EEDF plays a central role in the problem of negative conductivity.Based on the previously obtained criterion for the formation of an inverse EEDF in a spatially inhomogeneous plasma,a heuristic method is proposed that allows one to avoid resource-intensive calculations for spatially two-dimensional(2D)kinetic modeling on a large array of different glow discharges.It is shown that the conditions for EEDF inversion can be realized in two-chamber discharge structures due to violating the known Boltzmann distribution for electron density.The theoretical conclusions are validated by numerical modeling of lowpressure two-chamber inductively-coupled plasma(ICP)discharges in the COMSOL Multiphysics environment.As a result,areas of conditions with inverse EEDF were found for subsequent detailed kinetic analysis and experimental studies.
基金supported by the National Natural Science Foundation of China(No.30470560 and 30730041)the National Basic Research Program of China (No.2007CB512306)the Knowledge Innovation Project of Chinese Academy of Sciences (No.KSCX1-YW-R-36)
文摘Objective The macula lagena in birds is located at the apical end of the cochlea and contains many tiny otoliths. The macula lagena is innervated and has neural projections to the brainstem, but its physiological function is still unclear. It remains disputable that it is because otoliths in the lagena are rich in elements Fe and Zn that birds can obtain geomagnetic information for homing. To clarify this issue, we carried out a study to determine whether or not otoliths in the lagena of homing pigeons are richer in magnetic elements than those in the saccule and the utricle. Methods The contents of ferromagnetic elements (Fe, Co, Ni) and other metal elements in lagenal otoliths of adult homing pigeons were precisely analyzed with inductively coupled plasma mass spectrometry (ICP-MS) of high sensitivity, and then they were compared with those in saccular and utricular otoliths (all the contents were normalized to Ca). Results In adult homing pigeons, the contents of ferromagnetic elements (Fe, Co, Ni) in lagenal otoliths were less than 0.7% (normalized to Ca element) and were the same order in magnitude as those in saccular and utricular otoliths. The content of Fe in lagenal otoliths was not significantly different from that in utricular otoliths and was even lower than that in saccular otoliths. The content of Co in lagenal otoliths was lower than that in saccular otoliths and higher than that in utricular otoliths. The content of Ni in lagenal otoliths was not significantly different from that in saccular otoliths and was higher than that in utricular otoliths. The contents of other metal elements Na, Mg, K, Al, Mn and Pb in lagenal otoliths were not significantly different from those in utricular and saccular otoliths. The contents of metal elements Zn, Ba and Cu in lagenal otoliths were lower than those in saccular otoliths. Conclusion The contents of magnetic elements in lagenal otoliths of homing pigeons are not much higher than those in utricular and saccular otoliths, which does not support the hypothesis that birds depend on high contents of Fe and Zn in lagenal otoliths for sensation of geomagnetic information. Similarities in morphology, element ingredient and element content between lagenal otoliths and utricular otoliths suggest that the two types of otolithic organs may play similar roles in sensing gravitational and acceleration signals.
基金Project(21075138) supported by the National Natural Science Foundation of ChinaProject(cstc2011jjA0780) supported by Natural Science Foundation of Chongqing City,ChinaProject(KJ121311) supported by Educational Commission of Chongqing City of China
文摘The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.
基金the Natural Science Foundation of Hunan Province, China (No. 05JJ40017).
文摘A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results.
文摘A study of Cl2/BCl3-based inductively coupled plasma (ICP) was conducted using thick photoresist mask for anisotropic etching of 50μm diameter holes in a GaAs wafer at a relatively high average etching rate for etching depths of more than 150μm. Plasma etch characteristics with ICP process pressure and the percentage of BCI3 were studied in greater detail at a constant ICP coil/bias power. The measured peak-to-peak voltage as a function of pressure was used to estimate the minimum energy of the ions bombarding the substrate. The process pressure was found to have a substantial influence on the energy of heavy ions. Various ion species in plasma showed minimum energy variation from 1.85 eV to 7.5 eV in the pressure range of 20 mTorr to 50 mTorr. The effect of pressure and the percentage of BCl3 on the etching rate and surface smoothness of the bottom surface of the etched hole were studied for a fixed total flow rate. The etching rate was found to decrease with the percentage of BCl3, whereas the addition of BCl3 resulted in anisotropic holes with a smooth veil free bottom surface at a pressure of 30 mTorr and 42% BC13. In addition, variation of the etching yield with pressure and etching depth were also investigated.
基金financially supported by the National Natural Science Foundation of China (Nos. 21377133, 11535003, and 11405221)
文摘Amorphous spherical silica powders were prepared by inductively coupled thermal plasma treatment at a radio frequency of 36.2 MHz. The effects of the added content of hydrogen and nitrogen into argon(serving as the sheath gas), as well as the carrier gas flow rate, on the spheroidization rate of silica powders, were investigated. The prepared silica powders before and after plasma treatment were examined by scanning electron microscopy, X-ray diffraction, and laser granulometric analysis. Results indicated that the average size of the silica particles increased, and the transformation of crystals into the amorphous state occurred after plasma treatment. Discharge image processing was employed to analyze the effect of the plasma temperature field on the spheroidization rate. The spheroidization rate of the silica powder increased with the increase of the hydrogen content in the sheath gas. On the other hand, the spheroidization rate of the silica power first increased and then decreased with the increase of the nitrogen content in the sheath gas. Moreover, the amorphous content increased with the increase of the spheroidization rate of the silica powder.
基金funded by the National Natural Science Foundation of China (No. T2221002)
文摘CubeSats have attracted more research interest recently due to their lower cost and shorter production time.A promising technology for CubeSat application is atmosphere-breathing electric propulsion,which can capture the atmospheric particles as propulsion propellant to maintain longterm mission at very low Earth orbit.This paper designs an atmosphere-breathing electric propulsion system for a 3 U CubeSat,which consists of an intake device and an electric thruster based on the inductively coupled plasma.The capture performance of intake device is optimized considering both particles capture efficiency and compression ratio.The plasma source is also analyzed by experiment and simulation.Then,the thrust performance is also estimated when taking into account the intake performance.The results show that it is feasible to use atmosphere-breathing electric propulsion technology for CubeSats to compensate for aerodynamic drag at lower Earth orbit.
文摘ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance of ZrN films was investigated. When the ICP power is below 300 W, the ZrN films show a columnar structure. With the increase of ICP power, the texture coefficient (To) of the (111) plane, the nanohardness and elastic modulus of the films increase and reach the maximum at a power of 300 W. As the ICP Power exceeds 300 W, the films exhibit a ZrN and ZrNx mixed crystal structure without columnar grain while the nanohardness and elastic modulus of the films decrease. All the ZrN coated samples show a higher corrosion resistance than that of the bare M2 steel substrate in 3.5% NaCl electrolyte. The nanohardness and elastic modulus mostly depend on the crystalline structure and Tc of ZrN(111).
基金Project (04JJ40016) supported by the Natural Science Foundation of Hunan Province, China
文摘The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%.
文摘A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%.
基金supported by Important National Science & Technology Specific Projects of China (No.2) (Nos.2009ZX02001,2011ZX02403)
文摘The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these parameters were determined by the "trial and error" method, resulting in wastes of time and funds. In this paper, a new approach of regression orthogonal design with plasma simulation experiments is proposed to investigate the sensitivity of the structural parameters on the uniformity of plasma characteristics. The tool for simulating plasma is CFD-ACE+, which is commercial multi-physical modeling software that has been proven to be accurate for plasma simulation. The simulated experimental results are analyzed to get a regression equation on three structural parameters. Through this equation, engineers can compute the uniformity of the electron number density rapidly without modeling by CFD-ACE+. An optimization performed at the end produces good results.
基金Project(21075138)supported by the National Natural Science Foundation of ChinaProject(cstc2013jcyjA10088)supported by Chongqing Natural Science Foundation,ChinaProject(KJ121311)supported by Scientific and Technological Research Program of Chongqing Municipal Education Commission,China
文摘An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2504, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001-0.169 gg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method.
基金The project supported by the Natural Science Foundation of Guangdong province (No. 000675) the Key project tackled of Guangdong province (ZKM01401G)
文摘The ion density distribution in the reaction chamber was diagnosed by a Langmuir probe. The rules of the ion density distribution were obtained under the pressures of 9 Pa, 13 Pa, 27 Pa and 53 Pa in the reaction chamber, different radio-frequency powers and different positions. The result indicates that the ion density decreases as the pressure increases, and increases as the power decreases. The ion density of axial position z =0 achieves 5.8×1010 on the center of coil under the power of 200 w and pressure of 9 Pa in the reaction chamber.
基金supported by the Natural Science Foundation of Hunan Province(No.05JJ40017)Education Department of Hunan Province(No.05B064).
文摘An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results.
基金The China Ocean Mineral Resources Research and Development Association Research Program of the State Oceanic Administration of China under contract No.DY125-13-R-07the National Natural Science Foundation of China under contract Nos 41322036 and 41230960+1 种基金the Shandong Provincial Natural Science Foundation of China under contract No.ZR2014DP009the Special Basic Research Funds for Central Public Research Institutes for The First Institute of Oceanography,State Oceanic Administration of China under contract Nos GY0213G06 and GY02-2012G35
文摘An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples.
文摘In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods.
文摘An investigation was made into polystyrene (PS) grafted onto nanometre silicon carbide (SIC) particles. In our experiment, the grafting polymerization reaction was induced by a radio frequency (RF) inductively coupled plasma (ICP) treatment of the nanometre powder. FTIR (Fourier transform infrared spectrum) and XPS (X-ray photoelectron spectroscopy) results reveal that PS is grafted onto the surface of silicon carbide powder. An analysis is presented on the effectiveness of this approach as a function of plasma operating variables including the plasma treating power, treating time, and grafting reaction temperature and time.
文摘The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented.
基金Sponsored by National Major Instrument and Equipment Development Special Project of China(2011YQ14014710)
文摘An innovative application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) technique in illustrating elemental distributions on stainless steel sheets was presented. The technique proved to be a systematic and accurate ap- proach in producing visual images or maps of elemental distributions at cross-sectional surface of a stainless steel sheet. Two stain- less steel sheets served as research objects: 3 mm×l 300 mm hot-rolled stainless steel plate and 1 mm×l 260 mm cold-rolled plate. The cross-sectional surfaces of the two samples at 1/4 position along the width direction were scanned (raster area -44 mm2 and 11 mm2) with a focused laser beam (wavelength 213 nm, diameter of laser crater 100 μm, and laser power 1.6 mJ) in a laser abla- tion chamber. The laser ablation system was coupled to a quadrupole ICP-MS, which made the detection of ion intensities of 27A1+, 44Ca+, 47Ti-, 55Mn+ and 56Fe+ within an area of interest possible. One-dimensional (ID) content line distribution maps and two- dimensional (2D) contour maps for specific positions or areas were plotted to indicate the element distribution of a target area with high accuracy. Statistic method was used to analyze the acquired data by calculating median contents, maximum segregation, sta- tistic segregation and content-frequency distribution.