期刊文献+
共找到512,905篇文章
< 1 2 250 >
每页显示 20 50 100
Evaluation of the Effectiveness, Accuracy, Specificity, and Sensitivity of High-Frequency Ultrasound in Differentiating Benign and Malignant Breast Micronodules
1
作者 Danhong Yan Weimin Li Hongtao Duan 《Journal of Clinical and Nursing Research》 2025年第9期370-376,共7页
Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between Octob... Objective:To analyze the significance of high-frequency ultrasound in differentiating benign and malignant breast micronodules.Methods:Eighty-five patients with breast micronodules admitted for diagnosis between October 2022 and October 2024 were selected for high-frequency ultrasound diagnosis.The diagnostic efficacy of high-frequency ultrasound was evaluated by comparing it with the results of surgical pathology.Results:High-frequency ultrasound detected 50 benign nodules,primarily breast fibroadenomas,and 35 malignant nodules,mainly breast ductal carcinoma in situ.Based on surgical pathology results,the diagnostic accuracy of high-frequency ultrasound was 96.47%,specificity was 97.96%,and sensitivity was 94.44%.In high-frequency ultrasound diagnosis,the proportion of grade III and IV blood flow in malignant nodules was higher than that in benign nodules,while the proportion of regular shape and clear margins was lower.The proportion of microcalcifications and posterior echo attenuation was higher in malignant nodules,and the resistance index(RI)and peak blood flow velocity were lower than those in benign nodules(P<0.05).Conclusion:High-frequency ultrasound can effectively differentiate benign and malignant breast micronodules,determine specific nodule types,and exhibits high diagnostic accuracy and sensitivity.Additionally,benign and malignant nodules can be differentiated based on the grading of blood flow signals,sonographic features,and blood flow velocity,providing reasonable guidance for subsequent treatment plans. 展开更多
关键词 high-frequency ultrasound Breast micronodules Differentiating benign and malignant ACCURACY Sensitivity
暂未订购
Effectiveness of High-Frequency Electrosurgical Knife Surgery Under Painless Digestive Endoscopy in Elderly Patients with Gastrointestinal Polyps
2
作者 Yumin Lu 《Proceedings of Anticancer Research》 2025年第1期14-20,共7页
Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderl... Objective:To analyze the therapeutic effect of high-frequency electrosurgical knife surgery guided by painless digestive endoscopy(PDE)in elderly patients with gastrointestinal polyps(GP).Methods:A total of 100 elderly GP patients admitted between June 2021 and December 2022 were selected.Patients were randomly divided into two groups:the painless group(50 cases)underwent high-frequency electrosurgical knife surgery guided by PDE,while the conventional group(50 cases)underwent the same surgery guided by traditional digestive endoscopy(DE).The total treatment efficacy,perioperative indicators,gastrointestinal hormone levels,oxidative stress(OS)markers,and complication rates were compared between the two groups.Results:The total treatment efficacy in the painless group was higher than that in the conventional group,and perioperative indicators were superior in the painless group(P<0.05).One week after treatment,the gastrointestinal hormone levels and OS-related markers in the painless group were better than those in the conventional group(P<0.05).The complication rate in the painless group was lower than in the conventional group(P<0.05).Conclusion:High-frequency electrosurgical knife surgery guided by PDE improves the effectiveness of polyp removal in elderly GP patients and accelerates postoperative recovery.It also protects gastrointestinal function,reduces postoperative OS,and ensures higher surgical safety. 展开更多
关键词 Painless digestive endoscopy high-frequency electrosurgical knife surgery Elderly gastrointestinal polyps
暂未订购
Low-frequency signal generation in space based on high-frequency electric-antenna array and Doppler effect
3
作者 CUI Anjing LI Daojing +6 位作者 WU Jiang GAO Jinghan ZHOU Kai HU Chufeng WU Shumei SHI Danni LI Guang 《Journal of Systems Engineering and Electronics》 2025年第1期24-36,共13页
Low-frequency signals have been proven valuable in the fields of target detection and geological exploration.Nevertheless,the practical implementation of these signals is hindered by large antenna diameters,limiting t... Low-frequency signals have been proven valuable in the fields of target detection and geological exploration.Nevertheless,the practical implementation of these signals is hindered by large antenna diameters,limiting their potential applications.Therefore,it is imperative to study the creation of lowfrequency signals using antennas with suitable dimensions.In contrast to conventional mechanical antenna techniques,our study generates low-frequency signals in the spatial domain utilizing the principle of the Doppler effect.We also defines the antenna array architecture,the timing sequency,and the radiating element signal waveform,and provides experimental prototypes including 8/64 antennas based on earlier research.In the conducted experiments,121 MHz,40 MHz,and 10 kHz composite signals are generated by 156 MHz radiating element signals.The composite signal spectrum matches the simulations,proving our low-frequency signal generating method works.This holds significant implications for research on generating low-frequency signals with small-sized antennas. 展开更多
关键词 frequency conversion array signal processing experimental verification Doppler effect
在线阅读 下载PDF
High-frequency spinal cord stimulation produces longlasting analgesic effects by restoring lysosomal function and autophagic flux in the spinal dorsal horn 被引量:4
4
作者 Zhi-Bin Wang Yong-Da Liu +1 位作者 Shuo Wang Ping Zhao 《Neural Regeneration Research》 SCIE CAS CSCD 2022年第2期370-377,共8页
High-frequency spinal cord stimulation(HF-SCS) has been established as an effective therapy for neuropathic pain. However, the analgesic mechanisms involved in HF-SCS remain to be clarified. In our study, adult rat ne... High-frequency spinal cord stimulation(HF-SCS) has been established as an effective therapy for neuropathic pain. However, the analgesic mechanisms involved in HF-SCS remain to be clarified. In our study, adult rat neuropathic pain was induced by spinal nerve ligation. Two days after modeling, the rats were subjected to 4 hours of HF-SCS(motor threshold 50%, frequency 10,000 Hz, and pulse width 0.024 ms) in the dorsal horn of the spinal cord. The results revealed that the tactile allodynia of spinal nerve-injured rats was markedly alleviated by HFSCS, and the effects were sustained for 3 hours after the stimulation had ceased. HF-SCS restored lysosomal function, increased the levels of lysosome-associated membrane protein 2(LAMP2) and the mature form of cathepsin D(matu-CTSD), and alleviated the abnormally elevated levels of microtubule-associated protein 1 A/B-light chain 3(LC3)-II and sequestosome 1(P62) in spinal nerve-injured rats. HF-SCS also mostly restored the immunoreactivity of LAMP2, which was localized in neurons in the superficial layers of the spinal dorsal horn in spinal nerve-injured rats. In addition, intraperitoneal administration of 15 mg/kg chloroquine for 60 minutes reversed the expression of the aforementioned proteins and shortened the timing of the analgesic effects of HF-SCS. These findings suggest that HF-SCS may exhibit longlasting analgesic effects on neuropathic pain in rats through improving lysosomal dysfunction and alleviating autophagic flux. This study was approved by the Laboratory Animal Ethics Committee of China Medical University, Shenyang, China(approval No. 2017 PS196 K) on March 1, 2017. 展开更多
关键词 autolysosome dorsal horn of spinal cord DYSFUNCTION electrical stimulation high-frequency spinal cord stimulation neuropathic pain spinal nerve ligation
暂未订购
Observations on Curative Effect of High-frequency Electric Sparkle and Point-injection Therapy on Knee Osteoarthritis 被引量:6
5
作者 梅志刚 程传国 郑俊峰 《Journal of Traditional Chinese Medicine》 SCIE CAS CSCD 2011年第4期311-315,共5页
Objective: To observe the curative effect of high-frequency electric sparkle and point-injection therapy (HESPT) on knee osteoarthritis (KOA). Methods: Two hundred and five patients were randomly divided into a warmin... Objective: To observe the curative effect of high-frequency electric sparkle and point-injection therapy (HESPT) on knee osteoarthritis (KOA). Methods: Two hundred and five patients were randomly divided into a warming needle moxibustion group (68 cases), a HESPT group (68 cases) and a point-injection group (69 cases). In the warming needle moxibustion group, the main points of Xuehai (SP 10), Neixiyan (EX-LE4), Waixiyan (EX-LE5), Dubi (ST 35), Zusanli (ST 36) and Yanglingquan (GB 34), and the adjunct points of Yinlingquan (SP 9) and Sanyinjiao (SP 6), on the affected side, were chosen for stimulation. In the HESPT group, tenderness points, the main points of Liangqiu (ST 34), Xuehai (SP 10), Neixiyan (EX-LE4), Waixiyan (EX-LE5) and Zusanli (ST 36), and the adjunct points of Yinlingquan (SP 9), Weizhong (BL 40) and Chengshan (BL 57), were chosen. After proper manipulation, Corydalis decumbens Pers. liquid was injected into the points and a high-frequency electric sparkle was applied to stimulate the needles for 30 seconds. In the point-injection group, point injection was performed with the same method, but the patients did not receive electric stimulation. The Western Ontario and McMaster University Osteoarthritis Index (WOMAC), the Lysholm Knee Score Scale (LKSS) and the ROM (Range of Motion) scale were used to evaluate the severity of KOA and the function of knee joints before treatment and 4 weeks after treatment. Finally, the Nimodipine method was used to assess the total curative effect. Results: After HESPT treatment, the scores for pain, morning stiffness and swelling were significantly lower (P<0.01) and LKSS index and ROM were much higher (P<0.01 and P<0.05 respectively) compared to the two other groups. The obviously effective rate and total effective rate were also significantly higher in the HESPT group than in the two other groups (P<0.01 or P<0.05). Conclusion: HESPT can improve joint function in KOA patients, and the curative effect is better than for warming needle moxibustion or point-injection only. 展开更多
关键词 high-frequency electric sparkle and point-injection therapy knee osteoarthritis
原文传递
Neuroprotective effects of subthalamic nucleus high-frequency stimulation on substantia nigra neurons in a Parkinson's disease rat model 被引量:1
6
作者 Yu Ma Zhongcheng Wang +2 位作者 Jianguo Zhang Huanguang Liu Ying Zhang 《Neural Regeneration Research》 SCIE CAS CSCD 2008年第9期1014-1017,共4页
BACKGROUND: Deep-brain stimulation has proven to be beneficial in the treatment of Parkinson's disease (PD) patients. OBJECTIVE: To investigate the effects of high-frequency stimulation (HFS) to the subthalamic... BACKGROUND: Deep-brain stimulation has proven to be beneficial in the treatment of Parkinson's disease (PD) patients. OBJECTIVE: To investigate the effects of high-frequency stimulation (HFS) to the subthalamic nucleus (STN) on neuronal apoptosis and apoptosis-related gene expression in the substantia nigra pars compacta, and to analyze the neuroprotective effect of HFS-STN. DESIGN, TIME AND SETTING: Neuronal morphology experiments were performed in the Beijing Neurosurgical Institute from May to December in 2005. MATERIALS: Forty healthy, adult, Sprague Dawley rats were used to establish a PD model with a unilateral microinjection of 6-hydroxydopamine into two target areas of the right medial forebrain bundle. 6-hydroxydopamine was purchased from Sigma (USA); high-frequency electrical stimulator was produced by World Precision Instruments (USA); Terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) kit was a product of Nanjing Jiancheng Technology Co., Ltd. (China); and Bcl-2 and Bax protein assay kit were purchased from Wuhan Boster Bioengineering Co., Ltd. (China). METHODS: Forty rats were randomly divided into three groups. The stimulation group (n = 15) received HFS-STN on the day of PD modeling. The PD model group (n = 15) was used to establish the PD model. The control group (n = 10) was injected with normal saline containing 0.2 g/L ascorbic acid into two areas of the right medial forebrain bundle. MAIN OUTCOME MEASURES: Survival of dopaminergic neurons in the substantia nigra pars compacta was determined using Nissl staining. Apoptosis of dopaminergic neurons was detected using TUNEL techniques. Expression of anti-apoptotic protein, Bcl-2, and pro-apoptotic protein, Bax, were assayed by immunohistochemistry. RESULTS: Following 6-hydroxydopamine injection, the number of substantia nigra pars compacta neurons was reduced in the stimulation and PD model groups, compared to the control group. At 2 and 4 weeks post-surgery, the grey value of Nissl stained images was significantly less in the PD model and stimulation groups (P 〈 0.05), and the stimulation group exhibited greater grey values compared to the model group (P 〈 0.05). At 2 and 4 weeks post-surgery, the number of apoptotic neurons was significantly less in the stimulation group compared to the model group (P 〈 0.05). In addition, Bcl-2 and Bax expression, as well as the Bcl-2/Bax ratio, was much higher in the stimulation group compared to the model group (P 〈 0.05). CONCLUSION: HFS-STN has a neuroprotective effect on dopaminergic neurons in the substantia nigra pars compacta of PD rats by promoting Bcl-2 expression, inhibiting Bax expression, and reducing the number of apoptotic dopaminergic neurons. 展开更多
关键词 APOPTOSIS deep-brain stimulation: high-frequency stimulation Parkinson's disease
暂未订购
A novel logging method for detecting highly resistive formations in oil-based mud using high-frequency electrodes
7
作者 Kang-Kang Wu Lei Wang +1 位作者 Shao-Gui Deng Xue-Wen Kou 《Petroleum Science》 2025年第5期1946-1958,共13页
The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel l... The oil-based mud(OBM) borehole measurement environment presents significant limitations on the application of existing electrical logging instruments in high-resistance formations. In this paper, we propose a novel logging method for detection of high-resistance formations in OBM using highfrequency electrodes. The method addresses the issue of shallow depth of investigation(DOI) in existing electrical logging instruments, while simultaneously ensuring the vertical resolution. Based on the principle of current continuity, the total impedance of the loop is obtained by equating the measurement loop to the series form of a capacitively coupled circuit. and its validity is verified in a homogeneous formation model and a radial two-layer formation model with a mud standoff. Then, the instrument operating frequency and electrode system parameters were preferentially determined by numerical simulation, and the effect of mud gap on impedance measurement was investigated. Subsequently, the DOI of the instrument was investigated utilizing the pseudo-geometric factor defined by the real part of impedance. It was determined that the detection depth of the instrument is 8.74 cm, while the effective vertical resolution was not less than 2 cm. Finally, a focused high-frequency electrode-type instrument was designed by introducing a pair of focused electrodes, which effectively enhanced the DOI of the instrument and was successfully deployed in the Oklahoma formation model. The simulation results demonstrate that the novel method can achieve a detection depth of 17.40 cm in highly-resistive formations drilling with OBM, which is approximately twice the depth of detection of the existing oil-based mud microimager instruments. Furthermore, its effective vertical resolution remains at or above 2 cm,which is comparable to the resolution of the existing OBM electrical logging instrument. 展开更多
关键词 Oil-based mud Highly-resistive high-frequency electrode Bulking electrode Depth of investigation
原文传递
Study on the Characteristics of High-Frequency Electromagnetic Wave Detection in Goaf Areas along Coal Seam Boreholes
8
作者 Maolin Yang 《Journal of Environmental & Earth Sciences》 2025年第7期272-284,共13页
China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and dis... China has a long history of coal mining,among which open-pit coal mines have a large number of small coal mine goafs underground.The distribution,shape,structure and other characteristics of goafs are isolated and discontinuous,and there is no definite geological law to follow,which seriously threatens the safety of coal mine production and personnel life.Conventional ground geophysical methods have low accuracy in detecting goaf areas affected by mechanical interference from open-pit mines,especially for waterless goaf areas,which cannot be detected by existing methods.This article proposes the use of high-frequency electromagnetic waves for goaf detection.The feasibility of using drilling radar to detect goaf was theoretically analyzed,and a goaf detection model was established.The response characteristics of different fillers in the goaf under different frequencies of high-frequency electromagnetic waves were simulated and analyzed.In a certain open-pit mine in Inner Mongolia,100MHz high-frequency electromagnetic waves were used to detect the goaf through directional drilling on the ground.After detection,excavation verification was carried out,and the location of one goaf detected was verified.The results of engineering practice show that the application of high-frequency electromagnetic waves in goaf detection expands the detection radius of boreholes,has the advantages of high efficiency and accuracy,and has important theoretical and practical significance. 展开更多
关键词 Underground Coal Mine GOAF high-frequency Electromagnetic Wave(HFEW) BOREHOLE
在线阅读 下载PDF
A review on high-frequency electromagnetic interference induced by power electronics in new electric power systems
9
作者 Yundong Hu Xing Lei +3 位作者 Xizhou Du Ting Ye Hongning Song Hao Li 《Global Energy Interconnection》 2025年第5期804-820,共17页
New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed s... New electric power systems characterized by a high proportion of renewable energy and power electronics equipment face significant challenges due to high-frequency(HF)electromagnetic interference from the high-speed switching of power converters.To address this situation,this paper offers an in-depth review of HF interference problems and challenges originating from power electronic devices.First,the root cause of HF electromagnetic interference,i.e.,the resonant response of the parasitic parameters of the system to high-speed switching transients,is analyzed,and various scenarios of HF interference in power systems are highlighted.Next,the types of HF interference are summarized,with a focus on common-mode interference in grounding systems.This paper thoroughly reviews and compares various suppression methods for conducted HF interference.Finally,the challenges involved and suggestions for addressing emerging HF interference problems from the perspective of both power electronics equipment and power systems are discussed.This review aims to offer a structured understanding of HF interference problems and their suppression techniques for researchers and practitioners. 展开更多
关键词 New power system Power electronics Switching transients high-frequency interference Common-mode interference suppression
在线阅读 下载PDF
Efficient activation of the Co/SBA-15catalyst by high-frequency AC-DBD plasma thermal effects for toluene removal
10
作者 李越 姜楠 +5 位作者 刘政妍 秦亮 彭邦发 王荣刚 孙玉荣 李杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期84-94,共11页
Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated d... Dielectric barrier discharge(DBD)plasma excited by a high-frequency alternating-current(AC)power supply is widely employed for the degradation of volatile organic compounds(VOCs).However,the thermal effect generated during the discharge process leads to energy waste and low energy utilization efficiency.In this work,an innovative DBD thermally-conducted catalysis(DBD-TCC)system,integrating high-frequency AC-DBD plasma and its generated thermal effects to activate the Co/SBA-15 catalyst,was employed for toluene removal.Specifically,Co/SBA-15 catalysts are closely positioned to the ground electrode of the plasma zone and can be heated and activated by the thermal effect when the voltage exceeds 10 k V.At12.4 k V,the temperature in the catalyst zone reached 261℃ in the DBD-TCC system,resulting in an increase in toluene degradation efficiency of 17%,CO_(2)selectivity of 21.2%,and energy efficiency of 27%,respectively,compared to the DBD system alone.In contrast,the DBD thermally-unconducted catalysis(DBD-TUC)system fails to enhance toluene degradation due to insufficient heat absorption and catalytic activation,highlighting the crucial role of AC-DBD generated heat in the activation of the catalyst.Furthermore,the degradation pathway and mechanism of toluene in the DBD-TCC system were hypothesized.This work is expected to provide an energy-efficient approach for high-frequency AC-DBD plasma removal of VOCs. 展开更多
关键词 high-frequency alternating-current power thermal effect dielectric barrier discharge toluene degradation Co/SBA-15 catalysts
在线阅读 下载PDF
High-frequency enhanced ultrafast compressed active photography
11
作者 Yizhao Meng Yu Lu +5 位作者 Pengfei Zhang Yi Liu Fei Yin Lin Kai Qing Yang Feng Chen 《Opto-Electronic Advances》 2025年第1期32-43,共12页
Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the ra... Single-shot ultrafast compressed imaging(UCI)is an effective tool for studying ultrafast dynamics in physics,chemistry,or material science because of its excellent high frame rate and large frame number.However,the random code(Rcode)used in traditional UCI will lead to low-frequency noise covering high-frequency information due to its uneven sampling interval,which is a great challenge in the fidelity of large-frame reconstruction.Here,a high-frequency enhanced compressed active photography(H-CAP)is proposed.By uniformizing the sampling interval of R-code,H-CAP capture the ultrafast process with a random uniform sampling mode.This sampling mode makes the high-frequency sampling energy dominant,which greatly suppresses the low-frequency noise blurring caused by R-code and achieves high-frequency information of image enhanced.The superior dynamic performance and large-frame reconstruction ability of H-CAP are verified by imaging optical self-focusing effect and static object,respectively.We applied H-CAP to the spatial-temporal characterization of double-pulse induced silicon surface ablation dynamics,which is performed within 220 frames in a single-shot of 300 ps.H-CAP provides a high-fidelity imaging method for observing ultrafast unrepeatable dynamic processes with large frames. 展开更多
关键词 ultrafast compressed imaging high-frequency enhanced sampling spectral-temporal transform transient processes high-fidelity reconstruction
在线阅读 下载PDF
High-frequency complex permeability calculation for metallic soft magnetic particles with easy magnetization plane in non-magnetic medium
12
作者 Liangrui Tan Donglin He +5 位作者 Zhibiao Xu Guowu Wang Shengyu Yang Shaoyong Leng Ruilong Li Tao Wang 《Chinese Physics B》 2025年第11期254-261,共8页
Soft magnetic composites made from metallic magnetic particles with an easy magnetization plane(referred to as easy-plane metallic soft magnetic composites(SMC))are considered ideal materials for the next generation o... Soft magnetic composites made from metallic magnetic particles with an easy magnetization plane(referred to as easy-plane metallic soft magnetic composites(SMC))are considered ideal materials for the next generation of power electronic devices.This advantage is attributed to their ability to maintain high permeability at elevated frequencies.Despite these advantages,a definitive mathematical model that connects the high-frequency magnetic properties(e.g.,effective permeability)of easy-plane metallic SMCs to the intrinsic properties of the particles is still lacking.In this work,a theoretical calculation model for the effective permeability of easy-plane metallic SMCs was formulated.This model was derived from a skin effect-corrected Landau-Lifshitz-Gilbert(LLG)equation and integrated with effective medium theory incorporating inter-particle interaction.To validate the model,we prepared samples of easy-plane Y_(2)Co_(17)particle/PU SMCs with varying particle sizes and volume fractions.The experimental results showed a strong agreement with the calculated values.This research offers critical theoretical backing for the design and optimization of soft magnetic materials intended for high-frequency applications. 展开更多
关键词 easy-plane material high-frequency soft magnetic composites complex permeability Landau-Lifshitz-Gilbert(LLG)equation
原文传递
Fault Distance EstimationMethod for DC Distribution Networks Based on Sparse Measurement of High-Frequency Electrical Quantities
13
作者 He Wang Shiqiang Li +1 位作者 Yiqi Liu Jing Bian 《Energy Engineering》 2025年第11期4497-4521,共25页
With the evolution of DC distribution networks from traditional radial topologies to more complex multi-branch structures,the number of measurement points supporting synchronous communication remains relatively limite... With the evolution of DC distribution networks from traditional radial topologies to more complex multi-branch structures,the number of measurement points supporting synchronous communication remains relatively limited.This poses challenges for conventional fault distance estimation methods,which are often tailored to simple topologies and are thus difficult to apply to large-scale,multi-node DC networks.To address this,a fault distance estimation method based on sparse measurement of high-frequency electrical quantities is proposed in this paper.First,a preliminary fault line identification model based on compressed sensing is constructed to effectively narrow the fault search range and improve localization efficiency.Then,leveraging the high-frequency impedance characteristics and the voltage-current relationship of electrical quantities,a fault distance estimation approach based on high-frequency measurements from both ends of a line is designed.This enables accurate distance estimation even when the measurement devices are not directly placed at both ends of the faulted line,overcoming the dependence on specific sensor placement inherent in traditional methods.Finally,to further enhance accuracy,an optimization model based on minimizing the high-frequency voltage error at the fault point is introduced to reduce estimation error.Simulation results demonstrate that the proposed method achieves a fault distance estimation error of less than 1%under normal conditions,and maintains good performance even under adverse scenarios. 展开更多
关键词 DC distribution network fault location compressed sensing fault distance estimation high-frequency electrical quantities
在线阅读 下载PDF
Three-dimensional Thermal Network Modeling and Temperature Rise Prediction of Nanocrystalline High-frequency Transformer
14
作者 Baolu Wei Wenliang Zhao +1 位作者 Haibo Ding Haisen Zhao 《CES Transactions on Electrical Machines and Systems》 2025年第4期378-389,共12页
The internal hotspot temperature rise prediction in nanocrystalline high-frequency transformers(nanoHFTs) is essential to ensure reliable operation. This paper presents a three-dimensional thermal network(3DTN) model ... The internal hotspot temperature rise prediction in nanocrystalline high-frequency transformers(nanoHFTs) is essential to ensure reliable operation. This paper presents a three-dimensional thermal network(3DTN) model for epoxy resin encapsulated nano HFTs, which aims to precisely predict the temperature distribution inside the transformer in combination with the finite element method(FEM). A magnetothermal bidirectional coupling 3DTN model is established by analyzing the thermal conduction between the core, windings, and epoxy resin, while also considering the convection and radiation heat transfer mechanisms on the surface of the epoxy resin. The model considers the impact of loss distribution in the core and windings on the temperature field and adopts a simplified 1/2 thermal network model to reduce computational complexity. Furthermore, the results of FEM are compared with experimental results to verify the accuracy of the 3DTN model in predicting the temperature rise of nano HFT. The results show that the 3DTN model reduces errors by an average of 5.25% over the traditional two-dimensional thermal network(2DTN) model, particularly for temperature distributions in the windings and core. This paper provides a temperature rise prediction method for the thermal design and offers a theoretical basis and engineering guidance for the optimization of their thermal management systems. 展开更多
关键词 Three-dimensional thermal network(3DTN) Nanocrystalline high-frequency transformer(nanoHFT) Thermal analysis Temperature rise Convection and radiative heat transfer
在线阅读 下载PDF
Effects of unilateral superimposed high-frequency jet ventilation on porcine hemodynamics and gas exchange during one-lung flooding
15
作者 Thomas Lesser Frank Wolfram +1 位作者 Conny Braun Reiner Gottschall 《World Journal of Experimental Medicine》 2024年第1期88-99,共12页
BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is ... BACKGROUND Superimposed high-frequency jet ventilation(SHFJV)is suitable for respiratory motion reduction and essential for effective lung tumor ablation.Fluid filling of the target lung wing one-lung flooding(OLF)is necessary for therapeutic ultrasound applications.However,whether unilateral SHFJV allows adequate hemodynamics and gas exchange is unclear.AIM To compared SHFJV with pressure-controlled ventilation(PCV)during OLF by assessing hemodynamics and gas exchange in different animal positions.METHODS SHFJV or PCV was used alternatingly to ventilate the non-flooded lungs of the 12 anesthetized pigs during OLF.The animal positions were changed from left lateral position to supine position(SP)to right lateral position(RLP)every 30 min.In each position,ventilation was maintained for 15 min in both modalities.Hemodynamic variables and arterial blood gas levels were repeatedly measured.RESULTS Unilateral SHFJV led to lower carbon dioxide removal than PCV without abnormally elevated carbon dioxide levels.SHFJV slightly decreased oxygenation in SP and RLP compared with PCV;the lowest values of PaO_(2) and PaO_(2)/FiO_(2) ratio were found in SP[13.0;interquartile range(IQR):12.6-5.6 and 32.5(IQR:31.5-38.9)kPa].Conversely,during SHFJV,the shunt fraction was higher in all animal positions(highest in the RLP:0.30).CONCLUSION In porcine model,unilateral SHFJV may provide adequate ventilation in different animal positions during OLF.Lower oxygenation and CO_(2) removal rates compared to PCV did not lead to hypoxia or hypercapnia.SHFJV can be safely used for lung tumor ablation to minimize ventilation-induced lung motion. 展开更多
关键词 One-lung ventilation Unilateral superimposed high-frequency jet ventilation One-lung flooding
在线阅读 下载PDF
Application Effect and Value Analysis of High-frequency Ultrasound in the Diagnosis of Mammary Gland Malignant Tumor
16
作者 LIU Jun 《外文科技期刊数据库(文摘版)医药卫生》 2020年第2期184-186,共5页
Objective: to explore the detection effect and value of high-frequency ultrasound in the diagnosis of mammary gland malignant tumor. Methods: a total of 80 patients with mammary gland malignant tumor in the hospital w... Objective: to explore the detection effect and value of high-frequency ultrasound in the diagnosis of mammary gland malignant tumor. Methods: a total of 80 patients with mammary gland malignant tumor in the hospital were selected as the objects of tumor diagnosis study. All patients were treated with high-frequency color Doppler ultrasound images to detect the tumor and determine its type. At the same time, the detection results were compared with pathological diagnosis results of clinical operation, so as to determine whether the high-frequency ultrasound diagnosis technology has high diagnostic accuracy. Results: the diagnosis accuracy rate reached 96.25% (77/80) after the high-frequency ultrasound diagnosis and the comparison of the diagnosis results with the pathological diagnosis results of clinical operation in 80 patients with mammary gland malignant tumor. Conclusion: the application of high-frequency ultrasound in the diagnosis of mammary gland malignant tumor has high diagnostic accuracy, which can be used as an important basis for clinical diagnosis and treatment. And ensure that patients get treatment in time. 展开更多
关键词 mammary gland malignant tumor high-frequency ultrasonic technology application effect DIAGNOSTIC
暂未订购
Improved high-frequency equivalent circuit model based on distributed effects for SiGe HBTs with CBE layout
17
作者 孙亚宾 李小进 +1 位作者 张金中 石艳玲 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第9期502-508,共7页
In this paper, we present an improved high-frequency equivalent circuit for SiGe heterojunction bipolar transistors(HBTs) with a CBE layout, where we consider the distributed effects along the base region. The actua... In this paper, we present an improved high-frequency equivalent circuit for SiGe heterojunction bipolar transistors(HBTs) with a CBE layout, where we consider the distributed effects along the base region. The actual device structure is divided into three parts: a link base region under a spacer oxide, an intrinsic transistor region under the emitter window,and an extrinsic base region. Each region is considered as a two-port network, and is composed of a distributed resistance and capacitance. We solve the admittance parameters by solving the transmission-line equation. Then, we obtain the smallsignal equivalent circuit depending on the reasonable approximations. Unlike previous compact models, in our proposed model, we introduce an additional internal base node, and the intrinsic base resistance is shifted into this internal base node,which can theoretically explain the anomalous change in the intrinsic bias-dependent collector resistance in the conventional compact model. 展开更多
关键词 SiGe heterojunction bipolar transistors(HBT) small-signal equivalent circuit distributed effects CBE layout
原文传递
Electronically Conductive Metal−Organic Framework With Photoelectric and Photothermal Effect as a Stable Cathode for High-Temperature Photo-Assisted Zn/Sn-Air Battery
18
作者 Jiangchang Chen Chuntao Yang +2 位作者 Yao Dong Ya Han Yingjian 《Carbon Energy》 2026年第1期105-114,共10页
Rechargeable Zn/Sn-air batteries have received considerable attention as promising energy storage devices.However,the electrochemical performance of these batteries is significantly constrained by the sluggish electro... Rechargeable Zn/Sn-air batteries have received considerable attention as promising energy storage devices.However,the electrochemical performance of these batteries is significantly constrained by the sluggish electrocatalytic reaction kinetics at the cathode.The integration of light energy into Zn/Sn-air batteries is a promising strategy for enhancing their performance.However,the photothermal and photoelectric effects generate heat in the battery under prolonged solar irradiation,leading to air cathode instability.This paper presents the first design and synthesis of Ni_(2)-1,5-diamino-4,8-dihydroxyanthraquinone(Ni_(2)DDA),an electronically conductiveπ-d conjugated metal-organic framework(MOF).Ni_(2)DDA exhibits both photoelectric and photothermal effects,with an optical band gap of~1.14 eV.Under illumination,Ni_(2)DDA achieves excellent oxygen evolution reaction performance(with an overpotential of 245 mV vs.reversible hydrogen electrode at 10 mA cm^(−2))and photothermal stability.These properties result from the synergy between the photoelectric and photothermal effects of Ni_(2)DDA.Upon integration into Zn/Sn-air batteries,Ni_(2)DDA ensures excellent cycling stability under light and exhibits remarkable performance in high-temperature environments up to 80℃.This study experimentally confirms the stable operation of photo-assisted Zn/Sn-air batteries under high-temperature conditions for the first time and provides novel insights into the application of electronically conductive MOFs in photoelectrocatalysis and photothermal catalysis. 展开更多
关键词 electronically conductive MOFs high temperatures photo-assisted Zn/Sn-air batteries photoelectric effects photothermal effects
在线阅读 下载PDF
CUDA‑based GPU‑only computation for efficient tracking simulation of single and multi‑bunch collective effects
19
作者 Keon Hee Kim Eun‑San Kim 《Nuclear Science and Techniques》 2026年第1期61-79,共19页
Beam-tracking simulations have been extensively utilized in the study of collective beam instabilities in circular accelerators.Traditionally,many simulation codes have relied on central processing unit(CPU)-based met... Beam-tracking simulations have been extensively utilized in the study of collective beam instabilities in circular accelerators.Traditionally,many simulation codes have relied on central processing unit(CPU)-based methods,tracking on a single CPU core,or parallelizing the computation across multiple cores via the message passing interface(MPI).Although these approaches work well for single-bunch tracking,scaling them to multiple bunches significantly increases the computational load,which often necessitates the use of a dedicated multi-CPU cluster.To address this challenge,alternative methods leveraging General-Purpose computing on Graphics Processing Units(GPGPU)have been proposed,enabling tracking studies on a standalone desktop personal computer(PC).However,frequent CPU-GPU interactions,including data transfers and synchronization operations during tracking,can introduce communication overheads,potentially reducing the overall effectiveness of GPU-based computations.In this study,we propose a novel approach that eliminates this overhead by performing the entire tracking simulation process exclusively on the GPU,thereby enabling the simultaneous processing of all bunches and their macro-particles.Specifically,we introduce MBTRACK2-CUDA,a Compute Unified Device Architecture(CUDA)ported version of MBTRACK2,which facilitates efficient tracking of single-and multi-bunch collective effects by leveraging the full GPU-resident computation. 展开更多
关键词 Code development GPU computing Collective effects
在线阅读 下载PDF
Synergistic antibacterial effect and mechanism of benzalkonium chloride and polymyxin B against Pseudomonas aeruginosa
20
作者 Caihong Wang Jiaxin Zhang +3 位作者 Tong Li Jingwei Wang Dan Xu Qiao Ma 《Journal of Environmental Sciences》 2026年第1期555-564,共10页
Benzalkonium chloride(BAC)is widely employed as a broad-spectrum biocide and has emerged as a significant environmental pollutant.Polymyxin B(PB)serves as the last-line defense for the treatment of Gram-negative patho... Benzalkonium chloride(BAC)is widely employed as a broad-spectrum biocide and has emerged as a significant environmental pollutant.Polymyxin B(PB)serves as the last-line defense for the treatment of Gram-negative pathogens.Previous studies reported that BAC-adapted Pseudomonas aeruginosa increased the tolerance to PB.Herein,we present the novel finding that the combination of BAC and PB exhibited synergistic antibacterial effects against P.aeruginosa.Time-killing assay demonstrated a significant reduction in bacterial cell viability.Scanning electron microscopy,zeta potential analysis,hydrophobicity measurements,and fluorescence probe analyses collectively revealed severe disruption of the cell envelope and membrane potential induced by the combination of BAC and PB.Transcriptomic analysis revealed that the BAC-PB combination notably downreg-ulated the expression of genes involved in lipid A modification and cell envelope production,including phoPQ,pmrAB,bamABCDE,lptABCDEG,lolB,yidC,and murJ.Additionally,the combination group exhibited augmented production of reactive oxygen species and diminished ATP synthesis.The expression of the genes associated with substance metabolism and energy generation was significantly impeded.This study provides significant implica-tions for the interactions of biocides and antibiotics on Gram-negative pathogens,while also addressing antibiotic resistance and developing the external treatment strategy for Pseudomonas-infected wounds and burns. 展开更多
关键词 Pseudomonas aeruginosa Benzalkonium chloride Polymyxin B Synergistic effect Membrane disruption
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部