期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Improvement on Frequency Performance of SOI SiGe HBT 被引量:1
1
作者 DAI Guang-hao WANG Sheng-rong LI Wen-jie 《Semiconductor Photonics and Technology》 CAS 2006年第3期150-152,193,共4页
Based on the advantages of SOI technology, the frequency performance of SiGe HBT with SOI structure has been simulated. Compared with bulk SiGe HBT, the results show that the buried oxide layer (BOX) can reduce coll... Based on the advantages of SOI technology, the frequency performance of SiGe HBT with SOI structure has been simulated. Compared with bulk SiGe HBT, the results show that the buried oxide layer (BOX) can reduce collector-base capacitance CCB with the maximum value 89.3%, substrate-base capacitance CSB with 94. 6%, and the maximum oscillation frequency is improved by 2.7. The SOl structure improves the frequency performance of SiGe HBT, which is adaptable to high-speed and high power applications. 展开更多
关键词 SOI SiGe HBT frequency performance Maximum oscillation frequency
在线阅读 下载PDF
Frequency Performance of Ring Oscillators Based on a-IGZO Thin-Film Transistors
2
作者 于广 武辰飞 +4 位作者 陆海 任芳芳 张荣 郑有炓 黄晓明 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第4期97-100,共4页
Ring oscillators based on indium gallium zinc oxide thin film transistors are fabricated on glass substrates. The oscillator circuit consists of seven delay stages and an output buffer inverter. The element inverter e... Ring oscillators based on indium gallium zinc oxide thin film transistors are fabricated on glass substrates. The oscillator circuit consists of seven delay stages and an output buffer inverter. The element inverter exhibits a voltage gain higher than -6 V/V and a wide output swing close to 85% of the full swing range. The dynamic performance of the ring oscillators is evaluated as a function of supply voltage and at different gate lengths. A maximum oscillation frequency of 0.88MHz is obtained for a supply voltage of 50V, corresponding to a propagation delay of less than 85 ns/stage. 展开更多
关键词 frequency performance of Ring Oscillators Based on a-IGZO Thin-Film Transistors
原文传递
A Novel Technology for Preparation of High Performance Fiber by Radio Frequency Heating CVD 被引量:1
3
《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第6期637-638,共2页
关键词 A Novel Technology for Preparation of High performance Fiber by Radio frequency Heating CVD RADIO
在线阅读 下载PDF
Evaluation of the performance of linearly frequency modulated signals generated by heterodyning two free-running laser diodes
4
作者 CHANG Meng-xu JIANG Li-zhong +2 位作者 LIU Qing-bo XU Jing CHEN Yang 《Optoelectronics Letters》 EI 2021年第5期266-270,共5页
A method to evaluate the influence of the laser linewidth on the linearly frequency-modulated(LFM)signals generated by heterodyning two free-running laser diodes(LDs)is proposed.The Pearson correlation coefficient bet... A method to evaluate the influence of the laser linewidth on the linearly frequency-modulated(LFM)signals generated by heterodyning two free-running laser diodes(LDs)is proposed.The Pearson correlation coefficient between the instantaneous frequency of the generated LFM signal and that of an ideal LFM signal is introduced to quantify the quality of the generated LFM signal.The closed-form solution of the correlation coefficient is given,which shows that the correlation coefficient is determined by the ratio of the LFM signal bandwidth to the square root of the total linewidth of the two LDs when the observation interval is fixed.Simulation results are also given,which proves the correctness of the theoretical results. 展开更多
关键词 LFM Pearson Evaluation of the performance of linearly frequency modulated signals generated by heterodyning two free-running laser diodes
原文传递
An approach to improving maneuver performance of coning algorithm
5
作者 汤传业 陈熙源 宋锐 《Journal of Southeast University(English Edition)》 EI CAS 2014年第4期439-444,共6页
Aiming to improve the maneuver performance of the strapdown inertial navigation attitude coning algorithm a new coning correction structure is constructed by adding a sample to the traditional compressed coning correc... Aiming to improve the maneuver performance of the strapdown inertial navigation attitude coning algorithm a new coning correction structure is constructed by adding a sample to the traditional compressed coning correction structure. According to the given definition of classical coning motion the residual coning correction error based on the new coning correction structure is derived. On the basis of the new structure the frequency Taylor series method is used for designing a coning correction structure coefficient and then a new coning algorithm is obtained.Two types of error models are defined for the coning algorithm performance evaluation under coning environments and maneuver environments respectively.Simulation results indicate that the maneuver accuracy of the new 4-sample coning algorithm is almost double that of the traditional compressed 4-sample coning algorithm. The new coning algorithm has an improved maneuver performance while maintaining coning performance compared to the traditional compressed coning algorithm. 展开更多
关键词 coning algorithm coning correction structure maneuver performance coning performance frequency Taylor series method coning algorithm coning correction structure maneuver performance coning performance frequency Taylor series method
在线阅读 下载PDF
Influence of Velocity Overshoot Effect on High Frequency Perform- ance of AlGaAs / GaAs HBT's
6
作者 Xu Jun, Liu Youbao and Huang Chang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1992年第4期14-15,18-2+6,共5页
The semiclassical transport equations are used to study the high frequency performance of AlGaAs / GaAs HBTs. Electron velocity overshoot effect and its influence on the cut off frequency characteristics of AlGaAs / G... The semiclassical transport equations are used to study the high frequency performance of AlGaAs / GaAs HBTs. Electron velocity overshoot effect and its influence on the cut off frequency characteristics of AlGaAs / GaAs HBTs with different collector design parameters are analyzed and discussed. 展开更多
关键词 HBT Influence of Velocity Overshoot Effect on High frequency Perform high ance of AlGaAs
在线阅读 下载PDF
汽车仪表校验中高精度定时技术的应用 被引量:1
7
作者 陈旭红 杨勇波 《交通节能与环保》 2007年第2期31-33,共3页
文章给出了便携式汽车仪表校验仪的整体结构,在此基础上分析了视觉闪变在仪表校验中的不可避免性,并提出了利用高精度定时技术解决视觉闪变的方案。在分析Windows XP操作系统定时技术的基础上,给出了方案的具体实现。
关键词 视觉闪变 高精度定时 Query performance frequency Query performance Counter
在线阅读 下载PDF
Virtual Synchronous Generator Adaptive Control of Energy Storage Power Station Based on Physical Constraints
8
作者 Yunfan Huang Qingquan Lv +1 位作者 Zhenzhen Zhang Haiying Dong 《Energy Engineering》 EI 2023年第6期1401-1420,共20页
The virtual synchronous generator(VSG)can simulate synchronous machine’s operation mechanism in the control link of an energy storage converter,so that an electrochemical energy storage power station has the ability ... The virtual synchronous generator(VSG)can simulate synchronous machine’s operation mechanism in the control link of an energy storage converter,so that an electrochemical energy storage power station has the ability to actively support the power grid,from passive regulation to active support.Since energy storage is an important physical basis for realizing the inertia and damping characteristics in VSG control,energy storage constraints of the physical characteristics on the system control parameters are analyzed to provide a basis for the system parameter tuning.In a classic VSG control,its virtual inertia and damping coefficient remain unchanged.When the grid load changes greatly,the constant control strategy most likely result in the grid frequency deviation beyond the stable operation standard limitations.To solve this problem,a comprehensive control strategy considering electrified wire netting demand and energy storage unit state of charge(SOC)is proposed,and an adaptive optimization method of VSG parameters under different SOC is given.The energy storage battery can maintain a safe working state at any time and be smoothly disconnected,which can effectively improve the output frequency performance of energy storage system.Simulation results further demonstrated the effectiveness of the VSG control theoretical analysis. 展开更多
关键词 VSG energy storage power station physical constraints of energy storage adaptive parameter frequency performance
在线阅读 下载PDF
Tunable circularly-polarized turnstile-junction mode converter for high-power microwave applications
9
作者 Xiao-Yu Wang Yu-Wei Fan +2 位作者 Ting Shu Cheng-Wei Yuan Qiang Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期502-506,共5页
Frequency tunability has become a subject of concern in the field of high-power microwave(HPM) source research.However, little information about the corresponding mode converter is available. A tunable circularly-po... Frequency tunability has become a subject of concern in the field of high-power microwave(HPM) source research.However, little information about the corresponding mode converter is available. A tunable circularly-polarized turnstilejunction mode converter(TCTMC) for high-power microwave applications is presented in this paper. The input coaxial TEM mode is transformed into TE(10) mode with different phase delays in four rectangular waveguides and then converted into a circularly-polarized TE(11) circular waveguide mode. Besides, the rods are added to reduce or even eliminate the reflection. The innovations in this study are as follows. The tunning mechanism is added to the mode converter, which can change the effective length of rectangular waveguide and the distance between the rods installed upstream and the closest edge of the rectangular waveguide, thus improving the conversion efficiency and bandwidth. The conversion efficiency of TCTMC can reach above 98% over the frequency range of 1.42 GHz–2.29 GHz, and the frequency tunning bandwidth is about 47%. Significantly, TCTMC can obtain continuous high conversion efficiency of different frequency points with the change of tuning mechanism. 展开更多
关键词 mode converter high conversion efficiency frequency tuning performance
原文传递
ADRC BASED INPUT DISTURBANCE REJECTION FOR MINIMUM-PHASE PLANTS WITH UNKNOWN ORDERS AND/OR UNCERTAIN RELATIVE DEGREES 被引量:16
10
作者 Chunzhe ZHAO Yi HUANG 《Journal of Systems Science & Complexity》 SCIE EI CSCD 2012年第4期625-640,共16页
The capability of ADRC is studied for linear time-invariant SISO minimum-phase systems with unknown orders, uncertain relative degrees, and unknown input disturbances. It is proved that ADRC can reject the unknown inp... The capability of ADRC is studied for linear time-invariant SISO minimum-phase systems with unknown orders, uncertain relative degrees, and unknown input disturbances. It is proved that ADRC can reject the unknown input disturbance and guarantee the close-loop stability for the plants with unknown but bounded relative degrees. Meanwhile, some close-loop performances can be achieved. The influence of the sensor noise is also discussed. And it is demonstrated by numerical examples that one ADRC with fixed parameters can be applied to a group of plants of different orders, relative degrees, and parameters. 展开更多
关键词 ADRC frequency performance sensor noise uncertain relative degree unknown input disturbance unknown order.
原文传递
Calculating the transient behavior of grounding systems using inverse Laplace transform 被引量:3
11
作者 Nabiollah RAMEZANI Seyed Mohammad SHAHRTASH 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2011年第3期250-262,共13页
This paper deals with a unified and novel approach for analyzing the frequency and time domain performance of grounding systems.The proposed procedure is based on solving the full set of Maxwell's equations in the... This paper deals with a unified and novel approach for analyzing the frequency and time domain performance of grounding systems.The proposed procedure is based on solving the full set of Maxwell's equations in the frequency domain,and enables the exact computation of very near fields at the surface of the grounding grid,as well as far fields,by simple and accurate closed-form expressions for solving Sommerfeld integrals.In addition,the soil ionization is easily considered in the proposed method.The frequency domain responses are converted to the time domain by fast inverse Laplace transform.The results are validated and have shown acceptable accuracy. 展开更多
关键词 Electromagnetic field Near-field computation High frequency performance Soil ionization Grounding system Fast inverse Laplace transform
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部