期刊文献+
共找到4,068篇文章
< 1 2 204 >
每页显示 20 50 100
Temperature error compensation method for fiber optic gyroscope based on a composite model of k-means,support vector regression and particle swarm optimization 被引量:1
1
作者 CAO Yin LI Lijing LIANG Sheng 《Journal of Systems Engineering and Electronics》 2025年第2期510-522,共13页
As the core component of inertial navigation systems, fiber optic gyroscope (FOG), with technical advantages such as low power consumption, long lifespan, fast startup speed, and flexible structural design, are widely... As the core component of inertial navigation systems, fiber optic gyroscope (FOG), with technical advantages such as low power consumption, long lifespan, fast startup speed, and flexible structural design, are widely used in aerospace, unmanned driving, and other fields. However, due to the temper-ature sensitivity of optical devices, the influence of environmen-tal temperature causes errors in FOG, thereby greatly limiting their output accuracy. This work researches on machine-learn-ing based temperature error compensation techniques for FOG. Specifically, it focuses on compensating for the bias errors gen-erated in the fiber ring due to the Shupe effect. This work pro-poses a composite model based on k-means clustering, sup-port vector regression, and particle swarm optimization algo-rithms. And it significantly reduced redundancy within the sam-ples by adopting the interval sequence sample. Moreover, met-rics such as root mean square error (RMSE), mean absolute error (MAE), bias stability, and Allan variance, are selected to evaluate the model’s performance and compensation effective-ness. This work effectively enhances the consistency between data and models across different temperature ranges and tem-perature gradients, improving the bias stability of the FOG from 0.022 °/h to 0.006 °/h. Compared to the existing methods utiliz-ing a single machine learning model, the proposed method increases the bias stability of the compensated FOG from 57.11% to 71.98%, and enhances the suppression of rate ramp noise coefficient from 2.29% to 14.83%. This work improves the accuracy of FOG after compensation, providing theoretical guid-ance and technical references for sensors error compensation work in other fields. 展开更多
关键词 fiber optic gyroscope(FOG) temperature error com-pensation composite model machine learning CLUSTERING regression.
在线阅读 下载PDF
Vibration-induced bias error reduction using loop gain compensation for high-precision fiber optic gyroscopes
2
作者 CHEN Heyu QIN Xuexin +2 位作者 XIE Huan KONG Linghai ZHENG Yue 《Journal of Systems Engineering and Electronics》 2025年第1期224-232,共9页
Vibration-induced bias deviation,which is generated by intensity fluctuations and additional phase differences,is one of the vital errors for fiber optic gyroscopes(FOGs)operating in vibration environment and has seve... Vibration-induced bias deviation,which is generated by intensity fluctuations and additional phase differences,is one of the vital errors for fiber optic gyroscopes(FOGs)operating in vibration environment and has severely restricted the applications of high-precision FOGs.The conventional methods for suppressing vibration-induced errors mostly concentrate on reinforcing the mechanical structure and optical path as well as the compensation under some specific operation parameters,which have very limited effects for high-precision FOGs maintaining performances under vibration.In this work,a technique of suppressing the vibration-induced bias deviation through removing the part related to the varying gain from the rotation-rate output is put forward.Particularly,the loop gain is extracted out by adding a gain-monitoring wave.By demodulating the loop gain and the rotation rate simultaneously under distinct frequencies and investigating their quantitative relationship,the vibrationinduced bias error is compensated without limiting the operating parameters or environments,like the applied modulation depth.The experimental results show that the proposed method has achieved the reduction of bias error from about 0.149°/h to0.014°/h during the random vibration with frequencies from20 Hz to 2000 Hz.This technique provides a feasible route for enhancing the performances of high-precision FOGs heading towards high environmental adaptability. 展开更多
关键词 vibration-induced error fiber optic gyroscope(FOG) loop gain
在线阅读 下载PDF
A self-correction algorithm for positioning error in sequential point bending tests of a microbeam for Young’s modulus based on atomic force microscopy
3
作者 Yuxin Liu Linyan Xu 《Nanotechnology and Precision Engineering》 2025年第3期131-137,共7页
The single-point bending method,based on atomic force microscopy(AFM),has been extensively validated for characterizing the structural mechanical properties of micro-and nanobeams.Nevertheless,the influence of AFM pro... The single-point bending method,based on atomic force microscopy(AFM),has been extensively validated for characterizing the structural mechanical properties of micro-and nanobeams.Nevertheless,the influence of AFM probe loading and positioning has yet to be subjected to comprehensive investigation.This paper proposes a novel bending-test method based on sequential loading points,in which a series of evenly distributed loads are applied along the length of the central axis on the upper surface of the cantilever.The preliminary measured values of Young’s modulus for an unknown alloy material were 193,178,and 176 GPa,exhibiting a considerable degree of dispersion.An algorithm for self-correction of the positioning error was developed,and this resulted in a positioning error of 53 nm and a final converged Young’s modulus of 161 GPa. 展开更多
关键词 Microbeam structure Young’s modulus Sequential point bending test Self-correcting positioning error Atomic force microscopy
在线阅读 下载PDF
Gross errors identification and correction of in-vehicle MEMS gyroscope based on time series analysis 被引量:3
4
作者 陈伟 李旭 张为公 《Journal of Southeast University(English Edition)》 EI CAS 2013年第2期170-174,共5页
This paper presents a novel approach to identify and correct the gross errors in the microelectromechanical system (MEMS) gyroscope used in ground vehicles by means of time series analysis. According to the characte... This paper presents a novel approach to identify and correct the gross errors in the microelectromechanical system (MEMS) gyroscope used in ground vehicles by means of time series analysis. According to the characteristics of autocorrelation function (ACF) and partial autocorrelation function (PACF), an autoregressive integrated moving average (ARIMA) model is roughly constructed. The rough model is optimized by combining with Akaike's information criterion (A/C), and the parameters are estimated based on the least squares algorithm. After validation testing, the model is utilized to forecast the next output on the basis of the previous measurement. When the difference between the measurement and its prediction exceeds the defined threshold, the measurement is identified as a gross error and remedied by its prediction. A case study on the yaw rate is performed to illustrate the developed algorithm. Experimental results demonstrate that the proposed approach can effectively distinguish gross errors and make some reasonable remedies. 展开更多
关键词 microelectromechanical system (MEMS)gyroscope autoregressive integrated moving average(ARIMA) model time series analysis gross errors
在线阅读 下载PDF
Periodic Error Compensation for Quartz MEMS Gyroscope Drift of INS 被引量:14
5
作者 Xu Jianmao Zhang Haipeng Sun Junzhong 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2007年第6期539-545,共7页
In order to improve the navigation accuracy of an inertial navigation system (INS), composed of quartz gyroscopes, the existing real-time compensation methods for periodic errors in quartz gyroscope drift and the pe... In order to improve the navigation accuracy of an inertial navigation system (INS), composed of quartz gyroscopes, the existing real-time compensation methods for periodic errors in quartz gyroscope drift and the periodic error term relationship between sampled original data and smoothed data are reviewed. On the base of the results, a new compensation method called using former period characteristics to compensate latter smoothness data (UFCL for short) method is proposed considering the INS working characteristics. This new method uses the original data without smoothing to work out an error conversion formula at the INS initial alignment time and then compensate the smoothed data errors by way of the formula at the navigation time. Both theoretical analysis and experimental results demonstrate that this method is able to cut down on computational time and raise the accuracy which makes it a better real-time compensation approach for periodic error terms of quartz micro electronic mechanical system (MEMS) gyroscope's zero drift. 展开更多
关键词 real-time compensation quartz MEMS gyroscope periodic error period characteristic inertial navigation system (INS)
在线阅读 下载PDF
Low drift nuclear spin gyroscope with probe light intensity error suppression 被引量:4
6
作者 Wenfeng Fan Wei Quan +2 位作者 Feng Liu Lihong Duan Gang Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第11期129-133,共5页
A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxationfree(SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. Howe... A nuclear spin gyroscope based on an alkali-metal–noble-gas co-magnetometer operated in spin-exchange relaxationfree(SERF) regime is a promising atomic rotation sensor for its ultra-high fundamental sensitivity. However, the fluctuation of probe light intensity is one of the main technical error sources that limits the bias stability of the gyroscope. Here we propose a novel method to suppress the bias error induced by probe light intensity fluctuations. This method is based on the inherent magnetic field response characteristics of the gyroscope. By the application of a bias magnetic field, the gyroscope can be tuned to a working point where the output signal is insensitive to probe light intensity variation, referred to herein as ‘zero point’, thus the bias error induced by intensity fluctuations can be completely suppressed. The superiority of the method was verified on a K–Rb–21 Ne co-magnetometer, and a bias stability of approximately 0.01°/h was obtained. In addition, the method proposed here can remove the requirement of the closed-loop control of probe light intensity, thereby facilitating miniaturization of the gyroscope volume and improvement of reliability. 展开更多
关键词 nuclear spin gyroscope SPIN-EXCHANGE relaxation-free error SUPPRESSION PROBE light intensity
原文传递
Tests and error analysis of a self-positioning shearer operating at a manless working face 被引量:17
7
作者 FANG Xinqiu ZHAO Junjie HU Yuan 《Mining Science and Technology》 EI CAS 2010年第1期53-58,共6页
Self-positioning of a shearer is the key technology for mining with a man-less working face. In an underground coal mine all radio navigation; satellite positioning or celestial navigation methods have their limitatio... Self-positioning of a shearer is the key technology for mining with a man-less working face. In an underground coal mine all radio navigation; satellite positioning or celestial navigation methods have their limitations. We analyzed an inertial navi-gation system intended to guide the movement a shearer and designed a self-positioning device for the shearer. Simulation tests were also performed on the system. We analyzed the errors observed in these tests to show that the main reason for the low preci-sion of the self-positioning system is accumulated error in the inertial sensor. A Kalman filtering algorithm used in combination with the shearer motion model effectively reduces the measurement errors of the self-positioning system by compensating for gyroscopic drift. Finally, we built an error compensation model to reduce accumulated errors using continuous correction to provide self-positioning of the shearer within a certain range of accuracy. 展开更多
关键词 SHEARER SELF-POSITIONING testS error compensation model Kalman Filter
在线阅读 下载PDF
Identification of Kinematic Errors of Five-axis Machine Tool Trunnion Axis from Finished Test Piece 被引量:3
8
作者 ZHANG Ya FU Jianzhong CHEN Zichen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第5期999-1007,共9页
Compared with the traditional non-cutting measurement,machining tests can more accurately reflect the kinematic errors of five-axis machine tools in the actual machining process for the users.However,measurement and c... Compared with the traditional non-cutting measurement,machining tests can more accurately reflect the kinematic errors of five-axis machine tools in the actual machining process for the users.However,measurement and calculation of the machining tests in the literature are quite difficult and time-consuming.A new method of the machining tests for the trunnion axis of five-axis machine tool is proposed.Firstly,a simple mathematical model of the cradle-type five-axis machine tool was established by optimizing the coordinate system settings based on robot kinematics.Then,the machining tests based on error-sensitive directions were proposed to identify the kinematic errors of the trunnion axis of cradle-type five-axis machine tool.By adopting the error-sensitive vectors in the matrix calculation,the functional relationship equations between the machining errors of the test piece in the error-sensitive directions and the kinematic errors of C-axis and A-axis of five-axis machine tool rotary table was established based on the model of the kinematic errors.According to our previous work,the kinematic errors of C-axis can be treated as the known quantities,and the kinematic errors of A-axis can be obtained from the equations.This method was tested in Mikron UCP600 vertical machining center.The machining errors in the error-sensitive directions can be obtained by CMM inspection from the finished test piece to identify the kinematic errors of five-axis machine tool trunnion axis.Experimental results demonstrated that the proposed method can reduce the complexity,cost,and the time consumed substantially,and has a wider applicability.This paper proposes a new method of the machining tests for the trunnion axis of five-axis machine tool. 展开更多
关键词 five-axis machine tool kinematic errors trunnion axis test piece error-sensitive directions
在线阅读 下载PDF
Vibration test of micro machined gyroscope based on high speed photography and SURF 被引量:1
9
作者 姚峰林 高世桥 +1 位作者 赵婕 高崇仁 《Journal of Beijing Institute of Technology》 EI CAS 2012年第2期179-184,共6页
Based on three kinds of dynamic test of MEMS, a dynamic system for the vibration test of micro machined gyroscope based on high speed photography is introduced. Firstly, the architecture of the system hardware is intr... Based on three kinds of dynamic test of MEMS, a dynamic system for the vibration test of micro machined gyroscope based on high speed photography is introduced. Firstly, the architecture of the system hardware is introduced. Secondly, the image tracking performance is compared by the test using the template matching algorithm, the mean shift algorithm and the SURF algorithm. The vibration curve shows that high speed photograph combined with SURF algorithm is faster, more ac- curate, and more suitable for the vibration test of micro machined gyroscope. After the frequency a- nalysis and related interpolation, more characteristics of micro gyroscope can be obtained. 展开更多
关键词 high speed photograph SURF micro machined gyroscope dynamic test VIBRATION IMAGE
在线阅读 下载PDF
APPROXIMATE POWER OF HETEROSCEDASTICITY TEST IN NONLINEAR MODELS WITH ARIMA(0,1,0) ERRORS 被引量:1
10
作者 Lin Jinguan Wei Bocheng Zhang Nansong 《Applied Mathematics(A Journal of Chinese Universities)》 SCIE CSCD 2005年第4期423-430,共8页
This paper presents an approach for estimating power of the score test, based on an asymptotic approximation to the power of the score test under contiguous alternatives. The method is applied to the problem of power ... This paper presents an approach for estimating power of the score test, based on an asymptotic approximation to the power of the score test under contiguous alternatives. The method is applied to the problem of power calculations for the score test of heteroscedasticity in European rabbit data (Ratkowsky, 1983). Simulation studies are presented which indicate that the asymptotic approximation to the finite-sample situation is good over a wide range of parameter configurations. 展开更多
关键词 ARIMA (0 1 0) errors asymptotic approximation HETEROSCEDASTICITY local power nonlinear model score test.
在线阅读 下载PDF
Statistical Diagnosis and Gross Error Test for Semiparametric Linear Model 被引量:1
11
作者 DING Shijun ZHANG Songlin JIANG Weiping WANG Shouchun 《Geo-Spatial Information Science》 2009年第4期296-302,共7页
This paper systematically studies the statistical diagnosis and hypothesis testing for the semiparametric linear regression model according to the theories and methods of the statistical diagnosis and hypothesis testi... This paper systematically studies the statistical diagnosis and hypothesis testing for the semiparametric linear regression model according to the theories and methods of the statistical diagnosis and hypothesis testing for parametric regression model.Several diagnostic measures and the methods for gross error testing are derived.Especially,the global and local influence analysis of the gross error on the parameter X and the nonparameter s are discussed in detail;at the same time,the paper proves that the data point deletion model is equivalent to the mean shift model for the semiparametric regression model.Finally,with one simulative computing example,some helpful conclusions are drawn. 展开更多
关键词 parametric regression semiparametric linear model influencing analysis statistical diagnosis gross error testing
原文传递
A Study on Measurement Error during Alternating Current Induced Voltage Tests on Large Transformers 被引量:1
12
作者 WANG Xuan LI Yun-ge +1 位作者 CAO Xiao-long LIU Ying 《International Journal of Plant Engineering and Management》 2006年第1期17-24,共8页
The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the wor... The large transformer is pivotal equipment in an electric power supply system; Its partial discharge test and the induced voltage withstand test on large transformers are carried out at a frequency about twice the working frequency. If the magnetizing inductance cannot compensate for the stray capacitance, the test sample turns into a capacitive load and a capacitive rise exhibits in the testing circuit. For self-restoring insulation, a method has been recommended in IEC60-1 that an unapproved measuring system be calibrated by an approved system at a voltage not less than 50% of the rated testing voltage, and the result then be extrapolated linearly. It has been found that this method leads to great error due to the capacitive rise if it is not correctly used during a withstand voltage test under certain testing conditions, especiaUy for a test on high voltage transformers with large capacity. Since the withstand voltage test is the most important means to examine the operation reliability of a transformer, and it can be destructive to the insulation, a precise measurement must be guaranteed. In this paper a factor, named as the capacitive rise factor, is introduced to assess the rise. The voltage measurement error during the calibration is determined by the parameters of the test sample and the testing facilities, as well as the measuring point. Based on theoretical analysis in this paper, a novel method is suggested and demonstrated to estimate the error by using the capacitive rise factor and other known parame- ters of the testing circuit. 展开更多
关键词 TRANSFORMER test MEASUREMENT error
在线阅读 下载PDF
Dynamics and Attitude Error Analysis for Dock Test System of Small Satellite
13
作者 张元 孙丽丽 +1 位作者 赖一楠 戴野 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第4期372-379,共8页
To analyze the attitude errors of vertical docking test system of small satellite,the static error and kinematic error of test system are considered.The working principle of test system and coordinate of actuator are ... To analyze the attitude errors of vertical docking test system of small satellite,the static error and kinematic error of test system are considered.The working principle of test system and coordinate of actuator are introduced.The model of friction torque on the joints and torque on docking mechanism are built.Dynamics equation of actuator is built by the Lagrange equation and the Nielsen equation.Under the condition of 24 different angle groups,the calculation of dynamics equation is built by using MATLAB/SIMULINK platform and the kinematic errors of actuator are obtained.The attitude error models of docking mechanism are built.Results shows that the main angle error sources of yaw,row,pitch are not identical.The attitude error of yaw angle can be decreased by compensating the angle error around xaxis.The attitude error of row angle mainly originates in the system error,and it can be eliminated by adjusting non-orthogonal degree. 展开更多
关键词 attitude error test system angle errors dynamics equation
在线阅读 下载PDF
TESTING OF CORRELATION AND HETEROSCEDASTICITY IN NONLINEAR REGRESSION MODELS WITH DBL(p,q,1) RANDOM ERRORS
14
作者 刘应安 韦博成 《Acta Mathematica Scientia》 SCIE CSCD 2008年第3期613-632,共20页
Chaos theory has taught us that a system which has both nonlinearity and random input will most likely produce irregular data. If random errors are irregular data, then random error process will raise nonlinearity (K... Chaos theory has taught us that a system which has both nonlinearity and random input will most likely produce irregular data. If random errors are irregular data, then random error process will raise nonlinearity (Kantz and Schreiber (1997)). Tsai (1986) introduced a composite test for autocorrelation and heteroscedasticity in linear models with AR(1) errors. Liu (2003) introduced a composite test for correlation and heteroscedasticity in nonlinear models with DBL(p, 0, 1) errors. Therefore, the important problems in regression model axe detections of bilinearity, correlation and heteroscedasticity. In this article, the authors discuss more general case of nonlinear models with DBL(p, q, 1) random errors by score test. Several statistics for the test of bilinearity, correlation, and heteroscedasticity are obtained, and expressed in simple matrix formulas. The results of regression models with linear errors are extended to those with bilinear errors. The simulation study is carried out to investigate the powers of the test statistics. All results of this article extend and develop results of Tsai (1986), Wei, et al (1995), and Liu, et al (2003). 展开更多
关键词 DBL(p Q 1) random errors nonlinear regression models score test HETEROSCEDASTICITY CORRELATION
在线阅读 下载PDF
On the Distribution of Type II Errors in Hypothesis Testing
15
作者 Skip Thompson 《Applied Mathematics》 2011年第2期189-195,共7页
When a statistical test of hypothesis for a population mean is performed, we are faced with the possibility of committing a Type II error by not rejecting the null hypothesis when in fact the population mean has chang... When a statistical test of hypothesis for a population mean is performed, we are faced with the possibility of committing a Type II error by not rejecting the null hypothesis when in fact the population mean has changed. We consider this issue and quantify matters in a manner that differs a bit from what is commonly done. In particular, we define the probability distribution function for Type II errors. We then explore some interesting properties that we have not seen mentioned elsewhere for this probability distribution function. Finally, we discuss several Maple procedures that can be used to perform various calculations using the distribution. 展开更多
关键词 COMPLEMENTARY error Function HYPOTHESIS testing POWER CURVES POWER Surfaces Type II errorS
暂未订购
Dynamic error research and application of an angular measuring system belonging to a high precision excursion test turntable
16
作者 邓辉宇 王欣利 马培荪 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第2期156-159,共4页
Angular measuring system is the most important component of a servo turntable in inertial test apparatus. Its function and precision determine the turntable' s function and precision. It attaches importance to resear... Angular measuring system is the most important component of a servo turntable in inertial test apparatus. Its function and precision determine the turntable' s function and precision. It attaches importance to research on inertial test equipment. This paper introduces the principle of the angular measuring system using amplitude discrimination mode. The dynamic errors axe analyzed from the aspects of inductosyn, amplitude and function error of double-phase voltage and wavefonn distortion. Through detailed calculation, theory is provided for practical application; system errors are allocated and the angular measuring system meets the accuracy requirement. As a result, the schedule of the angular measuring system can be used in practice. 展开更多
关键词 test turntable angular measuring system dynamic error error model
在线阅读 下载PDF
Robust Principal Component Test in Gross Error Detection and Identification
17
作者 高倩 阎威武 邵惠鹤 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第5期553-558,共6页
Principle component analysis (PCA) based chi-square test is more sensitive to subtle gross errors and has greater power to correctly detect gross errors than classical chi-square test. However, classical principal c... Principle component analysis (PCA) based chi-square test is more sensitive to subtle gross errors and has greater power to correctly detect gross errors than classical chi-square test. However, classical principal com- ponent test (PCT) is non-robust and can be very sensitive to one or more outliers. In this paper, a Huber function liked robust weight factor was added in the collective chi-square test to eliminate the influence of gross errors on the PCT. Meanwhile, robust chi-square test was applied to modified simultaneous estimation of gross error (MSEGE) strategy to detect and identify multiple gross errors. Simulation results show that the proposed robust test can reduce the possibility of type Ⅱ errors effectively. Adding robust chi-square test into MSEGE does not obviously improve the power of multiple gross error identification, the proposed approach considers the influence of outliers on hypothesis statistic test and is more reasonable. 展开更多
关键词 gross error detection and identification chi-square test ROBUST principle component analysis (PCA) modified simultaneous estimation of gross error (MSEGE)
在线阅读 下载PDF
Comparison of Type I Error Rates of Siegel-Tukey and Savage Tests among Non-Parametric Tests
18
作者 Sahib Ramazanov Hakan Çora 《Open Journal of Applied Sciences》 2024年第9期2393-2410,共18页
This study aimed to examine the performance of the Siegel-Tukey and Savage tests on data sets with heterogeneous variances. The analysis, considering Normal, Platykurtic, and Skewed distributions and a standard deviat... This study aimed to examine the performance of the Siegel-Tukey and Savage tests on data sets with heterogeneous variances. The analysis, considering Normal, Platykurtic, and Skewed distributions and a standard deviation ratio of 1, was conducted for both small and large sample sizes. For small sample sizes, two main categories were established: equal and different sample sizes. Analyses were performed using Monte Carlo simulations with 20,000 repetitions for each scenario, and the simulations were evaluated using SAS software. For small sample sizes, the I. type error rate of the Siegel-Tukey test generally ranged from 0.045 to 0.055, while the I. type error rate of the Savage test was observed to range from 0.016 to 0.041. Similar trends were observed for Platykurtic and Skewed distributions. In scenarios with different sample sizes, the Savage test generally exhibited lower I. type error rates. For large sample sizes, two main categories were established: equal and different sample sizes. For large sample sizes, the I. type error rate of the Siegel-Tukey test ranged from 0.047 to 0.052, while the I. type error rate of the Savage test ranged from 0.043 to 0.051. In cases of equal sample sizes, both tests generally had lower error rates, with the Savage test providing more consistent results for large sample sizes. In conclusion, it was determined that the Savage test provides lower I. type error rates for small sample sizes and that both tests have similar error rates for large sample sizes. These findings suggest that the Savage test could be a more reliable option when analyzing variance differences. 展开更多
关键词 Non-Parametric test Siegel-Tukey test Savage test Monte Carlo Simulation Type I error
在线阅读 下载PDF
A flexible and robust soft-error testing system for microelectronic devices and integrated circuits
19
作者 王晓辉 童腾 +7 位作者 苏弘 刘杰 张战刚 古松 刘天奇 孔洁 赵兴文 杨振雷 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第3期64-70,共7页
Single event effects(SEEs) induced by radiations become a significant challenge to the reliability for modern electronic systems. To evaluate SEEs susceptibility for microelectronic devices and integrated circuits(ICs... Single event effects(SEEs) induced by radiations become a significant challenge to the reliability for modern electronic systems. To evaluate SEEs susceptibility for microelectronic devices and integrated circuits(ICs), an SEE testing system with flexibility and robustness was developed at Heavy Ion Research Facility in Lanzhou(HIRFL). The system is compatible with various types of microelectronic devices and ICs, and supports plenty of complex and high-speed test schemes and plans for the irradiated devices under test(DUTs). Thanks to the combination of meticulous circuit design and the hardened logic design, the system has additional performances to avoid an overheated situation and irradiations by stray radiations. The system has been tested and verified by experiments for irradiating devices at HIRFL. 展开更多
关键词 微电子器件 测试系统 集成电路 软误差 重离子研究装置 HIRFL 现代电子系统 辐照装置
在线阅读 下载PDF
Sensitivity and Specificity Analysis Relation to Statistical Hypothesis Testing and Its Errors: Application to Cryptosporidium Detection Techniques
20
作者 Emmanuel de-Graft Johnson Owusu-Ansah Angelina Sampson +1 位作者 Amponsah K. Samuel Abaidoo Robert 《Open Journal of Applied Sciences》 2016年第4期209-216,共8页
The use of Statistical Hypothesis Testing procedure to determine type I and type II errors was linked to the measurement of sensitivity and specificity in clinical trial test and experimental pathogen detection techni... The use of Statistical Hypothesis Testing procedure to determine type I and type II errors was linked to the measurement of sensitivity and specificity in clinical trial test and experimental pathogen detection techniques. A theoretical analysis of establishing these types of errors was made and compared to determination of False Positive, False Negative, True Positive and True Negative. Experimental laboratory detection methods used to detect Cryptosporidium spp. were used to highlight the relationship between hypothesis testing, sensitivity, specificity and predicted values. The study finds that, sensitivity and specificity for the two laboratory methods used for Cryptosporidium detection were low hence lowering the probability of detecting a “false null hypothesis” for the presence of cryptosporidium in the water samples using either Microscopic or PCR. Nevertheless, both procedures for cryptosporidium detection had higher “true negatives” increasing its probability of failing to reject a “true null hypothesis” with specificity of 1.00 for both Microscopic and PCR laboratory detection methods. 展开更多
关键词 Sensitivity SPECIFICITY Type I and II errors Detection Methods Hypothesis testing
暂未订购
上一页 1 2 204 下一页 到第
使用帮助 返回顶部