The flow and heat transfer of air-cooled heat exchangers play important roles in the performance of indirect dry cooling systems in power plants,so it is of benefit to the design and operation of a typical indirect dr...The flow and heat transfer of air-cooled heat exchangers play important roles in the performance of indirect dry cooling systems in power plants,so it is of benefit to the design and operation of a typical indirect dry cooling system to optimize the thermo-flow characteristics of air-cooled heat exchangers.The entransy dissipation method is applied to the performance optimization of air-cooled heat exchangers in this paper.Two irreversible heat transfer processes in air-cooled heat exchangers,the heat transfer between circulating water and cooling air and the mixing of circulating water,are taken into account and analyzed by means of the entransy dissipation method.The total entransy dissipation rate,which connects the geometrical parameters of air-cooled heat exchanger sectors and the heat capacity rates of the fluids to the heat flow rate in every sector,is obtained.Based on the mathematical relation and the conditional extremum method,an optimization equation group is derived,by which the air-cooled heat exchanger with known air-side parameters is optimized,showing that the entransy dissipation based optimization approach can contribute to the distribution optimization of circulating water in air-cooled heat exchangers of a typical indirect dry cooling system.展开更多
The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchang...The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchanger model was adopted to simulate the heat exchange between circulating water and ambient air.The performances of natural draft dry cooling system(NDDCS)with and without exterior windbreakers were numerically studied.The pressure,velocity and temperature distribution of cooling air in wind angles of 0°,45°and 90°was obtained and presented.The results show that in all wind directions,the performances for lateral sector of towers with windbreakers are significantly improved,but the low-pressure zone appears unexpectedly for the rear sectors,which reduces the air flow rate.The cooling performances of the twin towers with or without windbreakers decrease at first but then recover with the wind velocity increasing.Besides,the optimal flow and heat transfer performances appear in the wind angle of 0°.The cooling performances can be significantly improved in all three wind directions due to windbreaker configuration.展开更多
A mixed-mode forced-convection solar dryer(MMFCSD)is a device that utilizes both direct and indirect solar energy.The solar col-lector,which stores thermal energy for indirect solar uses,is an essential component of t...A mixed-mode forced-convection solar dryer(MMFCSD)is a device that utilizes both direct and indirect solar energy.The solar col-lector,which stores thermal energy for indirect solar uses,is an essential component of the dryer.Unfortunately,the thermal effi-ciency of this device is generally low.In this study,a technique was employed to improve the heat transfer of the solar collector in a MMFCSD.The technique involved adjusting the air flow pattern into a swirling flow to disturb the thermal boundary layer on the absorber plate under forced convection by using stainless wire mesh.The experiment was conducted under actual conditions and bananas were used as the drying sample.The experimental results of the thermal efficiency of the solar collector(ƞ_(solar))and the drying efficiency(ƞ_(drying))are presented.The results indicated that the air outlet temperature andƞsolar of the solar collector with stainless wire mesh were higher than the case without stainless wire mesh,reaching a maximum temperature of 46.22°C and 37.97°C,and average ƞ_(solar) of 0.26±0.02 and 0.14±0.01,respectively.The MMFCSD with stainless wire mesh had a higher ƞ_(drying) than the case without stain-less wire mesh,with values of 0.048±0.004 and 0.039±0.003,respectively,resulting in an~23.07%increase.This was attributed to the air swirling flow through the stainless wire mesh and the heat accumulation in the drying chamber,which led to an increase in the drying chamber temperature from 54.03°C to 63.60°C,an increase in the effective moisture diffusivity from 7.28×10^(-7) to 1.19×10^(-6) m^(2)/s and a decrease in the drying time of 5 h 30 min.However,further research is needed to investigate the quality of the dried sam-ples and their economic value.展开更多
基金National Natural Science Foundation of China and Shenhua Group Corporation Limited(Grant No.U1261108)The Science and Technology Program of China Huaneng Group(Grant No.HNKJ13-H09)
文摘The flow and heat transfer of air-cooled heat exchangers play important roles in the performance of indirect dry cooling systems in power plants,so it is of benefit to the design and operation of a typical indirect dry cooling system to optimize the thermo-flow characteristics of air-cooled heat exchangers.The entransy dissipation method is applied to the performance optimization of air-cooled heat exchangers in this paper.Two irreversible heat transfer processes in air-cooled heat exchangers,the heat transfer between circulating water and cooling air and the mixing of circulating water,are taken into account and analyzed by means of the entransy dissipation method.The total entransy dissipation rate,which connects the geometrical parameters of air-cooled heat exchanger sectors and the heat capacity rates of the fluids to the heat flow rate in every sector,is obtained.Based on the mathematical relation and the conditional extremum method,an optimization equation group is derived,by which the air-cooled heat exchanger with known air-side parameters is optimized,showing that the entransy dissipation based optimization approach can contribute to the distribution optimization of circulating water in air-cooled heat exchangers of a typical indirect dry cooling system.
基金The financial supports for this research,from the National Basic Research Program of China(Grant No.2015CB251503)Central University Fundation of China(Grant No.JB2018130)。
文摘The winds will greatly weaken the cooling performance of indirect dry cooling system with twin towers.The exterior windbreakers are recommended to restrain the wind adverse effects in this paper.The macro heat exchanger model was adopted to simulate the heat exchange between circulating water and ambient air.The performances of natural draft dry cooling system(NDDCS)with and without exterior windbreakers were numerically studied.The pressure,velocity and temperature distribution of cooling air in wind angles of 0°,45°and 90°was obtained and presented.The results show that in all wind directions,the performances for lateral sector of towers with windbreakers are significantly improved,but the low-pressure zone appears unexpectedly for the rear sectors,which reduces the air flow rate.The cooling performances of the twin towers with or without windbreakers decrease at first but then recover with the wind velocity increasing.Besides,the optimal flow and heat transfer performances appear in the wind angle of 0°.The cooling performances can be significantly improved in all three wind directions due to windbreaker configuration.
基金This research project is supported by the Science Research and Innovation Fund(contract no.FF66-P1-134).We would like to thank the Development in Technology of Porous Material Research Laboratory(DiTo-Lab),Department of Mechanical Engineering,Faculty of Engineering and Technology,Rajamangala University of Technology Isan for support and permission to use the place for the research and also thank Mr Bancha Chapakdee and Mr Sila Boonsitoum,an undergraduate student of the Department of Mechanical Engineering,for collection of experimental results.
文摘A mixed-mode forced-convection solar dryer(MMFCSD)is a device that utilizes both direct and indirect solar energy.The solar col-lector,which stores thermal energy for indirect solar uses,is an essential component of the dryer.Unfortunately,the thermal effi-ciency of this device is generally low.In this study,a technique was employed to improve the heat transfer of the solar collector in a MMFCSD.The technique involved adjusting the air flow pattern into a swirling flow to disturb the thermal boundary layer on the absorber plate under forced convection by using stainless wire mesh.The experiment was conducted under actual conditions and bananas were used as the drying sample.The experimental results of the thermal efficiency of the solar collector(ƞ_(solar))and the drying efficiency(ƞ_(drying))are presented.The results indicated that the air outlet temperature andƞsolar of the solar collector with stainless wire mesh were higher than the case without stainless wire mesh,reaching a maximum temperature of 46.22°C and 37.97°C,and average ƞ_(solar) of 0.26±0.02 and 0.14±0.01,respectively.The MMFCSD with stainless wire mesh had a higher ƞ_(drying) than the case without stain-less wire mesh,with values of 0.048±0.004 and 0.039±0.003,respectively,resulting in an~23.07%increase.This was attributed to the air swirling flow through the stainless wire mesh and the heat accumulation in the drying chamber,which led to an increase in the drying chamber temperature from 54.03°C to 63.60°C,an increase in the effective moisture diffusivity from 7.28×10^(-7) to 1.19×10^(-6) m^(2)/s and a decrease in the drying time of 5 h 30 min.However,further research is needed to investigate the quality of the dried sam-ples and their economic value.