期刊文献+
共找到166篇文章
< 1 2 9 >
每页显示 20 50 100
Association between preoperative high sensitive troponin I levels and cardiovascular events after hip fracture surgery in the elderly 被引量:16
1
作者 Bum Sung Kim Tae-Hoon Kim +5 位作者 Jeong-Hwan Oh Chang Hee Kwon Sung Hea Kim Hyun-Joong Kim Heung Kon Hwang Sang-Man Chung 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第3期215-221,共7页
Objective Cardiovascular complications contribute to postoperative morbidity and mortality in elderly hip fracture patients.Limited data are available regarding which preoperative risk factors predict cardiovascular c... Objective Cardiovascular complications contribute to postoperative morbidity and mortality in elderly hip fracture patients.Limited data are available regarding which preoperative risk factors predict cardiovascular course following hip fracture surgery(HFS).We used high sensitive troponin I(hs-TnI)assays and clinical parameters to identify preoperative risk factors associated with major adverse cardiac events(MACE)in elderly hip frac^u'e patients.Method From August 2014 to November 2016,575 patients with hip fracture were enrolled in a retrospective,single-center registry.A total of 262 of these patients underwent HFS and hs-TnI assays.MACE was defined as postoperative all-cause deaths,heart failure(HF),new-onset atrial fibrillation(AF),myocardial infarction(MI)and cardiovascular re-hospitalization that occurred within 90 days postoperative.Results Of 262 HFS patients,MACE developed following HFS in 65(24.8%).Patients with MACE were older and had higher rates of renal insufficiency,coronary artery disease,prior HF,low left ventricular ejection fraction and use of beta blockers;higher levels of hs-Tnl and N-terminal pro-brain natriuretic peptide(NT-proBNP)and higher revised cardiac risk index.A preoperative hs-TnI≥6.5 ng/L was associated with high risk of postoperative HF,new-onset AF and MACE.In multivariable analysis,pre-operative independent predictors for MACE were age〉80 years[adjusted hazard ratio(HR):1.79,95%confident interval(CI):1.03-3.13,P=0.04],left ventricular ejection fraction(LVEF)〈50%(adjusted HR:3.17,95%CI:1.47-5.82,P〈0.01)and hs-TnI〉6.5 ng/L(adjusted HR:3.75,95%CI:2.09~5.17,P〈0.01).Conclusion In elderly patients with hip fracture who undergo HFS,a preoperative assessment of hs-TnI may help the risk refinement of cardiovascular complications. 展开更多
关键词 Cardiovascular complication high sensitive troponin I Hip fracture surgery
在线阅读 下载PDF
Elevated high sensitive C-reactive protein and apelin levels after percutaneous coronary intervention and drug-eluting stent implantation 被引量:4
2
作者 Xin DU Jun-ping KANG +3 位作者 Jia-hui WU Qiang LV Chao-shu TANG Chang-sheng MA 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2010年第8期548-552,共5页
Objective:Percutaneous coronary intervention(PCI) triggers an acute inflammatory response,while sirolimus is known to have anti-inflammatory properties;the inflammatory system response to PCI after sirolimus-eluting s... Objective:Percutaneous coronary intervention(PCI) triggers an acute inflammatory response,while sirolimus is known to have anti-inflammatory properties;the inflammatory system response to PCI after sirolimus-eluting stent placement remains unclear.The purpose of this study is to determine the changes in high sensitive C-reactive protein(hs-CRP) and apelin after PCI procedure and drug-eluting stent implantation in patients with and without reduced left ventricular systolic function.Methods:Forty-eight consecutive patients undergoing PCI at the Beijing Anzhen Hospital between July and September 2006 were recruited.Sirolimus-eluting stents were employed in all patients.Blood samples were drawn immediately before and 24 h after the procedure.Plasma hs-CRP and apelin levels were determined by enzyme immunoassay.Results:Paired t-test revealed a significant increase in both hs-CRP and apelin post-procedure(P=0.006 and P<0.0001,respectively).Patients with reduced left ventricular ejection fraction(LVEF) had significantly lower baseline apelin levels compared to those with normal ventricular function [(46.8±10.8) vs.(72.0±8.4) pg/ml,P<0.001].However,apelin increased to a level similar to the level of those with normal left ventricular systolic function 24 h after the PCI procedure [(86.7±11.6) vs.(85.1±6.1) pg/ml,P=0.72].Conclusions:hs-CRP and apelin levels increased after PCI and sirolimus-eluting stent implantation.Patients with impaired left ventricular systolic function had significantly lower baseline apelin levels,which increased significantly after PCI. 展开更多
关键词 high sensitive C-reactive protein (hs-CRP) APELIN Percutaneous colonary intervention (PCl)
原文传递
Correlation of Enhancement Degree on Contrast-enhanced Ultrasound with Histopathology of Carotid Plaques and Serum High Sensitive C-Reactive Protein Levels in Patients Undergoing Carotid Endarterectomy 被引量:3
3
作者 熊莉 孙伟军 +3 位作者 蔡华英 杨园 朱江 赵博文 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第3期425-428,共4页
This study was undertaken to investigate the correlation of the enhancement degree on contrast-enhanced ultrasound(CEUS) with the histopathology of carotid plaques and the serum high sensitive C-reactive protein(hs-CR... This study was undertaken to investigate the correlation of the enhancement degree on contrast-enhanced ultrasound(CEUS) with the histopathology of carotid plaques and the serum high sensitive C-reactive protein(hs-CRP) levels in patients undergoing carotid endarterectomy(CEA). Carotid CEUS was performed preoperatively in 115 patients who would undergo CEA, and the enhancement degree of the carotid plaques was evaluated by both the visual semiquantitative analysis and the quantitative time-intensity curve analysis. Serum hs-CRP levels were detected using the particle-enhanced immunoturbidimetric assay also before the operation. Additionally, the carotid plaque samples were subjected to histopathological examination postoperatively. The density of neovessels and the number of macrophages in the plaques were assessed by immunohistochemistry. The results showed that among the 115 patients, grade 0 plaque contrast enhancement was noted in 35 patients, grade 1 in 48 patients and grade 2 in 32 patients. The degree of plaque enhancement, the density of neovessels, the number of macrophages, and the hs-CRP levels were highest in the grade 2 patients. Correlation analysis showed that the enhancement degree of the carotid plaques was closely related to the immunohistochemical parameters of the plaques and the serum hs-CRP levels. It was suggested that the carotid plaque enhancement on CEUS can be used to evaluate the vulnerability of carotid plaques. 展开更多
关键词 carotid plaque NEOVASCULARIZATION contrast-enhanced ultrasound carotid endarterectomy high sensitive C-reactive protein
暂未订购
EFFECTS OF SIMVASTAIN COMBINED WITH OMEGA-3 FATTY ACIDS ON HIGH SENSITIVE C-REACTIVE PROTEIN, LIPIDEMIA, ANDFIBRINOLYSIS IN PATIENTS WITH MIXED DYSLIPIDEMIA 被引量:1
4
作者 HengHong Zhi-minXu +5 位作者 Bao-senPang LiangCui YuWei Wen-jingGuo Yan-lingMao Xin-chunYang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第2期145-149,共5页
Objective To evaluate the effects of simvastatin combined with omega-3 fatty acids on high sensitive C-reactive protein(HsCRP), lipidemia, and fibrinolysis in coronary heart disease (CHD) and CHD risk equivalent patie... Objective To evaluate the effects of simvastatin combined with omega-3 fatty acids on high sensitive C-reactive protein(HsCRP), lipidemia, and fibrinolysis in coronary heart disease (CHD) and CHD risk equivalent patients with mixed dyslipi-demia. Methods A randomized, double-blind placebo controlled and parallel group trial was conducted. Patients with CHD and CHD risk equivalents with mixed dyslipidemia were treated with 10 or 20 mg simvastatin for 6-12 weeks. Following with the treatment of patients whose low-density lipoprotein cholesterol (LDL-ch) reaching goal level (< 100 mg/dL) or close to the goal (< 130 mg/dL), while triglyceride (TG) ≥200 mg/dL and < 500 mg/dL, was combined with omega-3 fatty acids (3 g/d) or a placebo for 2 months. The effects of the treatment on HsCRP, total cholesterol (TC), LDL-ch, high-density lipoprotein cholesterol (HDL-ch), TG, lipoprotein (a) [LP (a)], apolipoprotein A1 (apoA1), apolipoprotein B (apoB), plasminogen activator inhibitor-1 (PAI-1), and tissue plasminogen activator (tPA) were investigated. Forty patients finished the study with each group consisting of twenty patients. Results (1) There were significant reductions of HsCRP, TG, TC, and TC/HDL-ch, which decreased by 2.16 ±2.77 mg/L (38.5%), 94.0 ±65.4 mg/dL (31.1%), 13.3 ±22.3 mg/dL (6.3%), 0.78 ±1.60 respectively in the omega-3 fatty acids group (P< 0.01, < 0.001, < 0.05, < 0.05) compared to the baseline. HsCRP and triglyceride reduction were more significant in omega-3 fatty acids group compared to the placebo group (P=0.021 and 0.011 respectively). (2) In the omega-3 fatty acids group, the values and percentage of TG reduction had a significantly positive relation with HsCRP reduction (r=0.51 and 0.45, P=0.021 and 0.047 respectively). Conclusion In CHD and CHD risk equivalent patients with mixed dyslipidemia, dyslipidemia’s therapeutic effect using simvastatin and omega-3 fatty acids may result from not only the combination of lipid adjustment, but also enhancement of their own nonlipid influences. 展开更多
关键词 simvastation omega-3 fatty acids mixed dyslipidemia high sensitive C-reactive protein
暂未订购
Archean Basement and a Paleoproterozoic Collision Orogen in the Huoqiu Area at the Southeastern Margin of North China Craton: Evidence from Sensitive High Resolution Ion Micro-Probe U-Pb Zircon Geochronology 被引量:38
5
作者 WAN Yusheng DONG Chunyan WANG Wei XIE Hangqiang LIU Dunyi 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2010年第1期91-104,共14页
This paper reports sensitive high resolution ion micro-probe U-Pb zircon ages for the "Huoqiu Group" and granitoids of the Early Precambrian basement in the Huoqiu area, southeastern margin of the North China Craton... This paper reports sensitive high resolution ion micro-probe U-Pb zircon ages for the "Huoqiu Group" and granitoids of the Early Precambrian basement in the Huoqiu area, southeastern margin of the North China Craton. The "Huoqiu Group" is similar in rock association and metamorphism to the khondalite series, apart from it containing considerable amounts of banded iron formation. All detrital zircons from the "Huoqiu Group" meta-sedimentary rocks are 3.0 Ga and 2.75 Ga, without any 2.5 Ga and younger ones, as is commonly found in Paleoproterozoic khondalite series in other areas of the North China Craton. In the Huoqiu area, 2.75 Ga and 2.56 Ga granitoids have also been identified. This basement assemblage underwent strong metamorphism during the late Paleoproterozoic (-1.84 Ga) tectonothermal event that is widely developed in the North China Craton. Thus the formation time of the "Huoqiu Group" can be constrained between 2.75 and 1.84 Ga in terms of detrital and metamorphic zircon ages. It is considered, combined with regional data, that there may be a Paleoproterozoic collision orogen extending in a NWW-SEE direction to the southern margin of the North China Craton. 展开更多
关键词 khondalite series trondhjemite-tonalite-granodiorite sensitive high resolution ion micro-probe U-Pb dating ARCHEAN PALEOPROTEROZOIC collision orogen North China Craton
在线阅读 下载PDF
A highly sensitive luminescent metal-organic framework thermometer for physiological temperature sensing 被引量:8
6
作者 Lin Zhang Yadan Xie +3 位作者 Tifeng Xia Yuanjing Cui Yu Yang Guodong Qian 《Journal of Rare Earths》 SCIE EI CAS CSCD 2018年第6期561-566,共6页
Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developin... Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developing luminescent thermometers due to their remarkable structural diversities and tunable luminescence properties. Here, we synthesized a series of luminescent mixed-lanthanide MOFs,EuTbBPT(x = 0.019, 0.058, 0.106; H3 BPT = biphenyl-3,4’,5-tricarboxylate acid) and adopted powder X-ray diffraction(PXRD), thermogravimetric analysis(TGA) and Fourier transform infrared(FT-IR) to characterize the resulting products. The temperature-dependent photoluminescence emission spectra were recorded to investigate their potential applications in physiological temperature readout. It is found that the intensity ratio of Tbto Euis linearly correlated with temperature and the relative sensitivity is higher than 1.5%/℃ over the entire physiological temperature range. Furthermore,the temperaturedependent luminescence color emission allows for visual colorimetric temperature measurements.Luminescence lifetime testing and triplet energy level measurement were further conducted to study the mechanism. 展开更多
关键词 Lanthanide metal-organic frameworks Luminescent thermometer RATIOMETRIC COLORIMETRIC high sensitivity Physiological temperature
原文传递
Rational designed microstructure pressure sensors with highly sensitive and wide detection range performance 被引量:3
7
作者 Yimeng Ni Lexin Liu +4 位作者 Jianying Huang Shuhui Li Zhong Chen Weiying Zhang Yuekun Lai 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2022年第35期184-192,共9页
Highly sensitive pressure sensors are often deployed in human-machine interaction area,touch screen and human motion detection.However,there are still great challenges to fabricating with high sensitivity pressure sen... Highly sensitive pressure sensors are often deployed in human-machine interaction area,touch screen and human motion detection.However,there are still great challenges to fabricating with high sensitivity pressure sensor with wide-range detection.Herein,we developed a new strategy to fabricate a highly sensitive pressure sensor using sandpaper and improve its detection range using a sacrificial template.It was the fthatirst time to combine microstructure processing with the sacrificial template method to fabricate pressure sensor.The microstructure of sandpaper endowed the sensor with high sensitivity,and the elastic substrate enhanced the sensor ability to resist high pressure without being damaged.The fabricated sensor device exhibits a superior sensitivity of 39.077 kPa-1in the range from 50 kPa to 110 kPa with a broad linear response.Remarkably,high pressure ceiling(<160 kPa) ensures that the sponge could be applied in different practical conditions to monitor a range of subtle human motions including finger,wrist bending,and pulse.For applications,the sensor device can not only detect the foot stepping behavior(0.7 MPa) but also produce an obvious response to an extremely slight paper(9 mg,~0.9 Pa).The successful preparation of this micro-structured elastic sponge material provided new ideas for exploring its potential applications in pressure sensors and flexible wearable electronic devices. 展开更多
关键词 Pressure sensor high sensitivity Conductive sponge TEMPLATE MICRO-STRUCTURE
原文传递
Highly sensitive digital optical sensor with large measurement range based on the dual-microring resonator with waveguide-coupled feedback 被引量:3
8
作者 向星烨 王葵如 +3 位作者 苑金辉 晋博源 桑新柱 余重秀 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期284-288,共5页
We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the se... We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the sensitivity of the sensor can be orders of magnitude higher than that of aconventional sensor, and high quality factor is not critical in it. Moreover, by optimizing the length of the feedback waveguide to be equal to the perimeter of the ring, the measurement range of the proposed sensor is twice as much as that of the conventional sensor in the weak coupling case. 展开更多
关键词 optical sensor microring resonator high sensitivity large measurement range
原文传递
Highly sensitive and stretchable piezoelectric strain sensor enabled wearable devices for real-time monitoring of respiratory and heartbeat simultaneously 被引量:2
9
作者 Zhenjie Ji Menglun Zhang 《Nanotechnology and Precision Engineering》 CAS CSCD 2022年第1期12-23,共12页
The World Health Organization has declared COVID-19 a pandemic.The demand for devices or systems to diagnose and track COVID-19 infections noninvasively not only in hospitals but also in home settings has led to incre... The World Health Organization has declared COVID-19 a pandemic.The demand for devices or systems to diagnose and track COVID-19 infections noninvasively not only in hospitals but also in home settings has led to increased interest in consumer-grade wearables.A common symptom of COVID-19 is dyspnea,which may manifest as an increase in respiratory and heart rates.In this paper,a novel piezoelectric strain sensor is presented for real-time monitoring of respiratory and heartbeat signals.A highly sensitive and stretchable piezoelectric strain sensor is fabricated using a piezoelectric film with a serpentine layout.The thickness of the patterned PVDF flexible piezoelectric strain sensor is only 168μm,and the voltage sensitivity reaches 0.97 mV/με.The effective modulus is 13.5 MPa,which allows the device to fit to the skin and detect the small strain exhibited by the human body.Chest vibrations are captured by the piezoelectric sensor,which produces an electrical output voltage signal conformally mapped with respiratory–cardiac activities.The separate heart activity and respiratory signals are extracted from the mixed respiratory–cardiac signal by an empirical mode decomposition data processing algorithm.By detecting vital signals such as respiratory and heart rates,the proposed device can aid early diagnosis and monitoring of respiratory diseases such as COVID-19. 展开更多
关键词 Physiological signal Strain sensor high sensitivity FLEXIBILITY Early diagnosis COVID-19
在线阅读 下载PDF
Engineering high-performance dielectric chiral shells with enhanced chiral fields for sensitive chiral biosensor 被引量:2
10
作者 Yi-Fan Wang Shan-Shan Huang +4 位作者 Zhen-Dong Dai Shi-Lin Xian Xuan-Nan Wu Fu-Hua Gao Yi-Dong Hou 《Rare Metals》 SCIE EI CAS CSCD 2024年第3期1197-1206,共10页
Chiral metamaterials have been a topic of significant research interest in recent years due to their potential for various applications in nanophotonic devices and chiral biosensors.However,the intrinsic Ohmic loss in... Chiral metamaterials have been a topic of significant research interest in recent years due to their potential for various applications in nanophotonic devices and chiral biosensors.However,the intrinsic Ohmic loss in surface plasmonic resonance has limited their practical use,resulting in large light dissipation and weak chiroptical resonance.Here,we report on the development of high-performance dielectric chiral shells(DCS)through a two-step Si deposition process on a self-assembled microsphere monolayer.The form DCS sample completely oyercomes the cancelation effect originated from the disorder property of the micro-sphere monolayer in macroscale,and at a wavelength of approximately 710 nm,the measured optimal chiral signal(g-factor)and transmittance can reach up to 0.7 and 0.3,respectively.The strong chiroptical effect comes from the asymmetric circular displacement currents(i.e.,magnetic modes)enabled by the specific shell geometry.The chiral shell geometry,electromagnetic properties,sensor sensitivity of chiral molecules and figure of merit are systematically investigated.The DCSs demonstrate highly sensitive detection of chiral biomolecules owing to their easily accessible geometry and enhanced uniform chiral field. 展开更多
关键词 Dielectric chiral shells(DCS) Si deposition Magnetic resonance highly sensitive sensor Chiral field
原文传递
MXene-composited highly stretchable,sensitive and durable hydrogel for flexible strain sensors 被引量:11
11
作者 Wei Yuan Xinyu Qu +5 位作者 Yao Lu Wen Zhao Yanfang Ren Qian Wang Wenjun Wang Xiaochen Dong 《Chinese Chemical Letters》 CSCD 2021年第6期2021-2026,共6页
The flourishing development in flexible electronics has provoked intensive research in flexible strain sensors to realize accurate perception acquisition under different external stimuli.However,building hydrogel-base... The flourishing development in flexible electronics has provoked intensive research in flexible strain sensors to realize accurate perception acquisition under different external stimuli.However,building hydrogel-based strain sensors with high stretchability and sensitivity remains a great challenge.Herein,MXene nanosheets were composited into polyacrylamide-sodium alginate matrix to construct mechanical robust and sensitive double networked hydrogel strain sensor.The hydrophilic MXene nanosheets formed strong interactions with the polymer matrix and endowed the hydrogel with excellent tensile properties(3150%),compliant mechanical strength(2.03 kPa^(-1)in Young’s Module)and long-lasting stability and fatigue resistance(1000 dynamic cycles under 1,600%strain).Due to the highly oriented MXene-based three dimensional conductive networks,the hydrogel sensor achieved extremely high tensile sensitivity(18.15 in gauge factor)and compression sensitivity(0.38 kPa^(-1)below 3 kPa).MXene hydrogel-based strain sensors also displayed negligible hysteresis in electromechanical performance,typical frequent-independent feature and rapid response time to external stimuli.Moreover,the sensor exhibited accurate response to different scales of human movements,providing potential application in speech recognition,expression recognition and handwriting verification. 展开更多
关键词 HYDROGEL MXene Strain sensor high stretchablity and sensitivity DURABILITY
原文传递
Rational design of an AIE-active metal-organic framework for highly sensitive and portable sensing nitroaromatic explosives 被引量:1
12
作者 Luyao Wang Weichao Chen +7 位作者 Weilin Song Jingjing Tian Jing Sun Lili Wen Chunyi Sun Xinlong Wang Zhongmin Su Guo-Gang Shan 《Chinese Chemical Letters》 SCIE CAS CSCD 2023年第3期481-485,共5页
Herein,we report a new metal-organic framework with an AIE ligand (H_(4)TCPP=2,3,5,6-tetra-(4-carboxyphenyl)pyrazine) and Mg^(2+) ions,that is,[Mg_(2)(H_(2)O)_(4)TCPP]·DMF·5CH_(3)CN (Mg-TCPP,TCPP=tetra-(4-ca... Herein,we report a new metal-organic framework with an AIE ligand (H_(4)TCPP=2,3,5,6-tetra-(4-carboxyphenyl)pyrazine) and Mg^(2+) ions,that is,[Mg_(2)(H_(2)O)_(4)TCPP]·DMF·5CH_(3)CN (Mg-TCPP,TCPP=tetra-(4-carboxyphenyl)pyrazine) for detection of nitroaromatic explosives.Due to the coordination effect and restricted intramolecular rotation,Mg-TCPP exhibits bright blue light.As a fluorescent sensor,Mg-TCPP exhibits high selectivity and sensitivity for sensing 2,4,6-trinitrophenol (TNP) by quenching behaviors with the Stern-Volmer quenching constant (K_(SV)) of 3.63×10^(5)L/mol and achieves the low limit of detection of 25.6 ppb,which is beyond most of the previously reported fluorescent materials.Notably,the portable Mg-TCPP films are prepared and it can be used for rapid and sensitive TNP detection in a variety of environments including organic solvent and aqueous solution.Moreover,TNP vapor can be detected within 3 min by naked eye and the film could be regenerated under simple solvent cleaning. 展开更多
关键词 Metal-organic frameworks Aggregation induced-emission Nitroaromatic compounds SENSOR high sensitivity
原文传递
Highly sensitive Fe^(3+)luminescence detection via single-ion adsorption 被引量:1
13
作者 Yujing Li Xiaojun Zhang +2 位作者 Zicheng Wang Lina Zhao Yuxin Li 《Chinese Chemical Letters》 SCIE CAS CSCD 2024年第1期431-434,共4页
To achieve a lower detection limit has always been a goal of analytical chemists.Herein,we demonstrate the first picomolar level detection capability for Fe3+ion via luminescence detection technology.The results of st... To achieve a lower detection limit has always been a goal of analytical chemists.Herein,we demonstrate the first picomolar level detection capability for Fe3+ion via luminescence detection technology.The results of structural analysis and theoretical calculation show that Fe3+ions are adsorbed on the central node of Eu-DBM(DBM=dibenzoylmethane)sensor in the form of single ion at ultralow concentration.Subsequently,the pathways of photo-induced charge and energy transfer of the obtained Eu-DBM@Fe^(3+)material have been changed,from the initial DBM-to-Eu^(3+)before Fe^(3+)adsorption to the ultimate DBM-to-Fe^(3+)after adsorption process,which quenches the luminescence of Eu3+ion.This work not only obtains the highly sensitive luminescence detection ability,but also innovatively proposes the single-ion adsorption mechanism,both of which have important scientific and application values for the development of more efficient detection agents in the future. 展开更多
关键词 Luminescence detection Lanthanide complex high sensitivity Fe^(3+)ion Single-ion adsorption
原文传递
Highly sensitive and stable probe refractometer based on configurable plasmonic resonance with nano-modified fiber core 被引量:1
14
作者 Jianying Jing Kun Liu +3 位作者 Junfeng Jiang Tianhua Xu Shuang Wang Tiegen Liu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第6期38-51,共14页
A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achi... A dispersion model is developed to provide a generic tool for configuring plasmonic resonance spectral characteristics.The customized design of the resonance curve aiming at specific detection requirements can be achieved.According to the model,a probe-type nano-modified fiber optic configurable plasmonic resonance(NMF-CPR)sensor with tip hot spot enhancement is demonstrated for the measurement of the refractive index in the range of 1.3332-1.3432 corresponding to the low-concentration biomarker solution.The new-type sensing structure avoids excessive broadening and redshift of the resonance dip,which provides more possibilities for the surface modification of other functional nanomaterials.The tip hot spots in nanogaps between the Au layer and Au nanostars(AuNSs),the tip electric field enhancement of AuNSs,and the high carrier mobility of the WSe_(2)layer synergistically and significantly enhance the sensitivity of the sensor.Ex-perimental results show that the sensitivity and the figure of merit of the tip hot spot enhanced fiber NMF-CPR sensor can achieve up to 2995.70 nm/RIU and 25.04 RIU^(−1),respectively,which are 1.68 times and 1.29 times higher than those of the conventional fiber plasmonic resonance sensor.The results achieve good agreements with numerical simulations,demonstrate a better level compared to similar reported studies,and verify the correctness of the dispersion model.The detection resolution of the sensor reaches up to 2.00×10^(−5)RIU,which is obviously higher than that of the conventional side-polished fiber plasmonic resonance sensor.This indicates a high detection accuracy of the sensor.The dense Au layer effectively prevents the intermediate nanomaterials from shedding and chemical degradation,which enables the sensor with high stability.Furthermore,the terminal reflective sensing structure can be used as a practical probe and can allow a more convenient operation. 展开更多
关键词 fiber photonics sensor customized plasmonic resonance curve nano-modified fiber core tip hot spot effect high sensitivity and stability
在线阅读 下载PDF
Tunable and highly sensitive temperature sensor based on graphene photonic crystal fiber
15
作者 Xu Cheng Xu Zhou +6 位作者 Chen Huang Can Liu Chaojie Ma Hao Hong Wentao Yu Kaihui Liu Zhongfan Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第11期136-140,共5页
Optical fiber temperature sensors have been widely employed in enormous areas ranging from electric power industry,medical treatment,ocean dynamics to aerospace.Recently,graphene optical fiber temperature sensors attr... Optical fiber temperature sensors have been widely employed in enormous areas ranging from electric power industry,medical treatment,ocean dynamics to aerospace.Recently,graphene optical fiber temperature sensors attract tremendous attention for their merits of simple structure and direct power detecting ability.However,these sensors based on transfer techniques still have limitations in the relatively low sensitivity or distortion of the transmission characteristics,due to the unsuitable Fermi level of graphene and the destruction of fiber structure,respectively.Here,we propose a tunable and highly sensitive temperature sensor based on graphene photonic crystal fiber(Gr-PCF)with the non-destructive integration of graphene into the holes of PCF.This hybrid structure promises the intact fiber structure and transmission mode,which efficiently enhances the temperature detection ability of graphene.From our simulation,we find that the temperature sensitivity can be electrically tuned over four orders of magnitude and achieve up to~3.34×10^(-3) dB/(cm·℃)when the graphene Fermi level is~35 meV higher than half the incident photon energy.Additionally,this sensitivity can be further improved by~10 times through optimizing the PCF structure(such as the fiber hole diameter)to enhance the light–matter interaction.Our results provide a new way for the design of the highly sensitive temperature sensors and broaden applications in all-fiber optoelectronic devices. 展开更多
关键词 GRAPHENE photonic crystal fiber temperature sensor high sensitivity Fermi level
原文传递
Flexible broadband WS_(2)/Si optical position-sensitive detector with high sensitivity and fast speed
16
作者 Yunjie Liu Yupeng Wu +5 位作者 Fuhai Guo Yingming Liu Shirong Zhao Siqi Li Weizhuo Yu Lanzhong Hao 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第6期1217-1224,共8页
Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the application... Si-based optical position-sensitive detectors(PSDs)have stimulated the interest of researchers due to their wide range of practical applications.However,due to the rigidity and fragility of Si crystals,the applications of flexible PSDs have been limited.Therefore,we presented a flexible broadband PSD based on a WS_(2)/Si heterostructure for the first time.A scalable sputtering method was used to deposit WS_(2)thin films onto the etched ultrathin crystalline Si surface.The fabricated flexible PSD device has a broad spectral response in the wavelength range of 450-1350 nm,with a high position sensitivity of~539.8 mV·mm^(−1)and a fast response of 2.3μs,thanks to the strong light absorption,the built-in electrical field at the WS_(2)/Si interface,and facilitated transport.Furthermore,mechanical-bending tests revealed that after 200 mechanical-bending cycles,the WS_(2)/Si PSDs have excellent mechanical flexibility,stability,and durability,demonstrating the great potential in wearable PSDs with competitive performance. 展开更多
关键词 FLEXIBLE position-sensitive detectors WS^(2)heterostructure broad spectral response high sensitivity
在线阅读 下载PDF
HIGHLY SENSITIVE SPECTROPHOTOMETRY OF NIOBIUM
17
作者 Zong Ming LUO Department of Chemical Engineering,Guangdong Institute of Technology,Guangzhou,510090 《Chinese Chemical Letters》 SCIE CAS CSCD 1990年第2期131-132,共2页
In pH 2.0-3.0 medium,niobium(v)forms molybdoniobic acid with sodium molybdate.A spectrophotometric method has been developed for the determination of niobium based on the formation of ion-associate compound of molybdo... In pH 2.0-3.0 medium,niobium(v)forms molybdoniobic acid with sodium molybdate.A spectrophotometric method has been developed for the determination of niobium based on the formation of ion-associate compound of molybdoniobate with butyl Rhodamine B in aqueous solution in the presence of polyvinyl alcohol and 0.4-0.7 mol/L H_2SO_4.The molar absorptivity is 7.5×10~5 L.mol^(-1).cm^(-1) for niobium at 585 nm. 展开更多
关键词 ACID highLY sensitive SPECTROPHOTOMETRY OF NIOBIUM IV
在线阅读 下载PDF
Highly Sensitive Detection of Deoxyribonucleic Acid Hybridization Using Au-Gated AlInN/GaN High Electron Mobility Transistor-Based Sensors
18
作者 Xiang-Mi Zhan Mei-Lan Ha +7 位作者 Quan Wang Wei Li Hong-Ling Xiao Chun Feng Li-Juan Jiang Cui-Mei Wang Xiao-Liang Wang Zhan-Guo Wang 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第4期75-78,共4页
Gallium nitride- (GaN) based high electron mobility transistors (HEMTs) provide a good platform for biological detection. In this work, both Au-gated AlInN/GaN HEMT and AlGaN/GaN HEMT biosensors are fabricated for... Gallium nitride- (GaN) based high electron mobility transistors (HEMTs) provide a good platform for biological detection. In this work, both Au-gated AlInN/GaN HEMT and AlGaN/GaN HEMT biosensors are fabricated for the detection of deoxyribonucleic acid (DNA) hybridization. The Au-gated AIInN/GaN HEMT biosensor exhibits higher sensitivity in comparison with the AlGaN/GaN HEMT biosensor. For the former, the drain-source current (VDS = 0.5 V) shows a clear decrease of 69μA upon the introduction of 1μmolL^-1 (μM) complimentary DNA to the probe DNA at the sensor area, while for the latter it is only 38 μA. This current reduction is a notable indication of the hybridization. The high sensitivity can be attributed to the thinner barrier of the AlInN/GaN heterostructure, which makes the two-dimensional electron gas channel more susceptible to a slight change of the surface charge. 展开更多
关键词 GAN In highly sensitive Detection of Deoxyribonucleic Acid Hybridization Using Au-Gated AlInN/GaN high Electron Mobility Transistor-Based Sensors
原文传递
Highly Sensitive Fiber-Optic Faraday-Effect Magnetic Field Sensor Based on Yttrium Iron Garnet
19
作者 Wenbo FEI (Department of Physics, Northeastern Universitys Shenyang 110006, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期205-206,共2页
The principle and performance of a fiber-optic Faraday-effect magnetic-field sensor based on an yttrium iron garnet (YIG) and two flux concentrations are described. A single polarization-maintaining optical fiber link... The principle and performance of a fiber-optic Faraday-effect magnetic-field sensor based on an yttrium iron garnet (YIG) and two flux concentrations are described. A single polarization-maintaining optical fiber links the sensor head to the source and detection system, in which the technique of phase shift cancellation is used to cancel the phase shift that accumulatein the optical fiber. Flux concentrators were exploited to enhance the YIG crystal magneto-optic sensitivity .The sensor system exhibited a noise-equivalent field of 8 pT/√Hz and a 3 dB bandwidth of ~10 MHz. 展开更多
关键词 YIG highly sensitive Fiber-Optic Faraday-Effect Magnetic Field Sensor Based on Yttrium Iron Garnet
在线阅读 下载PDF
The Influence of Regular Hemodialysis on the Highly Sensitive Troponin-I Level in Children without Any Symptoms
20
作者 Hekmat Mohamed Maha Youssef +1 位作者 Manal Abdel-Salam Shayma A. Mohammed 《Open Journal of Nephrology》 2021年第2期183-198,共16页
<strong>Backgrounds:</strong> Cardiovascular diseases are still the prominent cause of death in cases of end-stage renal disease, cardiac troponin I (cTnI) can be used for detecting cardiac involvement in ... <strong>Backgrounds:</strong> Cardiovascular diseases are still the prominent cause of death in cases of end-stage renal disease, cardiac troponin I (cTnI) can be used for detecting cardiac involvement in asymptomatic cases of end-stage renal disease on hemodialysis. <strong>Aim:</strong> Determine the direct cardiac consequence of dialysis treatments in children on hemodialysis by measuring high-sensitive troponin-I as a marker of myocardial injury. <strong>Subjects and Methods:</strong> This case-control study included thirty children with end-stage renal disease on regular hemodialysis;the study group was selected from the nephrology hemodialysis unit of Al-Zahraa Hospital, Al-Azhar University. Another group of thirty healthy children matches age and sex with the patient’s group as a control. Highly Sensitive cTnI (hsTnI) was measured pre and post hemodialysis with a sensitive assay;moreover, ECG, lipid profile including cholesterol, triglyceride, low and high-density lipoprotein (HDL) in the same line with routine investigations for those patients, we used bioimpedance for dry weight assessment in the hemodialysis (HD) group. <strong>Results:</strong> Children on (HD) have a significantly higher (hsTnI) pre-dialysis (0.250 ± 0.069 ng/ml) compared to post-dialysis (0.187 ± 0.004 ng/ml) with (p, 0.001). With no significant difference between post HD (0.187 ± 0.004 ng/ml) and the control group (0.189 ± 0.005) with (p, 0.090). cTnI is detected in (73.3%) of children pre-dialysis above the cut-off value compared to (3.31%) had a high-level post-dialysis. cTnI is positively correlated with systolic, diastolic blood pressure and heart rate with (r. 0.333, p, 0.001: r. 0.343, p, 0.001: r. 0.276, p, 0.033) respectively and (hsTnI) is negatively correlated with Hb and HDL (r. -0.333, p, 0.009: r. 0.324, p, 0.011). Meanwhile (hsTnI) is positively correlated with serum urea, creatinine, ph, PTH, serum ferritin and positively correlated with QT interval and QTC. <strong>Conclusion:</strong> cTnI levels rise significantly before hemodialysis, so those patients are exposed to silent myocardial injury pre HD, and fortunately, it is not persistent after hemodialysis except for a few of them had a high level. We strongly advised not to delay dialysis appointments;the nephrology team should aggressively treat those patients to prevent further myocardial damage. 展开更多
关键词 highly sensitive Troponin-I CHILDREN HEMODIALYSIS
暂未订购
上一页 1 2 9 下一页 到第
使用帮助 返回顶部