期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Visual evoked potential by implanted scalp electrode in rats
1
作者 Qun Guo,Bei Xie,Yong-Hao Gu,Jing An,Feng Xia,Zuo-Ming Zhang Department of Clinical Aerospace Medicine,Faculty of Aerospace Medicine,the Fourth Military Medical University,Xi’an 710032,Shaanxi Province,China 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第2期220-220,共1页
·AIM:To establish a new method to record visual evoked potential of rats and this method was applied to retinal cone degeneration (RCD) and congenital stationary night blindness (CSNB) rats to see whether it is f... ·AIM:To establish a new method to record visual evoked potential of rats and this method was applied to retinal cone degeneration (RCD) and congenital stationary night blindness (CSNB) rats to see whether it is feasible.·METHODS:After anesthesia,the rats scalp surface was exposed and two stainless screws were implanted at 4mm in front of and 8mm behind Bregma.The front one was reference electrode and the latter one was recording electrode.The ground electrode was joined to the tail.And we recorded VEP of scotopic adaptation and photopic adaptation (The stimulus intensity of light :0.011,0.035,0.11,0.35,1.1 and 3.5cd·s/m2.They were all overlapped for 100 times.There were 2-5minutes intervals between different intensities.The frequency of stimulation was 1Hz and time course was 300 milliseconds).A week later,we recorded the VEP again in the same conditions.·RESULTS:The rats who were implanted with electrodes could live longer.When they were recorded,there was no disturbance and the waveforms were very clear and steady.There was no difference between the waveforms recorded by conventional method and those by implanted electrodes while the amplitude of new method was larger than conventional.We could get the same conclusion in RCD and CSNB rats.·CONCLUSION:Since the electrodes can be kept on the scalp for a longer time,we can not only observe dynamic changes of VEP but also observe the long-duration patho-logical changes in the rats.Because the positions of recording and reference electrodes were fixed,the system error can be reduced and the repeatability of experiments increased.· 展开更多
关键词 visual evoked potential implanted scalp electrode RATS
原文传递
Electrochemical Behavior of Adriamycin at Ni/GC Ion Implantation Modified Electrode
2
作者 Jing Bo HU Qi Long LI(Department of Chemistry, Beijing Normal University, Bejing 100875) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第7期601-602,共2页
With a Ni/GC ion implantation modified electrode as working electrode, in 0.1 mol/L HOAc-NaOAc (pH=4.62) solution, a sensitive reductive wave of ADM was obtained by linear sweep voltammetry. The peak potential was -0.... With a Ni/GC ion implantation modified electrode as working electrode, in 0.1 mol/L HOAc-NaOAc (pH=4.62) solution, a sensitive reductive wave of ADM was obtained by linear sweep voltammetry. The peak potential was -0.55 V (vs.SCE). The peak current is proportional to the concentration of ADM with a detection limit of 6.9 X 10(-8) mol/L. The behavior of the reduction wave was studied. The experiments of AES and XPS showed that Ni was surely implanted into the surface of the GCE and the implanted Ni at the GCE improved the electrocatalytic activity. 展开更多
关键词 ion implantation modified electrode electrochemical behavior ADRIAMYCIN
在线阅读 下载PDF
Studies on the Electrochemical Behavior of Bleomycin at a Co/GC Ion Implantation Modified Electrode and Its Application
3
作者 HU Jing-bo LI Qi-long 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2001年第4期362-367,共6页
In a 0. 10 mol/L HAc-NaAc buffer solution (pH = 4. 59), a sensitive reduction peak of bleomycin was observed by linear sweep voltammetry at a Co/GC ion implantation modified electrode. The peak potential was-0. 73 V(i... In a 0. 10 mol/L HAc-NaAc buffer solution (pH = 4. 59), a sensitive reduction peak of bleomycin was observed by linear sweep voltammetry at a Co/GC ion implantation modified electrode. The peak potential was-0. 73 V(iw. SCE). The peak current was proportional to the concentration of bleomycin over the range of 5.0 × 10-8-1.0× 10-6 and 1.0× 10-6-1. 0 × 10-5 mol/L with a detection limit of 2.0 × 10-8 mol/L. The electrochemical behavior of the reduction peak of bleomycin at the Co/GC modified electrode was studied by linear sweep and cyclic voltammetry and applied to the determination of bleomycin in urine. This method is simple, rapid and reliable. The reduction process is quasi-reversible. The experiments of AES and XPS showed that Co was surely implanted into the surface of GCE and the depth distribution of Co was in good agreement with Gooses normal distribution; the implanted Co at GCE improved the electrocatalytic activity. 展开更多
关键词 Co/GC ion implantation modified electrode Electrochemical behavior Linear sweep voltammetry BLEOMYCIN
在线阅读 下载PDF
Nerve function restoration following targeted muscle reinnervation after varying delayed periods
4
作者 Yuanheng Li Jiangping Huang +4 位作者 Yuling Chen Shanshan Zhu Zhen Huang Lin Yang Guanglin Li 《Neural Regeneration Research》 SCIE CAS CSCD 2023年第12期2762-2766,共5页
Targeted muscle reinnervation has been proposed for reconstruction of neuromuscular function in amputees.However,it is unknown whether performing delayed targeted muscle reinnervation after nerve injury will affect re... Targeted muscle reinnervation has been proposed for reconstruction of neuromuscular function in amputees.However,it is unknown whether performing delayed targeted muscle reinnervation after nerve injury will affect restoration of function.In this rat nerve injury study,the median and musculocutaneous nerves of the forelimb were transected.The proximal median nerve stump was sutured to the distal musculocutaneous nerve stump immediately and 2 and 4 weeks after surgery to reinnervate the biceps brachii.After targeted muscle reinnervation,intramuscular myoelectric signals from the biceps brachii were recorded.Signal amplitude gradually increased with time.Biceps brachii myoelectric signals and muscle fiber morphology and grooming behavior did not significantly differ among rats subjected to delayed target muscle innervation for different periods.Targeted muscle reinnervation delayed for 4 weeks can acquire the same nerve function restoration effect as that of immediate reinnervation. 展开更多
关键词 biceps brachii delayed nerve repair delayed targeted muscle reinnervation functional reconstruction grooming test implanted electrode intramuscular myoelectric signals median nerve motor function nerve transfer
暂未订购
A Miniaturized System for Neural Signal Acquiring and Processing 被引量:1
5
作者 WANG Min GAO Guang-hong +4 位作者 XIANG Dong-sheng CAO Mao-yong JIA Ai-bin DING Lei KONG Hui-min 《Chinese Journal of Biomedical Engineering(English Edition)》 2008年第3期114-119,共6页
To collect neural activity data from awake, behaving freely animals, we develop miniaturized implantable recording system by the modem chip:Programmable System on Chip (PSoC) and through chronic electrodes in the c... To collect neural activity data from awake, behaving freely animals, we develop miniaturized implantable recording system by the modem chip:Programmable System on Chip (PSoC) and through chronic electrodes in the cortex. With PSoC family member CY8C29466,the system completed operational and instrument amplifiers, filters, timers, AD convertors, and serial communication, etc. The signal processing was dealt with virtual instrument technology. All of these factors can significantly affect the price and development cycle of the project. The result showed that the system was able to record and analyze neural extrocellular discharge generated by neurons continuously for a week or more. This is very useful for the interdisciplinary research of neuroscience and information engineering technique. The circuits and architecture of the devices can be adapted for neurobiology and research with other small animals. 展开更多
关键词 Programmable System on Chip implanting electrodes neural signal virtual instrument wavelet transform
暂未订购
A Radio Communication System for Neuronal Signals
6
作者 Wang Min Yang Maoquan +2 位作者 Wang Xiaojun Guang Kui Zhang Xiao 《Chinese Journal of Population,Resources and Environment》 2012年第3期125-128,共4页
To collect neuronal activity data from awake, freely behaving animals, we developed miniature telemetry recording system. The integrated system consists of four major components: l) Microelectrodes and micro-driver ... To collect neuronal activity data from awake, freely behaving animals, we developed miniature telemetry recording system. The integrated system consists of four major components: l) Microelectrodes and micro-driver assembly, 2) analog front end (AFE), 3) programmable system on chip (PSoC), and 4) ra- dio transceiver and the LabVIEW were used as a platform for the graphic user interface. The result showed the system was able to record and analyze neuronal recordings in freely moving animals and lasted continuously for a time period of a week or more. This is very useful for the study of the interdisciplinary research of neu- roscience and information engineering techniques. The circuits and architecture of the devices can be adapted for neurobiology and research with other small animals. 展开更多
关键词 brain computer interface implanting electrodes ex-tracellular discharge
在线阅读 下载PDF
Bioaugmented design and functional evaluation of low damage implantable array electrodes 被引量:1
7
作者 Ling Wang Chenrui Zhang +9 位作者 Zhiyan Hao Siqi Yao Luge Bai Joaquim Miguel Oliveira Pan Wang Kun Zhang Chen Zhang Jiankang He Rui L.Reis Dichen Li 《Bioactive Materials》 2025年第5期18-31,共14页
Implantable neural electrodes are key components of brain-computer interfaces(BCI),but the mismatch in mechanical and biological properties between electrode materials and brain tissue can lead to foreign body reactio... Implantable neural electrodes are key components of brain-computer interfaces(BCI),but the mismatch in mechanical and biological properties between electrode materials and brain tissue can lead to foreign body reactions and glial scarring,and subsequently compromise the long-term stability of electrical signal transmission.In this study,we proposed a new concept for the design and bioaugmentation of implantable electrodes(bio-array electrodes)featuring a heterogeneous gradient structure.Different composite polyaniline-gelatin-alginate based conductive hydrogel formulations were developed for electrode surface coating.In addition,the design,materials,and performance of the developed electrode was optimized through a combination of numerical simulations and physio-chemical characterizations.The long-term biological performance of the bio-array electrodes were investigated in vivo using a C57 mouse model.It was found that compared to metal array electrodes,the surface charge of the bio-array electrodes increased by 1.74 times,and the impedance at 1 kHz decreased by 63.17%,with a doubling of the average capacitance.Long-term animal experiments showed that the bio-array electrodes could consistently record 2.5 times more signals than those of the metal array electrodes,and the signal-to-noise ratio based on action potentials was 2.1 times higher.The study investigated the mechanisms of suppressing the scarring effect by the bioaugmented design,revealing reduces brain damage as a result of the interface biocompatibility between the bio-array electrodes and brain tissue,and confirmed the long-term in vivo stability of the bio-array electrodes. 展开更多
关键词 Implantable neural electrodes Bioaugmented design BIOCOMPATIBILITY Scar tissue suppression Signal-to-noise ratio
原文传递
Studies on Electrochemical Behavior of Bleomycin and Its Interaction with DNA at a Co/GC Ion Implantation Modified Electrode 被引量:2
8
作者 胡劲波 李启隆 尚军 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第3期267-271,共5页
Electrochemical investigation of Bleomycin (BLM) and its interaction with DNAat a Co/GC ion implantation modified electrode was reported for the first time. The electrochemicalbehavior of BLM at Co/GC modified electro... Electrochemical investigation of Bleomycin (BLM) and its interaction with DNAat a Co/GC ion implantation modified electrode was reported for the first time. The electrochemicalbehavior of BLM at Co/GC modified electrode has been studied by linear sweep and cyclicvoltammetry, The reaction of BLM with DNA formed an electrochemically nonactive complex, whichresulted in a decrease in the BLM equilibrium concentration and its reduction current. The decreasein peak current was proportional to DNA concentration and could be used to determination DNAconcentration. The equilibrium constant of DNA-BLM complex β was determined to be 5.16 x 10^(16).The experiments of AES and XPS showed that Co was surely implanted into the surface of GCE( glassycarbon electrode) and the depth distribution of Co was in good agreement with Gaussian normaldistribution; the implanted Co at GCE improved the electrocatalytic activity. 展开更多
关键词 Co/GC ion implantation modified electrode linear sweep voltammetry BLEOMYCIN DNA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部